Abstract:
:The advent of hybridoma technology has provided the immunotechnologist a finely tunable instrument that should permit a marked advance in the immunologic sciences. The ability to choose the precise antibody required and the virtually unlimited availability of easily purified antibodies have already resulted in the simultaneous immunometric assay and potential reagents for immunoscintigraphy and immunotherapy. Using an antibody with a specific affinity and recognition for a specific antigenc determinant can greatly influence the shape and range of a radioimmunometric calibration curve. With monoclonal antibodies, assay systems based on immune complexes (e.g., turbidimetric assays and counterimmunoelectrophoresis) can be made more precise, thus permitting study of the basic physicochemical principles underlying the antigen-antibody reaction and the development of greatly improved quantitative assays. On the other hand, the ability to select an antibody exhibiting specific characteristics implies the necessity to select. One no longer has the luxury of using a mixture of antibodies, hoping to take advantage of the fact that some will have desirable secondary characteristics such as electrophoretic mobility or the ability to absorb to plastics.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
David GS,Wang R,Bartholomew R,Sevier ED,Adams TH,Greene HEsubject
Has Abstractpub_date
1981-09-01 00:00:00pages
1580-5issue
9eissn
0009-9147issn
1530-8561journal_volume
27pub_type
杂志文章abstract::We compared three radioligands for use in a cytoplasmic estrogen-receptor assay, using pooled cytosol from human breast adenocarcinomas. The estrogen receptor content was determined in vitro by a dextran-coated charcoal method involving a 4-h incubation with and without diethylstilbestrol. Tritiated moxestrol failed t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-03-01 00:00:00
abstract:BACKGROUND:Nandrolone is one of the most abused anabolic steroids, and its use in doping is increasing, as revealed by numerous positive cases during recent years in various sports. Different authors have reported the possible natural production of nandrolone metabolites in humans, and some of these authors argued that...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2003.022848
更新日期:2004-02-01 00:00:00
abstract::We describe a simple method for evaluating thyroxine-binding globulin capacity and concentration from a single 1-cm blood spot on filter-paper used in a screening program for neonatal hypothyroidism. This method permits prompt diagnosis of about 90% of the infants with thyroxine-binding globulin deficiency in our abno...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-03-01 00:00:00
abstract::We conducted a proficiency survey of cholesterol and high-density lipoprotein (HDL) cholesterol analysis in local clinical laboratories to determine whether increased national emphasis on cholesterol measurement had resulted in changes in performance from previous surveys. Sets of frozen aliquots of plasma and HDL sup...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-08-01 00:00:00
abstract:BACKGROUND:The European Atherosclerosis Society-European Federation of Clinical Chemistry and Laboratory Medicine Consensus Panel aims to provide recommendations to optimize atherogenic lipoprotein quantification for cardiovascular risk management. CONTENT:We critically examined LDL cholesterol, non-HDL cholesterol, a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.287037
更新日期:2018-07-01 00:00:00
abstract::It has been hypothesized over many years that the autoimmune endocrine diseases are each due to antigen-specific defects in suppressor (regulatory) T lymphocyte function. There is now increasing evidence in studies of autoimmune thyroid disease and insulin-dependent diabetes mellitus that suppressor cells are activate...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1994-11-01 00:00:00
abstract:BACKGROUND:Near-infrared spectroscopy is proposed as a method for providing real-time urea concentrations during hemodialysis treatments. The feasibility of such noninvasive urea measurements is evaluated in undiluted dialysate fluid. METHODS:Near-infrared spectra were collected from calibration solutions of urea prep...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2001-01-01 00:00:00
abstract:BACKGROUND:Understanding the distribution of C-reactive protein (CRP) concentration among adult women in the US helps to establish the magnitude of women at increased risk for cardiovascular disease. METHODS:We examined the distribution and correlates of CRP, using data from 2205 women >or=20 years of age from the Nat...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.027359
更新日期:2004-03-01 00:00:00
abstract::The clinical utilities of the emerging biochemical markers for mammary adenocarcinoma CA 15-3, CA 549, CA M26, CA M29, and MCA (mucin-like carcinoma-associated antigen) were assessed by a formal rating according to six desirable marker characteristics. All five indicators similarly have good specificities but limited ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1993-11-01 00:00:00
abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-10-01 00:00:00
abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-03-01 00:00:00
abstract:BACKGROUND:Variability among assays used to measure intact parathyroid hormone (iPTH) is of particular concern because of the routine use of iPTH assay results to guide management of osteodystrophy and calcium metabolism in patients with end-stage renal disease (ESRD). The aim of this study was to determine the extent ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.071589
更新日期:2006-09-01 00:00:00
abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1093/clinchem/hvaa287
更新日期:2021-01-08 00:00:00
abstract::Urinary polyamines were measured by a fluorometric thin-layer chromatographic technique in samples collected daily throughout a single menstrual cycle by each of 13 healthy women. Polyamine excretion fluctuated considerably, but excretion of putrescine, spermidine, and spermine combined was consistently greatest durin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-05-01 00:00:00
abstract::Biological variation is inherent in all medical tests and is a major source of error in clinical test interpretation. We use inherent test error due to biological variability as the touchstone by which to validate the clinical acceptability of analytical goals. Analytical goals should consist of sets of complementary ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1993-07-01 00:00:00
abstract:BACKGROUND:Cardiac troponin T (cTnT) is the preferred biomarker for the diagnosis of acute myocardial infarction (AMI). It has been suggested that cTnT is present predominantly in fragmented forms in human serum following AMI. In this study, we have used a targeted mass spectrometry assay and epitope mapping using West...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.261511
更新日期:2017-02-01 00:00:00
abstract:BACKGROUND:Advances in the biological sciences and technology are providing molecular targets for diagnosing and treating cancer. Current classifications in surgical pathology for staging malignancies are based primarily on anatomic features (e.g., tumor-node-metastasis) and histopathology (e.g., grade). Microarrays to...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:2002-08-01 00:00:00
abstract:BACKGROUND:About 5% of patients with neurofibromatosis type 1 (NF1) bear constitutional microdeletions that encompass NF1 (neurofibromin 1) and neighboring genes. These patients are characterized by the development of a high number of dermal neurofibromas (dNFs), mental retardation, and an increased risk of developing ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2012.194217
更新日期:2013-06-01 00:00:00
abstract::Several aspects of mass spectrometry and gas chromatography-mass spectrometry are reviewed, including ionization methods, repetitive scanning, selected ion monitoring, and stable isotope measurement. I discuss the application of these and other mass spectrometry methods to the investigation of compound classes relevan...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-06-01 00:00:00
abstract::We measured the concentration of erythrocyte protoporphyrin in 43 blood samples by two fluorometric methods. In the indirect method, protoporphyrin was extracted from blood and the fluorescence of the free acid in the extract was determined with a filter-fluorometer. These results were compared with results of direct ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-09-01 00:00:00
abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1981-07-01 00:00:00
abstract::We compare measurement of total fast hemoglobin (HbA1) by "high-performance" liquid chromatography and by electrophoresis on agar gel. Blood samples were obtained from a diverse population (n = 222): offspring of two diabetic parents, diabetic patients with and without retinopathy, diabetic and non-diabetic pregnant w...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-03-01 00:00:00
abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-01-01 00:00:00
abstract:BACKGROUND:The time required for bloodstream pathogen detection, identification (ID), and antimicrobial susceptibility testing (AST) does not satisfy the acute needs of disease management. Conventional methods take up to 3 days for ID and AST. Molecular diagnostics have reduced times for ID, but their promise to suppla...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.290189
更新日期:2018-10-01 00:00:00
abstract::Unsaturated cobalamin-binding capacity in plasma (P-UBBC) is determined by use of a silica gel (QUSO G32) to separate haptocorrin (P-ApoHC) and transcobalamin (P-ApoTC). The method is sensitive and precise: detection limit 13 pmol/L, interassay coefficients of variation 3% for P-UBBC (mean = 1080 pmol/L), 4% for P-Apo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-07-01 00:00:00
abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-12-01 00:00:00
abstract::We measured changes in concentrations of magnesium, zinc, calcium, potassium, cholesterol [total and high-density lipoproteins (HDL)], total creatine kinase (CK), and CK isoenzyme-MB in plasma (PI) and/or erythrocytes (Erc) from apparently healthy subjects and from patients with either pre-infarction syndrome (PIS) or...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-10-01 00:00:00
abstract:BACKGROUND:PCR-based mutation detection is prone to methodological errors, e.g., in restriction length fragment polymorphism (RFLP) and allele-specific amplification (ASA), false PCR results may occur because of technical faults or atypical new mutations. METHODS:We investigated the ability of a genotyping assay based...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-12-01 00:00:00
abstract::We compared a chemiluminescent assay and a colorimetric endpoint assay for measuring an alkaline phosphatase (EC 3.1.3.1) label in an enzyme immunoassay of thyrotropin (TSH). The substrate in the chemiluminescent assay is a derivative of adamantyl 1,2-dioxetane phosphate. On dephosphorylation, catalyzed by alkaline ph...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-07-01 00:00:00
abstract::We describe the conjoint measurement in urine of the alcoholic catecholamine metabolites 3,4-dihydroxyphenylglycol (DHPG) and 3-methoxy-4-hydroxyphenylglycol (MHPG). The method involves extraction with ethyl acetate and back-extraction into acetic acid (MHPG), followed by adsorption onto alumina (DHPG). The separation...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-05-01 00:00:00