Abstract:
:We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 micrograms/L; good analytical recovery (100.3%); and linearity with whole-blood specimens. The percentage cross-reactivity of the major CsA metabolites varied from 15.3% for AM9 (M-1), 8.2% for AM1 (M-17), and 3.7% for AM4N (M-21), to less than 3% for the other metabolites tested. Results with the TDx assay (y) correlated well with those by the Sandimmune selective RIA (x; Sandoz) with blood specimens from 44 renal-transplant recipients (n = 44, x= 187.3, y = 198.9, y = 5.49 + 1.03x, r = 0.987). The TDx values were on average 24% higher than those by HPLC (x') with the same patients' specimens (n = 44, x' = 159.9, y = 198.9, y = 15.9 + 1.14x', r = 0.967). We conclude that the Abbott TDx monoclonal antibody assay provides a rapid, precise, and accurate means for quantifying CsA in whole blood.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Yatscoff RW,Copeland KR,Faraci CJsubject
Has Abstractpub_date
1990-11-01 00:00:00pages
1969-73issue
11eissn
0009-9147issn
1530-8561journal_volume
36pub_type
杂志文章abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-03-01 00:00:00
abstract::We describe a new and specific method for measurement of lecithin palmitic acid in amniotic fluid. Dipalmitoyl lecithin, the major alveolar surfactant, has previously been estimated by measuring the lecithin-sphingomyelin ratio, total lecithin, total phospholipid phosphorus, and (or) total palmitic acid. Our method is...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract::In a previous comparison study of "dry chemistry" desktop analyzers, the ChemPro 1000 (Arden Medical Systems) was one of several instruments found suitable for field use. We have now evaluated the linearity, accuracy, and precision of the ChemPro 1000, according to NCCLS Document EP 10-P. We also compared results with...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-11-01 00:00:00
abstract:BACKGROUND:C-reactive protein (CRP) is a widely recognized indicator of inflammation and is known to play an important role in atherogenesis. Recent prospective studies have demonstrated that increased CRP concentrations within the reference interval are a strong predictor of myocardial infarction, stroke, sudden cardi...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/49.8.1258
更新日期:2003-08-01 00:00:00
abstract::The purpose of Medicare's Demonstration of Competitive Bidding for Clinical Laboratory Services is to determine whether competitive bidding can be used to provide quality laboratory services at prices below current Medicare reimbursement rates. Here, we present key features of the preliminary design for the demonstrat...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-08-01 00:00:00
abstract::We examined the variability of lipid and lipoprotein concentrations in plasma from a population sample from the Jerusalem Lipid Research Clinic study. Coefficients of variation of about 8% for plasma cholesterol, 11% to 15% for low- and high-density-lipoprotein cholesterol, and about 30% for triglyceride were reported...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-07-01 00:00:00
abstract::We describe specific EMIT homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine in patients' serum samples. Before analysis, an easily performed extraction step involving the use of 500 microL of sample and a 1-mL disposable column eliminates cross-reacting polar metabolites. Th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-05-01 00:00:00
abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract::A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1990-04-01 00:00:00
abstract::Peroxidation of lipids is believed to play a key role in various degenerative diseases. However, few simple tests are able to detect individual susceptibility or resistance to peroxidation. Measurement of the basal concentrations of lipid peroxides in plasma is not satisfactory because they are so low. Therefore, we d...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-10-01 00:00:00
abstract::Toxicological determinations are crucial to coroners' or medical examiners' judgments that drugs are significantly involved in a death. However, differences in laboratory procedures, thoroughness of screening, and limits of detection may result in artifactual differences in the toxicological results and the subsequent...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-06-01 00:00:00
abstract::"TDx Fetal Lung Maturity," an automated assay that measures the relative concentrations of surfactant and albumin in amniotic fluid, was compared with the lecithin/sphingomyelin (L/S) ratio and phosphatidylglycerol determination at five clinical sites. A total of 695 amniotic fluid samples were analyzed, of which 312 ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-06-01 00:00:00
abstract:BACKGROUND:An abnormal IgLkappa:IgLlambda ratio has long been used as a clinical criterion for non-Hodgkin B-cell lymphomas. As a first step toward a quantitative real-time PCR-based multimarker diagnostic analysis of lymphomas, we have developed a method for determination of IgLkappa:IgLlambda ratio in clinical sample...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.1.51
更新日期:2003-01-01 00:00:00
abstract:BACKGROUND:Detection of melanoma cells in circulation may be important in assessing tumor progression. The objective of this study was to develop a specific, reliable multimarker quantitative real-time reverse transcription-PCR (qRT) assay for detecting melanoma cells in patients' blood. METHODS:We developed qRT assay...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.045096
更新日期:2005-06-01 00:00:00
abstract:BACKGROUND:Simple, reproducible assays are needed for the quantification of sphingolipids, ceramide (Cer), and sphingoid bases. We developed an HPLC method for simultaneous quantification of total plasma concentrations of Cer, glucosylceramide (GlcCer), and ceramide trihexoside (CTH). METHODS:After addition of sphinga...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.079012
更新日期:2007-04-01 00:00:00
abstract::In this automated apoenzyme reactivation immunoassay system (Ames Optimate) for thyroxin-binding globulin (TBG), the sample and N6-aminohexylflavin adenine dinucleotide-labeled TBG react sequentially with antiserum. Then apoglucose oxidase is added to combine with the free fraction and generate glucose oxidase activit...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-05-01 00:00:00
abstract::In this simple and low-cost radioimmunoassay (RIA) procedure for thyroxin (T4), ethacridine (6,9-diamino-2-ethoxyacridine lactate; Rivanol) is used to separate antibody-bound ligand and free ligand. This acridine dye precipitates free T4 not bound to antibody. At pH 8.6, it precipitates more than 90% of 125I-labeled T...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-11-01 00:00:00
abstract:BACKGROUND:For the past 30 years, the Sanger method has been the dominant approach and gold standard for DNA sequencing. The commercial launch of the first massively parallel pyrosequencing platform in 2005 ushered in the new era of high-throughput genomic analysis now referred to as next-generation sequencing (NGS). ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2008.112789
更新日期:2009-04-01 00:00:00
abstract::In the diagnosis of chronic (as opposed to acute) liver diseases, combinations of indicators are needed to improve specificity. Alanine aminopeptidase (AAP; microsomal aminopeptidase, EC 3.4.11.2) activity in serum reportedly is a very sensitive indicator of intrahepatic cholestasis and biliary obstruction; it is also...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-03-01 00:00:00
abstract::We evaluated the technical performance of the Ciba Corning ACS:180 automated immunoassay system for the following analytes: thyroid-stimulating hormone, free thyroxine, luteinizing hormone, follicle-stimulating hormone, prolactin, human chorionic gonadotropin, carcino-embryonic antigen, and prostate-specific antigen. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-03-01 00:00:00
abstract:BACKGROUND:Identifying markers of chronic kidney disease (CKD) that occur early in the disease process and are specific to loss of kidney function rather than other underlying causes of disease may allow earlier, more accurate identification of patients who will develop CKD. We therefore sought to identify diagnostic b...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.291104
更新日期:2019-03-01 00:00:00
abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1093/clinchem/hvaa287
更新日期:2021-01-08 00:00:00
abstract::We describe conditions for determining carboxypeptidase N (EC 3.4.17.3) activity by liquid chromatography. Serum (10 microL) is mixed with the artificial substrates hippuryl-L-arginine (30 mmol/L) and hippuryl-L-lysine (100 mmol/L) in 50 mmol/L 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES) buffer solution...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-12-01 00:00:00
abstract::We evaluated a dual-precipitation method for determining cholesterol in high-density lipoprotein (HDL) and its subfractions HDL2 and HDL3. After total HDL was isolated by precipitation of very-low-density (VLDL) and low-density (LDL) lipoproteins with polyethylene glycol (Mr 8000), HDL2 was isolated from total HDL by ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-11-01 00:00:00
abstract::We describe a chromatographic system involving a high-performance chemically-bonded reverse-phase column and fluorescence detection for measurement of indoles in urine. We controlled retention and selectivity by optimizing the methanol content and pH of the mobile phase. Six reference indoles were separated in less th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-02-01 00:00:00
abstract:BACKGROUND:Functional antibody surfaces were prepared on ultraflat polystyrene surfaces by physical adsorption, and the uniform distribution of monoclonal antibodies against hepatitis B surface antigen (anti-HBs) on such surfaces and the presence of dense hepatitis B surface antigen (HBsAg) particles captured by immobi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::We compared the effects of freezing serum on the determination of high-density lipoprotein (HDL) subfractions by two dual-precipitation methods, heparin and manganese chloride/dextran sulfate (HM/DS) (Gidez et al., J Lipid Res 1982;23:1206-23) and DS/DS (Warnick et al., Clin Chem 1982;28:1574), and by ultracentrifugat...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-09-01 00:00:00
abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-02-01 00:00:00
abstract:BACKGROUND:Newborn screening for deficiency in the lysosomal enzymes that cause Fabry, Gaucher, Krabbe, Niemann-Pick A/B, and Pompe diseases is warranted because treatment for these syndromes is now available or anticipated in the near feature. We describe a multiplex screening method for all five lysosomal enzymes tha...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.035907
更新日期:2004-10-01 00:00:00
abstract:BACKGROUND:Plasma concentrations of small dense (sd)-LDL are associated with the prevalence of cardiovascular events. However, the special equipment and long assay times required for sd-LDL measurement have hindered its clinical application. Herein, we report development of a simple homogeneous assay for sd-LDL-cholest...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.149559
更新日期:2011-01-01 00:00:00