Application of the clearance concept to hyponatremic and hypernatremic disorders: a phenomenological analysis.

Abstract:

:The kidney and its response to the antidiuretic hormone (ADH) are the principal protective mechanisms necessary to maintain a normal plasma tonicity (osmolality). Hence, determination of the response of the ADH-renal axis to an abnormal plasma tonicity is an important step to understanding water homeostasis. Determination of free water clearance is the most direct clinical method to measure the ability of the kidney to reabsorb or excrete water; it can be used as a sensitive method to study water metabolism, describing the abnormal water homeostasis in simple quantitative terms. A positive electrolyte-free water clearance denotes the excretion of excess free water. A negative electrolyte-free water clearance indicates reabsorption of excess free water. During hypertonicity, an increased concentration of ADH enhances renal reabsorption of free water. With diminished ADH secretion and normal renal function, a substantial volume of free water is cleared in response to hypotonic stimuli. A positive free water clearance > 0.4 L/day in hypertonic conditions or a negative free water clearance during hypotonicity confirms an abnormal ADH-renal axis response.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Shoker AS

subject

Has Abstract

pub_date

1994-07-01 00:00:00

pages

1220-7

issue

7 Pt 1

eissn

0009-9147

issn

1530-8561

journal_volume

40

pub_type

杂志文章,评审
  • Traceability in laboratory medicine.

    abstract:BACKGROUND:In patient and population samples, generation of analytical results that are comparable and independent of the measurement system, time, and location is essential for the utility of laboratory information supplied in healthcare. Obtaining analytical measurement results with such characteristics is the aim of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.107052

    authors: Vesper HW,Thienpont LM

    更新日期:2009-06-01 00:00:00

  • Effect of daylight on the reaction of thiols with Ellman's reagent, 5,5'-dithiobis(2-nitrobenzoic acid).

    abstract::The reaction of 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB, Ellman's reagent) with thiols is sensitive to daylight, in particular to ultraviolet radiation at wavelengths around 325 nm. Exposure to light at the absorbance maximum of the yellow product (the thionitrobenzoate ion) at 410 nm had no effect on the reaction. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Walmsley TA,Abernethy MH,Fitzgerald HP

    更新日期:1987-10-01 00:00:00

  • Sensitive, direct colorimetric assay for copper in serum.

    abstract::We have developed a sensitive procedure for determination of serum copper by use of the color reagent 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-sulfopropylaniline. After mixing serum sample and reagent, and incubating at 37 degrees C for 5 min, we measure the absorbance of the resulting chelate complex at 580 nm (molar a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Yamashita S,Noma A

    更新日期:1989-04-01 00:00:00

  • Efficient cleavage of conjugates of drugs or poisons by immobilized beta-glucuronidase and arylsulfatase in columns.

    abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toennes SW,Maurer HH

    更新日期:1999-12-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • Chemical and immunochemical measurement of total iron-binding capacity compared.

    abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Lewis SA,Iosefsohn M,Hicks JM

    更新日期:1978-10-01 00:00:00

  • Prostate-specific antigen: a cancer fighter and a valuable messenger?

    abstract:BACKGROUND:Prostate-specific antigen (PSA) is a valuable prostatic cancer biomarker that is now widely used for population screening, diagnosis, and monitoring of patients with prostate cancer. Despite the voluminous literature on this biomarker, relatively few reports have addressed the issue of its physiological func...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Diamandis EP

    更新日期:2000-07-01 00:00:00

  • Measurement of corticotropin in unextracted plasma: comparison of a time-resolved immunofluorometric assay and an immunoradiometric assay, with use of the same monoclonal antibodies.

    abstract::We describe a time-resolved immunofluorometric assay (IFMA) for corticotropin in unextracted human plasma, based on the use of two monoclonal antibodies: europium-labeled antibody 1A12 and antibody 2A3 coated onto microtiter wells. We compared the results of this assay with those of an immunoradiometric assay (IRMA) p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dobson S,White A,Hoadley M,Lovgren T,Ratcliffe J

    更新日期:1987-10-01 00:00:00

  • Bioassay of thyroid-stimulating immunoglobulin in cryopreserved human thyroid cells: optimization and clinical evaluation.

    abstract::We have explored the method of Rapoport et al. (J Clin Endocrinol Metab 1984;58:332-8) for the bioassay of thyroid-stimulating immunoglobulin (TSI) in cultured human thyroid cells, to optimize the assay and to evaluate its utility in clinical diagnosis and management of patients with autoimmune thyroid disease. Here w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kraiem Z,Glaser B,Pauker J,Sadeh O,Sheinfeld M

    更新日期:1988-02-01 00:00:00

  • Rapid Zeeman atomic absorption determination of copper in serum and urine.

    abstract::In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang ST,Demshar HP

    更新日期:1993-09-01 00:00:00

  • Coffee consumption and circulating B-vitamins in healthy middle-aged men and women.

    abstract:BACKGROUND:Coffee consumption has been associated with several risk factors for coronary heart disease, including increased cholesterol, increased blood pressure, and increased plasma total homocysteine (tHcy). tHcy is determined by several B-vitamins. However, reports about the association between coffee intake and B-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103465

    authors: Ulvik A,Vollset SE,Hoff G,Ueland PM

    更新日期:2008-09-01 00:00:00

  • Enzymic inhibition assay for methotrexate with a discrete analyzer, the ABA-100.

    abstract::We adapted an inhibition assay for methotrexate, involving dihydrofolate reductase from bovine liver, for use with a discrete analyzer (the ABA-100). The analyzer was used both for dilution and a 5-min pre-incubation of the sample with NADPH--enzyme reagent, and for the assay itself. The standard curve was linear betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown LF,Johnson GF,Witte DL,Feld RD

    更新日期:1980-02-01 00:00:00

  • Laboratory values in fit aging individuals--sexagenarians through centenarians.

    abstract::We determined approximately 15,000 laboratory values in 236 individuals between the ages of 60 and 90 y, 22 individuals between 90 and 99 y, and 69 individuals greater than or equal to 100 y, and compared these with values in young adults. We tested 47 different analytes in the 60-90-y group and 93 analytes in the gre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tietz NW,Shuey DF,Wekstein DR

    更新日期:1992-06-01 00:00:00

  • Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

    abstract::We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Srinivasan SR,Foster TA,Berenson GS

    更新日期:1980-10-01 00:00:00

  • Cardiac troponin T predicts long-term outcomes in hemodialysis patients.

    abstract:BACKGROUND:Increased plasma troponin T (cTnT), but not troponin I (cTnI), is frequently observed in end-stage renal failure patients. Although generally considered spurious, we previously reported an associated increased mortality at 12 months. METHODS:We studied long-term outcomes in 244 patients on chronic hemodialy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ooi DS,Zimmerman D,Graham J,Wells GA

    更新日期:2001-03-01 00:00:00

  • Studies of the reliability of constituent target values established in a large inter-laboratory survey.

    abstract::Lyophilized serum specimens were manufactured in such a way that fixed quantitative interspecimen relationships were established. The specimens were analyzed for about twenty constituents by several thousand laboratories in 1971, 1972, and 1973. Most of the consensus mean values derived from these analyses were found ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Grannis GF

    更新日期:1976-07-01 00:00:00

  • Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration.

    abstract:BACKGROUND:Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.176545

    authors: Heijboer AC,Blankenstein MA,Kema IP,Buijs MM

    更新日期:2012-03-01 00:00:00

  • Effect of stripping thyroxin from thyroxin-binding globulin on the measurement of free thyroxin in serum by equilibrium dialysis and by radioimmunoassay.

    abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakagawa T,Matsumura K,Takeda K,Shinoda N,Matsuda A,Matsushita T,Tagami T

    更新日期:1990-02-01 00:00:00

  • Two-site immunoenzymometric assay for thyrotropin in dried blood samples on filter paper.

    abstract::We describe a sensitive, simple, and rapid two-site immunoenzymometric assay for thyrotropin in dried blood samples on filter paper, for use in screening for neonatal primary hypothyroidism. In this method, two dried-blood spots of 3 mm diameter (equivalent to about 5.4 microliter of blood) are incubated overnight wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miyai K,Ishibashi K,Kawashima M

    更新日期:1981-08-01 00:00:00

  • A homogeneous fluorescent immunoassay for human immunoglobulin M.

    abstract::We describe a homogeneous substrate-labeled fluorescent immunoassay for human IgM. In this competitive-binding method we use a fluorogenic substrate for Escherichia coli beta-galactosidase, N-(6-aminohexyl)-7-beta-galactosyl-coumarin-3-carboxamide, which is covalently coupled to IgM. The fluorescence emission intensit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Worah D,Yeung KK,Ward FE,Carrico RJ

    更新日期:1981-05-01 00:00:00

  • Size separation of circulatory DNA in maternal plasma permits ready detection of fetal DNA polymorphisms.

    abstract:BACKGROUND:Analysis of fetal DNA in maternal plasma has recently been introduced as a new method for noninvasive prenatal diagnosis, particularly for the analysis of fetal genetic traits, which are absent from the maternal genome, e.g., RHD or Y-chromosome-specific sequences. To date, the analysis of other fetal geneti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.029835

    authors: Li Y,Zimmermann B,Rusterholz C,Kang A,Holzgreve W,Hahn S

    更新日期:2004-06-01 00:00:00

  • Quantification of fragments of human serum inter-alpha-trypsin inhibitor heavy chain 4 by a surface-enhanced laser desorption/ionization-based immunoassay.

    abstract:BACKGROUND:Several proteolytically derived fragments from the proline-rich region (PRR) of human inter-alpha-trypsin inhibitor heavy chain 4 (ITIH4) have been identified by surface-enhanced or matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS or MALDI-TOF-MS) as potential diseas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065722

    authors: Song J,Patel M,Rosenzweig CN,Chan-Li Y,Sokoll LJ,Fung ET,Choi-Miura NH,Goggins M,Chan DW,Zhang Z

    更新日期:2006-06-01 00:00:00

  • Diet-related reference values for plasma amino acids in newborns measured by reversed-phase HPLC.

    abstract::We have measured by reversed-phase HPLC concentrations of amino acids in plasma in groups of 80 normal appropriate-weight term babies fed from birth either a casein formula (WhiteCap SMA, n = 26), a whey formula (Gold Cap SMA, n = 26), or breast milk (n = 28). They were studied from day 11 to week 15 postpartum. The t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Scott PH,Sandham S,Balmer SE,Wharton BA

    更新日期:1990-11-01 00:00:00

  • Utility of oligonucleotide array-based comparative genomic hybridization for detection of target gene deletions.

    abstract:BACKGROUND:direct DNA sequencing is the primary clinical technique for identifying mutations in human disease, but sequencing often does not detect intragenic or whole-gene deletions. Oligonucleotide array-based comparative genomic hybridization (CGH) is currently in clinical use to detect major changes in chromosomal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103721

    authors: Wong LJ,Dimmock D,Geraghty MT,Quan R,Lichter-Konecki U,Wang J,Brundage EK,Scaglia F,Chinault AC

    更新日期:2008-07-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • Prognostic Utility of Galectin-3 for Recurrent Cardiovascular Events During Long-term Follow-up in Patients with Stable Coronary Heart Disease: Results of the KAROLA Study.

    abstract:BACKGROUND:Galectin-3 has emerged as a potential useful novel biomarker for heart failure and cardiovascular disease (CVD). However, it remains unclear whether galectin-3 is associated with recurrent cardiovascular events during long-term follow-up of patients with stable coronary heart disease (CHD) after adjustment f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.257550

    authors: Jansen H,Koenig W,Jaensch A,Mons U,Breitling LP,Scharnagl H,Stojakovic T,Schunkert H,Brenner H,Rothenbacher D

    更新日期:2016-10-01 00:00:00

  • Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations.

    abstract:BACKGROUND:Specific gravity (SG) may perform as well as creatinine (CR) correction for adjusting urinary hormone concentrations, as well as offer some advantages. We compared the two methods and applied them to US and Bangladeshi specimens to evaluate their use in different populations. METHODS:Pearson correlations be...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.032292

    authors: Miller RC,Brindle E,Holman DJ,Shofer J,Klein NA,Soules MR,O'Connor KA

    更新日期:2004-05-01 00:00:00

  • Modifying an enzyme immunoassay of immunoreactive trypsinogen to use time-resolved fluorescence.

    abstract::A coated microtiter-well, enzyme-linked immunometric assay for quantifying immunoreactive trypsinogen in dried blood spots was modified to use time-resolved fluorescence of europium in place of end-point enzymatic color development as the quantification step. The streptavidin-horseradish peroxidase and color developme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ryall RG,Gjerde EM,Gerace RL,Ranieri E

    更新日期:1993-02-01 00:00:00

  • Decreasing sample volume used in the "Sequential Multichannel Analyzer Computerized" (SMAC).

    abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stamper R,Robertshaw DM

    更新日期:1980-05-01 00:00:00

  • Estimating fat in feces by near-infrared reflectance spectroscopy.

    abstract::We describe use of near-infrared reflectance spectroscopy (NIRRS) to estimate the amount of fat in feces, for diagnosis of steatorrhea. After sample homogenization, the spectrum of the fecal homogenate is scanned over the near-infrared region. Assay of 94 samples of feces having a known concentration of fat showed the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koumantakis G,Radcliff FJ

    更新日期:1987-04-01 00:00:00