Production of murine hybrid-hybridomas secreting bispecific monoclonal antibodies for use in urease-based immunoassays.

Abstract:

:To produce bispecific antibodies (BiAbs) for enzyme immunoassay (EIA) to replace antibody-enzyme conjugates, we developed a panel of 8-azaguanine/ouabain-resistant anti-urease variant hybridoma cell lines for use in hybridoma-hybridoma fusions. These variants represent mouse immunoglobulin subclasses IgM, IgG1, IgG2a, and IgG2b and have growth rates equal to those of the parental hybridomas. We fused an anti-urease-secreting variant hybridoma with an anti-human choriogonadotropin (hCG)-secreting hybridoma (both of IgG1 subclass) and selected the desired product with growth media containing hypoxanthine-aminopterin-thymidine (HAT) and ouabain. Over 95% of the resulting hybrids secreted anti-urease, and 60% of these secreted anti-hCG. The bispecific nature of secreted antibodies was demonstrated in a simultaneous EIA where BiAbs, hCG, and urease (EC 3.5.1.5) were incubated together in anti-hCG-coated microwells. As little as 25 int. units of hCG per liter could be reliably detected, which is equivalent to that for antibody-enzyme conjugates in EIA.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Takahashi M,Fuller SA

subject

Has Abstract

pub_date

1988-09-01 00:00:00

pages

1693-6

issue

9

eissn

0009-9147

issn

1530-8561

journal_volume

34

pub_type

杂志文章
  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • Commutability of a Whole-Blood External Quality Assessment Material for Point-of-Care C-Reactive Protein, Glucose, and Hemoglobin Testing.

    abstract:BACKGROUND:The optimal situation in external quality assessment (EQA) is to use commutable materials. No previous study has examined the commutability of a whole-blood material for point-of-care (POC) testing. The aim of this study was to determine the commutability of the Norwegian Quality Improvement of Laboratory Ex...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.300202

    authors: Bukve T,Sandberg S,Vie WS,Sølvik U,Christensen NG,Stavelin A

    更新日期:2019-06-01 00:00:00

  • Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots.

    abstract::We have assessed the technical performance and robustness of NycoCard CRP Whole Blood, a near-patient test for C-reactive protein (CRP), when used in realistic daily routine situations in general practice clinics (GPC). Thirteen GPCs participated, five of them with technician staff. From 898 patients, split-sample mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dahler-Eriksen BS,Lassen JF,Petersen PH,Lund ED,Lauritzen T,Brandslund I

    更新日期:1997-11-01 00:00:00

  • Inhibition of Na,K-ATPase by oleandrin and oleandrigenin, and their detection by digoxin immunoassays.

    abstract::Ingestion of oleander plant, containing the cardiac glycoside oleandrin, has been reported to induce fatal poisonings. Derivatives of oleandrin are structurally similar to digoxin. We investigated the cross-reactivities of oleandrin and its aglycone metabolite, oleandrigenin, in several commercially available digoxin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jortani SA,Helm RA,Valdes R Jr

    更新日期:1996-10-01 00:00:00

  • Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: two techniques evaluated and modified for improved performance.

    abstract::We evaluated the EMIT (enzyme-multiplied immuno technique) and FPIA (fluorescence polarization immunoassay) urine screening systems for detection of benzodiazepine intake. Healthy male volunteers were given single oral therapeutic doses of alprazolam (2 mg), chlordiazepoxide (25 mg), flunitrazepam (1 mg), lorazepam (3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Beck O,Lafolie P,Hjemdahl P,Borg S,Odelius G,Wirbing P

    更新日期:1992-02-01 00:00:00

  • Single-spin density-gradient ultracentrifugation vs gradient gel electrophoresis: two methods for detecting low-density-lipoprotein heterogeneity compared.

    abstract::Single-spin density-gradient ultracentrifugation (DUC) has proven to be a reproducible method for detection of low-density-lipoprotein (LDL) heterogeneity. Recently another method has been described for this: gradient gel electrophoresis (GGE) of serum, a method that might be more suitable for screening. To gain insig...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dormans TP,Swinkels DW,de Graaf J,Hendriks JC,Stalenhoef AF,Demacker PN

    更新日期:1991-06-01 00:00:00

  • Improved column method for separating lactate dehydrogenase isoenzymes 1 and 2.

    abstract::Lactate dehydrogenase (LD) isoenzymes 1 and 2 in human serum were separated on a column of diethylaminoethyl-Sephadex. Samples layered on mini-columns were eluted with buffered sodium chloride (100, 150, and 200 mmol/liter). Lactate dehydrogenase activity in column effluents was measured by the Wacker method, and thei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mercer DW

    更新日期:1978-03-01 00:00:00

  • Cardiac troponins I and T in patients with suspected acute coronary syndrome: a comparative study in a routine setting.

    abstract::We compared cardiac troponin I (cTnI), using Access, Sanofi Pasteur, and cardiac troponin T (cTnT), using Elecsys, Boehringer Mannheim, in the first two routine blood samplings in a routine panel of cardiac markers for the biochemical diagnostic evaluation of patients with symptoms of acute myocardial infarction (AMI)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hetland O,Dickstein K

    更新日期:1998-07-01 00:00:00

  • Thyroxine, thyrotropin, and age in a euthyroid hospital patient population.

    abstract::The diagnosis of thyroid disease now often can be achieved reliably by measuring thyrotropin (TSH) alone. Thyroxine (T4), triiodothyronine, and other analytes are only needed if TSH and the accompanying clinical condition are discordant. We describe here work that confirms the age independence of TSH in both inpatient...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davey R

    更新日期:1997-11-01 00:00:00

  • Lipoprotein(a) and cardiovascular disease in ethnic Chinese: the Chin-Shan Community Cardiovascular Cohort Study.

    abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.090969

    authors: Chien KL,Hsu HC,Su TC,Sung FC,Chen MF,Lee YT

    更新日期:2008-02-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range.

    abstract:BACKGROUND:Cyclosporin A (CsA) is commonly measured by immunoassay techniques that have a limited analytical range. The consequence of this is that low CsA concentrations that may be clinically significant are difficult to measure and that high concentrations require sample dilution, which introduces error and increase...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Keevil BG,Tierney DP,Cooper DP,Morris MR

    更新日期:2002-01-01 00:00:00

  • Detection of Colorectal Cancer in Circulating Cell-Free DNA by Methylated CpG Tandem Amplification and Sequencing.

    abstract:BACKGROUND:Aberrant DNA hypermethylation of CpG islands occurs frequently throughout the genome in human colorectal cancer (CRC). A genome-wide DNA hypermethylation analysis technique using circulating cell-free DNA (cfDNA) is attractive for the noninvasive early detection of CRC and discrimination between CRC and othe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2019.301804

    authors: Li J,Zhou X,Liu X,Ren J,Wang J,Wang W,Zheng Y,Shi X,Sun T,Li Z,Kang A,Tang F,Wen L,Fu W

    更新日期:2019-07-01 00:00:00

  • Low apparent creatine kinase activity and prolonged lag phases in serum of patients with metastatic disease: elimination by treatment of sera with sulfhydryl agents.

    abstract::We find lag phases exceeding 20 min in measuring creatine kinase activity, by using the kinetic creatin phosphate leads to creatine assay, in sera of some patients with carcinoma metastatic to the liver. Such long lag phases are accompanied by a decreased apparent enzyme activity. These problems are eliminated by addi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Morgan WS,Davis JE,Ladenson JH

    更新日期:1976-11-01 00:00:00

  • A case of sulfhemoglobinemia and emergency measurement of sulfhemoglobin with an OSM3 CO-oximeter.

    abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu C,Kenny MA

    更新日期:1997-01-01 00:00:00

  • Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    abstract:BACKGROUND:In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.067116

    authors: Sauvage FL,Saint-Marcoux F,Duretz B,Deporte D,Lachatre G,Marquet P

    更新日期:2006-09-01 00:00:00

  • Detection of a soluble form of BACE-1 in human cerebrospinal fluid by a sensitive activity assay.

    abstract:BACKGROUND:Formation of deposits of the insoluble amyloid beta-peptide is believed to be causally related with neurodegeneration in Alzheimer disease (AD). The beta-peptide originates from a larger amyloid precursor protein (APP) by the action of proteolytic enzymes. The first proteolytic event leading to amyloid forma...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.066720

    authors: Verheijen JH,Huisman LG,van Lent N,Neumann U,Paganetti P,Hack CE,Bouwman F,Lindeman J,Bollen EL,Hanemaaijer R

    更新日期:2006-06-01 00:00:00

  • Distinguishing Intake of New Synthetic Cannabinoids ADB-PINACA and 5F-ADB-PINACA with Human Hepatocyte Metabolites and High-Resolution Mass Spectrometry.

    abstract:BACKGROUND:ADB-PINACA and its 5-fluoropentyl analog 5F-ADB-PINACA are among the most potent synthetic cannabinoids tested to date, with several severe intoxication cases. ADB-PINACA and 5F-ADB-PINACA have a different legal status, depending on the country. Synthetic cannabinoid metabolites predominate in urine, making ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.267575

    authors: Carlier J,Diao X,Scheidweiler KB,Huestis MA

    更新日期:2017-05-01 00:00:00

  • Apolipoprotein B and A-I values in 147576 Swedish males and females, standardized according to the World Health Organization-International Federation of Clinical Chemistry First International Reference Materials.

    abstract::Serum concentrations of apolipoprotein (apo) B and apo A-I were measured from 1985-1996 in a Swedish population sample of 83 112 males and 64 464 females, ages <20 to >80 years, using an automated immunoturbidimetric method calibrated against fresh pools of human serum and commercial calibrators. All values were recal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jungner I,Marcovina SM,Walldius G,Holme I,Kolar W,Steiner E

    更新日期:1998-08-01 00:00:00

  • Comparison of two micromethods for determination of lipoprotein cholesterol in plasma.

    abstract::We compared the results obtained by a micromethod for the determination of plasma lipoprotein cholesterol, in which electrophoresis is used to separate the lipoprotein fractions (beta-, pre-beta-, and alpha-lipoproteins), with those determinations with ultracentrifugation (low-density, very-low-density, and high-densi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kupke IR,Zeugner S,Gottschalk A

    更新日期:1979-10-01 00:00:00

  • A tandem mass spectrometry triplex assay for the detection of Fabry, Pompe, and mucopolysaccharidosis-I (Hurler).

    abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.152009

    authors: Duffey TA,Bellamy G,Elliott S,Fox AC,Glass M,Turecek F,Gelb MH,Scott CR

    更新日期:2010-12-01 00:00:00

  • Immunopeptidometric assay for enzymatically active prostate-specific antigen.

    abstract:BACKGROUND:Determinations of certain forms of prostate-specific antigen (PSA) have been shown to increase the specificity for prostate cancer (PCa). One such variant, proteolytically active PSA, is a potentially useful tumor marker, but it is not specifically recognized by antibodies. Using phage display libraries, we ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026146

    authors: Wu P,Zhu L,Stenman UH,Leinonen J

    更新日期:2004-01-01 00:00:00

  • Use of two reporter dyes without interference in a single-tube rapid-cycle PCR: alpha(1)-antitrypsin genotyping by multiplex real-time fluorescence PCR with the LightCycler.

    abstract:BACKGROUND:alpha(1)-Antitrypsin is the major plasma serine protease inhibitor. Its deficiency is mainly associated with the alleles PI*S and PI*Z and can lead to obstructive lung disease in adults and to liver cirrhosis during childhood. METHODS:A multiplex PCR method has been established that uses two sets of primers...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Oellerich M,Schütz E

    更新日期:2000-02-01 00:00:00

  • Transferability studies for the AACC reference method and the IFCC method for measurement of alkaline phosphatase activity.

    abstract::We present the results of measurements of alkaline phosphatase activity from interlaboratory transferability studies conducted by 12 laboratories in five countries. The variability, as demonstrated by within-day precision (CV less than or equal to 2.6%), between-day precision (CV less than or equal to 3.6%), and betwe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tietz NW,Rinker AD,Burtis C,Duncan P,Ervin K,Ewen L,Hørder M,Mathieu M,Petitclerc C,Grisley D

    更新日期:1984-05-01 00:00:00

  • Do enzymatic analyses of serum triglycerides really need blanking for free glycerol?

    abstract::Distributions of concentrations of free glycerol in clinical plasma obtained for triglyceride assay were compiled to determine the frequency with which increased concentrations of free glycerol posed a potential problem for clinical interpretation of triglyceride results. Clinical histories were studied in patients wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jessen RH,Dass CJ,Eckfeldt JH

    更新日期:1990-07-01 00:00:00

  • Use of the laboratory in prediction of outcome in the high-risk newborn.

    abstract::This paper reviews our ability to predict survival and neurodevelopmental outcome in the newborn period. Traditionally, prognosis is based on individual risk factors or disease states. The laboratory plays an important role in diagnosing some of these. For example, prenatal and newborn screening are important in the d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Synnes AR

    更新日期:1997-01-01 00:00:00

  • Quantifying spurious free T4 results attributable to thyroxine-binding proteins in serum dialysates and ultrafiltrates.

    abstract:BACKGROUND:Direct equilibrium dialysis and direct ultrafiltration free thyroxine (T(4)) assays rely on semipermeable membranes to exclude T(4)-binding serum proteins from dialysates and ultrafiltrates. The presence of these proteins in dialysates or ultrafiltrates will yield spuriously high free T(4) values when free T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.085316

    authors: Fritz KS,Wilcox RB,Nelson JC

    更新日期:2007-05-01 00:00:00

  • Lactate measured in diluted and undiluted whole blood and plasma: comparison of methods and effect of hematocrit.

    abstract::We evaluated a new analyzer that measures lactate in undiluted whole blood by direct (or undiluted) amperometry [Nova Stat Profile 7 Analyzer (SP7); Nova Biomedical, Waltham, MA] by comparing it with two other analyzers, one for measuring lactate in whole blood by indirect (or diluted) amperometry [Model 2300; Yellow ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Hammes ME,Gray R,Lineberry B,Abrams B

    更新日期:1992-12-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

    abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cohen A,Hertz HS,Mandel J,Paule RC,Schaffer R,Sniegoski LT,Sun T,Welch MJ,White E 5th

    更新日期:1980-06-01 00:00:00