Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

Abstract:

:We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially in values for VLDL- and HDL-cholesterol (mean difference: VLDL-cholesterol, -61 mg/L; HDL-cholesterol, + 108 mg/L). Lipoprotein electrophoretic data indicated that estimating VLDL-cholesterol from serum triglyceride concentrations invariably resulted in higher values for children with an extremely faint pre-beta-lipoprotein band. Among the HDL-subfractions, 14 to 20% of HDL2 was precipitated by heparin-Mn2+ despite the presence of 80 g of albumin per liter. Heparin affinity chromatography of HDL2 in the presence of Ca2+ and Mn2+ showed an interaction of apolipoprotein E-containing HDL2 subfraction only in conditions involving Mn2+. The heparin-Ca2+ procedure precipitated the equivalent of 2 g of beta- plus pre-beta-lipoprotein cholesterol per liter from serum, with no detectable apolipoprotein B in the supernate. We conclude that these precipitations are affected by cation specificity and by differences in lipoprotein makeup of a given individual or population group.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Srinivasan SR,Foster TA,Berenson GS

subject

Has Abstract

pub_date

1980-10-01 00:00:00

pages

1548-53

issue

11

eissn

0009-9147

issn

1530-8561

journal_volume

26

pub_type

杂志文章
  • Specific determination of beta-galactocerebrosidase activity via competitive inhibition of beta-galactosidase.

    abstract:BACKGROUND:The determination of cellular beta-galactocerebrosidase activity is an established procedure to diagnose Krabbe disease and monitor the efficacy of gene/stem cell-based therapeutic approaches aimed at restoring defective enzymatic activity in patients or disease models. Current biochemical assays for beta-ga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.115873

    authors: Martino S,Tiribuzi R,Tortori A,Conti D,Visigalli I,Lattanzi A,Biffi A,Gritti A,Orlacchio A

    更新日期:2009-03-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Flash-heater ethylation of some antiepileptic drugs.

    abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friel P,Troupin AS

    更新日期:1975-05-01 00:00:00

  • Lipoprotein(a)-cholesterol and coronary heart disease in the Framingham Heart Study.

    abstract:BACKGROUND:Increased plasma lipoprotein(a) [Lp(a)] concentrations have been reported to be an independent risk factor for coronary heart disease (CHD) in some prospective studies, but not in others. These inconsistencies may relate to a lack of standardization and the failure of some immunoassays to measure all apolipo...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Seman LJ,DeLuca C,Jenner JL,Cupples LA,McNamara JR,Wilson PW,Castelli WP,Ordovas JM,Schaefer EJ

    更新日期:1999-07-01 00:00:00

  • Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma.

    abstract::We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jaouhari J,Schiele F,Dragacci S,Tarallo P,Siest JP,Henny J,Siest G

    更新日期:1992-10-01 00:00:00

  • Development and evaluation of a glucose analyzer for a glucose controlled insulin infusion system ((Biostator).

    abstract::The Glucose-Controlled Insulin Infusion System (Biostator) is a modular, computerized, feedback control system for dynamic control of blood glucose concentrations in diabetics. This on-line glucose analyzer for use with whole blood utilizes a novel enzyme (glucose oxidase)-membrane configuration and an electrochemical...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fogt EJ,Dodd LM,Jenning EM,Clemens AH

    更新日期:1978-08-01 00:00:00

  • The clinical utility of high-sensitivity C-reactive protein in cardiovascular disease and the potential implication of JUPITER on current practice guidelines.

    abstract:BACKGROUND:High-sensitivity C-reactive protein (hsCRP) testing is relatively inexpensive and has been shown to predict the risk of cardiovascular disease (CVD) and diabetes in multiple patient groups, including those treated with statin therapy. JUPITER (Justification for the Use of Statins in Primary Prevention: An In...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.109728

    authors: Mora S,Musunuru K,Blumenthal RS

    更新日期:2009-02-01 00:00:00

  • 4-Chlorotestosterone acetate metabolites in cattle after intramuscular and oral administrations.

    abstract::The use of 4-chlorotestosterone acetate by farmers for cattle fattening was recently demonstrated although the use of this anabolic steroid is strictly forbidden in the European Union. We investigated the metabolism of 4-chlorotestosterone acetate in the bovine species after intramuscular and oral administration. Nine...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Le Bizec B,Montrade MP,Monteau F,Gaudin I,Andre F

    更新日期:1998-05-01 00:00:00

  • Single-Stranded DNA Library Preparation Preferentially Enriches Short Maternal DNA in Maternal Plasma.

    abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268656

    authors: Vong JSL,Tsang JCH,Jiang P,Lee WS,Leung TY,Chan KCA,Chiu RWK,Lo YMD

    更新日期:2017-05-01 00:00:00

  • Electrophoretic separation of high-density lipoprotein choelsterol evaluated and compared with the modified lipid research clinic procedure.

    abstract::We evaluated a new agarose-gel-electrophoretic procedure (Corning) (I) for separating and quantitating of high-density lipoprotein cholesterol (HDLC), comparing it with the modified Lipid Research Clinics (LRC) procedure (heparin 183 kilounits/L, MnCl2 92 mmol/L) (II). Method I was insensitive to an HDLC concentration...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stein EA,McNeely S,Steiner P

    更新日期:1979-11-01 00:00:00

  • A rapid, sensitive enzyme-linked immunoassay for human thyrotropin.

    abstract::In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tseng YC,Burman KD,Baker JR Jr,Wartofsky L

    更新日期:1985-07-01 00:00:00

  • Reflectance digital matrix photometry.

    abstract::We have designed and constructed a digital matrix photometer for quantitative measurement of reflected light of small chromophoric areas or colored spots. The areas are divided conceptually into small subunits in which the reflected light is measured. This is done through stepwise scanning with a photodiode array. The...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-06-01 00:00:00

  • Ligase chain reaction assay for human mutations: the Sickle Cell by LCR assay.

    abstract::We can detect the beta-globin gene sickle cell mutation by using an assay based on the ligase chain reaction. The simultaneous amplification of the human growth hormone gene in the same reaction serves as a control for the amount of template DNA or amplification efficiency. Ligation products, which are biotinylated at...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Reyes AA,Carrera P,Cardillo E,Ugozzoli L,Lowery JD,Lin CI,Go M,Ferrari M,Wallace RB

    更新日期:1997-01-01 00:00:00

  • The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

    abstract::We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. un...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilke TJ,Utley DJ

    更新日期:1988-07-01 00:00:00

  • Assay of delta-aminolaevulinate dehydratase in 10 microL of blood.

    abstract::A method is presented for the assay of delta-aminolaevulinate dehydratase (EC 4.2.1.24) to be performed on 10 microL of whole blood. Results compare favorably with those obtained with an accepted method (J. Clin. Chem. Clin. Bio-chem. 12: 389-390, 1974) that involves use of 200 microL of blood. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wigfield DC,Farant JP

    更新日期:1981-01-01 00:00:00

  • Standardization with synthetic 22-kDa monomer human growth hormone reduces discrepancies between two monoclonal immunoradiometric assay kits.

    abstract::Discrepancies among different methods for assaying human growth hormone have been described in various studies. The two major sources of discordant results are the heterogeneity of the antibodies and the different standardization bases used by the assay manufacturers. We propose standardizing assays with 22-kDa biosyn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Banfi G,Marinelli M,Pontillo M,Bonini P

    更新日期:1992-10-01 00:00:00

  • Immunoassay of low concentrations of albumin in urine by latex particle counting.

    abstract::We describe here a nonisotopic immunoassay, based on particle-counting technology, for the determination of urinary albumin. The assay takes only 35 min and has been fully automated on the IMPACT (Acade Diagnostic Systems, Brussels, Belgium) machine. The system measures albumin within a linear range between 6.25 and 5...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cambiaso CL,Collet-Cassart D,Lievens M

    更新日期:1988-02-01 00:00:00

  • Improved RNase protection assay for quantifying LDL-receptor mRNA; estimation of analytical imprecision and biological variance in peripheral blood mononuclear cells.

    abstract::We have improved the protocol for RNA quantification by using RNase protection. Instead of precipitation and extraction with phenol and chloroform, we use a faster and more reliable precipitation based on guanidinium thiocyanate (GdSCN). The internal standard is produced by in vitro transcription of a DNA template con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Petersen NE,Larsen LK,Nissen H,Jensen LG,Jensen A,Hyltoft Petersen P,Hørder,Gregersen N,Kristiansen K

    更新日期:1995-11-01 00:00:00

  • Development and evaluation of quality control dried blood spot materials in newborn screening for lysosomal storage disorders.

    abstract:BACKGROUND:Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111864

    authors: De Jesus VR,Zhang XK,Keutzer J,Bodamer OA,Mühl A,Orsini JJ,Caggana M,Vogt RF,Hannon WH

    更新日期:2009-01-01 00:00:00

  • Lp-PLA2: a new kid on the block.

    abstract:BACKGROUND:Atherosclerosis is a systemic disease with focal rupture of vulnerable plaque responsible for major clinical events. Several population-based studies indicate an association between lipoprotein-associated phospholipase A2 (Lp-PLA2) and cardiovascular events. Lp-PLA2 is emerging as a biomarker that may be a p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.070672

    authors: Zalewski A,Nelson JJ,Hegg L,Macphee C

    更新日期:2006-09-01 00:00:00

  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Rapid radiometric assay used to assess lactoferrin in granulocytes.

    abstract::We describe a rapid, precise, and sensitive radiometric assay for human lactoferrin. In this typical "sandwich"-type assay, anti-human lactoferrin is adsorbed onto a polystyrene sphere and bound lactoferrin is detected by the subsequent binding of 125I-labeled anti-human lactoferrin. The assay is accurate for lactofer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Freeman KL,Anderson DC,Hughes B,Buffone GJ

    更新日期:1985-03-01 00:00:00

  • Analytical performance of EMIT cyclosporine assay evaluated.

    abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Desai M

    更新日期:1991-12-01 00:00:00

  • Improved 63Ni radiochemical assay of free fatty acids in plasma.

    abstract::We have modified the 63Ni radiochemical method of Ho (Anal Biochem 1970;36:105) for determination of free fatty acids (FFA) in plasma. Extracting 1 or 0.1 mL of plasma with Dole's mixture (J Biol Chem 1960;235:2595) and washing the "heptane" layer with two volumes of isopropanol/water/dilute (0.5 mol/L) H2SO4 (25/25/1...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Barash H,Akov S

    更新日期:1987-01-01 00:00:00

  • Evaluation of nicked human chorionic gonadotropin content in clinical specimens by a specific immunometric assay.

    abstract::We report the development and characterization of an IRMA for the direct measurement of nicked human chorionic gonadotropin (hCGn) in blood and urine. hCGn derived from a reference preparation of hCG used as an immunogen elicits monoclonal antibodies (mAbs) with enhanced recognition of human luteinizing hormone epitop...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kovalevskaya G,Birken S,Kakuma T,Schlatterer J,O'Connor JF

    更新日期:1999-01-01 00:00:00

  • Simplified micro-scale procedure for preparing samples for theophylline determination by liquid chromatography.

    abstract::We describe an improved procedure for the preparation of plasma or serum for determination of theophylline by reverse phase high-performance liquid chromatography. Quantitative results are available in less than 30 min from receipt of sample. The chromatogram is complete in 8 to 16 min, which includes the use of an in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nelson JW,Cordry AL,Aron CG,Bartell RA

    更新日期:1977-01-01 00:00:00

  • Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.

    abstract::This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bowers GN Jr,Brassard C,Sena SF

    更新日期:1986-08-01 00:00:00

  • Molar absorptivities of beta-NADH and beta-NAD at 260 nm.

    abstract::To determine the molar absorptivities of beta-NADH and beta-NAD at 260 nm, we purified the reduced form of the coenzyme by repeated anion-exchange chromatography. A NADH preparation was so obtained for which the 260 nm/340 nm absorbance ratio was 2.265. When calculated with epsilon 340 beta-NADH = 6.22 times 10-3 for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Haid E,Lehmann P,Ziegenhorn J

    更新日期:1975-06-01 00:00:00

  • Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

    abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cohen A,Hertz HS,Mandel J,Paule RC,Schaffer R,Sniegoski LT,Sun T,Welch MJ,White E 5th

    更新日期:1980-06-01 00:00:00

  • Detection of microdeletion 22q11.2 in a fetus by next-generation sequencing of maternal plasma.

    abstract:BACKGROUND:Efforts have been undertaken recently to assess the fetal genome through analysis of circulating cell-free (ccf) fetal DNA obtained from maternal plasma. Sequencing analysis of such ccf DNA has been shown to enable accurate prenatal detection of fetal aneuploidies, including trisomies of chromosomes 21, 18, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.180794

    authors: Jensen TJ,Dzakula Z,Deciu C,van den Boom D,Ehrich M

    更新日期:2012-07-01 00:00:00