Sensitive, direct colorimetric assay for copper in serum.

Abstract:

:We have developed a sensitive procedure for determination of serum copper by use of the color reagent 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-sulfopropylaniline. After mixing serum sample and reagent, and incubating at 37 degrees C for 5 min, we measure the absorbance of the resulting chelate complex at 580 nm (molar absorptivity, 80,000 L.mol-1.cm-1). Results of the method varied linearly with copper concentration to at least 5 mg/L; the lower limit of detection was 0.1 mg/L. Within-run CVs were 1.6% and 3.3% for copper concentrations of 1.03 and 0.72 mg/L, respectively (n = 10 each). Between-run CV was 2.8% at 1.22 mg/L (n = 14). Results of the proposed method (y) correlated well with those determined by standard atomic absorption spectrophotometric techniques (x): y = 0.99x - 0.02 mg/L; Syx = 0.08; r = 0.977; n = 56. Iron, zinc, cadmium, cobalt, and lead do not interfere.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Abe A,Yamashita S,Noma A

subject

Has Abstract

pub_date

1989-04-01 00:00:00

pages

552-4

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Thyroxine-binding globulin capacity and concentration evaluated from blood spots on filter-paper in a screening program for neonatal hypothyroidism.

    abstract::We describe a simple method for evaluating thyroxine-binding globulin capacity and concentration from a single 1-cm blood spot on filter-paper used in a screening program for neonatal hypothyroidism. This method permits prompt diagnosis of about 90% of the infants with thyroxine-binding globulin deficiency in our abno...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dussault JH,Morissette J,Letarte J,Guyda H,Laberge C

    更新日期:1980-03-01 00:00:00

  • Abbott TDx monoclonal antibody assay evaluated for measuring cyclosporine in whole blood.

    abstract::We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yatscoff RW,Copeland KR,Faraci CJ

    更新日期:1990-11-01 00:00:00

  • Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. METHODS:We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103846

    authors: Shiraishi S,Lee PW,Leung A,Goh VH,Swerdloff RS,Wang C

    更新日期:2008-11-01 00:00:00

  • A Mendelian Randomization-Based Approach to Identify Early and Sensitive Diagnostic Biomarkers of Disease.

    abstract:BACKGROUND:Identifying markers of chronic kidney disease (CKD) that occur early in the disease process and are specific to loss of kidney function rather than other underlying causes of disease may allow earlier, more accurate identification of patients who will develop CKD. We therefore sought to identify diagnostic b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.291104

    authors: Mohammadi-Shemirani P,Sjaarda J,Gerstein HC,Treleaven DJ,Walsh M,Mann JF,McQueen MJ,Hess S,Paré G

    更新日期:2019-03-01 00:00:00

  • Low HDL Cholesterol and High Risk of Autoimmune Disease: Two Population-Based Cohort Studies Including 117341 Individuals.

    abstract:BACKGROUND:HDL is quantitatively the most important lipoprotein in most species and mechanistic evidence points toward a role for HDL in normal immune function. We tested the hypothesis that concentrations of HDL cholesterol are associated with risk of autoimmune disease. METHODS:From 2 studies of the general populati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.299636

    authors: Madsen CM,Varbo A,Nordestgaard BG

    更新日期:2019-05-01 00:00:00

  • Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

    abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Gerhardt W,Nordin G,Herbert AK,Burzell BL,Isaksson A,Gustavsson E,Haglund S,Müller-Bardorff M,Katus HA

    更新日期:2000-06-01 00:00:00

  • Radioimmunoassay of cortisone in serum, urine, and saliva to assess the status of the cortisol-cortisone shuttle.

    abstract::We have developed a new assay for cortisone (E) in serum, saliva, and urine involving Celite chromatography followed by RIA with 125I-labeled E and scintillation proximity assay. The chromatography step separates cortisol (F) from E, and in combination with their RIAs, permits assessment of the status of the F-E shutt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morineau G,Boudi A,Barka A,Gourmelen M,Degeilh F,Hardy N,al-Halnak A,Soliman H,Gosling JP,Julien R,Brerault JL,Boudou P,Aubert P,Villette JM,Pruna A,Galons H,Fiet J

    更新日期:1997-08-01 00:00:00

  • DNA enzyme immunoassay: general method for detecting products of polymerase chain reaction.

    abstract::We developed a new colorimetric method, DNA enzyme immunoassay (DEIA), for detecting specific hybrids of complementary nucleic acids and applied it to the detection of hepatitis B virus (HBV) DNA amplified from serum samples by means of the polymerase chain reaction (PCR) technique. The method is based on the ability ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mantero G,Zonaro A,Albertini A,Bertolo P,Primi D

    更新日期:1991-03-01 00:00:00

  • Tartrate-resistant acid phosphatase isoform 5b as serum marker for osteoclastic activity.

    abstract:BACKGROUND:Tartrate-resistant acid phosphatase (AcP) 5b is a marker of osteoclastic activity and bone resorption. Immunoassays for serum TRAcP may lack sensitivity and specificity because of the presence of non-bone isoform 5a. The purpose of this study was to isolate the serum isoforms, quantify their disease-related ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Janckila AJ,Takahashi K,Sun SZ,Yam LT

    更新日期:2001-01-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00

  • The CAG repeat polymorphism in the androgen receptor gene is associated with HDL-cholesterol but not with coronary atherosclerosis or myocardial infarction.

    abstract:BACKGROUND:Age-adjusted morbidity and mortality rates from coronary heart disease (CHD) are higher in men than in women. Androgens are suspected to be responsible for the male disadvantage. The genomic effect of androgens is mediated by the androgen receptor (AR), which has a polymorphic CAG repeat in exon 1. The numbe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2005.049262

    authors: Hersberger M,Muntwyler J,Funke H,Marti-Jaun J,Schulte H,Assmann G,Lüscher TF,von Eckardstein A

    更新日期:2005-07-01 00:00:00

  • Fetal lung maturity, as assessed by gas-liquid chromatographic determination of phospholipid palmitic acid in amniotic fluid.

    abstract::We describe a new and specific method for measurement of lecithin palmitic acid in amniotic fluid. Dipalmitoyl lecithin, the major alveolar surfactant, has previously been estimated by measuring the lecithin-sphingomyelin ratio, total lecithin, total phospholipid phosphorus, and (or) total palmitic acid. Our method is...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ip MP,Draisey TF,Thibert RJ,Gagneja GL,Jasey GM

    更新日期:1977-01-01 00:00:00

  • A rapid, sensitive enzyme-linked immunoassay for human thyrotropin.

    abstract::In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tseng YC,Burman KD,Baker JR Jr,Wartofsky L

    更新日期:1985-07-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Comparison of calculated and measured free thyroid hormones in serum in health and in abnormal states.

    abstract::To evaluate a theoretical model for calculating free thyroid hormones, based on the law of mass action, we compared values for both calculated and measured free thyroxin and free triiodothyronine in a group of normal subjects. To determine whether the concentrations of circulating free hormones were also predictable f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fresco G,Curti G,Biggi A,Fontana B

    更新日期:1982-06-01 00:00:00

  • Microassay for nuclear binding of steroid receptors with use of intact cells from small samples of avian and human tissue.

    abstract::A micro version of a nuclear binding assay to assess the biological activity of receptors for steroid hormones was developed for application to small (needle) biopsies of human tumors for the purpose of predicting responses to steroid therapy. This easier assay requires 10-fold less tissue than the original nuclear bi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colvard DS,Jankus WR,Berg NJ,Graham ML 2nd,Jiang NS,Ingle JN,Spelsberg TC

    更新日期:1988-02-01 00:00:00

  • High-performance liquid chromatography of 125I-labeled mouse epidermal growth factor radioiodinated by six different methods.

    abstract::Six different procedures for radioiodination of mouse epidermal growth factor (EGF) all resulted in a heterogeneous 125I-labeled EGF preparation, as analyzed by reversed-phase HPLC. EGF preparations that had been iodinated with Chloramine T, lodogen, or lodo-beads were found mainly to consist of oxidized 125I-labeled ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kienhuis CB,Heuvel JJ,Ross HA,Foekens JA,Benraad TJ

    更新日期:1992-05-01 00:00:00

  • Microplate measurement of urinary albumin and creatinine.

    abstract::We describe microplate methods for measurement of human urinary albumin (HUA) by competitive enzyme-linked immunosorbant assay (ELISA) and creatinine with a modified commercial enzymatic kit. Incorporation of substrate mixing into the competitive ELISA changes the dynamic absorbance-concentration response, greatly sim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Magnotti RA Jr,Stephens GW,Rogers RK,Pesce AJ

    更新日期:1989-07-01 00:00:00

  • Multicenter harmonization of common enzyme results by fresh patient-pool sera.

    abstract::A region consisting of 19 clinical laboratories harmonized their calibration of seven common enzymes by using fresh patient-pool sera. One of the laboratories was chosen to act as Regional Reference Laboratory (RRL). This laboratory used internationally accepted (mostly IFCC) methods at 37 degrees C, with an intralabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Franck PF,Steen G,Lombarts AJ,Souverijn JH,van Wermeskerken RK

    更新日期:1998-03-01 00:00:00

  • Analytical problems facing the development of electrochemical transducers for in vivo drug monitoring: an overview.

    abstract::Even though significant progress has been made in the development of electrodes for the in vivo detection of catecholamines, oxygen, and various cations, there has been little research on the feasibility of continuously monitoring drugs in whole blood by electrochemical sensing devices. Electroanalytical problems asso...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pinkerton TC,Lawson BL

    更新日期:1982-09-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Failure of microchromatographic measurement of fetal hemoglobin in beta zero thalassemia-hereditary persistence of fetal hemoglobin.

    abstract::We report microchromatographic measurement of fetal hemoglobin (HbF) proportions in a 36-year-old African-American multigravida woman. At 34 weeks she delivered a 630-g male infant who subsequently did well. Hemoglobin electrophoresis of the hemolysate revealed nearly 100% HbF without HbA, an extremely unusual natural...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Krauss JS,Jonah MH,Devoe LD,Pantazis CG

    更新日期:1992-11-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A

    更新日期:1997-09-01 00:00:00

  • A model for molecular screening of newborns: simultaneous detection of Duchenne/Becker muscular dystrophies and cystic fibrosis.

    abstract::Gene mutations responsible for the majority of Duchenne/Becker muscular dystrophy (DMD/BMD) and cystic fibrosis (CF) chromosomes have been identified. We describe a DNA-based strategy, rather than the traditional biochemical assays, for screening newborns. DNA sequences spanning the CF mutation and several DMD/BMD del...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Prior TW,Highsmith WE Jr,Friedman KJ,Perry TR,Scheuerbrandt G,Silverman LM

    更新日期:1990-10-01 00:00:00

  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • Quantification of serum 1-84 parathyroid hormone in patients with hyperparathyroidism by immunocapture in situ digestion liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Immunoassays specific for 1-84 parathyroid hormone (PTH) reportedly reflect the bioactivity of PTH; however, PTH immunoassays can be susceptible to interference by cross-reacting PTH fragments. In addition, these assays currently lack standardization. A methodology using immunocapture purification with liqui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.134643

    authors: Kumar V,Barnidge DR,Chen LS,Twentyman JM,Cradic KW,Grebe SK,Singh RJ

    更新日期:2010-02-01 00:00:00

  • Immobilization of immunoglobulins onto surface-treated and untreated polystyrene beads for radioimmunoassays.

    abstract::The immunoreactivity of anti-triiodothyronine (anti-T3) IgG, pretreated at acidic pH and adsorbed onto polystyrene beads, was significantly greater than that determined for native anti-T3 IgG immobilized at optimum pH 3.5. Acidic-pH-pretreated IgG, adsorbed at pH 7.0 onto ethanol-treated beads, had less immunoreactivi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kakabakos SE,Livanlou E,Evangelatos GP,Ithakissios DS

    更新日期:1990-03-01 00:00:00

  • Carboxyhemoglobin, cotinine, and thiocyanate assay compared for distinguishing smokers from non-smokers.

    abstract::We compared cotinine, carboxyhemoglobin, and thiocyanate concentrations in blood sampled from 187 cigarette smokers and 181 non-smokers. All three differed significantly between smokers and non-smokers. Cotinine performed best as a test for assessing smoking status, with a sensitivity of 98% as compared with 94% for c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pojer R,Whitfield JB,Poulos V,Eckhard IF,Richmond R,Hensley WJ

    更新日期:1984-08-01 00:00:00

  • Creatine kinase BB: a new tumor-associated marker.

    abstract::Creatine kinase isoenzyme BB (CK-BB) is found in the serum of patients with various types of cancer. Using both radioimmunoassay and agarose electrophoresis, we found abnormal amounts of this isoenzyme in the serum of 15 of 17 patients with untreated prostatic carcinoma. Among patients with other types of adenocarcino...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Zweig MH,Van Steirteghem AC,Tökés ZA

    更新日期:1979-08-01 00:00:00