Three assays for glycohemoglobin compared.

Abstract:

:Using 123 specimens, we compared the concordance of three different methods for determining glycohemoglobin (GHb): the Diamat (Bio-Rad Laboratories), an automated analyzer measuring HbA1c by cation-exchange chromatography; an assay with the IMx analyzer (Abbott Laboratories), based on boronate affinity binding; and an HPLC method measuring HbA1c by cation-exchange chromatography on a PolyCAT A column (PolyLC Inc.). The Pearson's correlation coefficient between PolyCAT A and Diamat was 0.900 +/- 0.038 (mean +/- 2 SD) and between PolyCAT A and IMx, 0.857 +/- 0.042. However, up to twofold differences were seen in some samples. The proportion of GHb was consistently lower with the PolyCAT A method than with the other two assays, apparently because of better separation of HbA1c from nonglycated coeluting forms of Hb. The difference in glycation percentage between the PolyCAT A and Diamat methods is 2-3% over the whole concentration range. These results point to the limitations of Diamat as a reference method to be used to calibrate other methods for determining HbA1c. Further, a switch from one method to another is likely to cause considerable problems in the clinical follow-up of certain patients.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Turpeinen U,Karjalainen U,Stenman UH

subject

Has Abstract

pub_date

1995-02-01 00:00:00

pages

191-5

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

41

pub_type

杂志文章
  • Beyond diagnostic accuracy: the clinical utility of diagnostic tests.

    abstract::Like any other medical technology or intervention, diagnostic tests should be thoroughly evaluated before their introduction into daily practice. Increasingly, decision makers, physicians, and other users of diagnostic tests request more than simple measures of a test's analytical or technical performance and diagnost...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2012.182576

    authors: Bossuyt PM,Reitsma JB,Linnet K,Moons KG

    更新日期:2012-12-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ

    更新日期:1994-06-01 00:00:00

  • Assessing the quality of glucose monitor studies: a critical evaluation of published reports.

    abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.083493

    authors: Mahoney J,Ellison J

    更新日期:2007-06-01 00:00:00

  • Benign inherited hyperphosphatasemia of intestinal origin: report of two cases and a brief review of the literature.

    abstract::Two families with benign hyperphosphatasemia of intestinal origin were studied and compared with six other cases reported in the literature. No evidence of clinical abnormalities or explanations for the unusual enzyme concentrations were found. Agarose gel electrophoresis of alkaline phosphatase (ALP, EC 3.1.3.1) isoe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Panteghini M

    更新日期:1991-08-01 00:00:00

  • A sensitive liquid-chromatographic method for determination of 3'-azido-3'-deoxythymidine (AZT) in plasma and urine.

    abstract::We describe a liquid-chromatographic assay for AZT in human plasma and urine. This assay involves the use of two internal standards, allowing reference of AZT peaks to the appropriate internal standard, the choice depending on the range of concentrations encountered. This method is isocratic, specific, sensitive enoug...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hedaya MA,Sawchuk RJ

    更新日期:1988-08-01 00:00:00

  • Erroneous results with routine laboratory testing for immunoglobulins due to interference from circulating immune complexes in a case of hyperviscosity syndrome associated with autoimmune disease.

    abstract::A patient with the hyperviscosity syndrome exhibited very high concentrations of intermediate to small circulating immune complexes (CIC), involving 40-50% of the IgG present, with IgG rheumatoid factor activity. We demonstrate that precipitation of CIC by polyethylene glycol in the reaction mixture caused interferenc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levinson SS,Perry M,Goldman J,Nathan LE

    更新日期:1988-04-01 00:00:00

  • Diagnostic value of plasma cystatin C as a glomerular filtration marker in decompensated liver cirrhosis.

    abstract:BACKGROUND:Plasma creatinine concentration and calculated creatinine clearance are of limited value as glomerular filtration rate (GFR) markers in patients with decompensated liver cirrhosis. We assessed plasma cystatin C as an indicator of GFR in such patients. METHODS:We studied 36 patients with decompensated liver ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orlando R,Mussap M,Plebani M,Piccoli P,De Martin S,Floreani M,Padrini R,Palatini P

    更新日期:2002-06-01 00:00:00

  • Measurement of free and free-plus-peptide hydroxyproline fractions in plasma.

    abstract::Plasma hydroxyproline fractions--free-plus-peptide and free--were determined by a method involving centrifugal ultrafiltration and the procedure of Kivirikko et al. [Anal. Biochem. 19, 249 (1967)]. Within- and between-day precision (CV) for the combined fractions was 4--5% and 2.8--6%, respectively. Mean analytical re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Husdan H,Leung M,Oreopoulos D,Rapoport A

    更新日期:1978-02-01 00:00:00

  • Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: two techniques evaluated and modified for improved performance.

    abstract::We evaluated the EMIT (enzyme-multiplied immuno technique) and FPIA (fluorescence polarization immunoassay) urine screening systems for detection of benzodiazepine intake. Healthy male volunteers were given single oral therapeutic doses of alprazolam (2 mg), chlordiazepoxide (25 mg), flunitrazepam (1 mg), lorazepam (3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Beck O,Lafolie P,Hjemdahl P,Borg S,Odelius G,Wirbing P

    更新日期:1992-02-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

    abstract:BACKGROUND:The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS:We tested 18 specimens after centrifuga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.6.935

    authors: Grenache DG,Parvin CA,Gronowski AM

    更新日期:2003-06-01 00:00:00

  • Urokinase plasminogen activator: a prognostic marker in breast cancer including patients with axillary node-negative disease.

    abstract::Urokinase plasminogen activator (uPA) is a serine protease causally involved in cancer invasion and metastasis. In this study, high concentrations of uPA in primary breast cancers were independently associated with both a shortened disease-free interval and overall survival. For the disease-free interval as endpoint, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duffy MJ,Duggan C,Mulcahy HE,McDermott EW,O'Higgins NJ

    更新日期:1998-06-01 00:00:00

  • Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

    abstract:BACKGROUND:The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.107508

    authors: Shaikh A,Seegmiller JC,Borland TM,Burns BE,Ladwig PM,Singh RJ,Kumar R,Larson TS,Lieske JC

    更新日期:2008-09-01 00:00:00

  • C-reactive protein uptake by macrophage cell line via class-A scavenger receptor.

    abstract:BACKGROUND:C-reactive protein (CRP) increases in response to inflammation and is purported to be a risk factor for atherogenesis. We recently demonstrated that a scavenger receptor, lectin-like oxidized LDL receptor (LOX-1), is a receptor for CRP. In light of the overlapping ligand spectrum of scavenger receptors such ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.140202

    authors: Fujita Y,Kakino A,Harada-Shiba M,Sato Y,Otsui K,Yoshimoto R,Sawamura T

    更新日期:2010-03-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Two-site enzyme immunoassay of CD4 and CD8 molecules on the surface of T lymphocytes from healthy subjects and HIV-1-infected patients.

    abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Carriere D,Fontaine C,Berthier AM,Rouquette AM,Carayon P,Laprode M,Juillard R,Jansen A,Paoli P,Paolucci F

    更新日期:1994-01-01 00:00:00

  • Plasma apolipoproteins A-I and B in survivors of myocardial infarction and in a control group.

    abstract::The values of apolipoproteins (apo) A-I and B were determined in a population sample of hospital outpatients with a standardized method to verify if the cutpoints calculated in a cross-sectional study in the US are usable with other populations. We also tested the apolipoproteins' ability to discriminate between healt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graziani MS,Zanolla L,Righetti G,Marchetti C,Mocarelli P,Marcovina SM

    更新日期:1998-01-01 00:00:00

  • Improved 63Ni radiochemical assay of free fatty acids in plasma.

    abstract::We have modified the 63Ni radiochemical method of Ho (Anal Biochem 1970;36:105) for determination of free fatty acids (FFA) in plasma. Extracting 1 or 0.1 mL of plasma with Dole's mixture (J Biol Chem 1960;235:2595) and washing the "heptane" layer with two volumes of isopropanol/water/dilute (0.5 mol/L) H2SO4 (25/25/1...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Barash H,Akov S

    更新日期:1987-01-01 00:00:00

  • Iron and total iron-binding capacity in serum of patients receiving iron-dextran: Kodak Ektachem methodologies, spectrophotometry, and atomic-absorption spectrometry compared.

    abstract::We compared the analytical performance of the Kodak Ektachem XR700 assays of iron (Fe) and total iron-binding capacity (TIBC) with that of a conventional ferrozine assay (performed with a Cobas-Bio) and occasionally with that of atomic-absorption spectrometry (AAS). The correlation was modest between Kodak and Cobas-B...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vercammen M,Goedhuys W,Boeyckens A,De Roy R,Sennesael J,Sevens C,Gorus F

    更新日期:1990-10-01 00:00:00

  • Measurement of the complex between prostate-specific antigen and alpha1-protease inhibitor in serum.

    abstract:BACKGROUND:Prostate-specific antigen (PSA) occurs in serum both free and in complex with protease inhibitors. The complex with alpha1-antichymotrypsin (ACT) is the major form in serum, and the proportion of PSA-ACT is higher in prostate cancer (PCa) than in benign prostatic hyperplasia (BPH). PSA also forms a complex w...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Zhang WM,Finne P,Leinonen J,Vesalainen S,Nordling S,Stenman UH

    更新日期:1999-06-01 00:00:00

  • The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

    abstract::We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. un...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilke TJ,Utley DJ

    更新日期:1988-07-01 00:00:00

  • Inadequate hemolysis of erythrocytes on reagent strips at low pH causes false-negative readings.

    abstract::Patients' urines gave an unexpectedly high percentage of false-negative results for erythrocytes on a reagent strip, even when the test field for ascorbic acid indicated that none of this substance was present to inhibit the test reaction. By adding known amounts of erythrocytes to normal urines, we found that this ph...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Levin K,Engström I

    更新日期:1984-11-01 00:00:00

  • Is determination of creatine kinase-2 after electrophoretic separation accurate?

    abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Henderson AR,Stark JA,McQueen MJ,Patten RL,Krishnan S,Wood DE,Webb S

    更新日期:1994-02-01 00:00:00

  • No influence of the MDR-1 C3435T polymorphism or a CYP3A4 promoter polymorphism (CYP3A4-V allele) on dose-adjusted cyclosporin A trough concentrations or rejection incidence in stable renal transplant recipients.

    abstract:BACKGROUND:A substantial proportion of the variability in the absorption and clearance of cyclosporin A (CsA) after oral administration has been attributed to variability in liver cytochrome P-450 3A4 (CYP3A4) activity and intestinal P-glycoprotein (P-gp) concentration. A polymorphism in the CYP3A4 promoter region, ter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Ahsen N,Richter M,Grupp C,Ringe B,Oellerich M,Armstrong VW

    更新日期:2001-06-01 00:00:00

  • Capillary electrophoresis for detection of inherited disorders of purine and pyrimidine metabolism.

    abstract:BACKGROUND:Measurement of purine and pyrimidine metabolites presents complex problems for separations currently performed by HPLC and thin-layer chromatography in clinical practice. We developed a novel capillary electrophoresis method for this purpose. METHODS:Separations were performed in 60 mmol/L borate-2-amino-2-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adam T,Friedecký D,Fairbanks LD,Sevcík J,Barták P

    更新日期:1999-12-01 00:00:00

  • "Sandwich" enzyme immunoassay for serum ferritin with polypropylene test tubes as the solid phase.

    abstract::A "sandwich" enzyme immunoassay for ferritin in human serum is described, in which horseradish peroxidase-labeled antibody and a very sensitive chromogen, 2,2'-azino-di(3-ethyl-benzthiazolin-6-sulfonate), are used. The solid phase is polypropylene test tubes treated with glutaraldehyde; immunologic reactions are devel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Revenant MC

    更新日期:1983-04-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • Seasonal and sex variation of high-sensitivity C-reactive protein in healthy adults: a longitudinal study.

    abstract:BACKGROUND:Cross-sectional studies have reported seasonal variation in high-sensitivity C-reactive protein (hsCRP). However, longitudinal data are lacking. METHODS:We collected data on diet, physical activity, psychosocial factors, physiology, and anthropometric measurements from 534 healthy adults (mean age 48 years,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111245

    authors: Chiriboga DE,Ma Y,Li W,Stanek EJ 3rd,Hébert JR,Merriam PA,Rawson ES,Ockene IS

    更新日期:2009-02-01 00:00:00

  • The "HemoQuant" test: a specific and quantitative determination of heme (hemoglobin) in feces and other materials.

    abstract::We describe a new, specific, quantitative method for fecal blood, based on conversion of nonfluorescing heme to fluorescing porphyrins, that obviates serious deficiencies inherent in currently used tests. A two-reagent system is used to determine the two hemoglobin-related fractions that are found in feces. The hot ci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz S,Dahl J,Ellefson M,Ahlquist D

    更新日期:1983-12-01 00:00:00

  • Adenosine deaminase binding protein, a new diagnostic marker for kidney disease.

    abstract::This enzyme immunoassay detects adenosine deaminase binding protein (ABP), a glycoprotein that is shed from the brush border of the proximal tubule in kidney damage. Two monoclonal antibodies, URO-4 and URO-4a, each react with different epitopes on ABP and are used as the "sandwich" pair of antibodies. A linear standa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson RE,Piper DJ,Galberg C,Chan TH,Tolkoff-Rubin NE,Rubin RH

    更新日期:1985-05-01 00:00:00