Abstract:
:A patient with the hyperviscosity syndrome exhibited very high concentrations of intermediate to small circulating immune complexes (CIC), involving 40-50% of the IgG present, with IgG rheumatoid factor activity. We demonstrate that precipitation of CIC by polyethylene glycol in the reaction mixture caused interference with nephelometric methods for measuring IgM and IgA, and that failure of immunoglobulins to migrate, owing to molecular interactions, caused interference with radial immunodiffusion methods. Semiquantitative values for immunoglobulins were difficult to interpret on immunoelectrophoresis. As a result, IgM and IgA could only be quantitatively estimated by an end-point nephelometric approach that included a serum blank. Immunoelectrophoresis indicated that a large proportion of the immunoglobulins behaved as aggregates. Immunofixation electrophoresis did not reveal the presence of aggregates. The polyethylene glycol-IgG test provided an accurate assessment of the CIC concentration; the Raji cell and C1q-binding assays did not. Evidently, special techniques may be necessary for accurate determination of immunoglobulin concentrations when CIC concentrations are very high.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Levinson SS,Perry M,Goldman J,Nathan LEsubject
Has Abstractpub_date
1988-04-01 00:00:00pages
784-7issue
4eissn
0009-9147issn
1530-8561journal_volume
34pub_type
杂志文章abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-04-01 00:00:00
abstract::We have developed a new assay for cortisone (E) in serum, saliva, and urine involving Celite chromatography followed by RIA with 125I-labeled E and scintillation proximity assay. The chromatography step separates cortisol (F) from E, and in combination with their RIAs, permits assessment of the status of the F-E shutt...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-08-01 00:00:00
abstract::We produced and characterized several monoclonal antibodies directed toward human plasma apolipoprotein A-I. Two of them, A-I-12 and A-I-57, individually precipitated purified or native high-density lipoprotein in agarose gel by double immunodiffusion. Because radial immunodiffusion performed with a single monoclonal ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-12-01 00:00:00
abstract::Various laboratories have reported endogenous digoxin-like immunoreactive factor(s) (DLIF) in blood from patients in renal failure or liver failure, from newborn infants, and from third-trimester pregnant women. Similar immunoreactivity has been detected in amniotic fluid, in cord blood, and in urine and serum from no...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1985-09-01 00:00:00
abstract::We describe a simple method in which a water-soluble mixture of triocatanoin and a surfactant, "Triton X-114," are used in preparing solutions of triglycerides (triacylglycerols) in either human serum, solutions of albumin, or water. Analytical recovery added triglyceride was quantitative by two methods. The addition ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-08-01 00:00:00
abstract:BACKGROUND:The aims of this study were to measure the N-terminal fragment of pro-brain natriuretic peptide (proBNP) in plasma in medical conditions commonly found in primary care and to evaluate the utility of these measurements in identifying impaired cardiac function in elderly patients with symptoms associated with ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.8.1337
更新日期:2003-08-01 00:00:00
abstract::Single-strand conformation polymorphism (SSCP) analysis is widely used to prescreen mutations in p53 gene. However, standardization of SSCP to detect p53 mutations has rarely been pursued so far. We have developed complete conditions for a temperature-controlled nonradioactive SSCP for mutation detection in amplified ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-12-01 00:00:00
abstract:BACKGROUND:The time required for bloodstream pathogen detection, identification (ID), and antimicrobial susceptibility testing (AST) does not satisfy the acute needs of disease management. Conventional methods take up to 3 days for ID and AST. Molecular diagnostics have reduced times for ID, but their promise to suppla...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.290189
更新日期:2018-10-01 00:00:00
abstract::This semi-automated colorimetric assay for the MB isoenzyme of creatine kinase (EC 2.7.3.2) is based on a monoclonal antibody ("Conan-MB") specific for this isoenzyme and is a modification of a previously published method (Vaidya et al., Clin Chem 1986;32:657-63). A 0.64-cm bead coated with 2 to 3 micrograms of antibo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-03-01 00:00:00
abstract::To understand the regulation of immunity one must understand the processes and the consequences of the activation of the lymphoid cell, its clonal proliferation, and the ultimate differentiation of the progeny into the effector elements that constitute the immune system. By use of polyclonal mitogens, individual T-cel...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-12-01 00:00:00
abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-12-01 00:00:00
abstract::We measured serum protein and calcium concentrations in 2340 individuals between 10 and 96 years of age from 900 families chosen by probability methods to give a representative population. These values were used to calculate an index, based on a regression analysis of serum protein on calcium, which was then treated a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-12-01 00:00:00
abstract::Human myocardial creatine kinase isoenzyme MM is present as a single form in tissue, but upon its release into plasma two additional forms, with faster anodal migration, are apparent on polyacrylamide electrophoresis. We designate the three forms as MM3, MM2, and MM1 in increasing order of anodal mobility. When tissue...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-05-01 00:00:00
abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-04-01 00:00:00
abstract::This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantifi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-12-01 00:00:00
abstract::We evaluated a new EMIT II monoclonal amphetamine/methamphetamine assay for screening human urine by comparing it with the EMIT d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg/L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-02-01 00:00:00
abstract::Ornithine carbamoyltransferase (EC 2.1.3.3) activity is a sensitive, specific indicator of hepatocellular injury. This paper describes development of an improved automated procedure for measurement of this activity. Triethanolamine-ethylenediaminetetraacetate is used as a buffer, and activity is determined by measurin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.127241
更新日期:2009-10-01 00:00:00
abstract::Zinc is determined in neutrophils and lymphocytes (isolated from whole blood on discontinuous gradients of Ficoll-Hypaque) and in microliter quantities of plasma and erythrocytes by flameless atomic absorption spectrophotometry with greater sensitivity than with conventional flame atomic absorption spectrophotometry. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-03-01 00:00:00
abstract::We studied the recently developed Abbott fluorescence polarization immunoassay (FPIA) for amphetamine and methamphetamine in urine and compared the results with those of the Syva enzyme-multiplied immunoassay technique (EMIT) and a gas-chromatographic assay. The FPIA method showed a limit of quantification of 0.3 mg/L...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-07-01 00:00:00
abstract:BACKGROUND:The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2015.242081
更新日期:2015-10-01 00:00:00
abstract:BACKGROUND:A simple point-of-care method for measuring leukocyte counts in a doctor's office or emergency room could be of great importance. We developed a protocol for measuring cell count by disrupting the cell membrane and analyzing specific proteins within the cells and used it to analyze proteins from eosinophils ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.074021
更新日期:2007-02-01 00:00:00
abstract::This time-resolved immunofluorometric assay (IFMA) developed for measurement of placental protein 5 (PP5) involves two antibodies: a monoclonal anti-PP5 antibody attached to a solid phase and an europium(III) chelate-labeled polyclonal anti-PP5 antibody as a tracer. The measuring range is 0.05-100 micrograms/L and the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-08-01 00:00:00
abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.268656
更新日期:2017-05-01 00:00:00
abstract:BACKGROUND:Astilbin is a flavonoid isolated from the rhizome of Smilax glabra. In a previous study, we revealed its unique immunosuppressive activity, a selective inhibition against activated T lymphocytes. This characteristic of astilbin is beneficial for the treatment of human immune diseases. METHODS:We incubated a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.077297
更新日期:2007-03-01 00:00:00
abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1991-10-01 00:00:00
abstract::We recently proposed a quantitative PCR procedure for the absolute measurement of c-erbB-2 oncogene amplification, based on the simultaneous polymerase chain reaction (PCR) amplification of the target gene and of a competitor DNA molecule acting as internal standard. To increase the number of assayable oncogenes and t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-06-01 00:00:00