Abstract:
:Of 98 patients' specimens examined for alkaline phosphatase (EC 3.1.3.1) isoenzymes by electrophoresis on cellulose acetate membrane after incubation with neuraminidase, 50 showed only a single liver or bone isoenzyme staining band; in 15 of these, the tissue origin of the fraction could not be accurately identified from its electrophoretic location. In the remaining 48 specimens, both liver and bone fractions were identifiable, but in only 25 of these was the electrophoretic resolution sufficient to yield separate peaks on densitometry. In contrast, both liver and bone alkaline phosphatase isoenzymes were identified in 95 of the 98 specimens by affinity electrophoresis involving wheat-germ lectin, the detection of both fractions being in agreement with the results of sequential heat inactivation. The tissue origin of the enzyme bands was readily ascertainable from their consistent electrophoretic location in this medium, and in 89 of the specimens the isoenzyme fractions could be resolved into separate peaks on densitometry. We conclude that resolution of liver and bone alkaline phosphatase by incubation with neuraminidase followed by cellulose acetate electrophoresis is greatly inferior to that obtained by wheat-germ lectin affinity electrophoresis.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Rosalki SB,Foo AYsubject
Has Abstractpub_date
1985-07-01 00:00:00pages
1198-200issue
7eissn
0009-9147issn
1530-8561journal_volume
31pub_type
杂志文章abstract:BACKGROUND:MALDI-TOF mass spectrometry (MS) is set to make inroads into clinical chemistry because it offers advantages over other analytical platforms. These advantages include low acquisition and operating costs, ease of use, ruggedness, and high throughput. When coupled with innovative front-end strategies and appli...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2015.239491
更新日期:2016-01-01 00:00:00
abstract::We compared the activities of thyroid-stimulating antibodies (TSAb) measured in cultures of human thyrocytes and the values for thyrotropin-receptor antibodies (TRAb) as measured with a commercial kit based on use of radiolabeled receptors. Sera were obtained from patients with Graves' disease before, during, and afte...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-07-01 00:00:00
abstract::We describe a rapid method for determining cholesterol sulfate in plasma and erythrocytes. After its single-step isolation by means of anion-exchange chromatography cholesterol sulfate is hydrolyzed, trimethylsilylated, and determined by gas chromatography with flame ionization detection. 5 beta-Cholestan-3 alpha-ol s...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-07-01 00:00:00
abstract::A region consisting of 19 clinical laboratories harmonized their calibration of seven common enzymes by using fresh patient-pool sera. One of the laboratories was chosen to act as Regional Reference Laboratory (RRL). This laboratory used internationally accepted (mostly IFCC) methods at 37 degrees C, with an intralabo...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:
更新日期:1998-03-01 00:00:00
abstract::Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immun...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-10-01 00:00:00
abstract::We examined the relationship in a large-living population between the concentration of triglycerides in plasma from fasting persons and the concentration of very-low-density lipoprotein cholesterol (VLDL-C) as determined after preparative ultracentrifugation. Data from individuals in the Framingham Heart Study who wer...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-12-01 00:00:00
abstract::Even though significant progress has been made in the development of electrodes for the in vivo detection of catecholamines, oxygen, and various cations, there has been little research on the feasibility of continuously monitoring drugs in whole blood by electrochemical sensing devices. Electroanalytical problems asso...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-09-01 00:00:00
abstract:BACKGROUND:The genotype of hepatitis C virus (HCV) is a predictor of antiviral therapeutic response. We describe an approach for HCV genotype determination by real-time PCR and melting curve analysis. METHODS:After automated nucleic acid extraction, we used reverse transcription-PCR in a block cycler to amplify nucleo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-12-01 00:00:00
abstract::We have designed a re-usable dialysis cell and a complex dialysis buffer, with which undiluted serum samples can be dialyzed with minimal changes in their serum matrix. Dialysate thyroxin (free T4) is then measured by a sensitive RIA for T4. The range of reportability was 2-128 ng/L, the normal range was 8-27 ng/L, an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-09-01 00:00:00
abstract::The isoenzymes of lactate dehydrogenase (EC 1.1.1.27) were separated with excellent resolution in less than 1 h by high-pressure anion-exchange chromatography. These isoenzymes were determined in some tissue extracts and high-activity serum samples by this technique. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-04-01 00:00:00
abstract:BACKGROUND:There is need for a reference method for transferrin glycoforms in serum to which routine immunologic methods for the alcohol marker carbohydrate-deficient transferrin (CDT) can be traceable. We describe an improved HPLC method for transferrin glycoforms. METHODS:Transferrin was iron-saturated by mixing the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.023341
更新日期:2003-11-01 00:00:00
abstract::We developed and evaluated a direct ultraviolet method for the enzymatic determination of uric acid in serum, plasma, or urine, without deproteinization of sera and plasma. Equilibrium and nonlinear curve-fitting kinetic options are evaluated and compared, and results of the proposed method are compared with those of ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-03-01 00:00:00
abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2006.083493
更新日期:2007-06-01 00:00:00
abstract:BACKGROUND:The association of changes in oxidative and proinflammatory states with vascular function after diet and exercise intervention among obese children has not been previously explored. METHODS:In this 6-week diet and exercise intervention study in 35 obese children, age 12 to 18 years, we evaluated the relatio...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2007.089953
更新日期:2008-01-01 00:00:00
abstract::Liquid scintillation counting of 3H-labeled whole-blood samples is severely impaired owing to quenching by blood pigments. In this study, dry oxidation and chemical solubilization followed by decolorization were the two general methods used to eliminate color quenching. Three blood volumes were examined: 0.25, 0.50, a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-04-01 00:00:00
abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-06-01 00:00:00
abstract:BACKGROUND:Until recently, clinical laboratories have monitored hemophilia treatment by measuring coagulation factors before/after infusion of human-derived or recombinant factors. Substantial changes are expected in the near future based on new therapeutic approaches that have been or are being developed. CONTENT:Hem...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2017.284356
更新日期:2019-02-01 00:00:00
abstract:BACKGROUND:Two mutations in HFE, G845A (amino acid substitution C282Y) and C187G (H63D), are associated with hereditary hemochromatosis. We developed and validated a novel method, linked linear amplification (LLA), for detection of these two mutations. METHODS:Two segments of HFE were amplified by a multiplex LLA reac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.7.1050
更新日期:2003-07-01 00:00:00
abstract:BACKGROUND:The aim of our present study was to establish new reference intervals for thyrotropin (TSH) and thyroid hormones based on National Academy of Clinical Biochemistry (NACB) criteria and regular thyroid ultrasonography. We also assessed the effect of potentially confounding factors to modulate the limits of the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.047399
更新日期:2005-08-01 00:00:00
abstract::The method is based on the selective activating capacity of dithiothreitol on creatine kinase isoenzyme MB, after isoenzyme MM is activated by glutathione. Isolated isoenzymes MM and MB of human and canine origin were assayed individually and in mixtures of known activities. When glutathione was present in the assay m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-10-01 00:00:00
abstract::Noninvasive monitoring of blood/tissue glucose concentrations has been successfully accomplished in individual diabetic subjects by using near-infrared (NIR) spectroscopy coupled with chemometric methods. Three different spectrometer configurations were tested: a) a Fourier-transform infrared spectrometer with an indi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-09-01 00:00:00
abstract:INTRODUCTION:Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. METHODS:67 speci...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1093/clinchem/hvaa211
更新日期:2020-09-07 00:00:00
abstract::This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantifi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-12-01 00:00:00
abstract::Extensive data implicate cholesterol in the atherosclerotic process responsible for coronary disease. Of the atherosclerotic disease outcomes, serum cholesterol is most strongly related to coronary disease. A significant relationship of serum cholesterol to all clinical manifestations of coronary heart disease has bee...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1988-01-01 00:00:00
abstract::Measurement of serum ascorbate may be useful in long-term population studies because of the possible influence of ascorbate on numerous physiological factors. We describe an automated method for determining ascorbate in serum and urine by using the reduction of ferric iron by ascorbate and the formation of a color bet...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-09-01 00:00:00
abstract::A sensitive, specific, and simple method for determining serum or urine arylesterase (EC 3.1.1.2) is described. The enzyme acts on phenyl acetate to release phenol, which produces a stable indophenol dye with 4-aminoantipyrine and potassium ferricyanide. Arylesterase, a thiol enzyme, is reactivated by 2-mercaptoethano...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-10-01 00:00:00
abstract::Ingestion of oleander plant, containing the cardiac glycoside oleandrin, has been reported to induce fatal poisonings. Derivatives of oleandrin are structurally similar to digoxin. We investigated the cross-reactivities of oleandrin and its aglycone metabolite, oleandrigenin, in several commercially available digoxin ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-10-01 00:00:00
abstract:BACKGROUND:Noninvasive prenatal testing (NIPT) uses cell-free DNA (cfDNA) as an analyte to detect copy-number alterations in the fetal genome. Because maternal and fetal cfDNA contributions are comingled, changes in the maternal genome can manifest as abnormal NIPT results. Circulating tumor DNA (ctDNA) present in case...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.277517
更新日期:2018-02-01 00:00:00
abstract::We immunoenzymometrically measured creatine kinase (CK) isoenzyme MB in extracts of myocardium and in homogenates of five different skeletal muscles. CK-MB concentrations in the former averaged 80.9 micrograms/g wet tissue; in the skeletal muscles it varied widely, being (e.g.) 25-fold greater in diaphragm than in pso...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-02-01 00:00:00
abstract::We examined the comparative behavior of subject-specific multivariate and univariate reference regions, using both computer-generated data and serial (semi-annual) measurements of selected analytes in subjects from a large health-maintenance program. Univariate studies under both homeostatic and random-walk time-serie...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-03-01 00:00:00