A monoclonal-antibody-based radioimmunoassay for measurement of protein C in plasma.

Abstract:

:A monoclonal-antibody-based competitive radioimmunoassay for measuring human protein C is reported. With use of a purified protein C standard, the solid-phase assay was sensitive to less than 80 micrograms of protein C per liter. Intraassay CVs ranged from 5% to 8%; the inter-assay CV was 5.4%. Analytical recovery averaged 104% for purified protein C added to 10 samples of normal plasmas. The assay antibody could deplete plasma of all protein C, as determined by immunoaffinity chromatography followed by polyclonal Western blot analysis. Liquid-chromatographic gel permeation of plasma indicated a single immunoreactive species that had an appropriate molecular mass for monomeric protein C. Studies of monoclonal-antibody specificity showed no significant interferences by other vitamin K-dependent proteins. The mean protein C antigen concentration in plasma of 54 healthy subjects was 3.21 (SD 0.56) mg/L and was 1.51 (SD 0.52) mg/L for 22 patients on long-term warfarin therapy. Results of the monoclonal RIA correlated well with those by a polyclonal RIA also developed in our laboratory (r = 0.93) and an amidolytic functional assay (r = 0.88) for both normal plasma and plasma from patients on long-term warfarin therapy.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Howard PR,Bovill EG,Mann KG,Tracy RP

subject

Has Abstract

pub_date

1988-02-01 00:00:00

pages

324-30

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

34

pub_type

杂志文章
  • Quantification and utility of monosialylated alpha-fetoprotein in the diagnosis of hepatocellular carcinoma with nondiagnostic serum total alpha-fetoprotein.

    abstract:BACKGROUND:At concentrations <500 microg/L, serum alpha-fetoprotein (AFP) has low specificity in the diagnosis of hepatocellular carcinoma (HCC), but monosialylated AFP (msAFP) is more specific for HCC. We describe two strategies for quantitative analysis of msAFP and explore their diagnostic accuracy in cases of HCC w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Poon TC,Mok TS,Chan AT,Chan CM,Leong V,Tsui SH,Leung TW,Wong HT,Ho SK,Johnson PJ

    更新日期:2002-07-01 00:00:00

  • Production of murine hybrid-hybridomas secreting bispecific monoclonal antibodies for use in urease-based immunoassays.

    abstract::To produce bispecific antibodies (BiAbs) for enzyme immunoassay (EIA) to replace antibody-enzyme conjugates, we developed a panel of 8-azaguanine/ouabain-resistant anti-urease variant hybridoma cell lines for use in hybridoma-hybridoma fusions. These variants represent mouse immunoglobulin subclasses IgM, IgG1, IgG2a,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Takahashi M,Fuller SA

    更新日期:1988-09-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Multi-wavelength analyses of second-derivative spectra for rapid determination of acetaminophen in serum.

    abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dingeon B,Charvin MA,Quenard MT,Thome H

    更新日期:1988-06-01 00:00:00

  • Applications of MALDI Mass Spectrometry in Clinical Chemistry.

    abstract:BACKGROUND:MALDI-TOF mass spectrometry (MS) is set to make inroads into clinical chemistry because it offers advantages over other analytical platforms. These advantages include low acquisition and operating costs, ease of use, ruggedness, and high throughput. When coupled with innovative front-end strategies and appli...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239491

    authors: Duncan MW,Nedelkov D,Walsh R,Hattan SJ

    更新日期:2016-01-01 00:00:00

  • Personalized medicine in diabetes.

    abstract:BACKGROUND:Multiple genes that are associated with the risk of developing diabetes or the risk of diabetes complications have been identified by candidate gene analysis and genomewide scanning. These molecular markers, together with clinical data and findings from proteomics, metabolomics, pharmacogenetics, and other m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2010.156901

    authors: Malandrino N,Smith RJ

    更新日期:2011-02-01 00:00:00

  • Reversible myocardial ischemic injury is not associated with increased creatine kinase activity in plasma.

    abstract::Creatine kinase (CK) isoenzymes MM, MB, and BB are located primarily in the cell cytosol, and increased CKMB in plasma is the hallmark of myocardial infarction. However, whether CK is released with reversible ischemic injury remains controversial. Here, we assessed plasma CK activity--cytosolic and mitochondrial CK--i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ishikawa Y,Saffitz JE,Mealman TL,Grace AM,Roberts R

    更新日期:1997-03-01 00:00:00

  • Rate nephelometric measurement of rheumatoid factor in serum.

    abstract::We describe the measurement of rheumatoid factor in human sera with a rate nephelometer. The National Reference Preparation for Rheumatoid Factors is used to calibrate the assay in International Units. We used Hyland Positive Control, Level I, as a secondary standard. The standard curve is exponential, but is linear w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Hicks MJ,Williams RJ,Hinlicky J,Lichti DA

    更新日期:1979-11-01 00:00:00

  • Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

    abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Gerhardt W,Nordin G,Herbert AK,Burzell BL,Isaksson A,Gustavsson E,Haglund S,Müller-Bardorff M,Katus HA

    更新日期:2000-06-01 00:00:00

  • Quantification of urinary porphyrins by liquid chromatography after oxidation of porphyrinogens.

    abstract::A quantitative "high-performance" liquid-chromatographic method is described for determining porphyrins in human urine. Porphyrinogens in urine are first converted to the corresponding porphyrins by oxidation with iodine. Uroporphyrin, hepatacarboxylic acid porphyrin, hexacarboxylic acid porphyrin, pentacarboxylic aci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe K,Konaka R

    更新日期:1989-08-01 00:00:00

  • Interference by p-hydroxyphenobarbital in the 125I-radioimmunoassay of serum and urinary phenobarbital.

    abstract::A radioimmunoassay for barbiturates is shown to be equally sensitive to phenobarbital and its major urinary metabolite, p-hydroxyphenobarbital, in serum and urine. Interference by the metabolite can be essentially eliminated by selectively extracting phenobarbital into chloroform. The extraction efficiency of the meth...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Viswanathan CT,Booker HE,Welling PG

    更新日期:1977-05-01 00:00:00

  • Analytical goals developed from the inherent error of medical tests.

    abstract::Biological variation is inherent in all medical tests and is a major source of error in clinical test interpretation. We use inherent test error due to biological variability as the touchstone by which to validate the clinical acceptability of analytical goals. Analytical goals should consist of sets of complementary ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ross JW,Fraser MD

    更新日期:1993-07-01 00:00:00

  • Evaluation of the dual-precipitation method by comparison with the ultracentrifugation method for measurement of lipoproteins in serum.

    abstract::We evaluated the dual-precipitation method for quantitative measurement of lipoproteins as described by Wilson and Spiger [J. Lab. Clin. Med. 82, 473 (1973)] for normo- and hyperlipemic sera, by comparison with the results obtained with ultracentrifugation. If serum with an above-normal triglyceride concentration is a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,Vos-Janssen HE,Jansen AP,van 't Laar A

    更新日期:1977-07-01 00:00:00

  • Urothelial Carcinoma Detection Based on Copy Number Profiles of Urinary Cell-Free DNA by Shallow Whole-Genome Sequencing.

    abstract:BACKGROUND:Current noninvasive assays for urothelial carcinoma (UC) lack clinical sensitivity and specificity. Given the utility of plasma cell-free DNA (cfDNA) biomarkers, the development of urinary cfDNA biomarkers may improve the diagnostic sensitivity. METHODS:We assessed copy number alterations (CNAs) by shallow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.309633

    authors: Ge G,Peng D,Guan B,Zhou Y,Gong Y,Shi Y,Hao X,Xu Z,Qi J,Lu H,Zhang X,Zhan Y,Li Y,Wu Y,Ding G,Shen Q,He Q,Li X,Zhou L,Ci W

    更新日期:2020-01-01 00:00:00

  • A clinical chemistry analyzer evaluated by NCCLS guidelines for use in a military field laboratory unit.

    abstract::In a previous comparison study of "dry chemistry" desktop analyzers, the ChemPro 1000 (Arden Medical Systems) was one of several instruments found suitable for field use. We have now evaluated the linearity, accuracy, and precision of the ChemPro 1000, according to NCCLS Document EP 10-P. We also compared results with...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sullinger J,Garrett PE

    更新日期:1989-11-01 00:00:00

  • Performance of an enzyme-linked immunosorbent assay system for antibodies to hepatitis C virus with two new antigens (c11/c7).

    abstract::We developed an enzyme-linked immunosorbent assay (ELISA) system for antibodies to the hepatitis C virus (HCV), using two new recombinant antigens (c11 and c7) derived from the HCV genome. The performance of this ELISA system (Imucheck HCV Ab) was examined. The CV values for both intra-assay precision and reproducibil...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Saito M,Hasegawa A,Kashiwakuma T,Kohara M,Sugi M,Miki K,Yamamoto T,Mori H,Ohta Y,Tanaka E

    更新日期:1992-12-01 00:00:00

  • P-selectin- and CD63-exposing platelet microparticles reflect platelet activation in peripheral arterial disease and myocardial infarction.

    abstract:BACKGROUND:Platelet-derived microparticles (PMPs) are generally considered a marker of platelet activation in cardiovascular disease. We studied the extent to which PMP subpopulations parallel platelet activation in vitro and in vivo. METHODS:Using flow cytometry, we analyzed PMP subpopulations from resting and activa...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.057414

    authors: van der Zee PM,Biró E,Ko Y,de Winter RJ,Hack CE,Sturk A,Nieuwland R

    更新日期:2006-04-01 00:00:00

  • Systematic Review and Metaanalysis Comparing the Bias and Accuracy of the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration Equations in Community-Based Populations.

    abstract:BACKGROUND:The majority of patients with chronic kidney disease are diagnosed and monitored in primary care. Glomerular filtration rate (GFR) is a key marker of renal function, but direct measurement is invasive; in routine practice, equations are used for estimated GFR (eGFR) from serum creatinine. We systematically a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2017.276683

    authors: McFadden EC,Hirst JA,Verbakel JY,McLellan JH,Hobbs FDR,Stevens RJ,O'Callaghan CA,Lasserson DS

    更新日期:2018-03-01 00:00:00

  • Multiple drugs of abuse in urine detected with a single reagent and fluorescence polarization.

    abstract::We describe a simple polarization fluoroimmunoassay for the detection of several commonly abused drugs in urine. The single reagent used, prepared by mixing four different antisera and three fluorescein-labeled derivatives, produces a polarization signal that is the average of the individual signals of the derivatives...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Childerstone M

    更新日期:1987-10-01 00:00:00

  • Enzyme-linked immunosorbent assay for 17 alpha-hydroxyprogesterone in dried blood spotted on filter paper.

    abstract::In this rapid, cost-effective, enzyme-linked immunosorbent assay for 17 alpha-hydroxyprogesterone (17-OHP) eluted from dried blood spotted on filter paper, second antibody is coated onto the microwell plate and horseradish peroxidase (EC 1.11.1.7) is the label enzyme. Antiserum to 17-OHP was prepared by using 4-(2-car...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maeda M,Arakawa H,Tsuji A,Yamagami Y,Isozaki A,Takahashi T,Haruki E

    更新日期:1987-06-01 00:00:00

  • HemoCue beta-glucose photometer evaluated for use in a neonatal intensive care unit.

    abstract::We evaluated the HemoCue beta-Glucose Photometer system for use in our neonatal intensive care unit by assaying 178 heparinized whole-blood samples obtained by heel stick. The required sample size is 5 microL. Plasma glucose was analysed by a glucose oxidase/oxygen electrode methodology. Across the glucose range of 1....

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vadasdi E,Jacobs E

    更新日期:1993-11-01 00:00:00

  • Development and evaluation of quality control dried blood spot materials in newborn screening for lysosomal storage disorders.

    abstract:BACKGROUND:Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111864

    authors: De Jesus VR,Zhang XK,Keutzer J,Bodamer OA,Mühl A,Orsini JJ,Caggana M,Vogt RF,Hannon WH

    更新日期:2009-01-01 00:00:00

  • Washington University Case Conference: Theophylline toxicity.

    abstract::This case demonstrates the importance of monitoring theophylline concentrations in serum during therapy with this drug. The commonly used body-weight-derived guidelines for therapeutic dose are not adequate and do not preclude the necessity for such monitoring. The ultraviolet spectrophotometric methods available for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors:

    更新日期:1978-09-01 00:00:00

  • Laboratory costs in the context of disease.

    abstract:BACKGROUND:To determine the contribution of laboratory costs to the overall costs of managing hospital patients with different diseases, we studied the costs of laboratory testing overall and in relation to the other costs incurred during hospitalization. METHODS:We used a database developed by the University HealthSy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Young DS,Sachais BS,Jefferies LC

    更新日期:2000-07-01 00:00:00

  • Anti-free prostate-specific antigen monoclonal antibody epitopes defined by mimotopes and molecular modeling.

    abstract:BACKGROUND:Prostate-specific antigen (PSA) is an important marker for the diagnosis and management of prostate cancer, and the free PSA/total PSA ratio has been shown to be efficient for distinguishing prostate cancer from benign prostatic hyperplasia. We report here the characterization of seven mouse monoclonal antib...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Michel S,Deléage G,Charrier JP,Passagot J,Battail-Poirot N,Sibai G,Jolivet M,Jolivet-Reynaud C

    更新日期:1999-05-01 00:00:00

  • Use of polymerase chain reaction to detect heterozygous familial hypercholesterolemia.

    abstract::We used a modification of the polymerase chain reaction (PCR), involving two pairs of oligonucleotide primers, to detect a mutation in the low-density lipoprotein (LDL) receptor gene, commonly occurring among patients with familial hypercholesterolemia (FH) in Finland. This mutation, called FH-Helsinki, involves a lar...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Keinänen M,Ojala JP,Helve E,Aalto-Setälä K,Kontula K,Kovanen PT

    更新日期:1990-06-01 00:00:00

  • Fetal DNA in maternal plasma: biology and diagnostic applications.

    abstract:BACKGROUND:Molecular analysis of plasma DNA during human pregnancy has led to the discovery that maternal plasma contains both fetal and maternal DNA. This valuable source of fetal DNA opens up new possibilities for noninvasive prenatal diagnosis. APPROACH:Published data from the last 3 years demonstrating the feasibi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Lo YM

    更新日期:2000-12-01 00:00:00

  • Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.

    abstract::This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and rep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gault MH,Longerich L,Dawe M,Vasdev SC

    更新日期:1985-08-01 00:00:00

  • A model for medical decision making and problem solving.

    abstract::Clinicians confront the classical problem of decision making under uncertainty, but a universal procedure by which they deal with this situation, both in diagnosis and therapy, can be defined. This consists in the choice of a specific course of action from available alternatives so as to reduce uncertainty. Formal ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Werner M

    更新日期:1995-08-01 00:00:00

  • Kinetic determination of serum sorbitol dehydrogenase activity with a centrifugal analyzer.

    abstract::We describe a mechanized method for centrifugal analyzer determination of sorbitol dehydrogenase in serum, based on conversion of D-fructose to sorbitol with simultaneous oxidation of NADH, in triethanolamine buffer at pH 7.4 and 30 degrees C. The standard curve for this assay is linear to 200 U of activity per liter ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dooley JF,Turnquist LJ,Racich L

    更新日期:1979-12-01 00:00:00