Abstract:
:This two-site immunoradiometric assay for human parathyrin-related protein 1-86 (PTHRP1-86) in plasma uses a mouse monoclonal antibody to PTHRP1-34 coupled to cellulose particles for immunoextraction of N-terminal immunoreactivity, and a rabbit antiserum to PTHRP37-67 that is indirectly labeled with 125I-labeled PTHRP37-67 for quantifying the bound analyte. The detection limit of the assay is 0.23 pmol/L, corresponding to 0.4 pg (0.04 fmol) per tube, for a sample volume of 200 microL. Recovery of PTHRP1-86 added to serum is essentially quantitative, and within- and between-batch precision is 4.4% and 11.1%, respectively. PTH1-84, PTHRP18-34, PTHRP9-34, PTHRP1-34, and PTHRP37-67 do not cross-react in the assay at concentrations up to 2 nmol/L. Plasma concentrations of PTHRP1-86 were below or close to the detection limit of the assay in normal subjects and in patients with primary hyperparathyroidism, hypoparathyroidism, chronic renal failure, and normocalcemic malignancy. In 37 hypercalcemic patients with various malignancies, we found detectable PTHRP1-86 concentrations in 35 (95%, mean 7.4 pmol/L, range 0.46-24.7). The data support the proposed humoral role of PTHRP in cancer-associated hypercalcemia and suggest that the assay has clinical utility in the differential diagnosis of hypercalcemia.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Ratcliffe WA,Norbury S,Heath DA,Ratcliffe JGsubject
Has Abstractpub_date
1991-05-01 00:00:00pages
678-85issue
5eissn
0009-9147issn
1530-8561journal_volume
37pub_type
杂志文章abstract:BACKGROUND:B-type natriuretic peptide (BNP), which is activated in heart failure (HF), is processed to an active form by corin. The corin gene is expressed in the human heart and kidney, but corin protein expression in the heart, kidney, and circulation, along with whether proBNP is processed by circulating corin, rema...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.153908
更新日期:2011-01-01 00:00:00
abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-05-01 00:00:00
abstract::We have developed a sensitive procedure for determination of serum copper by use of the color reagent 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-sulfopropylaniline. After mixing serum sample and reagent, and incubating at 37 degrees C for 5 min, we measure the absorbance of the resulting chelate complex at 580 nm (molar a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-04-01 00:00:00
abstract:BACKGROUND:Measurement of hemoglobin A1c (HbA1c) in the blood is integral to and essential for the treatment of patients with diabetes mellitus. HbA1c reflects the mean blood glucose concentration over the preceding 8 to 12 weeks. Although the clinical value of HbA1c was initially limited by large differences in result...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2018.296962
更新日期:2019-07-01 00:00:00
abstract:BACKGROUND:Urinary cross-linked N-telopeptide of type I collagen (NTX) is a reliable bone resorption marker in patients with metabolic bone disease. We assessed a clinically available serum NTX assay suitable for anuric patients on hemodialysis (HD). METHODS:Serum concentrations of NTX, C-terminal telopeptide of type ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.051524
更新日期:2005-12-01 00:00:00
abstract:BACKGROUND:Functional antibody surfaces were prepared on ultraflat polystyrene surfaces by physical adsorption, and the uniform distribution of monoclonal antibodies against hepatitis B surface antigen (anti-HBs) on such surfaces and the presence of dense hepatitis B surface antigen (HBsAg) particles captured by immobi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::A monoclonal-antibody-based competitive radioimmunoassay for measuring human protein C is reported. With use of a purified protein C standard, the solid-phase assay was sensitive to less than 80 micrograms of protein C per liter. Intraassay CVs ranged from 5% to 8%; the inter-assay CV was 5.4%. Analytical recovery ave...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-02-01 00:00:00
abstract:BACKGROUND:We describe a simple tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) for detecting MUTYH mutations, which are associated with colorectal adenomas and colorectal cancer. METHODS:We designed specific T-ARMS-PCR assays for 6 mutations (Y165C, G382D, 1395_7delGGA, Y90X, 1103delC, and R231...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.060137
更新日期:2006-04-01 00:00:00
abstract::The objective of this study was to develop a clinical laboratory method for subclass typing of human immunoglobulin G (IgG) paraproteins. Serum proteins were isoelectrically focused (IEF) in a mini-gel and passively blotted by capillary diffusion onto untreated nitrocellulose. Unreacted sites on the nitrocellulose wer...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-03-01 00:00:00
abstract::We describe an improved procedure for the preparation of plasma or serum for determination of theophylline by reverse phase high-performance liquid chromatography. Quantitative results are available in less than 30 min from receipt of sample. The chromatogram is complete in 8 to 16 min, which includes the use of an in...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract:BACKGROUND:Identifying novel risk markers in cardiovascular patients remains a research priority. Longer follow-up generally is considered favorable in such studies, but associations of interest may become attenuated with increasing follow-up. This issue has not been adequately addressed in the context of patient cohor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.263202
更新日期:2017-03-01 00:00:00
abstract:BACKGROUND:External quality assurance (EQA) programs for diagnostic tests based on nucleic acid amplification have not been widely implemented in clinical laboratories and remain limited to few tests. Development of specific EQA programs based on application-based proficiency testing for any diagnostic molecular target...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.5.782
更新日期:2003-05-01 00:00:00
abstract::Seeking to minimize degradation of NADPH during storage, reagent preparation, and assays, we investigated the effects of pH, temperature, and ionic strength as well as the effects of phosphate and acetate. NADH was also included for comparison. Our results indicate that the rate of degradation of NADPH is proportional...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-02-01 00:00:00
abstract::A new radiometric assay specific for creatine kinase isoenzyme MB was evaluated with respect to its precision and agreement with a conventional electrophoretic CK-MB assay for the diagnosis of myocardial infarction. The reference interval we find for serum CK-MB in healthy subjects is 0--30 micrograms/L. The coefficie...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-06-01 00:00:00
abstract::We describe a gas-chromatographic method for measuring chlorpromazine and its metabolites chlorpromazine sulfoxide, mono-N-desmethylchlorpromazine, and di-N-desmethylchlorpromazine at therapeutic concentrations in human serum, with use of a nitrogen detector. The compounds are extracted from serum at pH 10.5 into hexa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-07-01 00:00:00
abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract:BACKGROUND:Risk assessments of patients should be based on objective variables, such as biological markers that can be measured routinely. The acute response to stress causes the release of catecholamines from the adrenal medulla accompanied by chromogranin A (CGA). To date, no study has evaluated the prognostic value ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.102442
更新日期:2008-09-01 00:00:00
abstract::Using a continuous-flow (Technicon SMAC) analyzer, we measured the concentration of 20 analytes in capillary blood sera from 149 neonates in an intensive-care unit. Included were term and pre-term babies, both groups with and without asphyxia. The values obtained, especially for those enzymes and analytes that are rel...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-04-01 00:00:00
abstract::We have improved the protocol for RNA quantification by using RNase protection. Instead of precipitation and extraction with phenol and chloroform, we use a faster and more reliable precipitation based on guanidinium thiocyanate (GdSCN). The internal standard is produced by in vitro transcription of a DNA template con...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-11-01 00:00:00
abstract::To study the effect of fatty acid chain saturation on the fluorescence polarization assay as a measure of fetal lung maturity, we used purified phospholipids isolated from human amniotic fluid and various commercial phospholipids. We found that the fluorescence polarization value decreased as the concentration of unsa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-03-01 00:00:00
abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-02-01 00:00:00
abstract::Detection of intracellular antigens by flow cytometry requires effective fixation and permeabilization of the cell membrane. This study compares three fixation/permeabilization techniques: two commercial chemical reagents, the ORTHOPermeaFix (OPF) and the FIX&PERM Cell Permeabilization Kit (F&P), and a novel method ba...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-11-01 00:00:00
abstract::Quantification of ethanol by a radiative energy attenuation (REA) technique was evaluated and compared with results by gas-liquid chromatography (GLC) and by the Du Pont aca. Within-assay CVs were less than 5.5%. Between-assay CVs ranged from 1.9% to 6.0% for serum and blood controls at concentrations of 0.5, 1.0, and...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-11-01 00:00:00
abstract::We devised a method for assaying serum lactate dehydrogenase isoenzyme 1 (LD-1) activity specifically by preincubation with alpha-chymotrypsin and guanidine. Cleavage of phenylalanine bonds in the loop of A and B subunits of LD-3, LD-4, and LD-5 isoenzymes (residues 117-119) by incubation with alpha-chymotrypsin for a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-11-01 00:00:00
abstract::Methods for measuring thyroid autoantibodies--to thyroperoxidase (TPOAb), thyroglobulin (TgAb), and thyrotropin receptor (TRAb)--have improved over the last decade, but increasingly, accurate and sensitive methods are needed for identifying patients with autoimmune thyroid diseases and individuals at high risk for ons...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1996-01-01 00:00:00
abstract::We isolated myoglobin from sheep heart by homogenizing cardiac muscle in 70%-saturated ammonium sulfate, followed by chromatography on a column containing carboxymethyl(CM)-Sephadex gel. Two major isoforms of myoglobin, designated Mb 7.9 and Mb 8.1, were separated by chromatofocusing and were distinguished by their di...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-05-01 00:00:00
abstract::We examined the cholesterol/protein ratio and the apoprotein composition of serum lipoproteins in a randomly selected population of maturity-onset diabetics and in a group of nondiabetics of similar age. We found no differences in cholesterol distribution between the groups as a whole, but diabetics with above-normal ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-08-01 00:00:00
abstract::To investigate the use of streptavidin-hapten derivatives as potential protein-tracer conjugates for competitive-type immunoassays, we labeled streptavidin with cortisol and compared biotin-binding activity of the conjugates with that of unlabeled streptavidin. In this model system, streptavidin labeled with one to ap...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-01-01 00:00:00
abstract::We immunoenzymometrically measured creatine kinase (CK) isoenzyme MB in extracts of myocardium and in homogenates of five different skeletal muscles. CK-MB concentrations in the former averaged 80.9 micrograms/g wet tissue; in the skeletal muscles it varied widely, being (e.g.) 25-fold greater in diaphragm than in pso...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-02-01 00:00:00
abstract:BACKGROUND:Testing for troponin has important clinical value for patients who present with typical symptoms of acute coronary syndromes (ACS) such as chest pain (CP). Much less is known about the value of troponin testing for patients who present with other symptoms of ACS (anginal equivalent symptoms). METHODS:The ut...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.016311
更新日期:2004-01-01 00:00:00