Immobilization of immunoglobulins onto surface-treated and untreated polystyrene beads for radioimmunoassays.

Abstract:

:The immunoreactivity of anti-triiodothyronine (anti-T3) IgG, pretreated at acidic pH and adsorbed onto polystyrene beads, was significantly greater than that determined for native anti-T3 IgG immobilized at optimum pH 3.5. Acidic-pH-pretreated IgG, adsorbed at pH 7.0 onto ethanol-treated beads, had less immunoreactivity than that on untreated beads and gave values similar to those of native IgG adsorbed onto activated beads at pH 9.6. The rate of immobilization onto treated beads was significantly greater than onto untreated ones, and the binding was reproducible (intra- and inter-batch coating CV, 3.7-4.6% and 7.2%, respectively) and very resistant to successive washings. A post-washing incubation in 10 mg/L bovine serum albumin solution was required to eliminate the decreased immobilized immunoreactivity caused by some washing reagents. For solid-phase radioimmunoassays of T3, 40% less antibody was needed when acidic-pH-pretreated IgG was adsorbed onto untreated beads or when native IgG was adsorbed onto ethanol-treated beads, in comparison with native IgG adsorbed onto untreated beads. Results and assay characteristics with such beads were comparable with results for solid-phase and liquid-phase polyethylene glycol assay of T3.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Kakabakos SE,Livanlou E,Evangelatos GP,Ithakissios DS

subject

Has Abstract

pub_date

1990-03-01 00:00:00

pages

492-6

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

36

pub_type

杂志文章
  • Differential patterns of bone turnover in relation to bone pain and disease extent in bone in cancer patients with skeletal metastases.

    abstract:BACKGROUND:The alteration of the bone microenvironment as a consequence of skeletal metastases is poorly understood. The aim of this study was to search for patterns of bone markers in relation to primary tumor type, bone pain, and number of sites involved in patients with bone metastases. METHODS:We studied 323 patie...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Berruti A,Dogliotti L,Gorzegno G,Torta M,Tampellini M,Tucci M,Cerutti S,Frezet MM,Stivanello M,Sacchetto G,Angeli A

    更新日期:1999-08-01 00:00:00

  • Flow-cytometric determination of high-density-lipoprotein binding sites on human leukocytes.

    abstract::In this method, leukocytes were isolated from 6 mL of EDTA-blood by density-gradient centrifugation and subsequently incubated with rhodamine isothiocyanate (RITC)-conjugated high-density lipoproteins (HDL). The receptor-bound conjugate particles were determined by fluorescent flow cytometry and compared with 125I-lab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schmitz G,Wulf G,Brüning T,Assmann G

    更新日期:1987-12-01 00:00:00

  • Chromogenic ionophore-based methods for spectrophotometric assay of sodium and potassium in serum and plasma.

    abstract::We report spectrophotometric methods for quantifying sodium and potassium in serum and plasma without sample pretreatment or solvent-extraction steps. The methods are based on novel chromogenic ionophores characterized by molecular structures highly preorganized for binding, which result in exceptionally high sensitiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kumar A,Chapoteau E,Czech BP,Gebauer CR,Chimenti MZ,Raimondo O

    更新日期:1988-09-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00

  • Regulation of serum paraoxonase activity by genetic, nutritional, and lifestyle factors in the general population.

    abstract:BACKGROUND:Paraoxonase may protect lipoproteins and cell membranes from peroxidation, and alterations in the activity of this enzyme have been associated with some chronic diseases. Serum paraoxonase appears to be mainly under genetic control, but some studies suggest that environmental factors may also modulate its ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.9.1491

    authors: Ferré N,Camps J,Fernández-Ballart J,Arija V,Murphy MM,Ceruelo S,Biarnés E,Vilella E,Tous M,Joven J

    更新日期:2003-09-01 00:00:00

  • Rapid, simple, and sensitive immunoagglutination assay with SiO2 particles and quartz crystal microbalance for quantifying Schistosoma japonicum antibodies.

    abstract:BACKGROUND:The resurgence of the parasitic disease schistosomiasis calls for more efficient diagnostic tests. We developed a rapid, simple, portable, and sensitive immunoagglutination assay that uses SiO(2) particles and quartz crystal microbalance (QCM) for quantifying Schistosoma japonicum (Sj) antibodies (SjAb). ME...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.071555

    authors: Wang H,Zhang Y,Yan B,Liu L,Wang S,Shen G,Yu R

    更新日期:2006-11-01 00:00:00

  • Substantial urinary concentrations of material resembling beta-core fragment of chorionic gonadotropin beta-subunit in mid-menstrual cycle.

    abstract::We measured the day-to-day variations in concentrations of beta-core, luteinizing hormone (LH), and alpha-subunit in urine during the menstrual cycle. The alpha-subunit concentrations showed a pattern similar to that of the LH concentrations. beta-Core-like material was increased during and up to 3 to 4 days after the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neven P,Iles RK,Howes I,Sharma K,Shepherd JH,Edwards R,Collins WP,Chard T

    更新日期:1993-09-01 00:00:00

  • Incubation with neuraminidase and affinity electrophoresis with wheat-germ lectin compared for separating and quantifying alkaline phosphatase isoenzymes in plasma.

    abstract::Of 98 patients' specimens examined for alkaline phosphatase (EC 3.1.3.1) isoenzymes by electrophoresis on cellulose acetate membrane after incubation with neuraminidase, 50 showed only a single liver or bone isoenzyme staining band; in 15 of these, the tissue origin of the fraction could not be accurately identified f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY

    更新日期:1985-07-01 00:00:00

  • The fiscal consequences of central vs distributed testing of glucose.

    abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkelman JW,Wybenga DR,Tanasijevic MJ

    更新日期:1994-08-01 00:00:00

  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Glucocorticoid receptors in normal leukocytes: effects of age, gender, season, and plasma cortisol concentrations.

    abstract::We measured glucocorticoid receptors (GR) in mononuclear leukocytes (MNL) isolated from peripheral blood of 145 apparently healthy volunteers (86 men and 59 women). An age-related decrease in the number of GR was suggested between subjects younger than 20 years and elderly subjects; there was no apparent seasonal vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka H,Akama H,Ichikawa Y,Homma M,Oshima H

    更新日期:1991-10-01 00:00:00

  • Cortisol production rate determined by radio gas-chromatography.

    abstract::We describe a ratio gas-chromatographic method for determination of cortisol production rate by measuring the isotope dilution of urinary cortisol metabolites. The method was calibrated by analyzing [3H]tetrahydrocortisol and [3H]tetrahydrocortisone of known specific activities. Results are reasonably well reproducibl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Derks HJ,Muskiet FA,Wolthers BG,Thijssen JH,Drayer NM

    更新日期:1977-03-01 00:00:00

  • Global sequencing approach for characterizing the molecular background of hereditary iron disorders.

    abstract:BACKGROUND:New genetic forms of hereditary hemochromatosis (HH) or hereditary hyperferritinemia (HF) have been identified over the last few years, and abnormalities of various genes may interact in a single patient. This study aimed to develop a rapid automated method for sequencing the main genes involved. METHODS:We...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090605

    authors: Cunat S,Giansily-Blaizot M,Bismuth M,Blanc F,Dereure O,Larrey D,Quellec AL,Pouderoux P,Rose C,Raingeard I,Renard E,Schved JF,Aguilar-Martinez P,CHU Montpellier AOI 2004 Working Group.

    更新日期:2007-12-01 00:00:00

  • Real-time quantitative PCR for the measurement of MYCN amplification in human neuroblastoma with the TaqMan detection system.

    abstract:BACKGROUND:Neuroblastoma is the most common extracranial malignant solid tumor in children under 5 years and is characterized by a wide clinical and biological heterogeneity, from spontaneously regressive forms to cancers with a rapid and fatal progression. MYCN oncogene amplification is considered the most important p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raggi CC,Bagnoni ML,Tonini GP,Maggi M,Vona G,Pinzani P,Mazzocco K,De Bernardi B,Pazzagli M,Orlando C

    更新日期:1999-11-01 00:00:00

  • Performance of an enzyme-linked immunosorbent assay system for antibodies to hepatitis C virus with two new antigens (c11/c7).

    abstract::We developed an enzyme-linked immunosorbent assay (ELISA) system for antibodies to the hepatitis C virus (HCV), using two new recombinant antigens (c11 and c7) derived from the HCV genome. The performance of this ELISA system (Imucheck HCV Ab) was examined. The CV values for both intra-assay precision and reproducibil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Saito M,Hasegawa A,Kashiwakuma T,Kohara M,Sugi M,Miki K,Yamamoto T,Mori H,Ohta Y,Tanaka E

    更新日期:1992-12-01 00:00:00

  • Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    abstract::Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shepherd J,Packard CJ,Dryburgh FJ,Third JL

    更新日期:1975-12-01 00:00:00

  • Absolute and relative kinetic changes of high-sensitivity cardiac troponin T in acute coronary syndrome and in patients with increased troponin in the absence of acute coronary syndrome.

    abstract:BACKGROUND:We evaluated kinetic changes of high-sensitivity cardiac troponin T (hs-cTnT) in patients with acute coronary syndrome (ACS) and patients with hs-cTnT increases not due to ACS to rule in or rule out non-ST-segment elevation myocardial infarction (STEMI). METHODS:hs-cTnT was measured serially in consecutive ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.171827

    authors: Mueller M,Biener M,Vafaie M,Doerr S,Keller T,Blankenberg S,Katus HA,Giannitsis E

    更新日期:2012-01-01 00:00:00

  • Flow-injection analysis for malondialdehyde in plasma with the thiobarbituric acid reaction.

    abstract::A simple, precise, and rapid method to measure plasma malondialdehyde (MDA) was developed by use of solvent extraction--flow-injection analysis. The reagent solution, containing thiobarbituric acid (TBA), 5 g/L in 100 mL/L phosphoric acid, and extraction solvent (methylisobutyl ketone, MIBK) were propelled with a doub...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ikatsu H,Nakajima T,Murayama N,Korenaga T

    更新日期:1992-10-01 00:00:00

  • Radioimmunoassay of thyroxine in 10 microliters of serum, with use of aggregated antithyroxine antibodies.

    abstract::We describe a sensitive radioimmunoassay for rapidly determining the concentration of thyroxine in 10 microL of human serum. Aggregated antithyroxine antibodies are used to separate bound and free hormone. This speeds the assay and economizes on reagents without loss of sensitivity, specificity, or precision. Results ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Collins S,Brooks M,Bermes EW

    更新日期:1980-03-01 00:00:00

  • Expression of prostate-specific antigen and prostate-specific membrane antigen transcripts in blood cells: implications for the detection of hematogenous prostate cells and standardization.

    abstract::Circulating prostate cells can be detected in cancer patients by using reverse transcriptase-PCR (RT-PCR) assay for prostate-specific antigen (PSA) and prostate-specific membrane antigen (PSM) mRNA. A quality-control study involving a conventional RT-PCR assay was performed and, surprisingly, detected both transcripts...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gala JL,Heusterspreute M,Loric S,Hanon F,Tombal B,Van Cangh P,De Nayer P,Philippe M

    更新日期:1998-03-01 00:00:00

  • Metabolic relationship between urea and guanidino compounds as studied by automated fluorimetry of guanidino compounds in urine.

    abstract::In this automated system for assaying guanidino compounds, the compounds are resolved on an ion-exchange (Dowex 50) column, then reacted with phenanthrenequinone in alkaline solution. This mixture is then acidified and the resulting fluorescence is measured (lambda ex, 305 nm; lambda em, 395 nm). I applied the system ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Natelson S

    更新日期:1984-02-01 00:00:00

  • Gas-chromatographic determination of cholesterol sulfate in plasma and erythrocytes, for the diagnosis of recessive X-linked ichthyosis.

    abstract::We describe a rapid method for determining cholesterol sulfate in plasma and erythrocytes. After its single-step isolation by means of anion-exchange chromatography cholesterol sulfate is hydrolyzed, trimethylsilylated, and determined by gas chromatography with flame ionization detection. 5 beta-Cholestan-3 alpha-ol s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Jansen G,Wolthers BG,Marinkovic-Ilsen A,van Voorst Vader PC

    更新日期:1983-07-01 00:00:00

  • Evaluating Rapid Rule-out of Acute Myocardial Infarction Using a High-Sensitivity Cardiac Troponin I Assay at Presentation.

    abstract:BACKGROUND:Low concentrations of cardiac troponin (cTn) have been recommended for rapid rule-out of acute myocardial infarction (AMI). We examined the Beckman Coulter Access high-sensitivity cardiac troponin I (hs-cTnI) assay to identify a single test threshold that can safely rule out AMI. METHODS:This analysis used ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.283887

    authors: Greenslade J,Cho E,Van Hise C,Hawkins T,Parsonage W,Ungerer J,Tate J,Pretorius C,Than M,Cullen L

    更新日期:2018-05-01 00:00:00

  • High-throughput mitochondrial genome screening method for nonmelanoma skin cancer using multiplexed temperature gradient capillary electrophoresis.

    abstract:BACKGROUND:We explored the utility of multiplexed temperature gradient capillary electrophoresis (TGCE) as a screening tool for identifying genetic changes in the human mitochondrial genome. We examined changes in mitochondrial DNA (mtDNA) in nonmelanoma skin cancers (NMSCs), using TGCE to resolve genetic differences c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.040311

    authors: Girald-Rosa W,Vleugels RA,Musiek AC,Sligh JE

    更新日期:2005-02-01 00:00:00

  • Sample preparation with ion-exchange resin before liquid-chromatographic determination of plasma catecholamines.

    abstract::Estimation of plasma catecholamine concentrations by "high-performance" liquid chromatography, although increasingly used, still presents difficulties. We describe a method for clean-up of plasma samples on cation-exchange resin before they are extracted with alumina. This procedure eliminates many of the interfering ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frayn KN,Maycock PF

    更新日期:1983-07-01 00:00:00

  • Comparison of a logistic and a mass-action curve for radioimmunoassay data.

    abstract::This paper compares a logistic curve and a mass-action curve in their ability to represent radioimmunoassay standard curves. A data base from 10 different assays is used in this comparison. Six of the 10 assays could be modeled equally well by either the logistic or the mass-action curve. In one case the mass-action c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raab GM

    更新日期:1983-10-01 00:00:00

  • Clinical applications of protein determinations in biological fluids other than blood.

    abstract::Over the past decade, significant improvements in immunochemical and electrophoretic techniques have enabled collection of heretofore unavailable data on proteins in biological fluids, greatly increasing our understanding of protein physiology in the various body compartments and providing the foundation for clinical ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Killingsworth LM

    更新日期:1982-05-01 00:00:00

  • State-of-the-art of serum testosterone measurement by isotope dilution-liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:The recent interest of clinical laboratories in developing serum testosterone assays based on isotope dilution-liquid chromatography-tandem mass spectrometry (ID-LC-MS/MS) stems from the lack of accuracy of direct immunoassays. In this study, we assessed the accuracy and state of standardization (traceabilit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.105841

    authors: Thienpont LM,Van Uytfanghe K,Blincko S,Ramsay CS,Xie H,Doss RC,Keevil BG,Owen LJ,Rockwood AL,Kushnir MM,Chun KY,Chandler DW,Field HP,Sluss PM

    更新日期:2008-08-01 00:00:00

  • Kinetic analyses of parathyroid hormone clearance as measured by three rapid immunoassays during parathyroidectomy.

    abstract:BACKGROUND:Rapid intraoperative parathyroid hormone (PTH) measurements are an important prerequisite for minimally invasive parathyroidectomy, serving as a feasible marker for "cure" because of the short half-life of PTH. Because automated analysis may facilitate monitoring, two automated PTH assays were compared with ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bieglmayer C,Prager G,Niederle B

    更新日期:2002-10-01 00:00:00

  • "Delfia" and "Amerlite": two sensitive nonisotopic immunoassay systems for assay of thyrotropin compared.

    abstract::We assessed the LKB "Delfia" (time-resolved dissociation-enhanced lanthanide fluoroimmunoassay) and the Amersham "Amerlite" (enhanced luminescent immunometry) assays of thyrotropin in serum. Both assays are sensitive (respective detection limits: 0.02 and 0.04 milli-int. unit/L) and have very good within- and between-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Parnham AJ,Tarbit IF

    更新日期:1987-08-01 00:00:00