The inseparable triad: analytical sensitivity, measurement uncertainty, and quantitative resolution.

Abstract:

:The formal definition of sensitivity associates the term with the change in the response of a system for a small change of the stimulus causing the response, i.e., the ratio of the response of a system to the stimulus causing it. One interpretation of sensitivity associates the rate of change of the response for a small change of the stimulus as the slope of a calibration plot of response vs stimulus. An alternative interpretation associates sensitivity with the smallest value of the stimulus that can be resolved with a given degree of confidence, i.e., the detection limit. Applications of the first usage to analytical chemistry date at least to the beginning of this century; applications of the second interpretation are of more recent origin. The accompanying paper argues in favor of the second interpretation on the basis that, among other things, the "slope" interpretation conflicts with the formal definition of sensitivity and is meaningless as a descriptor of the performance of a measuring system. In this paper I offer arguments to support my belief that the slope definition of sensitivity is consistent with both formal definitions and accepted usage in analytical chemistry and, more importantly, that it is an invaluable descriptor of one of the most important characteristics of any analytical method. I include information to support my belief that proper use of the slope definition yields much more information than is available in the "detection limit" interpretation.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Pardue HL

subject

Has Abstract

pub_date

1997-10-01 00:00:00

pages

1831-7

issue

10

eissn

0009-9147

issn

1530-8561

journal_volume

43

pub_type

评论,杂志文章
  • Micromethod for lead determination in whole blood by atomic absorption, with use of the graphite furnace.

    abstract::I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fernandez FJ

    更新日期:1975-04-01 00:00:00

  • Reported effects of long-term freezer storage on concentrations of retinol, beta-carotene, and alpha-tocopherol in serum or plasma summarized.

    abstract::A literature review of the effects of long-term freezer storage on concentrations of antioxidant micronutrients in serum or plasma showed that a high proportion of the studies that compared the concentrations of retinol, beta-carotene, or alpha-tocopherol in fresh and stored serum were deficient because of small numbe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Comstock GW,Alberg AJ,Helzlsouer KJ

    更新日期:1993-06-01 00:00:00

  • Two-site enzyme immunoassay of CD4 and CD8 molecules on the surface of T lymphocytes from healthy subjects and HIV-1-infected patients.

    abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Carriere D,Fontaine C,Berthier AM,Rouquette AM,Carayon P,Laprode M,Juillard R,Jansen A,Paoli P,Paolucci F

    更新日期:1994-01-01 00:00:00

  • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC.

    abstract::Assays with different specificity are used for cyclosporin monitoring in clinical transplantation. A recent survey of 35 centers showed that 86% used immunoassays for cyclosporin A (CsA). In consensus documents the following performance criteria were recommended: (a) imprecision < or = 10% at 50 microg/L and < or = 5%...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schütz E,Svinarov D,Shipkova M,Niedmann PD,Armstrong VW,Wieland E,Oellerich M

    更新日期:1998-10-01 00:00:00

  • Two-dimensional gel electrophoresis of human brain proteins. II. Specific proteins and brain subfractions.

    abstract::Brain proteins extractable with distilled water or 9 mol/L urea were subjected to two-dimensional gel electrophoresis. They are examined in relation to the identification of actin, tubulin, neurofilament proteins, glial fibrillary acidic protein; proteins of human embryonic neocortex, synaptosomes, myelin, and plasma;...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Comings DE,Carraway NG,Pekkula-Flagan A

    更新日期:1982-04-01 00:00:00

  • Use of proximity ligation to screen for inhibitors of interactions between vascular endothelial growth factor A and its receptors.

    abstract:BACKGROUND:Improved methods are required to screen drug candidates for their influences on protein interactions. There is also a compelling need for miniaturization of screening assays, with attendant reductions in reagent consumption and assay costs. METHODS:We used sensitive, miniaturized proximity ligation assays (...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.099424

    authors: Gustafsdottir SM,Wennström S,Fredriksson S,Schallmeiner E,Hamilton AD,Sebti SM,Landegren U

    更新日期:2008-07-01 00:00:00

  • Coupled-column liquid chromatographic analysis of catecholamines, serotonin, and metabolites in human urine.

    abstract::A column-switching HPLC system was utilized for the simultaneous determination of epinephrine, norepinephrine, dopamine, serotonin, and their metabolites metanephrine, normetanephrine, 3, 4-dihydroxyphenylacetic acid, homovanillic acid, and 5-hydroxyindoleacetic acid in human urine. The sample was injected directly on...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Panholzer TJ,Beyer J,Lichtwald K

    更新日期:1999-02-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ

    更新日期:1994-06-01 00:00:00

  • Extended clinical trial and evaluation of glucose determination with the Eastman Kodak Ektachem GLU/BUN Analyzer.

    abstract::We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by this technique, by the FDA Proposed Class Standard glucose reference met...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Bandi ZL,Fuller JB,Bee DE,James GP

    更新日期:1981-01-01 00:00:00

  • Totally automated liquid-chromatographic assay for cortisol and associated glucocorticoids in serum, with use of ASTED sample preparation.

    abstract::We describe estimation of total cortisol in serum by HPLC. Incorporation of a new technique to totally automate sample preparation decreases costs. The benefits of HPLC ensure that interferences from other steroids are avoided. The method can also be used to estimate concentrations of other glucocorticoids in serum. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Turnell DC,Cooper JD,Green B,Hughes G,Wright DJ

    更新日期:1988-09-01 00:00:00

  • Detection of microdeletion 22q11.2 in a fetus by next-generation sequencing of maternal plasma.

    abstract:BACKGROUND:Efforts have been undertaken recently to assess the fetal genome through analysis of circulating cell-free (ccf) fetal DNA obtained from maternal plasma. Sequencing analysis of such ccf DNA has been shown to enable accurate prenatal detection of fetal aneuploidies, including trisomies of chromosomes 21, 18, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.180794

    authors: Jensen TJ,Dzakula Z,Deciu C,van den Boom D,Ehrich M

    更新日期:2012-07-01 00:00:00

  • LC-MS/MS Measurement of Parathyroid Hormone-Related Peptide.

    abstract:INTRODUCTION:Parathyroid hormone-related peptide (PTHrP) is involved in activating pathways, allowing tumor cells to form bone metastases. Measurement of PTHrP is used for the diagnosis and clinical management of patients suspected of hypercalcemia of malignancy. We developed an LC-MS/MS method for measuring PTHrP, est...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244012

    authors: Kushnir MM,Rockwood AL,Strathmann FG,Frank EL,Straseski JA,Meikle AW

    更新日期:2016-01-01 00:00:00

  • Effects of serum-isolated vs synthetic bilirubin-albumin complexes on dye-binding methods for estimating serum albumin.

    abstract::Bush and Reed reported (Clin Chem 1987;33:821-3) that the reaction of albumin with bromcresol purple but not with bromcresol green underestimated the concentration of albumin in synthetically obtained bilirubin-albumin (Bd) by 29%. Their unproven assumption was that chemically synthesized Bd behaved in a manner indist...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ihara H,Nakamura H,Aoki Y,Aoki T,Yoshida M

    更新日期:1991-07-01 00:00:00

  • Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

    abstract::We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Li PK,Shull BC

    更新日期:1979-04-01 00:00:00

  • Chromosomal instability in cell-free DNA is a serum biomarker for prostate cancer.

    abstract:BACKGROUND:Genomic instability resulting in copy number variation is a hallmark of malignant transformation and may be identified through massive parallel sequencing. Tumor-specific cell free DNA (cfDNA) present in serum and plasma provides a real-time, easily accessible surrogate. METHODS:DNA was extracted from serum...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.226571

    authors: Schütz E,Akbari MR,Beck J,Urnovitz H,Zhang WW,Bornemann-Kolatzki K,Mitchell WM,Nam RK,Narod SA

    更新日期:2015-01-01 00:00:00

  • Incubation with neuraminidase and affinity electrophoresis with wheat-germ lectin compared for separating and quantifying alkaline phosphatase isoenzymes in plasma.

    abstract::Of 98 patients' specimens examined for alkaline phosphatase (EC 3.1.3.1) isoenzymes by electrophoresis on cellulose acetate membrane after incubation with neuraminidase, 50 showed only a single liver or bone isoenzyme staining band; in 15 of these, the tissue origin of the fraction could not be accurately identified f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY

    更新日期:1985-07-01 00:00:00

  • Immunological assays of apolipoproteins in plasma: methods and instrumentation.

    abstract::A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Labeur C,Shepherd J,Rosseneu M

    更新日期:1990-04-01 00:00:00

  • Hemoglobin Görwihl [alpha2beta(2)5(A2)Pro-->Ala], an electrophoretically silent variant with impaired glycation.

    abstract:BACKGROUND:Some of the genetic variants of hemoglobin (Hb) and their chemically modified species are known to affect the measurement of Hb A(1c). The purpose of this study was to characterize Hb species in the blood sample of a 74-year-old German male with an exceptionally low Hb A(1c) value. METHODS:Hemolysates from ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.1.137

    authors: Bissé E,Schauber C,Zorn N,Epting T,Eigel A,Van Dorsselaer A,Wieland H,Kister J,Kiger L

    更新日期:2003-01-01 00:00:00

  • Immunochemical approach to the question of inactive subunits in cases of lactate dehydrogenase B subunit deficiency.

    abstract::If there were enzymatically inactive B subunits in a solution containing lactate dehydrogenase (LD) B4 prepared from the hemolysates of heterozygous individuals with LD-B subunit deficiency, the inactive subunits would compete with normal subunits for antibodies to the B4 subunit. Using the activity of normal LD-B4 as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maekawa M,Sudo K,Kanno T

    更新日期:1986-01-01 00:00:00

  • Measuring alveolar lavage fluid surfactant by fluorescence polarization.

    abstract::We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McCarroll NA,Van Lente F

    更新日期:1993-07-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains.

    abstract:BACKGROUND:The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Katzmann JA,Clark RJ,Abraham RS,Bryant S,Lymp JF,Bradwell AR,Kyle RA

    更新日期:2002-09-01 00:00:00

  • Analytical performance evaluation of EMIT II monoclonal amphetamine/methamphetamine assay: more specificity than EMIT d.a.u. monoclonal amphetamine/methamphetamine assay.

    abstract::We evaluated a new EMIT II monoclonal amphetamine/methamphetamine assay for screening human urine by comparing it with the EMIT d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg/L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Kinnaman G,Smith M,Johansen K

    更新日期:1993-01-01 00:00:00

  • Denaturing gradient-gel electrophoresis screening of familial defective apolipoprotein B-100 in a mixed Asian cohort: two cases of arginine3500-->tryptophan mutation associated with a unique haplotype.

    abstract::The Arg-to-Trp substitution at codon 3500 in the apolipoprotein (apo) B-100 gene is established as a cause of familial defective apo B-100 (FDB), a functional mutation, resulting in reduced LDL receptor binding and manifest hypercholesterolemia. In a search for similar mutations in 163 Malaysians, we screened the puta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Choong ML,Koay ES,Khoo KL,Khaw MC,Sethi SK

    更新日期:1997-06-01 00:00:00

  • Serum erythropoietin concentrations and iron status in patients on chronic hemodialysis.

    abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Seguchi C,Shima T,Misaki M,Takarada Y,Okazaki T

    更新日期:1992-02-01 00:00:00

  • Prognostic Utility of Galectin-3 for Recurrent Cardiovascular Events During Long-term Follow-up in Patients with Stable Coronary Heart Disease: Results of the KAROLA Study.

    abstract:BACKGROUND:Galectin-3 has emerged as a potential useful novel biomarker for heart failure and cardiovascular disease (CVD). However, it remains unclear whether galectin-3 is associated with recurrent cardiovascular events during long-term follow-up of patients with stable coronary heart disease (CHD) after adjustment f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.257550

    authors: Jansen H,Koenig W,Jaensch A,Mons U,Breitling LP,Scharnagl H,Stojakovic T,Schunkert H,Brenner H,Rothenbacher D

    更新日期:2016-10-01 00:00:00

  • Is succinyldicholine the substrate of choice for the measurement of cholinesterase activity?

    abstract::We have developed a succinyldicholine-based assay for serum cholinesterase (EC 3.1.1.8) to help establish whether patients with suspected sensitivity to drugs of this type have enzyme abnormalities that cannot be detected by conventional laboratory techniques. Although the method discriminates between cholinesterase a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Faye S,Evans RT

    更新日期:1986-08-01 00:00:00

  • Use of neural networks to diagnose acute myocardial infarction. II. A clinical application.

    abstract::We investigated the ability of neural networks to diagnose acute myocardial infarction (AMI) from laboratory data only. Several networks were trained with different combinations of data obtained at admission and within the first 12 h and 24 h after admission. The data used included the electrocardiogram (ECG) and the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pedersen SM,Jørgensen JS,Pedersen JB

    更新日期:1996-04-01 00:00:00

  • Pediatric and perinatal reference intervals for immunoglobulin light chains kappa and lambda.

    abstract::In routine analysis for immunoglobulin light chains in pediatric diagnostics, the age-related reference intervals for serum kappa (kappa) and lambda (lambda) light chains were evaluated in 1543 healthy subjects (newborns to age 16 years, including 168 premature infants). Light-chain analysis was performed by rate neph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herkner KR,Salzer H,Böck A,Mühl A,Tsaka T,Steger H,Pollak A,Schatten C,Popp W,Huber-Spitzy V

    更新日期:1992-04-01 00:00:00

  • Screening radioimmunoassay for aldosterone in preheated plasma without extraction and chromatography.

    abstract::We directly estimated plasma aldosterone radioimmunologically with use of an antiserum raised against an aldosterone-3-oxime/bovine serum albumin conjugate, the estimation being on samples with and without heating (60 degrees C), and diluted and undiluted. Values so obtained were compared with those by radioimmunoassa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Connolly TM,Tibor L,Gless KH,Vecsei P

    更新日期:1980-01-01 00:00:00