Effect of weight loss on serum lipoprotein(a) concentrations in an obese population.

Abstract:

:To assess the distribution of serum concentrations of the atherogenic lipoprotein(a) [Lp(a)] in an obese population and the possible effects of weight reduction, we determined Lp(a) in 52 white, moderately obese subjects (16 men and 36 women). The subjects were participating in a weight-reduction program of diet, exercise, and behavior modification plus combination anorectic drug therapy (fenfluramine and phentermine). This placebo-controlled, double-blind study lasted 104 weeks. We also determined concentrations of fasting insulin, triglycerides, total cholesterol, high-density lipoprotein cholesterol, apolipoprotein (apo) A-I, low-density lipoprotein cholesterol, and apo B. Results showed the following: a highly skewed, nongaussian distribution of serum Lp(a) values in the obese population, virtually identical to that reported for healthy adults; no clinically significant change in Lp(a) concentrations with weight loss; and further evidence of normalization of insulin, lipid, and lipoprotein concentrations with weight loss.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Corsetti JP,Sterry JA,Sparks JD,Sparks CE,Weintraub M

subject

Has Abstract

pub_date

1991-07-01 00:00:00

pages

1191-5

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

37

pub_type

临床试验,杂志文章
  • Column affinity chromatography for bound/free separation in ligand assays. I. Radioimmunoassay of choriomammotropin (human placental lactogen).

    abstract::A method is described for separating antibody-bound from free fractions in ligand assays by column affinity chromatography, and its application to radioimmunoassay of choriomammotropin. In the method, 70 x 10 mm (i.d.) polypropylene columns containing about 150 mg of immunosorbent (goat anti-rabbit gamma-globulins cov...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cornale P,Bonazzi M,Multinu C,Romelli P,Vancheri L,Pennisi F

    更新日期:1981-06-01 00:00:00

  • Toward Worldwide Hepcidin Assay Harmonization: Identification of a Commutable Secondary Reference Material.

    abstract:BACKGROUND:Absolute plasma hepcidin concentrations measured by various procedures differ substantially, complicating interpretation of results and rendering reference intervals method dependent. We investigated the degree of equivalence achievable by harmonization and the identification of a commutable secondary refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.256768

    authors: van der Vorm LN,Hendriks JC,Laarakkers CM,Klaver S,Armitage AE,Bamberg A,Geurts-Moespot AJ,Girelli D,Herkert M,Itkonen O,Konrad RJ,Tomosugi N,Westerman M,Bansal SS,Campostrini N,Drakesmith H,Fillet M,Olbina G,Pasricha

    更新日期:2016-07-01 00:00:00

  • Simultaneous assay of corticosterone and cortisol in plasma by reversed-phase liquid chromatography.

    abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hariharan M,Naga S,VanNoord T,Kindt EK

    更新日期:1992-03-01 00:00:00

  • Multianalyte microspot immunoassay--microanalytical "compact disk" of the future.

    abstract::Throughout the 1970s, controversy centered both on immunoassay "sensitivity" per se and on the relative sensitivities of labeled antibody (Ab) and labeled analyte methods. Our theoretical studies revealed that RIA sensitivities could be surpassed only by the use of very high-specificity nonisotopic labels in "noncompe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ekins RP,Chu FW

    更新日期:1991-11-01 00:00:00

  • Washington University Case Conference: Theophylline toxicity.

    abstract::This case demonstrates the importance of monitoring theophylline concentrations in serum during therapy with this drug. The commonly used body-weight-derived guidelines for therapeutic dose are not adequate and do not preclude the necessity for such monitoring. The ultraviolet spectrophotometric methods available for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors:

    更新日期:1978-09-01 00:00:00

  • Association of changes in oxidative and proinflammatory states with changes in vascular function after a lifestyle modification trial among obese children.

    abstract:BACKGROUND:The association of changes in oxidative and proinflammatory states with vascular function after diet and exercise intervention among obese children has not been previously explored. METHODS:In this 6-week diet and exercise intervention study in 35 obese children, age 12 to 18 years, we evaluated the relatio...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2007.089953

    authors: Kelishadi R,Hashemi M,Mohammadifard N,Asgary S,Khavarian N

    更新日期:2008-01-01 00:00:00

  • Immunopeptidometric assay for enzymatically active prostate-specific antigen.

    abstract:BACKGROUND:Determinations of certain forms of prostate-specific antigen (PSA) have been shown to increase the specificity for prostate cancer (PCa). One such variant, proteolytically active PSA, is a potentially useful tumor marker, but it is not specifically recognized by antibodies. Using phage display libraries, we ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026146

    authors: Wu P,Zhu L,Stenman UH,Leinonen J

    更新日期:2004-01-01 00:00:00

  • Distribution of CII and CIII peptides in lipoprotein classes: methods and clinical significance.

    abstract::We describe a method for measuring apolipoprotein (apo) C distribution between apo B-containing lipoprotein (apo B-LP) and non-apo B-LP. The procedure requires the precipitation of apo B-LP, the redissolution of the pellet, and the quantification of C peptides in the redissolved pellet. The ratio of apo C in non-apo B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graziani MS,Zanolla L,Righetti G,Marchetti C,Zanotto G,Lupo A

    更新日期:1994-02-01 00:00:00

  • Addition of triglyceride to serum for use in quality control and reference.

    abstract::We describe a simple method in which a water-soluble mixture of triocatanoin and a surfactant, "Triton X-114," are used in preparing solutions of triglycerides (triacylglycerols) in either human serum, solutions of albumin, or water. Analytical recovery added triglyceride was quantitative by two methods. The addition ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bonderman DP,Proksch GJ,Bonderman PW

    更新日期:1976-08-01 00:00:00

  • Capillary electrophoresis for detection of inherited disorders of purine and pyrimidine metabolism.

    abstract:BACKGROUND:Measurement of purine and pyrimidine metabolites presents complex problems for separations currently performed by HPLC and thin-layer chromatography in clinical practice. We developed a novel capillary electrophoresis method for this purpose. METHODS:Separations were performed in 60 mmol/L borate-2-amino-2-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adam T,Friedecký D,Fairbanks LD,Sevcík J,Barták P

    更新日期:1999-12-01 00:00:00

  • Subclass typing of IgG paraproteins by immunofixation electrophoresis.

    abstract::We present a simple method for subclass typing of IgG paraproteins, with which we have demonstrated a large number of paraproteins that were undetected by conventional immunofixation techniques. The types and distribution of IgG subclass paraproteins were analyzed in 92 human sera in which IgG paraproteins had been de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klouche M,Bradwell AR,Wilhelm D,Kirchner H

    更新日期:1995-10-01 00:00:00

  • Rapid single-tube screening of the C282Y hemochromatosis mutation by real-time multiplex allele-specific PCR without fluorescent probes.

    abstract:BACKGROUND:An accurate determination of the major HFE mutation (C282Y), which is associated with hereditary hemochromatosis, is important in diagnosis and risk assessment for this disease. We report a single-tube high-throughput PCR method for the detection of C282Y. METHODS:We combined three previously described prin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Donohoe GG,Laaksonen M,Pulkki K,Rönnemaa T,Kairisto V

    更新日期:2000-10-01 00:00:00

  • Use of neural networks to diagnose acute myocardial infarction. II. A clinical application.

    abstract::We investigated the ability of neural networks to diagnose acute myocardial infarction (AMI) from laboratory data only. Several networks were trained with different combinations of data obtained at admission and within the first 12 h and 24 h after admission. The data used included the electrocardiogram (ECG) and the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pedersen SM,Jørgensen JS,Pedersen JB

    更新日期:1996-04-01 00:00:00

  • Analysis for platinum in biological material by flameless atomic absorption spectrometry.

    abstract::A method for determining platinum in biological materials by flameless atomic absorption spectrometry has been developed for use in pharmacological studies of platinum antitumor compounds. Tissue digests are analyzed in a heated graphite atomizer, with use of background correction and ramp temperature charring. We hav...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pera MF Jr,Harder HC

    更新日期:1977-07-01 00:00:00

  • Thin film biosensor for rapid visual detection of nucleic acid targets.

    abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ostroff RM,Hopkins D,Haeberli AB,Baouchi W,Polisky B

    更新日期:1999-09-01 00:00:00

  • Mitochondrial aspartate aminotransferase determined by "Fast Protein Liquid Chromatography".

    abstract::We describe an improved separation of the isoenzymes of aspartate aminotransferase (EC 2.6.1.1), based on ion-exchange chromatography. Involving the "Fast Protein Liquid Chromatography" system (Pharmacia) with a MonoQ column, this rapid, reproducible method for quantifying the mitochondrial enzyme shows good resolutio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Grøstad M,Rej R,Huseby NE

    更新日期:1990-02-01 00:00:00

  • Selection, preparation, and characterization of commutable frozen human serum pools as potential secondary reference materials for lipid and apolipoprotein measurements: study within the framework of the Dutch project "Calibration 2000".

    abstract:BACKGROUND:The Dutch project "Calibration 2000" aims at harmonization of laboratory results via calibration by development of matrix-based secondary reference materials. We considered the selection, preparation, and characterization of 34 potential reference materials (PRMs). METHODS:Sixteen PRMs were prepared either ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Cobbaert C,Weykamp C,Baadenhuijsen H,Kuypers A,Lindemans J,Jansen R

    更新日期:2002-09-01 00:00:00

  • Adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood compared for clinical evaluation of patients with disorders of calcium metabolism.

    abstract::We report results for adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood from 183 patients with disorders of calcium metabolism (primary hyperparathyroidism, secondary hyperparathyroidism of malabsorption, primary hypoparathyroidism, Paget's disease, acromegaly, hypercalc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thode J,Holmegaard SN,Transbøl I,Fogh-Andersen N,Siggaard-Andersen O

    更新日期:1990-03-01 00:00:00

  • Immunoluminometric assay for measurement of the C-terminal endothelin-1 precursor fragment in human plasma.

    abstract:BACKGROUND:Endothelin-1 (ET-1), a potent vasoconstrictor, is difficult to measure because of its instability and its binding to receptors and plasma proteins. We report a rapid, robust way to indirectly quantify ET-1 release by measuring the C-terminal ET-1 precursor fragment (CT-proET-1) without an extraction step. M...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065581

    authors: Papassotiriou J,Morgenthaler NG,Struck J,Alonso C,Bergmann A

    更新日期:2006-06-01 00:00:00

  • Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.

    abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ohkubo A,Kamei S,Yamanaka M,Arai F,Kitajima M,Kondo A

    更新日期:1981-07-01 00:00:00

  • Long-term aspirin and clopidogrel response evaluated by light transmission aggregometry, VerifyNow, and thrombelastography in patients undergoing percutaneous coronary intervention.

    abstract:BACKGROUND:A reduced response to aspirin and clopidogrel predicts ischemic events, but reliable tests are needed to identify low responders. We compared 3 platelet-function tests during long-term dual treatment with aspirin and clopidogrel. METHODS:Patients who underwent a percutaneous coronary intervention and were r...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.137471

    authors: Madsen EH,Saw J,Kristensen SR,Schmidt EB,Pittendreigh C,Maurer-Spurej E

    更新日期:2010-05-01 00:00:00

  • Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations.

    abstract::Creatinine and specific gravity (relative density) measurements both allow differences in urine concentration to be taken into account in determining urine cotinine concentrations. In this study we demonstrate that the variance of urine cotinine measurements is reduced comparably when either creatinine or specific gra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Haddow JE,Knight GJ,Palomaki GE,Neveux LM,Chilmonczyk BA

    更新日期:1994-04-01 00:00:00

  • Correlation of antemortem serum creatine kinase, creatine kinase-MB, troponin I, and troponin T with cardiac pathology.

    abstract:BACKGROUND:Spurious increases in serum troponins, especially troponin T, have been reported in patients with and without acute myocardial syndromes. METHODS:We studied 78 autopsied patients without clinical myocardial infarction (MI) and correlated histologic cardiac findings with antemortem serum creatine kinase (CK)...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ooi DS,Isotalo PA,Veinot JP

    更新日期:2000-03-01 00:00:00

  • Distribution and correlates of C-reactive protein concentrations among adult US women.

    abstract:BACKGROUND:Understanding the distribution of C-reactive protein (CRP) concentration among adult women in the US helps to establish the magnitude of women at increased risk for cardiovascular disease. METHODS:We examined the distribution and correlates of CRP, using data from 2205 women >or=20 years of age from the Nat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.027359

    authors: Ford ES,Giles WH,Mokdad AH,Myers GL

    更新日期:2004-03-01 00:00:00

  • Ion chromatography: a new technique for clinical chemistry.

    abstract::Ion chromatography is a new analytical technique in which the ions to be analyzed are separated on a special pellicular ion-exchange column. Once separated, the effluent from the separating column passes into a second ion-exchange column, which removes the eluent or buffer ions from the moving phase without removing t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anderson C

    更新日期:1976-09-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00

  • Microscale ultrafiltration technique for determining free drug in 50-microL serum samples.

    abstract::This ultrafiltration technique allows determination of free drug in 50 microL of serum. We ultrafiltered sera containing the following drugs--valproic acid (and its major metabolites), phenobarbital, diazepam, indomethacin, phenytoin, furosemide, and chloramphenicol--using both the commercially available micropartitio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wittfoht W,Duwe K,Kuhnz W,Nau H

    更新日期:1984-06-01 00:00:00

  • Combi scheme: new combined internal/external quality-assessment scheme in The Netherlands.

    abstract::The Dutch Foundation for Quality Assessment in Clinical Chemistry (SKZL) is the professional organization that conducts external quality-assessment schemes in The Netherlands. However, such schemes in fact assess the performance of the internal quality-control systems of the participating laboratories. In this paper w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steigstra H,Jansen RT,Baadenhuijsen H

    更新日期:1991-07-01 00:00:00

  • Three assays for glycohemoglobin compared.

    abstract::Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Turpeinen U,Karjalainen U,Stenman UH

    更新日期:1995-02-01 00:00:00

  • The clinical utility of high-sensitivity C-reactive protein in cardiovascular disease and the potential implication of JUPITER on current practice guidelines.

    abstract:BACKGROUND:High-sensitivity C-reactive protein (hsCRP) testing is relatively inexpensive and has been shown to predict the risk of cardiovascular disease (CVD) and diabetes in multiple patient groups, including those treated with statin therapy. JUPITER (Justification for the Use of Statins in Primary Prevention: An In...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.109728

    authors: Mora S,Musunuru K,Blumenthal RS

    更新日期:2009-02-01 00:00:00