Abstract:
:This case demonstrates the importance of monitoring theophylline concentrations in serum during therapy with this drug. The commonly used body-weight-derived guidelines for therapeutic dose are not adequate and do not preclude the necessity for such monitoring. The ultraviolet spectrophotometric methods available for serum theophylline analysis are generally suitable; however, the more specific liquid-chromatographic techniques have certain advantages in that they require only small amounts of serum (25--50 microliter) and are relatively free of interferences from other commonly used drugs. The enzyme immunoassay procedure also appears well suited for the routine measurement of theophylline. The therapeutic range for serum theophylline is well established (10--20 mg/liter) and theophylline values correlate well with therapeutic response and toxicity. We therefore recommend that theophylline in the serum be monitored regularly and dosages adjusted accordingly.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
subject
Has Abstractpub_date
1978-09-01 00:00:00pages
1603-8issue
9eissn
0009-9147issn
1530-8561journal_volume
24pub_type
杂志文章abstract:BACKGROUND:Paraoxonase may protect lipoproteins and cell membranes from peroxidation, and alterations in the activity of this enzyme have been associated with some chronic diseases. Serum paraoxonase appears to be mainly under genetic control, but some studies suggest that environmental factors may also modulate its ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.9.1491
更新日期:2003-09-01 00:00:00
abstract::To assess the distribution of serum concentrations of the atherogenic lipoprotein(a) [Lp(a)] in an obese population and the possible effects of weight reduction, we determined Lp(a) in 52 white, moderately obese subjects (16 men and 36 women). The subjects were participating in a weight-reduction program of diet, exer...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1991-07-01 00:00:00
abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-08-01 00:00:00
abstract::The immunoreactivity of anti-triiodothyronine (anti-T3) IgG, pretreated at acidic pH and adsorbed onto polystyrene beads, was significantly greater than that determined for native anti-T3 IgG immobilized at optimum pH 3.5. Acidic-pH-pretreated IgG, adsorbed at pH 7.0 onto ethanol-treated beads, had less immunoreactivi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-03-01 00:00:00
abstract::We compared results obtained from two parathyrin (parathyroid hormone) assays with differing specificities, using sera from 172 normal donors and from 98 patients with disorders of calcium regulation. Intact parathyrin was measured in both assays; the C-parathyrin assay also measured the 53-84 amino acid C-terminal ho...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-11-01 00:00:00
abstract:BACKGROUND:Blockade of the renin-angiotensin system (RAS) represents a main strategy in the therapy of heart failure with reduced ejection fraction (HFrEF), but the role of active renin concentration (ARC) for guiding therapy in the presence of an RAS blockade remains to be established. This study assessed angiotensin ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.278705
更新日期:2018-03-01 00:00:00
abstract:BACKGROUND:Formation of deposits of the insoluble amyloid beta-peptide is believed to be causally related with neurodegeneration in Alzheimer disease (AD). The beta-peptide originates from a larger amyloid precursor protein (APP) by the action of proteolytic enzymes. The first proteolytic event leading to amyloid forma...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.066720
更新日期:2006-06-01 00:00:00
abstract::We investigated two techniques of immunoblotting--the Western blot and the dot blot--for use in detecting prostatic acid phosphatase (PAP, EC 3.1.3.2). We used polyclonal antisera to human PAP, produced in rabbits by hyperimmunization with purified PAP, and PAP-specific monoclonal antibodies in the immunoenzymatic pro...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-10-01 00:00:00
abstract:BACKGROUND:The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS:We tested 18 specimens after centrifuga...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.6.935
更新日期:2003-06-01 00:00:00
abstract::A new sandwich-type enzyme-linked immunosorbent assay for quantifying glycocalicin, a proteolytic fragment of platelet membrane glycoprotein Ib, is described. The assay is based on the use of two monoclonal antibodies raised against glycoprotein Ib and involves the avidin-biotin technique. The detection limit is 7 mic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-02-01 00:00:00
abstract::We measured the cross reactivity of two medications--digitoxin and spironolactone--in two digoxin radioimmunoassay (liquid and solid-phase) kit procedures. Both tests showed similar average percentages of cross reactivity with digitoxin (7.2 and 8.9% for intravenous, and 11.9 and 10.9% for oral administration), but no...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-04-01 00:00:00
abstract:BACKGROUND:Group B streptococcal infections are the leading cause of sepsis and meningitis in newborns. A rapid and reliable method for the detection of this pathogen at the time of delivery is needed for the early treatment of neonates. Isothermal amplification techniques such as recombinase polymerase amplification h...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.213504
更新日期:2014-04-01 00:00:00
abstract::We describe a procedure for measuring dialyzable calcium in 60 sera per hour with use of AutoAnalyzer (Technicon) modules. The serum is buffered, then dialyzed in a regular 6-inch (15-cm) dialysis block. A constant proportion of the dialyzable calcium is fluorometrically measured. Analysis of samples containing protei...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-07-01 00:00:00
abstract::We report a case of hyperphosphatasemia in a 35-year-old patient with hepatitis B who underwent an orthotopic xenogeneic liver transplant. Marked increases in total alkaline phosphatase (ALP; EC 3.1.3.1) activity began 5 days posttransplantation (six times human normal) and increased to approximately 17 times normal a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract::In this simple and low-cost radioimmunoassay (RIA) procedure for thyroxin (T4), ethacridine (6,9-diamino-2-ethoxyacridine lactate; Rivanol) is used to separate antibody-bound ligand and free ligand. This acridine dye precipitates free T4 not bound to antibody. At pH 8.6, it precipitates more than 90% of 125I-labeled T...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-11-01 00:00:00
abstract::Investigating the interference of danazol in testosterone radioimmunoassays, we measured serum testosterone concentrations in the serum of women receiving danazol, with three testosterone radioimmunoassay kits. All of these showed positive interference by danazol or its metabolites (or both). Values for testosterone o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract:BACKGROUND:Near-infrared spectroscopy is proposed as a method for providing real-time urea concentrations during hemodialysis treatments. The feasibility of such noninvasive urea measurements is evaluated in undiluted dialysate fluid. METHODS:Near-infrared spectra were collected from calibration solutions of urea prep...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2001-01-01 00:00:00
abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-11-01 00:00:00
abstract::We have designed a re-usable dialysis cell and a complex dialysis buffer, with which undiluted serum samples can be dialyzed with minimal changes in their serum matrix. Dialysate thyroxin (free T4) is then measured by a sensitive RIA for T4. The range of reportability was 2-128 ng/L, the normal range was 8-27 ng/L, an...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-09-01 00:00:00
abstract::We evaluated the analytical performance of Trinder's glucose oxidase (EC 1.1.3.4)/peroxidase (EC 1.11.1.7) 4-aminophenazone-phenol method for the quantification of serum glucose as adapted to the Technicon SMAC. Our results correlated well with those by the routine SMAC glucose oxidase/peroxidase 3-methyl-2-benzothiaz...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-10-01 00:00:00
abstract:BACKGROUND:The fibroblast growth factor (FGF) and FGF receptor (FGFR) axis plays a critical role in tumorigenesis, but little is known of its influence in ovarian cancer. We sought to determine the association of genetic variants in the FGF pathway with risk, therapeutic response, and survival of patients with ovarian ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.211490
更新日期:2014-01-01 00:00:00
abstract::A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fra...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-08-01 00:00:00
abstract::We compared the activities of thyroid-stimulating antibodies (TSAb) measured in cultures of human thyrocytes and the values for thyrotropin-receptor antibodies (TRAb) as measured with a commercial kit based on use of radiolabeled receptors. Sera were obtained from patients with Graves' disease before, during, and afte...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-07-01 00:00:00
abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-04-01 00:00:00
abstract::Ethchlorvynol is a commonly abused sedative hypnotic. I report here a seven-day study of serum ethchlorvynol concentrations in a patient who had received an extreme overdose. These concentrations were correlated with the patient's response to stimuli. Serum ethchlorvynol concentrations were logarithmically related to ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-06-01 00:00:00
abstract:BACKGROUND:Quantitative PCR of viral nucleic acids can be useful clinically in diagnosis, risk assessment, and monitoring of antiviral therapy. We wished to develop a chemiluminescence competitive PCR (cPCR) for parvovirus B19. METHODS:Parvovirus DNA target sequences and competitor sequences were coamplified and direc...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-09-01 00:00:00
abstract:BACKGROUND:The current diagnosis and monitoring of bladder cancer are heavily reliant on cystoscopy, an invasive and costly procedure. Previous efforts in urine-based detection of bladder cancer focused on targeted approaches that are predicated on the tumor expressing specific aberrations. We aimed to noninvasively de...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.301341
更新日期:2019-07-01 00:00:00
abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-08-01 00:00:00
abstract::Autocorrelation of clinical chemistry quality-control (Q/C) measurements causes one of the basic assumptions underlying the use of Levey-Jennings control charts to be violated and performance to be degraded. This is the requirement that the observations be statistically independent. We present a proposal for a new app...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-07-01 00:00:00
abstract:BACKGROUND:For the past 30 years, the Sanger method has been the dominant approach and gold standard for DNA sequencing. The commercial launch of the first massively parallel pyrosequencing platform in 2005 ushered in the new era of high-throughput genomic analysis now referred to as next-generation sequencing (NGS). ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2008.112789
更新日期:2009-04-01 00:00:00