A simple, direct radioimmunoassay for plasma cortisol, featuring a 125I radioligand and a solid-phase separation technique.

Abstract:

:A simple, direct radioimmunoassay for cortisol in human serum and plasma is described. An antiserum, raised in sheep to a cortisol-3-(O-carboxymethyl)oxime/bovine serum albumin conjugate, is coupled to microcellulose. No extraction is required because plasma samples and standards are incubated with the antiserum and an 125I radioligand in a low-pH buffer, which denatures cortisol-binding globulins. The assay satisfies accepted validation criteria. In addition, results from the radioimmunoassay compare well with those obtained by a gas chromatographic-mass spectrometric technique (r = 0.968; FRIA = 0.97 FGCMS + 2.0 nmol/L). The latter procedure features the very high intrinsic specificity obtained by selected ion monitoring at high mass-spectrometric resolution (M/deltaM = 8500) with a Varian MAT-731 instrument. The simplicity of the radioimmunoassay procedure, with use of reagents prepared "in house," makes this a very practical and economical assay for use in the medium or large endocrine laboratory.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Riad-Fahmy D,Read GF,Gaskell SJ,Dyas J,Hindawi R

subject

Has Abstract

pub_date

1979-05-01 00:00:00

pages

665-8

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

25

pub_type

杂志文章
  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Immunological and colorimetric determination of prostatic acid phosphatase--technical and clinical reappraisal in symptomatic patients.

    abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibb I,Wilson LA,Powell PH,Tarbit I,Pratt D,Hall RR

    更新日期:1986-09-01 00:00:00

  • Leukocyte counts in cerebrospinal fluid with the automated hematology analyzer CellDyn 3500 and the urine flow cytometer UF-100.

    abstract:BACKGROUND:The counting of leukocytes and erythrocytes in cerebrospinal fluid (CSF) is still performed microscopically, e.g., using a chamber in most laboratories. This requires sufficient practical experience, is time-consuming, and may constitute a problem in emergency diagnostics. Specific automated systems for CSF ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ziebig R,Lun A,Sinha P

    更新日期:2000-02-01 00:00:00

  • Measurement of the complex between prostate-specific antigen and alpha1-protease inhibitor in serum.

    abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Zhang WM,Finne P,Leinonen J,Vesalainen S,Nordling S,Stenman UH

    更新日期:1999-06-01 00:00:00

  • More sensitive flameless atomic absorption analysis of vanadium in tissue and serum.

    abstract::We describe a sensitive method for the determination of vanadium in biological substances by atomic absorption spectroscopy. By using background correction and pyrolytically coated graphite tubes with flameless apparatus, this vanadium assay has a sensitivity of 65 pg and a detection limit of 30 pg, approximately sixf...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stroop SD,Helinek G,Greene HL

    更新日期:1982-01-01 00:00:00

  • 3H and 125I radioimmunoassays of haloperidol compared with fluoroimmunoassay involving antibody coupled to magnetizable solid phase.

    abstract::Radioimmunoassays for haloperidol are described, involving use of tritium- or 125I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also desc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rowell FJ,Hui SM,Kamel SR

    更新日期:1981-07-01 00:00:00

  • Age-specific distribution of plasma amino acid concentrations in a healthy pediatric population.

    abstract::Reference values were determined for 23 plasma free amino acids from measurements done in 148 healthy children ranging from 0 to 18 years of age. Amino acid analysis was performed by ion-exchange chromatography. We propose a graphic form of presenting the age-specific distribution of plasma amino acid concentrations w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lepage N,McDonald N,Dallaire L,Lambert M

    更新日期:1997-12-01 00:00:00

  • Flow-injection analysis with chemiluminescence detection.

    abstract::In "flow-injection analysis," the sample is inserted into a stream of reagent by use of a sample-injection valve. Mixing occurs downstream from the valve in a coil of tubing. With chemiluminescence detection this coil is positioned in front of a photomultiplier. We have evaluated the system for detection of hydrogen p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rule G,Seitz WR

    更新日期:1979-09-01 00:00:00

  • Low proportions of glycosylated hemoglobin associated with hemoglobin S and hemoglobin C.

    abstract::Using a cation-exchange chromatographic method, we found normal or subnormal values for glycosylated hemoglobin in a few diabetic patients with persistent hyperglycemia. Subsequent investigations revealed that these unexpected results had originated from black patients with diabetes. In view of common occurrence of ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aleyassine H

    更新日期:1979-08-01 00:00:00

  • A tandem mass spectrometry triplex assay for the detection of Fabry, Pompe, and mucopolysaccharidosis-I (Hurler).

    abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.152009

    authors: Duffey TA,Bellamy G,Elliott S,Fox AC,Glass M,Turecek F,Gelb MH,Scott CR

    更新日期:2010-12-01 00:00:00

  • Why is the laboratory an afterthought for managed care organizations?

    abstract::Market forces have dramatically influenced the environment in which healthcare is delivered, but these changes do not need to be interpreted negatively by community laboratorians. Only total vertical integration of laboratory medicine can control episode-of-care cost. Opportunities also exist for horizontal integratio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Forsman RW

    更新日期:1996-05-01 00:00:00

  • Serum concentrations of cross-linked N-telopeptides of type I collagen: new marker for bone resorption in hemodialysis patients.

    abstract:BACKGROUND:Urinary cross-linked N-telopeptide of type I collagen (NTX) is a reliable bone resorption marker in patients with metabolic bone disease. We assessed a clinically available serum NTX assay suitable for anuric patients on hemodialysis (HD). METHODS:Serum concentrations of NTX, C-terminal telopeptide of type ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051524

    authors: Maeno Y,Inaba M,Okuno S,Yamakawa T,Ishimura E,Nishizawa Y

    更新日期:2005-12-01 00:00:00

  • Iron stores, blood donation, and insulin sensitivity and secretion.

    abstract:BACKGROUND:Epidemiologists have observed that blood donation is associated with decreased risk of type 2 diabetes and cardiovascular disease. METHODS:We investigated the relationship between iron stores and insulin sensitivity, after controlling for known confounding factors, and compared insulin sensitivity between b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046847

    authors: Fernández-Real JM,López-Bermejo A,Ricart W

    更新日期:2005-07-01 00:00:00

  • Use of two reporter dyes without interference in a single-tube rapid-cycle PCR: alpha(1)-antitrypsin genotyping by multiplex real-time fluorescence PCR with the LightCycler.

    abstract:BACKGROUND:alpha(1)-Antitrypsin is the major plasma serine protease inhibitor. Its deficiency is mainly associated with the alleles PI*S and PI*Z and can lead to obstructive lung disease in adults and to liver cirrhosis during childhood. METHODS:A multiplex PCR method has been established that uses two sets of primers...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Oellerich M,Schütz E

    更新日期:2000-02-01 00:00:00

  • Detection of biological threat agents by real-time PCR: comparison of assay performance on the R.A.P.I.D., the LightCycler, and the Smart Cycler platforms.

    abstract:BACKGROUND:Rapid detection of biological threat agents is critical for timely therapeutic administration. Fluorogenic PCR provides a rapid, sensitive, and specific tool for molecular identification of these agents. We compared the performance of assays for 7 biological threat agents on the Idaho Technology, Inc. R.A.P....

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052522

    authors: Christensen DR,Hartman LJ,Loveless BM,Frye MS,Shipley MA,Bridge DL,Richards MJ,Kaplan RS,Garrison J,Baldwin CD,Kulesh DA,Norwood DA

    更新日期:2006-01-01 00:00:00

  • A systematic approach to materials handling in clinical laboratories.

    abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nabb DP

    更新日期:1990-09-01 00:00:00

  • Reference centiles for serum ferritin and percentage of transferrin saturation, with application to mutations of the HFE gene.

    abstract:BACKGROUND:The gene that causes most cases of hereditary hemochromatosis is designated HFE. Individuals with mutations in the HFE gene may have increased serum iron, transferrin saturation, and ferritin concentrations relative to individuals with the wild-type genotype. METHODS:We generated reference centiles for perc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koziol JA,Ho NJ,Felitti VJ,Beutler E

    更新日期:2001-10-01 00:00:00

  • Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A(1c), IgA, prolactin, and free testosterone in healthy women.

    abstract:BACKGROUND:Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within- (CV(i)) an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garde AH,Hansen AM,Skovgaard LT,Christensen JM

    更新日期:2000-04-01 00:00:00

  • Multicenter evaluation of Iso-ALP test kit for measurement of bone alkaline phosphatase activity in serum and plasma.

    abstract::A test kit (Iso-ALP, Boehringer Mannheim) for measuring human bone alkaline phosphatase activity in serum or plasma was evaluated in five laboratories in three countries. The assay is based on the principle described by Rosalki and Foo (Clin Chem 1984;30:1182-6) and uses wheat germ lectin to precipitate bone alkaline ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rosalki SB,Foo AY,Burlina A,Prellwitz W,Stieber P,Neumeier D,Klein G,Poppe WA,Bodenmüller H

    更新日期:1993-04-01 00:00:00

  • Plasma apolipoproteins A-I and B in survivors of myocardial infarction and in a control group.

    abstract::The values of apolipoproteins (apo) A-I and B were determined in a population sample of hospital outpatients with a standardized method to verify if the cutpoints calculated in a cross-sectional study in the US are usable with other populations. We also tested the apolipoproteins' ability to discriminate between healt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graziani MS,Zanolla L,Righetti G,Marchetti C,Mocarelli P,Marcovina SM

    更新日期:1998-01-01 00:00:00

  • Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.

    abstract::We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Christenson RH,Clemmensen P,Ohman EM,Toffaletti J,Silverman LM,Grande P,Vollmer RT,Wagner GS

    更新日期:1990-08-01 00:00:00

  • Clinical applications of protein determinations in biological fluids other than blood.

    abstract::Over the past decade, significant improvements in immunochemical and electrophoretic techniques have enabled collection of heretofore unavailable data on proteins in biological fluids, greatly increasing our understanding of protein physiology in the various body compartments and providing the foundation for clinical ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Killingsworth LM

    更新日期:1982-05-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • Enzymic inhibition assay for methotrexate with a discrete analyzer, the ABA-100.

    abstract::We adapted an inhibition assay for methotrexate, involving dihydrofolate reductase from bovine liver, for use with a discrete analyzer (the ABA-100). The analyzer was used both for dilution and a 5-min pre-incubation of the sample with NADPH--enzyme reagent, and for the assay itself. The standard curve was linear betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown LF,Johnson GF,Witte DL,Feld RD

    更新日期:1980-02-01 00:00:00

  • Polymorphisms in inflammatory genes and the risk of ischemic stroke and transient ischemic attack: results of a multilocus genotyping assay.

    abstract:BACKGROUND:Single-nucleotide polymorphisms (SNPs) in inflammation-related genes have been linked to an increased risk of ischemic stroke. Most of these SNP results have not been replicated, however, and metaanalyses of the effects of inflammation-related genes are rare. We investigated 49 SNPs in 34 genes previously re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.112151

    authors: Greisenegger S,Zehetmayer S,Bauer P,Endler G,Ferrari J,Lang W,Janisiw M,Steiner L,Cheng S,Lalouschek W,Mannhalter C

    更新日期:2009-01-01 00:00:00

  • Improved isocratic liquid-chromatographic simultaneous measurement of phenytoin, phenobarbital, primidone, carbamazepine, ethosuximide, and N-desmethylmethsuximide in serum.

    abstract::We describe an improved "high-pressure" liquid-chromatographic assay for simultaneous determination in serum of the five major antiepileptic drugs (ethosuximide, primidone, phenobarbital, phenytoin, and carbamazepine) and N-desmethylmethsuximide (the compound that must be quantitated for therapeutic drug monitoring of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Szabo GK,Browne TR

    更新日期:1982-01-01 00:00:00

  • Global sequencing approach for characterizing the molecular background of hereditary iron disorders.

    abstract:BACKGROUND:New genetic forms of hereditary hemochromatosis (HH) or hereditary hyperferritinemia (HF) have been identified over the last few years, and abnormalities of various genes may interact in a single patient. This study aimed to develop a rapid automated method for sequencing the main genes involved. METHODS:We...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090605

    authors: Cunat S,Giansily-Blaizot M,Bismuth M,Blanc F,Dereure O,Larrey D,Quellec AL,Pouderoux P,Rose C,Raingeard I,Renard E,Schved JF,Aguilar-Martinez P,CHU Montpellier AOI 2004 Working Group.

    更新日期:2007-12-01 00:00:00

  • Measurement of different forms of tissue plasminogen activator in plasma.

    abstract:BACKGROUND:We evaluated assays to measure both total tissue plasminogen activator (tPA) and the three principle forms of tPA in plasma: active tPA, tPA complexed with plasminogen activator inhibitor type 1 (PAI-1), and tPA complexed with C1-inhibitor. METHODS:Active tPA was measured by use of an indirect amidolytic as...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chandler WL,Jascur ML,Henderson PJ

    更新日期:2000-01-01 00:00:00

  • The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

    abstract::We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. un...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilke TJ,Utley DJ

    更新日期:1988-07-01 00:00:00

  • Statistical interpretation of concentrations of magnesium, zinc, calcium, potassium, cholesterols, and creatine kinase isoenzymes in men at different stages of ischemic heart disease.

    abstract::We present a statistical interpretation of plasma (Pl) and (or) erythrocyte (Erc) concentrations of magnesium, zinc, calcium, potassium, and total high-density lipoprotein (HDL) cholesterol, as well as of the activity of total creatine kinase (CK) and its CK-MB isoenzyme, in 26 men with pre-infarction syndrome (PIS) a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Speich M,Auget JL,Arnaud P

    更新日期:1989-05-01 00:00:00