Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

Abstract:

:Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Between-batch CVs, based on results of repeat analysis of routine patients' samples, were 4.6%, 7.0%, and 5.3%, respectively. Results correlated well with those by methods previously used [gas chromatography and fluorescence polarization (Abbott TDx)], but there was a negative bias (-10.9%) of our method for phenobarbital results in patients' samples, as compared with those obtained with the TDx.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Moore FM,Simpson D

subject

Has Abstract

pub_date

1989-08-01 00:00:00

pages

1782-4

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Do enzymatic analyses of serum triglycerides really need blanking for free glycerol?

    abstract::Distributions of concentrations of free glycerol in clinical plasma obtained for triglyceride assay were compiled to determine the frequency with which increased concentrations of free glycerol posed a potential problem for clinical interpretation of triglyceride results. Clinical histories were studied in patients wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jessen RH,Dass CJ,Eckfeldt JH

    更新日期:1990-07-01 00:00:00

  • Chemiluminescent assay of alkaline phosphatase applied in an ultrasensitive enzyme immunoassay of thyrotropin.

    abstract::We compared a chemiluminescent assay and a colorimetric endpoint assay for measuring an alkaline phosphatase (EC 3.1.3.1) label in an enzyme immunoassay of thyrotropin (TSH). The substrate in the chemiluminescent assay is a derivative of adamantyl 1,2-dioxetane phosphate. On dephosphorylation, catalyzed by alkaline ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bronstein I,Voyta JC,Thorpe GH,Kricka LJ,Armstrong G

    更新日期:1989-07-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A

    更新日期:1997-09-01 00:00:00

  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Enzyme immunoassay for intact human insulin in serum or plasma.

    abstract::We describe an enzyme-linked two-site immunoassay for quantitation of intact insulin in human serum and plasma. The method uses two murine monoclonal antibodies that bind to two different epitopes on the insulin molecule. The immunoassay is specific. Human proinsulin is not bound by the antibodies, and the binding of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andersen L,Dinesen B,Jørgensen PN,Poulsen F,Røder ME

    更新日期:1993-04-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • An interlaboratory study of measurement of aspartate aminotransferase activity with use of purified enzyme materials.

    abstract::The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Burtis CA,Sampson EJ,Bayse DD,McKneally SS,Whitner VS

    更新日期:1978-06-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Apolipoprotein B and A-I values in 147576 Swedish males and females, standardized according to the World Health Organization-International Federation of Clinical Chemistry First International Reference Materials.

    abstract::Serum concentrations of apolipoprotein (apo) B and apo A-I were measured from 1985-1996 in a Swedish population sample of 83 112 males and 64 464 females, ages <20 to >80 years, using an automated immunoturbidimetric method calibrated against fresh pools of human serum and commercial calibrators. All values were recal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jungner I,Marcovina SM,Walldius G,Holme I,Kolar W,Steiner E

    更新日期:1998-08-01 00:00:00

  • Analysis for diazepam and nordiazepam by electron-capture gas chromatography and by liquid chromatography.

    abstract::We describe the use of electron-capture gas chromatography or reversed-phase "high-performance" liquid chromatography for concurrent analysis for diazepam and nordiazepam in serum. In the gas-chromatographic analysis our use of a new chemically deactivated stationary liquid phase, SP 2250-DB (Supelco, Inc.), resulted ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wallace JE,Schwertner HA,Shimek EL Jr

    更新日期:1979-07-01 00:00:00

  • Laboratory methods and quality assurance in the Cardiovascular Health Study.

    abstract::The Cardiovascular Health Study is an observational cohort study of risk factors for cardiovascular disease in 5201 participants, ages > or = 65 years. We report the methods and quality-assurance results for blood procurement, processing, shipping, storage, and sample analysis used during the first examination period ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cushman M,Cornell ES,Howard PR,Bovill EG,Tracy RP

    更新日期:1995-02-01 00:00:00

  • Highly specific radioimmunoassay for human insulin based on immune exclusion of all insulin precursors.

    abstract::We describe a rapid and simple insulin RIA in which proinsulin and conversion intermediates do not interfere. Three monoclonal antibodies (S1, S2, and S53) were selected for their specificity (directed, respectively, against the B10 region, the junction between A chain and C-peptide, and the junction between B chain a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Deberg M,Houssa P,Frank BH,Sodoyez-Goffaux F,Sodoyez JC

    更新日期:1998-07-01 00:00:00

  • Thyroid hormone contamination in crystalline diiodotyrosine.

    abstract::Crystalline preparations of diiodotyrosine contain trace quantities of thyroxine that can be detected by several competitive radioassays and by chromatography on Sephadex. Spontaneous coupling of diiodotyrosine to thyroxine during iodination of tyrosine and coprecipitation of hormone with diiodotyrosine crystals are l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Alexander NM,Nishimoto M

    更新日期:1978-10-01 00:00:00

  • High-purity 4-nitrophenol: purification, characterization, and specifications for use as a spectrophotometric reference material.

    abstract::We describe specifications for high-purity 4-nitrophenol, which is suitable for spectrophotometric standardization. Such a reference material is needed in clinical enzymology to establish the proper molar absorptivity of 4-nitrophenol under final reaction conditions, particularly for measuring alkaline phosphatase act...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers GN Jr,McComb RB,Christensen RG,Schaffer R

    更新日期:1980-05-01 00:00:00

  • Liquid-chromatographic procedure for tricyclic drugs and their metabolites in plasma.

    abstract::We describe a procedure for determining amitriptyline and imipramine and their active metabolites nortriptyline and desipramine, respectively, at therapeutic concentrations in human plasma by use of liquid chromatography. The drugs are extracted at pH 10.5 into hexane/isoamyl alcohol, which is evaporated and the resid...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vandemark FL,Adams RF,Schmidt GJ

    更新日期:1978-01-01 00:00:00

  • Biological variability in concentrations of serum lipids: sources of variation among results from published studies and composite predicted values.

    abstract::To obtain the best estimates of the average intraindividual biological variability (CVb) in the concentrations of total cholesterol (TC), low-density lipoprotein cholesterol (LDLC), high-density lipoprotein cholesterol (HDLC), and triglyceride serum lipids in a person's blood, we evaluated results from 30 studies publ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:

    authors: Smith SJ,Cooper GR,Myers GL,Sampson EJ

    更新日期:1993-06-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Adenosine deaminase binding protein, a new diagnostic marker for kidney disease.

    abstract::This enzyme immunoassay detects adenosine deaminase binding protein (ABP), a glycoprotein that is shed from the brush border of the proximal tubule in kidney damage. Two monoclonal antibodies, URO-4 and URO-4a, each react with different epitopes on ABP and are used as the "sandwich" pair of antibodies. A linear standa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson RE,Piper DJ,Galberg C,Chan TH,Tolkoff-Rubin NE,Rubin RH

    更新日期:1985-05-01 00:00:00

  • Gene amplification for c-erbB-2, c-myc, epidermal growth factor receptor, int-2, and N-myc measured by quantitative PCR with a multiple competitor template.

    abstract::We recently proposed a quantitative PCR procedure for the absolute measurement of c-erbB-2 oncogene amplification, based on the simultaneous polymerase chain reaction (PCR) amplification of the target gene and of a competitor DNA molecule acting as internal standard. To increase the number of assayable oncogenes and t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sestini R,Orlando C,Zentilin L,Lami D,Gelmini S,Pinzani P,Giacca M,Pazzagli M

    更新日期:1995-06-01 00:00:00

  • Estimation of very-low-density lipoprotein cholesterol from data on triglyceride concentration in plasma.

    abstract::We examined the relationship in a large-living population between the concentration of triglycerides in plasma from fasting persons and the concentration of very-low-density lipoprotein cholesterol (VLDL-C) as determined after preparative ultracentrifugation. Data from individuals in the Framingham Heart Study who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson PW,Abbott RD,Garrison RJ,Castelli WP

    更新日期:1981-12-01 00:00:00

  • Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

    abstract:BACKGROUND:The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS:We tested 18 specimens after centrifuga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.6.935

    authors: Grenache DG,Parvin CA,Gronowski AM

    更新日期:2003-06-01 00:00:00

  • A new commercial method for the enzymatic determination of creatinine in serum and urine evaluated: comparison with a kinetic Jaffé method and isotope dilution-mass spectrometry.

    abstract::We evaluated a new, simple, enzymatic kinetic method from Wako Chemicals GmbH in comparison with a kinetic Jaffé method by using isotope dilution-mass spectrometry (ID-MS) as a reference method. An ID-MS-calibrated serum standard was used. Both the enzymatic and the Jaffé method correlated well with ID-MS, except for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindbäck B,Bergman A

    更新日期:1989-05-01 00:00:00

  • Evaluation of the lysosome-associated membrane protein LAMP-2 as a marker for lysosomal storage disorders.

    abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hua CT,Hopwood JJ,Carlsson SR,Harris RJ,Meikle PJ

    更新日期:1998-10-01 00:00:00

  • gamma-Glutamyltransferase as a predictor of chronic kidney disease in nonhypertensive and nondiabetic Korean men.

    abstract:BACKGROUND:Little research has been done to examine whether gamma-glutamyltransferase (GGT) is prospectively associated with the development of chronic kidney disease (CKD). We performed a prospective study to examine the association between GGT and the risk for the development of CKD. METHODS:The study cohort include...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.078980

    authors: Ryu S,Chang Y,Kim DI,Kim WS,Suh BS

    更新日期:2007-01-01 00:00:00

  • Noninvasive prenatal diagnosis of duchenne muscular dystrophy: comprehensive genetic diagnosis in carrier, proband, and fetus.

    abstract:BACKGROUND:Noninvasive prenatal diagnosis of monogenic disorders using maternal plasma and targeted massively parallel sequencing is being investigated actively. We previously demonstrated that comprehensive genetic diagnosis of a Duchenne muscular dystrophy (DMD) patient is feasible using a single targeted sequencing ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.236380

    authors: Yoo SK,Lim BC,Byeun J,Hwang H,Kim KJ,Hwang YS,Lee J,Park JS,Lee YS,Namkung J,Park J,Lee S,Shin JY,Seo JS,Kim JI,Chae JH

    更新日期:2015-06-01 00:00:00

  • Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

    abstract::We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Li PK,Shull BC

    更新日期:1979-04-01 00:00:00

  • Turnover rate of skeletal alkaline phosphatase in humans.

    abstract::Two patients with Paget's disease of bone were subjected to plasmapheresis. Alkaline phosphatase activities of serum declined sharply, but returned to preplasmapheresis values within eight to 10 days. The biological half-life of circulating skeletal alkaline phosphatase, as calculated from these experiments, is betwee...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Posen S,Grunstein HS

    更新日期:1982-01-01 00:00:00

  • The inseparable triad: analytical sensitivity, measurement uncertainty, and quantitative resolution.

    abstract::The formal definition of sensitivity associates the term with the change in the response of a system for a small change of the stimulus causing the response, i.e., the ratio of the response of a system to the stimulus causing it. One interpretation of sensitivity associates the rate of change of the response for a sma...

    journal_title:Clinical chemistry

    pub_type: 评论,杂志文章

    doi:

    authors: Pardue HL

    更新日期:1997-10-01 00:00:00

  • Automated enzymic measurement of total cholesterol in serum.

    abstract::We describe a completely automated enzymic system for measuring total cholesterol in serum. All reagents are contained in an analytical test pack and the test is performed on Du Pont's Automatic Clinical Analyzer (aca), which mixes the sample (20 microliter) and reagents and performs the necessary absorbance measureme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rautela GS,Liedtke RJ

    更新日期:1978-01-01 00:00:00