Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.

Abstract:

:This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests in 1985. The lower results on the NOVA 8 were adjusted upwards to match those of the ICA1 to give identical results. Both analyzers were evaluated under working conditions of high volumes and multiple operators to establish downtime, electrode life, and costs. We have classified all Ca2+ analyzers into first-, intermediate-, and second-generation instruments, the better to understand their differences. Results for large numbers of patients' sera were shown to be systematically different when any two analyzers were compared. These differences are the consequence of each manufacturer's unique choices of the following: (a) the matrix of the calcium calibration solutions, (b) the type and configuration of the reference electrode, and (c) the salt-bridge solution. Elimination of each analyzer's biases will require agreement on a reference system that defines the accuracy of Ca2+ measurements on serum, plasma, or whole blood. The sound analytical performance of today's second-generation Ca2+ analyzers has allowed us to exploit the inherent superiority of Ca2+ over total calcium (CaT) measurements in the daily care of patients. We report on the preference of Ca2+ over CaT by physicians at our hospital since the introduction of second-generation Ca2+ analyzers. Therefore, we state unequivocally from our very satisfactory experience over the past five years that Ca2+ is a clinical laboratory test whose time has come!

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bowers GN Jr,Brassard C,Sena SF

subject

Has Abstract

pub_date

1986-08-01 00:00:00

pages

1437-47

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

杂志文章,评审
  • Direct solid-phase fluoroenzymeimmunoassay of 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide in urine.

    abstract::A competitive solid-phase fluoroenzymeimmunoassay has been developed for rapidly measuring 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide (Pd-3G) directly in diluted specimens of pre-breakfast urine. The assay involves use of an antiserum to Pd-3G and enzyme-labeled antigen prepared by chemically linking g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shah H,Saranko AM,Härkönen M,Adlercreutz H

    更新日期:1984-02-01 00:00:00

  • Evaluation of the lysosome-associated membrane protein LAMP-2 as a marker for lysosomal storage disorders.

    abstract::For many lysosomal storage disorders, presymptomatic detection, before the onset of irreversible pathology, will greatly improve the efficacy of current and proposed therapies. In the absence of a family history, presymptomatic detection can be achieved only by a comprehensive newborn screening program. Recently we re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hua CT,Hopwood JJ,Carlsson SR,Harris RJ,Meikle PJ

    更新日期:1998-10-01 00:00:00

  • A multiplex assay for detecting genetic variations in CYP2C9, VKORC1, and GGCX involved in warfarin metabolism.

    abstract:BACKGROUND:Patients differ in responses to warfarin, which is commonly prescribed to treat thromboembolic events. Genetic variations in the cytochrome P450, family 2, subfamily C, polypeptide 9 (CYP2C9), vitamin K epoxide reductase complex, subunit 1 (VKORC1), and gamma-glutamyl carboxylase (GGCX) genes have been shown...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.118497

    authors: Rai AJ,Udar N,Saad R,Fleisher M

    更新日期:2009-04-01 00:00:00

  • A systematic approach to materials handling in clinical laboratories.

    abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nabb DP

    更新日期:1990-09-01 00:00:00

  • Evaluation of a fully automated serum assay for C-terminal cross-linking telopeptide of type I collagen in osteoporosis.

    abstract:BACKGROUND:Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-da...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garnero P,Borel O,Delmas PD

    更新日期:2001-04-01 00:00:00

  • A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

    abstract::A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Riad-Fahmy D,Read GF,Gaskell SJ,Dyas J,Hindawi R

    更新日期:1979-05-01 00:00:00

  • Development and validation of an immunoradiometric assay of parathyrin-related protein in unextracted plasma.

    abstract::This two-site immunoradiometric assay for human parathyrin-related protein 1-86 (PTHRP1-86) in plasma uses a mouse monoclonal antibody to PTHRP1-34 coupled to cellulose particles for immunoextraction of N-terminal immunoreactivity, and a rabbit antiserum to PTHRP37-67 that is indirectly labeled with 125I-labeled PTHRP...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ratcliffe WA,Norbury S,Heath DA,Ratcliffe JG

    更新日期:1991-05-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A

    更新日期:1997-09-01 00:00:00

  • Immunological assays of apolipoproteins in plasma: methods and instrumentation.

    abstract::A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Labeur C,Shepherd J,Rosseneu M

    更新日期:1990-04-01 00:00:00

  • Comparison and evaluation of cardiac biomarkers in patients with intermittent claudication: results from the CAVASIC study.

    abstract:BACKGROUND:Plasma concentrations of the peptides midregional proadrenomedullin (MR-proADM), midregional proatrial natriuretic peptide (MR-proANP), and C-terminal endothelin-1 precursor fragment (CT-proET-1) are increased in various cardiovascular conditions. However, there is limited information about the association a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.193656

    authors: Kollerits B,Sturm G,Lamina C,Hammerer-Lercher A,Rantner B,Stadler M,Ziera T,Struck J,Klein-Weigel P,Fraedrich G,Kronenberg F

    更新日期:2013-04-01 00:00:00

  • Relationships between immunogen structure and antisera specificity in the narcotic alkaloid series.

    abstract::We report the production and comparative specificities of antisera raised to different immunogens containing codeine, morphine, and oxycodone. Antisera raised to bovine serum albumin (BSA) conjugates of codeine-6-hemisuccinate, ethylmorphine-6-hemisuccinate, or oxycodone-6-carboxymethyloxime had greatest recognition o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Findlay JW,Butz RF,Jones EC

    更新日期:1981-09-01 00:00:00

  • Assessing the quality of glucose monitor studies: a critical evaluation of published reports.

    abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.083493

    authors: Mahoney J,Ellison J

    更新日期:2007-06-01 00:00:00

  • Multilayer film analysis for glucose in 1-microL samples of plasma.

    abstract::With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photome...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-12-01 00:00:00

  • Paraquat-induced renal injury studied by 1H nuclear magnetic resonance spectroscopy of urine.

    abstract::The herbicide paraquat (1,1'-dimethyl-4,4'-bipyridylium dichloride; PQ), is a poison known to cause delayed mortality due to lung and kidney injuries. High-resolution proton nuclear magnetic resonance (1H NMR) spectroscopy has been extensively applied in evaluating nephrotoxicity by the characteristic perturbations in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bairaktari E,Katopodis K,Siamopoulos KC,Tsolas O

    更新日期:1998-06-01 00:00:00

  • Determination of vanillylmandelic acid with ion-pair chromatography and fluorescence detection.

    abstract::We describe a chromatographic procedure for sensitive (2.0 mumol/L), specific quantification of vanillylmandelic acid (VMA) in urine with iso-VMA as an internal standard. After rapid extraction from urine, the VMA is determined by isocratic reversed-phase ion-pair chromatography on a bonded C8 column and detection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindgren K,Rodopoulos N

    更新日期:1986-04-01 00:00:00

  • Assay of prostate-specific antigen from whole blood spotted on filter paper and application to prostate cancer screening.

    abstract::We report the measure of prostate-specific antigen (PSA) from extracts of blood dried on filter paper. Five 3-mm (diameter) paper discs containing approximately 25 microL of dried whole blood were punched from the filter paper and extracted with 500 microL of buffer. Recovery of PSA was > 92%. Imprecision of the filte...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hoffman BR,Yu H,Diamandis EP

    更新日期:1996-04-01 00:00:00

  • Long-term aspirin and clopidogrel response evaluated by light transmission aggregometry, VerifyNow, and thrombelastography in patients undergoing percutaneous coronary intervention.

    abstract:BACKGROUND:A reduced response to aspirin and clopidogrel predicts ischemic events, but reliable tests are needed to identify low responders. We compared 3 platelet-function tests during long-term dual treatment with aspirin and clopidogrel. METHODS:Patients who underwent a percutaneous coronary intervention and were r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.137471

    authors: Madsen EH,Saw J,Kristensen SR,Schmidt EB,Pittendreigh C,Maurer-Spurej E

    更新日期:2010-05-01 00:00:00

  • Choriogonadotropin measured with the Tandem-E immunoenzymetric assay system.

    abstract::We evaluated the Hybritech Tandem-E procedure for quantifying choriogonadotropin (hCG) in human serum. In this "sandwich"-type assay, two monoclonal antibodies directed against different regions of the hCG molecule are used, one coated on a plastic bead, the second conjugated to alkaline phosphatase. The assay can det...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bock JL,Furgiuele J,Segen JC

    更新日期:1985-03-01 00:00:00

  • Personalized medicine in diabetes.

    abstract:BACKGROUND:Multiple genes that are associated with the risk of developing diabetes or the risk of diabetes complications have been identified by candidate gene analysis and genomewide scanning. These molecular markers, together with clinical data and findings from proteomics, metabolomics, pharmacogenetics, and other m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2010.156901

    authors: Malandrino N,Smith RJ

    更新日期:2011-02-01 00:00:00

  • Substrate-leash amplification with ribonuclease S-peptide and S-protein.

    abstract::The S-peptide and S-protein fragments of ribonuclease S (RNase S, no EC no. assigned) have been immobilized onto separate Sepharose gels via a "leash" of polycytidylic acid substrate. Each of these gels releases its RNase fragment when treated with the complementary enzyme fragment or with RNase A (EC 3.1.27.5), and t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ehrat M,Cecchini DJ,Giese RW

    更新日期:1986-09-01 00:00:00

  • gamma-Glutamyltransferase as a predictor of chronic kidney disease in nonhypertensive and nondiabetic Korean men.

    abstract:BACKGROUND:Little research has been done to examine whether gamma-glutamyltransferase (GGT) is prospectively associated with the development of chronic kidney disease (CKD). We performed a prospective study to examine the association between GGT and the risk for the development of CKD. METHODS:The study cohort include...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.078980

    authors: Ryu S,Chang Y,Kim DI,Kim WS,Suh BS

    更新日期:2007-01-01 00:00:00

  • Evidence that the amino-terminal composition of non-(1-84) parathyroid hormone fragments starts before position 19.

    abstract:BACKGROUND:Non-(1-84) parathyroid hormone (PTH) fragments are large C-terminal fragments of PTH with a partially preserved N-terminal structure. They differ from other C-terminal PTH fragments, which do not have an N-terminal structure and do not react in intact PTH assays. We aimed to identify the minimal N-terminal s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.040485

    authors: D'Amour P,Brossard JH,Räkel A,Rousseau L,Albert C,Cantor T

    更新日期:2005-01-01 00:00:00

  • Serum creatine kinase isoenzyme BB is a poor index to the size of various brain lesions.

    abstract::We divided patients with brain lesions into three groups: (a) patients with primary or metastatic brain cancer, (b) brain infarctions, and (c) brain contusion(s). We analyzed each patient's sera for creatine kinase isoenzyme BB (CK-BB), using a monoclonal antibody kit (Impres-BB; International Immunoassay Laboratories...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz JG,Bazan C 3rd,Gage CL,Prihoda TJ,Gillham SL

    更新日期:1989-04-01 00:00:00

  • Detection and characterization of blocking-type anti-acetylcholine receptor antibodies in sera from patients with myasthenia gravis.

    abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hara H,Hayashi K,Ohta K,Itoh N,Nishitani H,Ohta M

    更新日期:1993-10-01 00:00:00

  • A search for the best buffer to use in assaying human lactate dehydrogenase with the lactate-to-pyruvate reaction.

    abstract::Highly purified human lactate dehydrogenases I and V were assayed in 17 different buffers, at a variety of reaction pH's. Diethanolamine and 2-amino-2-methyl-1,3-propanediol provided the best measurements of the enzyme, assayed lactate-to-pyruvate. However, the commercial preparation of 2-amino-2-methyl-1,3-propanedio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buhl SN,Jackson KY,Lubinski R,Vanderlinde RE

    更新日期:1976-11-01 00:00:00

  • Interference of fetal hemoglobin with the spectrophotometric measurement of carboxyhemoglobin.

    abstract::We measured the concentration of carboxyhemoglobin (HbCO) in blood samples from 32 neonates by spectrophotometry (IL282 CO-Oximeter) and gas chromatography, finding a strong positive correlation (r = 0.89) between the concentration of fetal hemoglobin (Hb F) and HbCO as measured by spectrophotometry, but not by gas ch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vreman HJ,Ronquillo RB,Ariagno RL,Schwartz HC,Stevenson DK

    更新日期:1988-05-01 00:00:00

  • Direct radioimmunoassay for serum estriol during pregnancy.

    abstract::I describe an assay for serum estriol during pregnancy, which does not require prior extraction or chromatography of the serum. Fifty microliters of 20-fold diluted serum can be assayed to detect as little as 20 pg of estriol. For a 20 mug/liter serum estriol concentration the CV was 16%; for 100 mug/liter concentrati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Standefer J

    更新日期:1976-04-01 00:00:00

  • Alanine aminopeptidase in serum: automated optimized assay, and effects of age, sex, smoking, and alcohol consumption in a selected population.

    abstract::In the diagnosis of chronic (as opposed to acute) liver diseases, combinations of indicators are needed to improve specificity. Alanine aminopeptidase (AAP; microsomal aminopeptidase, EC 3.4.11.2) activity in serum reportedly is a very sensitive indicator of intrahepatic cholestasis and biliary obstruction; it is also...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mueller PW,Phillips DL,Steinberg KK

    更新日期:1987-03-01 00:00:00

  • Continuous determination of the oxygen dissociation curve for whole blood.

    abstract::We report here the development of a new method that allows continuous determination of the oxygen dissociation curve for microsamples (600 mul) of whole blood under conditions of pH, pCO2, methemoglobin concentration, and 2,3-diphosphoglycerate content closely approaching those found in the circulatory system. The met...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rossi-Bernardi L,Luzzana M,Samaja M,Davi M,DaRiva-Ricci D,Minoli J,Seaton B,Berger RL

    更新日期:1975-11-01 00:00:00

  • Comparison of quality-control rules used in clinical chemistry laboratories.

    abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bishop J,Nix AB

    更新日期:1993-08-01 00:00:00