Evaluation of Ciba Corning ACS:180 automated immunoassay system.

Abstract:

:We evaluated the technical performance of the Ciba Corning ACS:180 automated immunoassay system for the following analytes: thyroid-stimulating hormone, free thyroxine, luteinizing hormone, follicle-stimulating hormone, prolactin, human chorionic gonadotropin, carcino-embryonic antigen, and prostate-specific antigen. The characteristics evaluated were: precision, carryover, linearity, lower limit of detection, analytical interferences, and comparison with other methods. Satisfactory results were obtained in the within-run and between-run precision studies. Neither sample nor reagent carryover was found for any assay. The range of linearity was acceptable. For some of the assays evaluated, the lower limit of detection was better than that claimed by the manufacturer. Correlation between ACS:180 methods and compared methods was adequate. We conclude that the ACS:180 offers good reliability, practicability, and performance capabilities.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Mora-Brugués J,Gascón-Roche N,Rodríguez-Espinosa J,Cortés-Rius M,González-Sastre F

subject

Has Abstract

pub_date

1994-03-01 00:00:00

pages

407-10

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

40

pub_type

杂志文章
  • Electrophoretic amylase fractionation as an aid in diagnosis of pancreatic disease.

    abstract::Six alpha-amylase (EC 3.2.1.1) isoenzymes have been resolved electrophoretically on cellulose acetate membranes in a discontinuous buffer system. The fastest migrating isoenzymes are of salivary origin (S1, S2, S3), the slower ones of pancreatic origin (P1, P2, P3). We determined the amylase isoenzyme distribution in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Legaz ME,Kenny MA

    更新日期:1976-01-01 00:00:00

  • Hyperglycosylated human chorionic gonadotropin in serum of testicular cancer patients.

    abstract:BACKGROUND:Hyperglycosylated human chorionic gonadotropin (hCG-h) contains larger and more complex carbohydrate chains than regular human chorionic gonadotropin (hCG). hCG-h is thought to be the major form of hCG produced by testicular cancers and it has been suggested to play a key role in tumor invasion, but studies ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.183723

    authors: Lempiäinen A,Hotakainen K,Blomqvist C,Alfthan H,Stenman UH

    更新日期:2012-07-01 00:00:00

  • Optimized liquid-chromatographic method for fluorometric determination of urinary delta-aminolevulinic acid in workers exposed to lead.

    abstract::We developed a fluorometric method for determining delta-aminolevulinic acid (ALA) in urine of lead workers. A high-performance liquid chromatograph (HPLC) equipped with a fluorescence HPLC monitor is used. The detection limit for aqueous ALA is 20 micrograms/L (15 pmol of ALA in the 100-microL sample). The working li...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tomokuni K,Ichiba M,Hirai Y,Hasegawa T

    更新日期:1987-09-01 00:00:00

  • Myoglobin concentration, creatine kinase activity, and creatine kinase B subunit concentrations in serum during thyroid disease.

    abstract::Changes in values for myoglobin, total creatine kinase (EC 2.7.3.2), and creatine kinase B-subunit in the serum of patients with thyroid disease are compared with values for these during the 24-h after myocardial infarction. Concentrations of all three of these muscle-derived proteins were significantly higher than no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Docherty I,Harrop JS,Hine KR,Hopton MR,Matthews HL,Taylor CJ

    更新日期:1984-01-01 00:00:00

  • Meaning of serum free-thyroxin values in nonthyroidal illnesses: seven methods compared.

    abstract::Serum free thyroxin (FT4) was determined in 40 patients with various nonthyroidal illnesses. We studied seven methods: (1) a free thyroxin index calculated from total T4 and triiodothyronine resin uptake; (2) a free T4 index determined by enzyme inhibitor assays (Abbott's "Tetrazyme" and "Thyrozyme"); (3) a free T4 in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chan DW,Waud JM,Taylor E,Stem J,Drew H,Oropeza M,Sucupira MS

    更新日期:1983-12-01 00:00:00

  • Kromoscopic analysis: a possible alternative to spectroscopic analysis for noninvasive measurement of analytes in vivo.

    abstract::Light that penetrates scattering media shows nonlinearities that mask the broad and shallow perturbations made by trace analytes on the background illuminant spectrum. Narrow-band spectroscopic decomposition and deconvolution of such weak bands is a formidable analytical task that pushes the fundamentally linear spect...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sodickson LA,Block MJ

    更新日期:1994-09-01 00:00:00

  • Immunochemical detection of group I and group II phospholipases A2 in human serum.

    abstract::Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nevalainen TJ,Kortesuo PT,Rintala E,Märki F

    更新日期:1992-09-01 00:00:00

  • Metabolic response of humans to ingestion of nicotinic acid and nicotinamide.

    abstract::The identification of nicotinamide-N1-oxide as a metabolite in the urine of a schizophrenic patient prompted a study of the relative metabolism of nicotinic acid and nicotinamide in mental patients and healthy volunteers. Metabolites quantified included N1-methyl-2-pyridone-5-carboxamide, N1-methyl-4-pyridone-3-carbox...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mrochek JE,Jolley RL,Young DS,Turner WJ

    更新日期:1976-11-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Strong association of a single nucleotide substitution in the 3'-untranslated region of the apolipoprotein-CIII gene with common hypertriglyceridemia in Arabs.

    abstract::A potential genetic marker for hypertriglyceridemia and coronary disease, an apolipoprotein-CIII gene allele displaying a single nucleotide substitution, was found in 71% of Arabs with primary hypertriglyceridemia. Over 96% of the unrelated adults possessing this allele showed hypertriglyceridemia. The same allele was...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taş S

    更新日期:1989-02-01 00:00:00

  • Evaluation of the lysosome-associated membrane protein LAMP-2 as a marker for lysosomal storage disorders.

    abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hua CT,Hopwood JJ,Carlsson SR,Harris RJ,Meikle PJ

    更新日期:1998-10-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Liquid-chromatographic profiling of solutes in serum of uremic patients undergoing hemodialysis and chronic ambulatory peritoneal dialysis (CAPD); high concentrations of pseudouridine in CAPD patients.

    abstract::Using "high performance" liquid chromatography, we studied non-protein-bound fractions and total concentrations of 18 solutes accumulating in sera from a group of 12 patients who were undergoing chronic ambulatory peritoneal dialysis (CAPD) and in predialysis sera from a group of 15 hemodialysis (HD) patients. We moni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schoots AC,Gerlag PG,Mulder AW,Peeters JA,Cramers CA

    更新日期:1988-01-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00

  • A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

    abstract::A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Riad-Fahmy D,Read GF,Gaskell SJ,Dyas J,Hindawi R

    更新日期:1979-05-01 00:00:00

  • Light-chain ratios of immunoglobulins G, A, and M determined by enzyme immunoassay.

    abstract::We describe an enzyme-linked immunosorbent assay for determination of light-chain ratios for IgG, IgA, and IgM in serum. A commercial serum with known overall kappa and lambda concentrations was used as standard. To capture the respective immunoglobulins, we used antibodies to gamma, lambda and mu chains coated onto m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chui SH,Lam CW,Lai KN

    更新日期:1990-03-01 00:00:00

  • Noninvasive Detection of Cocaine and Heroin Use with Single Fingerprints: Determination of an Environmental Cutoff.

    abstract:BACKGROUND:Recent publications have explored the possibility of using fingerprints to confirm drug use, but none has yet dealt with environmental contamination from fingertips. Here we explored the possibility of establishing an environmental cutoff for drug testing from a single fingerprint. METHODS:Fingerprint sampl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.281469

    authors: Ismail M,Stevenson D,Costa C,Webb R,de Puit M,Bailey M

    更新日期:2018-06-01 00:00:00

  • Proteasome inhibition measurements: clinical application.

    abstract:BACKGROUND:PS-341, a selective inhibitor of the proteasome, currently is under evaluation as an anticancer agent in multiple phase I clinical trials. In animal-model studies, PS-341 was rapidly removed from the vascular compartment and distributed widely, quickly approaching the limits of detection. An accurate pharmac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lightcap ES,McCormack TA,Pien CS,Chau V,Adams J,Elliott PJ

    更新日期:2000-05-01 00:00:00

  • Pediatric and perinatal reference intervals for immunoglobulin light chains kappa and lambda.

    abstract::In routine analysis for immunoglobulin light chains in pediatric diagnostics, the age-related reference intervals for serum kappa (kappa) and lambda (lambda) light chains were evaluated in 1543 healthy subjects (newborns to age 16 years, including 168 premature infants). Light-chain analysis was performed by rate neph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herkner KR,Salzer H,Böck A,Mühl A,Tsaka T,Steger H,Pollak A,Schatten C,Popp W,Huber-Spitzy V

    更新日期:1992-04-01 00:00:00

  • Toward absolute methods in clinical chemistry: application of mass fragmentography to high-accuracy analyses.

    abstract::We review recently developed reference methods based on mass fragmentography (specific ion monitoring) with use of isotope-labeled internal standard, for determination of cholesterol, triglycerides, urea, glucose, cortisol, progesterone, and testosterone. With an optimal ratio between standard and material to be deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Björkhem I,Blomstrand R,Lantto O,Svensson L,Ohman G

    更新日期:1976-11-01 00:00:00

  • Screening radioimmunoassay for aldosterone in preheated plasma without extraction and chromatography.

    abstract::We directly estimated plasma aldosterone radioimmunologically with use of an antiserum raised against an aldosterone-3-oxime/bovine serum albumin conjugate, the estimation being on samples with and without heating (60 degrees C), and diluted and undiluted. Values so obtained were compared with those by radioimmunoassa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Connolly TM,Tibor L,Gless KH,Vecsei P

    更新日期:1980-01-01 00:00:00

  • Gas-chromatographic assay of free phenytoin in ultrafiltrates of plasma: test of a new filtration apparatus and specimen stability.

    abstract::I describe a gas-chromatographic procedure involving a nitrogen detector for "free" (or "unbound") phenytoin in the concentration range 0.2-4.0 mg/L in ultrafiltrates of plasma. The CV (n = 10) for the assay was 2.9% for a 0.49 mg/L concentration, 1.5% for 2.02 mg/L. The sensitivity was 0.05 mg/L. The ultrafiltration ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Joern WA

    更新日期:1981-03-01 00:00:00

  • A fully automated solid-phase radioimmunoassay for triiodothyronine.

    abstract::We report the first solid-phase radioimmunoassay for triiodothyronine with use of antibody-coated tubes, which is designed specifically for the fully automated radioimmunoassay instrument, Micromedic Systems' "Concept 4 Automatic Radioassay." Antisera to triiodothyropropionic acid/bovine serum albumin were raised in r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rugg NE,Hasler MJ,Bjornsen RE,Painter K

    更新日期:1977-05-01 00:00:00

  • The endocrinology of aging.

    abstract::Physiologic systems have substantial reserves in younger individuals. The process of aging and intercurrent pathologic processes gradually eliminate these reserves. Changes in endocrine systems, including menopause in women, androgen deficiency in men, loss of skeletal mass, decrease in growth hormone serum concentrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Perry HM 3rd

    更新日期:1999-08-01 00:00:00

  • The changing epidemiology of depression.

    abstract::At the clinical level, we have seen the emergence of a subspecialty of affective disorders within psychiatry. Mood clinics, depression units, and affective disorders centers are appearing in many academic and clinical settings, where clinical skill and knowledge can be concentrated and new research furthered. By using...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klerman GL,Weissman MM

    更新日期:1988-05-01 00:00:00

  • Estimation of very-low-density lipoprotein cholesterol from data on triglyceride concentration in plasma.

    abstract::We examined the relationship in a large-living population between the concentration of triglycerides in plasma from fasting persons and the concentration of very-low-density lipoprotein cholesterol (VLDL-C) as determined after preparative ultracentrifugation. Data from individuals in the Framingham Heart Study who wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson PW,Abbott RD,Garrison RJ,Castelli WP

    更新日期:1981-12-01 00:00:00

  • Mechanized amidolytic technique for determination of factor X and factor-X antigen, and its application to patients being treated with oral anticoagulants.

    abstract::We describe a mechanized chromogenic assay for factor X, the results of which correlate well with those for the one-stage clotting assays for factor X in which it is activated either via the extrinsic pathway by thromboplastin or directly by Russell's viper venom. We purified human factor X and raised monospecific ant...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: van Wijk EM,Kahlé LH,ten Cate JW

    更新日期:1980-06-01 00:00:00

  • Liquid chromatography-isotope dilution-mass spectrometry as a new basis for the reference measurement procedure for hemoglobin A1c determination.

    abstract:BACKGROUND:Standardization of hemoglobin (Hb)A(1c) measurements is a process of considerable interest for quality assurance in diabetes management. To contribute to continuous quality improvement and fulfillment of the requirements for reference measurement procedures according to the standards of the International Org...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.139477

    authors: Kaiser P,Akerboom T,Ohlendorf R,Reinauer H

    更新日期:2010-05-01 00:00:00

  • Intravascular monitoring: problems and promise.

    abstract::Intravascular monitoring of arterial blood gases provides the means to detect precipitous change in cardiopulmonary function almost instantaneously, promising major improvement in the ability to manage critically ill patients. Attempts to miniaturize and repackage conventional electrodes for continuous intravascular u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Halbert SA

    更新日期:1990-08-01 00:00:00

  • Monitoring the stability of wavelength calibration of spectrophotometers.

    abstract::The difference in absorbance (delta A) between equimolar acid and alkaline solutions of methyl red, at a wavelength near the isosbestic point of the indicator, is reproducible. Furthermore, this delta A is sensitive to changes in the wavelength calibration of the instrument used to make the measurement. The delta A of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Korzun WJ,Miller WG