Cardiac troponin T predicts long-term outcomes in hemodialysis patients.

Abstract:

BACKGROUND:Increased plasma troponin T (cTnT), but not troponin I (cTnI), is frequently observed in end-stage renal failure patients. Although generally considered spurious, we previously reported an associated increased mortality at 12 months. METHODS:We studied long-term outcomes in 244 patients on chronic hemodialysis for up to 34 months, correlating the outcomes to plasma cTnT in routine predialysis samples. In addition, subsequent plasma samples at least 1 year later and within 6 months of data analysis were available in 97 patients and were used to identify patients with increasing plasma cTnT. The endpoints used were death and new or worsening coronary, cerebro-, and peripheral vascular disease and neuropathy. RESULTS:Transplantation occurred more frequently in patients with low initial cTnT: 31%, 13%, and 3% in the groups with cTnT < 0.010, 0.010-0.099, and > or = 0.100 microg/L, respectively. In the same groups, total deaths occurred in 6%, 43%, and 59% and cardiac deaths in 0%, 14%, and 24% of patients. In patients with follow-up samples, the group with increasing cTnT had a significantly increased death (relative risk, 2.0; P = 0.028). The increase was mainly in cardiac and sudden deaths. CONCLUSIONS:Higher plasma cTnT predicts long-term all-cause mortality in hemodialysis patients, even at concentrations < 0.100 microg/L, as does an increasing cTnT concentration over time.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Ooi DS,Zimmerman D,Graham J,Wells GA

subject

Has Abstract

pub_date

2001-03-01 00:00:00

pages

412-7

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

47

pub_type

杂志文章
  • Diagnostic utility of C-terminal parathyrin measurement as compared with measurements of N-terminal parathyrin and calcium in serum.

    abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simon M,Cuan J

    更新日期:1980-11-01 00:00:00

  • Immunological measurement of transforming growth factor-beta 1 (TGF-beta1) in blood; assay development and comparison.

    abstract::Development of a new, sensitive immunoassay for measuring transforming growth factor beta 1 (TGF-beta1) is described and compared with four commercially available TGF-beta1 immunoassays. Preanalytical conditions were evaluated. The nonlinearity found in serum or plasma is due to masking of TGF-beta1 by binding protein...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kropf J,Schurek JO,Wollner A,Gressner AM

    更新日期:1997-10-01 00:00:00

  • Comparison of quality-control rules used in clinical chemistry laboratories.

    abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bishop J,Nix AB

    更新日期:1993-08-01 00:00:00

  • Up-dated catalogue of HeLa cell proteins: percentages and characteristics of the major cell polypeptides labeled with a mixture of 16 14C-labeled amino acids.

    abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bravo R,Celis JE

    更新日期:1982-04-01 00:00:00

  • An optimized continuous-monitoring procedure for semiautomated determination of serum acid phosphatase activity.

    abstract::A continuous-monitoring method for measuring acid phosphatase activity with alpha-naphthyl phosphate as the substrate was critically evaluated and modified. Using partially purified prostatic acid phosphatase, we show that certain conditions for the assay must be satisfied to ensure linearity. These conditions include...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bais R,Edwards JB

    更新日期:1976-12-01 00:00:00

  • Performance evaluation and subsequent clinical experience with the Abbott Automated Architect STAT Troponin-I assay.

    abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.057216

    authors: Lam Q,Black M,Youdell O,Spilsbury H,Schneider HG

    更新日期:2006-02-01 00:00:00

  • Evidence that the amino-terminal composition of non-(1-84) parathyroid hormone fragments starts before position 19.

    abstract:BACKGROUND:Non-(1-84) parathyroid hormone (PTH) fragments are large C-terminal fragments of PTH with a partially preserved N-terminal structure. They differ from other C-terminal PTH fragments, which do not have an N-terminal structure and do not react in intact PTH assays. We aimed to identify the minimal N-terminal s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.040485

    authors: D'Amour P,Brossard JH,Räkel A,Rousseau L,Albert C,Cantor T

    更新日期:2005-01-01 00:00:00

  • Gas-chromatographic analysis for 1,2:5,6-dianhydrogalactitol, an anti-neoplastic agent, in plasma.

    abstract::We describe a gas chromatographic method for measuring submicrogram quantities of dianhydrogalactitol, a promising antineoplastic agent (currently undergoing clinical trials in humans), in plasma. The drug is first extracted from blood plasma by saturating the aqueous phase with solid potassium carbonate and extractin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kimura T,Sternson LA,Higuchi T

    更新日期:1976-10-01 00:00:00

  • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC.

    abstract::Assays with different specificity are used for cyclosporin monitoring in clinical transplantation. A recent survey of 35 centers showed that 86% used immunoassays for cyclosporin A (CsA). In consensus documents the following performance criteria were recommended: (a) imprecision < or = 10% at 50 microg/L and < or = 5%...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schütz E,Svinarov D,Shipkova M,Niedmann PD,Armstrong VW,Wieland E,Oellerich M

    更新日期:1998-10-01 00:00:00

  • Antibodies to casein kinase II in sera of patients with mixed connective tissue disease: evaluation with recombinant proteins.

    abstract::In this study we determined the prevalence of autoantibodies against casein kinase II (CKII) in patients positive for anti-70K marker antibodies, which is indicative of mixed connective tissue disease. An anti-CKII ELISA was established with the use of bacterially expressed recombinant CKII proteins. Eight out of 52 a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wiemann C,Bodenbach L,Pyerin W

    更新日期:1993-12-01 00:00:00

  • Low apparent creatine kinase activity and prolonged lag phases in serum of patients with metastatic disease: elimination by treatment of sera with sulfhydryl agents.

    abstract::We find lag phases exceeding 20 min in measuring creatine kinase activity, by using the kinetic creatin phosphate leads to creatine assay, in sera of some patients with carcinoma metastatic to the liver. Such long lag phases are accompanied by a decreased apparent enzyme activity. These problems are eliminated by addi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Morgan WS,Davis JE,Ladenson JH

    更新日期:1976-11-01 00:00:00

  • Multiple drugs of abuse in urine detected with a single reagent and fluorescence polarization.

    abstract::We describe a simple polarization fluoroimmunoassay for the detection of several commonly abused drugs in urine. The single reagent used, prepared by mixing four different antisera and three fluorescein-labeled derivatives, produces a polarization signal that is the average of the individual signals of the derivatives...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Childerstone M

    更新日期:1987-10-01 00:00:00

  • Evaluation of the Beckman creatinine analyzer.

    abstract::We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hicks JM,Iosefsohn M,Lewis SA

    更新日期:1979-06-01 00:00:00

  • Growth hormone (GH) receptor isoform in acromegaly: lower concentrations of GH but not insulin-like growth factor-1 in patients with a genomic deletion of exon 3 in the GH receptor gene.

    abstract:BACKGROUND:A genomic deletion of exon 3 (d3-GHR) of the growth hormone (GH) receptor (GHR) has been linked to the effectiveness of GH therapy in children with GH deficiency. Carriers of the d3-GHR genotype had higher GH-induced growth rates than children homozygous for the full-length (fl)-GHR. The aim of this study wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.085712

    authors: Schmid C,Krayenbuehl PA,Bernays RL,Zwimpfer C,Maly FE,Wiesli P

    更新日期:2007-08-01 00:00:00

  • Changes in magnesium, zinc, calcium, potassium, cholesterol, and creatine kinase concentrations in patients from pre-infarction syndrome to fatal myocardial infarction.

    abstract::We measured changes in concentrations of magnesium, zinc, calcium, potassium, cholesterol [total and high-density lipoproteins (HDL)], total creatine kinase (CK), and CK isoenzyme-MB in plasma (PI) and/or erythrocytes (Erc) from apparently healthy subjects and from patients with either pre-infarction syndrome (PIS) or...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Speich M,Gelot S,Arnaud P,Nicolas G

    更新日期:1988-10-01 00:00:00

  • Effect of carbon cup aging on plasma zinc determination by flameless atomic adosorption spectrometry.

    abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chooi MK,Todd JK,Boyd ND

    更新日期:1975-04-01 00:00:00

  • A direct radioimmunoassay for aldosterone in plasma.

    abstract::This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with 125I-labeled aldosterone as the labeled antigen. Our use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lun S,Espiner EA,Nicholls MG,Yandle TG

    更新日期:1983-02-01 00:00:00

  • Rapid Zeeman atomic absorption determination of copper in serum and urine.

    abstract::In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang ST,Demshar HP

    更新日期:1993-09-01 00:00:00

  • Electrophoretic patterns for serum glycoproteins reflect the presence of human breast cancer.

    abstract::We describe a group of glycoproteins that are synthesized and released by human breast tumors maintained in organ culture and similar glycoproteins released by a human breast carcinoma cell line (BT-20). The electrophoretic mobility of these glycoproteins on cellulose acetate is consistent with increased glycoprotein-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Tökes ZA

    更新日期:1977-11-01 00:00:00

  • Troponin I in patients without chest pain.

    abstract:BACKGROUND:Testing for troponin has important clinical value for patients who present with typical symptoms of acute coronary syndromes (ACS) such as chest pain (CP). Much less is known about the value of troponin testing for patients who present with other symptoms of ACS (anginal equivalent symptoms). METHODS:The ut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.016311

    authors: Ritter D,Lee PA,Taylor JF,Hsu L,Cohen JD,Chung HD,Virgo KS

    更新日期:2004-01-01 00:00:00

  • Radioimmunoassay of metanephrine and normetanephrine for diagnosis of pheochromocytoma.

    abstract::Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immun...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iinuma K,Ikeda I,Ogihara T,Hashizume K,Kurata K,Kumahara Y

    更新日期:1986-10-01 00:00:00

  • Detection of intracellular antigens by flow cytometry: comparison of two chemical methods and microwave heating.

    abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Millard I,Degrave E,Philippe M,Gala JL

    更新日期:1998-11-01 00:00:00

  • Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.

    abstract::This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bowers GN Jr,Brassard C,Sena SF

    更新日期:1986-08-01 00:00:00

  • Substantial urinary concentrations of material resembling beta-core fragment of chorionic gonadotropin beta-subunit in mid-menstrual cycle.

    abstract::We measured the day-to-day variations in concentrations of beta-core, luteinizing hormone (LH), and alpha-subunit in urine during the menstrual cycle. The alpha-subunit concentrations showed a pattern similar to that of the LH concentrations. beta-Core-like material was increased during and up to 3 to 4 days after the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neven P,Iles RK,Howes I,Sharma K,Shepherd JH,Edwards R,Collins WP,Chard T

    更新日期:1993-09-01 00:00:00

  • Ion chromatography: a new technique for clinical chemistry.

    abstract::Ion chromatography is a new analytical technique in which the ions to be analyzed are separated on a special pellicular ion-exchange column. Once separated, the effluent from the separating column passes into a second ion-exchange column, which removes the eluent or buffer ions from the moving phase without removing t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anderson C

    更新日期:1976-09-01 00:00:00

  • New immunoenzymatic assay for human thyrotropin compared with two radioimmunoassays.

    abstract::We have evaluated a new immunoenzymatic assay for human thyrotropin involving three monoclonal antibodies (Abbott HTSH EIA) and compared the results with those of two conventional nonequilibrium double-antibody radioimmunoassay (RIA) methods: Clinical Assays' RIA and a research RIA (J Clin Endocrinol Metab 1975; 41:67...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Turner LF Jr,Hershman JM

    更新日期:1986-03-01 00:00:00

  • Gas-liquid chromatographic profile of neutral and acidic metabolites in cerebrospinal fluid from newborns and infants.

    abstract::A profile (chromatographic pattern) of the neutral and acidic metabolites present in cerebrospinal fluid from newborns and infants was obtained by gas-liquid chromatography. The metabolites are those extracted with ethyl acetate and diethyl ether. They are converted to trimethylsilyl ether derivatives, and chromatogra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Malcolm RD,Leonards R

    更新日期:1976-05-01 00:00:00

  • AccuMeter noninstrumented quantitative assay of high-density lipoprotein in whole blood.

    abstract::A novel noninstrumented technology (ChemTrak AccuMeter) for the quantitative measurement of analytes in biological fluids was reported at the 1990 Oak Ridge Conference (Clin Chem 1990;36:1591-7). This instrument-free technology has been adapted for the quantitative measurement of high-density lipoprotein (HDL). An in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Liu VY,Lin TY,Schrier W,Allen M,Singh P

    更新日期:1993-09-01 00:00:00

  • Serum prostate-specific acid phosphatase: development and validation of a specific radioimmunoassay.

    abstract::We describe radioimmunoassay for human prostatic acid phosphatase [orthophosphoric-monoester phospho-hydrolase (acid optimum), EC 3.1.3.2] in serum, with use of monospecific antisera raised in rabbits against highly purified acid phosphatase from human prostates. The antiserum did not cross react with partly purified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vihko P,Sajanti E,Jänne O,Peltonen L,Vihko R

    更新日期:1978-11-01 00:00:00

  • Correlation between estrogen receptor protein and carcinoembryonic antigen in normal and carcinomatous human breast tissue.

    abstract::We determined estrogen receptor protein and carcinoembryonic antigen in cytosols prepared from 189 human breast carcinoma tissues, 85 benign or normal breast biopsies, and 101 tissue specimens metastatic from breast carcinoma. Carcinoembryonic antigen was observed in 70% of the primary carcinomatous tissues, 15% of th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Menendez-Botet CJ,Nisselbaum JS,Fleisher M,Rosen PP,Fracchia A,Robbins G,Urban JA,Schwartz MK

    更新日期:1976-08-01 00:00:00