Chemiluminescent assay of alkaline phosphatase applied in an ultrasensitive enzyme immunoassay of thyrotropin.

Abstract:

:We compared a chemiluminescent assay and a colorimetric endpoint assay for measuring an alkaline phosphatase (EC 3.1.3.1) label in an enzyme immunoassay of thyrotropin (TSH). The substrate in the chemiluminescent assay is a derivative of adamantyl 1,2-dioxetane phosphate. On dephosphorylation, catalyzed by alkaline phosphatase, the 1,2-dioxetane decomposes further and emits a glow of light (lambda max 470 nm). We modified the Hybritech Tandem-E TSH High Sensitivity assay for chemiluminescent detection of bound alkaline phosphatase label by using this substrate (with 20-, 40-, and 60-min incubations). Detection limits (mean +2 SD of zero standard) were 6.0, 5.2, and 4.5 micro-int. units/L for these incubation periods, respectively, vs 20 micro-int. units/L for the conventional colorimetric version of the assay. Comparison of results for 44 clinical specimens assayed by the chemiluminescent (20-min incubation, y) and colorimetric (60-min endpoint, x) TSH immunoassays gave statistical values of: slope = 1.17, intercept = -0.22, and r = 0.98. Hemoglobin, but not bilirubin, lipids, or protein, interfered; but these interferents were removed by the washing steps in the enzyme immunoassay.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bronstein I,Voyta JC,Thorpe GH,Kricka LJ,Armstrong G

subject

Has Abstract

pub_date

1989-07-01 00:00:00

pages

1441-6

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Methylmalonic acid concentrations in serum of normal subjects: biological variability and effect of oral L-isoleucine loads before and after intramuscular administration of cobalamin.

    abstract::The clinical value of measuring concentrations of methylmalonic acid in serum (S-MMA) as an aid in the diagnosis of cobalamin deficiency has recently aroused interest. In 58 healthy subjects, ages 40-68 years, we found a 0.95 reference interval of 0.05-0.37 mumol/L (mean 0.21, SD 0.094). In 33 of the subjects, who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rasmussen K,Møller J,Ostergaard K,Kristensen MO,Jensen J

    更新日期:1990-07-01 00:00:00

  • Biological variation of blood acid-base status: consequences for analytical goal-setting and interpretation of results.

    abstract::Analytical, intra-individual, and interindividual components of variation have been determined for pH, pCO2, bicarbonate, base excess, and total CO2 in capillary specimens of whole blood from a cohort of 14 healthy subjects. Calculated analytical goals (SD) are pH less than or equal to 0.008, pCO2 less than or equal t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harding PJ,Fraser CG

    更新日期:1987-08-01 00:00:00

  • Molar absorptivity and the blank correction factor.

    abstract::In photometry, where both the product formed and one or several reactants absorb light at the same wavelength, the absorbance of the "blank" of the sample at the end of the reaction may be less than that measured at the beginning of the reaction, because of consumption of reactant(s). The blank correction factor for t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kroll MH,Elin RJ

    更新日期:1985-03-01 00:00:00

  • Presence of donor-derived DNA and cells in the urine of sex-mismatched hematopoietic stem cell transplant recipients: implication for the transrenal hypothesis.

    abstract:BACKGROUND:The term "transrenal DNA" was coined in 2000 to signify that DNA in urine may come from the passage of plasma DNA through the kidney barrier. Although DNA in the urine has the potential to provide a completely noninvasive source of nucleic acids for molecular diagnosis, its existence remains controversial. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.113530

    authors: Hung EC,Shing TK,Chim SS,Yeung PC,Chan RW,Chik KW,Lee V,Tsui NB,Li CK,Wong CS,Chiu RW,Lo YM

    更新日期:2009-04-01 00:00:00

  • Candidate gene genotypes, along with conventional risk factor assessment, improve estimation of coronary heart disease risk in healthy UK men.

    abstract:BACKGROUND:One of the aims of cardiovascular genetics is to test the efficacy of the use of genetic information to predict cardiovascular risk. We therefore investigated whether inclusion of a set of common variants in candidate genes along with conventional risk factor (CRF) assessment enhanced coronary heart disease ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.074591

    authors: Humphries SE,Cooper JA,Talmud PJ,Miller GJ

    更新日期:2007-01-01 00:00:00

  • Serum-constituents analyses: effect of duration and temperature of storage of clotted blood.

    abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ono T,Kitaguchi K,Takehara M,Shiiba M,Hayami K

    更新日期:1981-01-01 00:00:00

  • Low HDL Cholesterol and High Risk of Autoimmune Disease: Two Population-Based Cohort Studies Including 117341 Individuals.

    abstract:BACKGROUND:HDL is quantitatively the most important lipoprotein in most species and mechanistic evidence points toward a role for HDL in normal immune function. We tested the hypothesis that concentrations of HDL cholesterol are associated with risk of autoimmune disease. METHODS:From 2 studies of the general populati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.299636

    authors: Madsen CM,Varbo A,Nordestgaard BG

    更新日期:2019-05-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Do enzymatic analyses of serum triglycerides really need blanking for free glycerol?

    abstract::Distributions of concentrations of free glycerol in clinical plasma obtained for triglyceride assay were compiled to determine the frequency with which increased concentrations of free glycerol posed a potential problem for clinical interpretation of triglyceride results. Clinical histories were studied in patients wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jessen RH,Dass CJ,Eckfeldt JH

    更新日期:1990-07-01 00:00:00

  • Determination of cyclosporine concentrations with monoclonal antibodies.

    abstract::We measured cyclosporine in whole blood from normal volunteers administered single oral doses of the drug and from two renal-transplant patients on immunosuppressive maintenance therapy, by liquid chromatography (I) and by radioimmunoassay with use of nonspecific polyclonal (II), specific monoclonal (III), and nonspec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schran HF,Rosano TG,Hassell AE,Pell MA

    更新日期:1987-12-01 00:00:00

  • Critical assessment of phospholipid measurement in amniotic fluid.

    abstract::We assessed several methods of inorganic phosphate assay for their suitability in estimating phospholipids in digested extracts of amniotic fluids. The extraction and digestion procedures used for phospholipids from amniotic fluid were also examined critically. The effect of contamination by blood or obstetric cream h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Badham LP,Worth HG

    更新日期:1975-09-01 00:00:00

  • Quality-control (QC) performance measures and the QC planning process.

    abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Parvin CA

    更新日期:1997-04-01 00:00:00

  • Continuous determination of the oxygen dissociation curve for whole blood.

    abstract::We report here the development of a new method that allows continuous determination of the oxygen dissociation curve for microsamples (600 mul) of whole blood under conditions of pH, pCO2, methemoglobin concentration, and 2,3-diphosphoglycerate content closely approaching those found in the circulatory system. The met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rossi-Bernardi L,Luzzana M,Samaja M,Davi M,DaRiva-Ricci D,Minoli J,Seaton B,Berger RL

    更新日期:1975-11-01 00:00:00

  • Further studies on danazol interference in testosterone radioimmunoassays.

    abstract::Investigating the interference of danazol in testosterone radioimmunoassays, we measured serum testosterone concentrations in the serum of women receiving danazol, with three testosterone radioimmunoassay kits. All of these showed positive interference by danazol or its metabolites (or both). Values for testosterone o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sharp AM,Fraser IS,Caterson ID

    更新日期:1983-01-01 00:00:00

  • Liquid-chromatographic separation of urinary 5-hydroxy-3-indoleacetic acid, with measurement at 254 nm.

    abstract::A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Draganac PS,Steindel SJ,Trawick WG

    更新日期:1980-06-01 00:00:00

  • Precision of sensitivity estimations in diagnostic test evaluations. Power functions for comparisons of sensitivities of two tests.

    abstract::The precision of estimates of the sensitivity of diagnostic tests is evaluated. "Sensitivity" is defined as the fraction of diseased subjects with test values exceeding the 0.975-fractile of the distribution of control values. An estimate of the sensitivity is subject to sample variation because of variation of both c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Linnet K

    更新日期:1985-04-01 00:00:00

  • Pediatric and perinatal reference intervals for immunoglobulin light chains kappa and lambda.

    abstract::In routine analysis for immunoglobulin light chains in pediatric diagnostics, the age-related reference intervals for serum kappa (kappa) and lambda (lambda) light chains were evaluated in 1543 healthy subjects (newborns to age 16 years, including 168 premature infants). Light-chain analysis was performed by rate neph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herkner KR,Salzer H,Böck A,Mühl A,Tsaka T,Steger H,Pollak A,Schatten C,Popp W,Huber-Spitzy V

    更新日期:1992-04-01 00:00:00

  • Use of a programmable desk-top calculator for the statistical quality control of radioimmunoassays.

    abstract::We have developed an interactive statistical quality-control system for the small- to medium-sized radioimmunoassay laboratory, which can be used in a programmable desk-top calculator instead of the medium- or large-scale computer systems usually required. The design of this quality-control system is modeled after the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cernosek SF Jr,Gutierrez-Cernosek RM

    更新日期:1978-07-01 00:00:00

  • LOX index, a novel predictive biochemical marker for coronary heart disease and stroke.

    abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140707

    authors: Inoue N,Okamura T,Kokubo Y,Fujita Y,Sato Y,Nakanishi M,Yanagida K,Kakino A,Iwamoto S,Watanabe M,Ogura S,Otsui K,Matsuda H,Uchida K,Yoshimoto R,Sawamura T

    更新日期:2010-04-01 00:00:00

  • Completeness of Reporting of Systematic Reviews of Diagnostic Test Accuracy Based on the PRISMA-DTA Reporting Guideline.

    abstract:BACKGROUND:We evaluated the completeness of reporting of diagnostic test accuracy (DTA) systematic reviews using the recently developed Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA)-DTA guidelines. METHODS:MEDLINE® was searched for DTA systematic reviews published October 2017 to January 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2018.292987

    authors: Salameh JP,McInnes MDF,Moher D,Thombs BD,McGrath TA,Frank R,Dehmoobad Sharifabadi A,Kraaijpoel N,Levis B,Bossuyt PM

    更新日期:2019-02-01 00:00:00

  • A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates.

    abstract::We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thomson S,Wallace AM,Cook B

    更新日期:1989-08-01 00:00:00

  • Evaluation of pteroylglutamic acid and n-5-methyltetrahydrofolic acid reference standards in a new "No-Boil" radioassay for serum folate.

    abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Theobald RA,Batchelder M,Sturgeon MF

    更新日期:1981-04-01 00:00:00

  • Effects of storage time and temperature on urinary enzymes.

    abstract::We measured three renal tubular brush-border enzymes (lactate dehydrogenase, LDH, EC 1.1.1.27; gamma-glutamyltransferase, GGT, EC 2.3.2.2; and alkaline phosphatase, AP, EC 3.1.3.1) in morning urine samples from 48 healthy subjects to check whether different storage times and temperatures could modify enzyme concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matteucci E,Gregori G,Pellegrini L,Navalesi R,Giampietro O

    更新日期:1991-08-01 00:00:00

  • Application of the clearance concept to hyponatremic and hypernatremic disorders: a phenomenological analysis.

    abstract::The kidney and its response to the antidiuretic hormone (ADH) are the principal protective mechanisms necessary to maintain a normal plasma tonicity (osmolality). Hence, determination of the response of the ADH-renal axis to an abnormal plasma tonicity is an important step to understanding water homeostasis. Determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Shoker AS

    更新日期:1994-07-01 00:00:00

  • Detection of mitochondrial DNA mutations by temporal temperature gradient gel electrophoresis.

    abstract:BACKGROUND:A unique requirement for the molecular diagnosis of mitochondrial DNA (mtDNA) disorders is the ability to detect heteroplasmic mtDNA mutations and to distinguish them from homoplasmic sequence variations before further testing (e.g., sequencing) is performed. We evaluated the potential utility of temporal te...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Chen TJ,Boles RG,Wong LJ

    更新日期:1999-08-01 00:00:00

  • Variability of plasma lipids and lipoproteins: the Jerusalem Lipid Research Clinic Study.

    abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedlander Y,Kark JD,Stein Y

    更新日期:1985-07-01 00:00:00

  • Proteomic Discovery and Validation of the Confounding Effect of Heparin Administration on the Analysis of Candidate Cardiovascular Biomarkers.

    abstract:BACKGROUND:Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.282665

    authors: Beck HC,Jensen LO,Gils C,Ilondo AMM,Frydland M,Hassager C,Møller-Helgestad OK,Møller JE,Rasmussen LM

    更新日期:2018-10-01 00:00:00

  • Decreasing sample volume used in the "Sequential Multichannel Analyzer Computerized" (SMAC).

    abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stamper R,Robertshaw DM

    更新日期:1980-05-01 00:00:00

  • Genetic variants in the fibroblast growth factor pathway as potential markers of ovarian cancer risk, therapeutic response, and clinical outcome.

    abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.211490

    authors: Meng QH,Xu E,Hildebrandt MA,Liang D,Lu K,Ye Y,Wagar EA,Wu X

    更新日期:2014-01-01 00:00:00

  • The lipoprotein lipase HindIII polymorphism: association with total cholesterol and LDL-cholesterol, but not with HDL and triglycerides in 342 females.

    abstract:BACKGROUND:Lipoprotein lipase (LPL) is the rate-limiting enzyme in the hydrolysis of core triglycerides in chylomicrons and VLDL. METHODS:We investigated the association between the HindIII polymorphism of the LPL gene and fasting glucose, lipid, and lipoprotein concentrations in 683 Caucasians. We first stabilized th...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Larson I,Hoffmann MM,Ordovas JM,Schaefer EJ,März W,Kreuzer J

    更新日期:1999-07-01 00:00:00