Interference by p-hydroxyphenobarbital in the 125I-radioimmunoassay of serum and urinary phenobarbital.

Abstract:

:A radioimmunoassay for barbiturates is shown to be equally sensitive to phenobarbital and its major urinary metabolite, p-hydroxyphenobarbital, in serum and urine. Interference by the metabolite can be essentially eliminated by selectively extracting phenobarbital into chloroform. The extraction efficiency of the method for phenobarbital was 93+/-2% (SD) over the concentration range studied. Although cross reactivity between barbiturates and their metabolites may be less important in determining cases of barbiturates abuse or overdose, it may be extremely important if data on serum or urine are required for accurate estimates of drug disposition, or in establishing dose/response relationships.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Viswanathan CT,Booker HE,Welling PG

subject

Has Abstract

pub_date

1977-05-01 00:00:00

pages

873-6

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

23

pub_type

杂志文章
  • Kinetic serum creatinine assays I. The role of various factors in determining specificity.

    abstract::We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interfere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bowers LD

    更新日期:1980-04-01 00:00:00

  • Immunological and colorimetric determination of prostatic acid phosphatase--technical and clinical reappraisal in symptomatic patients.

    abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibb I,Wilson LA,Powell PH,Tarbit I,Pratt D,Hall RR

    更新日期:1986-09-01 00:00:00

  • Immunochemical determination of human immunoglobulins: use of kinetic turbidimetry and a 36-place centrifugal analyzer.

    abstract::We describe the measurement of human immunoglobulins IgG, IgA, and IgM in diluted sera, with diluted commercial monospecific antisera, with use of a 36-place centrifugal analyzer (RotoChem IIa; American Instrument Co., Silver Spring, MD 20920). The assay involves a two-point kinetic turbidimetric technique. The change...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Williams RJ,Lichti DA,Griffith F,Thies AC

    更新日期:1979-04-01 00:00:00

  • Thyroxine, thyrotropin, and age in a euthyroid hospital patient population.

    abstract::The diagnosis of thyroid disease now often can be achieved reliably by measuring thyrotropin (TSH) alone. Thyroxine (T4), triiodothyronine, and other analytes are only needed if TSH and the accompanying clinical condition are discordant. We describe here work that confirms the age independence of TSH in both inpatient...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davey R

    更新日期:1997-11-01 00:00:00

  • Use of monoclonal and polyclonal antibodies to detect prostatic acid phosphatase by immunoblotting.

    abstract::We investigated two techniques of immunoblotting--the Western blot and the dot blot--for use in detecting prostatic acid phosphatase (PAP, EC 3.1.3.2). We used polyclonal antisera to human PAP, produced in rabbits by hyperimmunization with purified PAP, and PAP-specific monoclonal antibodies in the immunoenzymatic pro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Patel PC,Aubin L,Côte J

    更新日期:1986-10-01 00:00:00

  • Analytical performance of Bayer Immuno 1 estradiol and progesterone assays.

    abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lévesque A,Letellier M,Dillon PW,Grant A

    更新日期:1997-09-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Rate of decrease in serum ethchlorvynol concentrations after extreme overdosage-a case study.

    abstract::Ethchlorvynol is a commonly abused sedative hypnotic. I report here a seven-day study of serum ethchlorvynol concentrations in a patient who had received an extreme overdose. These concentrations were correlated with the patient's response to stimuli. Serum ethchlorvynol concentrations were logarithmically related to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pochopien DJ

    更新日期:1975-06-01 00:00:00

  • Cardiac troponin T predicts long-term outcomes in hemodialysis patients.

    abstract:BACKGROUND:Increased plasma troponin T (cTnT), but not troponin I (cTnI), is frequently observed in end-stage renal failure patients. Although generally considered spurious, we previously reported an associated increased mortality at 12 months. METHODS:We studied long-term outcomes in 244 patients on chronic hemodialy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ooi DS,Zimmerman D,Graham J,Wells GA

    更新日期:2001-03-01 00:00:00

  • Proenzyme forms of prostate-specific antigen in serum improve the detection of prostate cancer.

    abstract:INTRODUCTION:Pro or precursor forms of prostate-specific antigen (PSA) have emerged as potentially important diagnostic serum markers for prostate cancer detection. Immunoassays were developed to measure specific proPSA forms containing propeptides of 2, 4, and 7 amino acids [(-2)proPSA, (-4)proPSA, and (-7)proPSA, res...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026823

    authors: Mikolajczyk SD,Catalona WJ,Evans CL,Linton HJ,Millar LS,Marker KM,Katir D,Amirkhan A,Rittenhouse HG

    更新日期:2004-06-01 00:00:00

  • Radioimmunoassay for detecting hepatitis B core antigen in serum from patients with chronic hepatitis B infection.

    abstract::The core antigen component of hepatitis B virus (HBV), HBcAg, may be used as a marker of viral replication. We describe a radioimmunoassay for HBcAg in serum, and compare results with those by other similar methods. Samples are centrifuged over a sucrose gradient containing 2-mercaptoethanol, and the resulting pellets...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quiroga JA,González O,Carreño V,Mora I,Porres JC,Gutiez J,Hernández-Guío C

    更新日期:1985-06-01 00:00:00

  • One-tube radiotransinassay for determination of cortisol at ambient temperature.

    abstract::After extraction of the sample (on filter paper) in the counting vial, cortisol is assayed by adding 50 microL of horse serum containing tritiated cortisol, and 2 mL of toluene scintillator, shaking for 20 min, and counting the radioactivity in a liquid-scintillation counter at ambient temperature. The method can be a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Murphy BE,Barta A

    更新日期:1987-07-01 00:00:00

  • SARS-CoV-2 Whole Genome Amplification and Sequencing for Effective Population-Based Surveillance and Control of Viral Transmission.

    abstract:BACKGROUND:With the gradual reopening of economies and resumption of social life, robust surveillance mechanisms should be implemented to control the ongoing COVID-19 pandemic. Unlike RT-qPCR, SARS-CoV-2 whole genome sequencing (cWGS) has the added advantage of identifying cryptic origins of the virus, and the extent o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa187

    authors: Harilal D,Ramaswamy S,Loney T,Suwaidi HA,Khansaheb H,Alkhaja A,Varghese R,Deesi Z,Nowotny N,Alsheikh-Ali A,Abou Tayoun A

    更新日期:2020-11-01 00:00:00

  • Simultaneous measurement of serum testosterone and dihydrotestosterone by liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Recent reports have described inherent problems with androgen immunoassays compared with mass spectrometry analyses. METHODS:We developed a method for measuring serum testosterone (T) and 5alpha-dihydrotestosterone (DHT) simultaneously via liquid-liquid extraction followed by liquid chromatography-tandem ma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.103846

    authors: Shiraishi S,Lee PW,Leung A,Goh VH,Swerdloff RS,Wang C

    更新日期:2008-11-01 00:00:00

  • Diagnosis and monitoring of hepatic injury. II. Recommendations for use of laboratory tests in screening, diagnosis, and monitoring.

    abstract:PURPOSE:To review information on the use of laboratory tests in screening, diagnosis, and monitoring of acute and chronic hepatic injury. DATA SOURCES AND STUDY SELECTION:A MEDLINE search was performed for key words related to hepatic diseases, including acute hepatitis, chronic hepatitis, alcoholic hepatitis, cirrhos...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Dufour DR,Lott JA,Nolte FS,Gretch DR,Koff RS,Seeff LB

    更新日期:2000-12-01 00:00:00

  • Analysis of the physicochemical state of C-reactive protein in different preparations including 2 certified reference materials.

    abstract:BACKGROUND:Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.147124

    authors: Rzychon M,Zegers I,Schimmel H

    更新日期:2010-09-01 00:00:00

  • Quantification of urinary porphyrins by liquid chromatography after oxidation of porphyrinogens.

    abstract::A quantitative "high-performance" liquid-chromatographic method is described for determining porphyrins in human urine. Porphyrinogens in urine are first converted to the corresponding porphyrins by oxidation with iodine. Uroporphyrin, hepatacarboxylic acid porphyrin, hexacarboxylic acid porphyrin, pentacarboxylic aci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe K,Konaka R

    更新日期:1989-08-01 00:00:00

  • Monitoring the stability of wavelength calibration of spectrophotometers.

    abstract::The difference in absorbance (delta A) between equimolar acid and alkaline solutions of methyl red, at a wavelength near the isosbestic point of the indicator, is reproducible. Furthermore, this delta A is sensitive to changes in the wavelength calibration of the instrument used to make the measurement. The delta A of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Korzun WJ,Miller WG

    更新日期:1986-01-01 00:00:00

  • Completeness of Reporting of Systematic Reviews of Diagnostic Test Accuracy Based on the PRISMA-DTA Reporting Guideline.

    abstract:BACKGROUND:We evaluated the completeness of reporting of diagnostic test accuracy (DTA) systematic reviews using the recently developed Preferred Reporting Items for Systematic Reviews and MetaAnalyses (PRISMA)-DTA guidelines. METHODS:MEDLINE® was searched for DTA systematic reviews published October 2017 to January 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2018.292987

    authors: Salameh JP,McInnes MDF,Moher D,Thombs BD,McGrath TA,Frank R,Dehmoobad Sharifabadi A,Kraaijpoel N,Levis B,Bossuyt PM

    更新日期:2019-02-01 00:00:00

  • Serum ionized calcium and corrected total calcium in borderline hyperparathyroidism.

    abstract::We studied 25 borderline-hyperparathyroidism patients whose total serum calcium concentration was within normal limits (reference range: 2.25--2.75 mmol/liter) but whose concentrations of serum ionized calcium were above normal (reference range: 1.03--1.23 mmol/liter). Their hyperparathyroidism was histopathologically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Larsson L,Ohman S

    更新日期:1978-11-01 00:00:00

  • Polyacrylamide gel electrophoresis in quantification of high-density lipoprotein cholesterol.

    abstract::We evaluated a method for quantifying high-density lipoprotein cholesterol in plasma, based on electrophoretic migration of the prestained (with Sudan Black III) sample through a discontinuous polyacrylamide++ gel and densitometric integration of the stain associated with each class of lipoprotein. With this method, o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Roche D,Atger V,Le Quang NT,Girard A,Ekindjian OG

    更新日期:1985-11-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Quantitative homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine.

    abstract::We describe specific EMIT homogeneous enzyme immunoassays for amitriptyline, nortriptyline, imipramine, and desipramine in patients' serum samples. Before analysis, an easily performed extraction step involving the use of 500 microL of sample and a 1-mL disposable column eliminates cross-reacting polar metabolites. Th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pankey S,Collins C,Jaklitsch A,Izutsu A,Hu M,Pirio M,Singh P

    更新日期:1986-05-01 00:00:00

  • Endotoxin binding to platelets in blood from patients with a sepsis syndrome.

    abstract::Endotoxin, the lipopolysaccharide cell wall constituent of Gram-negative bacteria, produces symptoms of the Gram-negative sepsis syndrome. By measuring endotoxin in blood from septic patients it may be possible to select a subpopulation of patients in which mortality can be prevented by treatment with anti-endotoxin a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Salden HJ,Bas BM

    更新日期:1994-08-01 00:00:00

  • Determination of quinidine by high-performance liquid chromatography.

    abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Powers JL,Sadee W

    更新日期:1978-02-01 00:00:00

  • Acyclic adenine nucleoside phosphonates in plasma determined by high-performance liquid chromatography with fluorescence detection.

    abstract::9-(2-Phosphonylmethoxyethyl)adenine (PMEA), (S)-9-(3-hydroxy-2-phosphonylmethoxypropyl)adenine (HPMPA), and (R,S)-9-(3-fluoro-2-phosphonylmethoxypropyl)adenine (FPMPA) are selective antiviral agents with activity against a broad spectrum of DNA viruses and retroviruses. A highly sensitive method has been developed to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Naesens L,Balzarini J,De Clercq E

    更新日期:1992-04-01 00:00:00

  • Screening for primary aldosteronism in essential hypertension: diagnostic accuracy of the ratio of plasma aldosterone concentration to plasma renin activity.

    abstract:BACKGROUND:The ratio of plasma aldosterone concentration to plasma renin activity (PRA) is considered the screening test of choice for primary aldosteronism. Uncertainty exists, however, regarding its diagnostic accuracy and the effects of antihypertensive drugs and dietary sodium balance on test characteristics. METH...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2004.041780

    authors: Schwartz GL,Turner ST

    更新日期:2005-02-01 00:00:00

  • Immunoluminometric assay for measurement of the C-terminal endothelin-1 precursor fragment in human plasma.

    abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065581

    authors: Papassotiriou J,Morgenthaler NG,Struck J,Alonso C,Bergmann A

    更新日期:2006-06-01 00:00:00

  • Amniotic fluid acetylcholinesterase activity and alpha-fetoprotein in chromosomal anomalies and neural tube defects.

    abstract::Measurement of alpha-fetoprotein concentration and acetylcholinesterase activity in amniotic fluid can be used to identify chromosomal defects as well as neural tube defects. In seven cases of trisomy 21 and one case of partial trisomy 3, alpha-fetoprotein concentrations were below the reference range but values for a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buamah PK,Skillen AW,Harrison J,Davison V

    更新日期:1985-04-01 00:00:00

  • Direct solid-phase time-resolved immunofluorometric assay of cortisol in serum.

    abstract::A dissociation-enhanced lanthanide fluoroimmunoassay of serum cortisol based on time-resolved fluorescence is described. The assay is a direct assay, where cortisol immobilized on the wall of a microtiter-strip well competes with cortisol in the sample for the europium-labeled polyclonal antibody. The amount of bound ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eskola JU,Näntö V,Meurling L,Lövgren TN

    更新日期:1985-10-01 00:00:00