Erroneous results with routine laboratory testing for immunoglobulins due to interference from circulating immune complexes in a case of hyperviscosity syndrome associated with autoimmune disease.

Abstract:

:A patient with the hyperviscosity syndrome exhibited very high concentrations of intermediate to small circulating immune complexes (CIC), involving 40-50% of the IgG present, with IgG rheumatoid factor activity. We demonstrate that precipitation of CIC by polyethylene glycol in the reaction mixture caused interference with nephelometric methods for measuring IgM and IgA, and that failure of immunoglobulins to migrate, owing to molecular interactions, caused interference with radial immunodiffusion methods. Semiquantitative values for immunoglobulins were difficult to interpret on immunoelectrophoresis. As a result, IgM and IgA could only be quantitatively estimated by an end-point nephelometric approach that included a serum blank. Immunoelectrophoresis indicated that a large proportion of the immunoglobulins behaved as aggregates. Immunofixation electrophoresis did not reveal the presence of aggregates. The polyethylene glycol-IgG test provided an accurate assessment of the CIC concentration; the Raji cell and C1q-binding assays did not. Evidently, special techniques may be necessary for accurate determination of immunoglobulin concentrations when CIC concentrations are very high.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Levinson SS,Perry M,Goldman J,Nathan LE

subject

Has Abstract

pub_date

1988-04-01 00:00:00

pages

784-7

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

34

pub_type

杂志文章
  • Effect of carbon cup aging on plasma zinc determination by flameless atomic adosorption spectrometry.

    abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chooi MK,Todd JK,Boyd ND

    更新日期:1975-04-01 00:00:00

  • Radioimmunoassay of cortisone in serum, urine, and saliva to assess the status of the cortisol-cortisone shuttle.

    abstract::We have developed a new assay for cortisone (E) in serum, saliva, and urine involving Celite chromatography followed by RIA with 125I-labeled E and scintillation proximity assay. The chromatography step separates cortisol (F) from E, and in combination with their RIAs, permits assessment of the status of the F-E shutt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Morineau G,Boudi A,Barka A,Gourmelen M,Degeilh F,Hardy N,al-Halnak A,Soliman H,Gosling JP,Julien R,Brerault JL,Boudou P,Aubert P,Villette JM,Pruna A,Galons H,Fiet J

    更新日期:1997-08-01 00:00:00

  • Radial-immunodiffusion assay of human apolipoprotein A-I with use of two monoclonal antibodies combined.

    abstract::We produced and characterized several monoclonal antibodies directed toward human plasma apolipoprotein A-I. Two of them, A-I-12 and A-I-57, individually precipitated purified or native high-density lipoprotein in agarose gel by double immunodiffusion. Because radial immunodiffusion performed with a single monoclonal ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Marcovina S,Di Cola G,Catapano AL

    更新日期:1986-12-01 00:00:00

  • Endogenous digoxin-like immunoreactive factors: impact on digoxin measurements and potential physiological implications.

    abstract::Various laboratories have reported endogenous digoxin-like immunoreactive factor(s) (DLIF) in blood from patients in renal failure or liver failure, from newborn infants, and from third-trimester pregnant women. Similar immunoreactivity has been detected in amniotic fluid, in cord blood, and in urine and serum from no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Valdes R Jr

    更新日期:1985-09-01 00:00:00

  • Addition of triglyceride to serum for use in quality control and reference.

    abstract::We describe a simple method in which a water-soluble mixture of triocatanoin and a surfactant, "Triton X-114," are used in preparing solutions of triglycerides (triacylglycerols) in either human serum, solutions of albumin, or water. Analytical recovery added triglyceride was quantitative by two methods. The addition ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bonderman DP,Proksch GJ,Bonderman PW

    更新日期:1976-08-01 00:00:00

  • Utility of the amino-terminal fragment of pro-brain natriuretic peptide in plasma for the evaluation of cardiac dysfunction in elderly patients in primary health care.

    abstract:BACKGROUND:The aims of this study were to measure the N-terminal fragment of pro-brain natriuretic peptide (proBNP) in plasma in medical conditions commonly found in primary care and to evaluate the utility of these measurements in identifying impaired cardiac function in elderly patients with symptoms associated with ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.8.1337

    authors: Alehagen U,Lindstedt G,Eriksson H,Dahlström U

    更新日期:2003-08-01 00:00:00

  • Single-strand conformation polymorphism analysis to detect p53 mutations: characterization and development of controls.

    abstract::Single-strand conformation polymorphism (SSCP) analysis is widely used to prescreen mutations in p53 gene. However, standardization of SSCP to detect p53 mutations has rarely been pursued so far. We have developed complete conditions for a temperature-controlled nonradioactive SSCP for mutation detection in amplified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Welsh JA,Castrén K,Vähäkangas KH

    更新日期:1997-12-01 00:00:00

  • A "Culture" Shift: Broad Bacterial Detection, Identification, and Antimicrobial Susceptibility Testing Directly from Whole Blood.

    abstract:BACKGROUND:The time required for bloodstream pathogen detection, identification (ID), and antimicrobial susceptibility testing (AST) does not satisfy the acute needs of disease management. Conventional methods take up to 3 days for ID and AST. Molecular diagnostics have reduced times for ID, but their promise to suppla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.290189

    authors: Andini N,Hu A,Zhou L,Cogill S,Wang TH,Wittwer CT,Yang S

    更新日期:2018-10-01 00:00:00

  • Semi-automated direct colorimetric measurement of creatine kinase isoenzyme MB activity after extraction from serum by use of a CK-MB-specific monoclonal antibody.

    abstract::This semi-automated colorimetric assay for the MB isoenzyme of creatine kinase (EC 2.7.3.2) is based on a monoclonal antibody ("Conan-MB") specific for this isoenzyme and is a modification of a previously published method (Vaidya et al., Clin Chem 1986;32:657-63). A 0.64-cm bead coated with 2 to 3 micrograms of antibo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Landt Y,Vaidya HC,Porter SE,Whalen K,McClellan A,Amyx C,Parvin CA,Kessler G,Nahm MH,Dietzler DN

    更新日期:1988-03-01 00:00:00

  • An approach to molecular analysis of T-cell clones by two-dimensional gel electrophoresis: is there interclonal and intraclonal heterogeneity?

    abstract::To understand the regulation of immunity one must understand the processes and the consequences of the activation of the lymphoid cell, its clonal proliferation, and the ultimate differentiation of the progeny into the effector elements that constitute the immune system. By use of polyclonal mitogens, individual T-cel...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kettman J,Lefkovits I

    更新日期:1984-12-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00

  • Use of values for calcium and protein in serum, and of a derived index obtained from a probability population sample.

    abstract::We measured serum protein and calcium concentrations in 2340 individuals between 10 and 96 years of age from 900 families chosen by probability methods to give a representative population. These values were used to calculate an index, based on a regression analysis of serum protein on calcium, which was then treated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kelly A,Munan L,PetitClerc C,Ho KP,Billon B

    更新日期:1976-10-01 00:00:00

  • Analytical performance of EMIT cyclosporine assay evaluated.

    abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Desai M

    更新日期:1991-12-01 00:00:00

  • Carboxypeptidase-catalyzed hydrolysis of C-terminal lysine: mechanism for in vivo production of multiple forms of creatine kinase in plasma.

    abstract::Human myocardial creatine kinase isoenzyme MM is present as a single form in tissue, but upon its release into plasma two additional forms, with faster anodal migration, are apparent on polyacrylamide electrophoresis. We designate the three forms as MM3, MM2, and MM1 in increasing order of anodal mobility. When tissue...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Perryman MB,Knell JD,Roberts R

    更新日期:1984-05-01 00:00:00

  • Improved column-chromatographic isolation of glycosylated hemoglobin S.

    abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cirotto C,Allegrucci M,Cartechini MG,Compagnucci P,Santeusanio F,Bolli G

    更新日期:1985-04-01 00:00:00

  • One-step chemiluminescent immunoassay of free thyroxin with acridinium-ester-labeled thyroxin evaluated and compared with a two-step radioimmunoassay.

    abstract::This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantifi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bounaud JY,Bounaud MP,Begon F

    更新日期:1988-12-01 00:00:00

  • Analytical performance evaluation of EMIT II monoclonal amphetamine/methamphetamine assay: more specificity than EMIT d.a.u. monoclonal amphetamine/methamphetamine assay.

    abstract::We evaluated a new EMIT II monoclonal amphetamine/methamphetamine assay for screening human urine by comparing it with the EMIT d.a.u. monoclonal amphetamine/methamphetamine assay and a fluorescence polarization assay. The EMIT II assay has a cutoff of 1 mg/L d-methamphetamine. The EMIT II and EMIT d.a.u. assays were ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Kinnaman G,Smith M,Johansen K

    更新日期:1993-01-01 00:00:00

  • Determination of quinidine by high-performance liquid chromatography.

    abstract::Quinidine in serum was measured at 330 nm, after protein precipitation, with an alkyl phenyl reversed-phase chromatographic column by peak-height determination (external standards.) Sensitivity was 0.3 mg/liter, with linear response to at least 10 mg/liter serum. Interassay precision, measured on 20 consecutive days, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Powers JL,Sadee W

    更新日期:1978-02-01 00:00:00

  • A more sensitive automated method for determination of ornithine carbamoyltransferase activity in human serum.

    abstract::Ornithine carbamoyltransferase (EC 2.1.3.3) activity is a sensitive, specific indicator of hepatocellular injury. This paper describes development of an improved automated procedure for measurement of this activity. Triethanolamine-ethylenediaminetetraacetate is used as a buffer, and activity is determined by measurin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Clayson KJ,Fine JS,Strandjord PE

    更新日期:1975-05-01 00:00:00

  • Short- and long-term risk stratification using a next-generation, high-sensitivity research cardiac troponin I (hs-cTnI) assay in an emergency department chest pain population.

    abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.127241

    authors: Kavsak PA,Wang X,Ko DT,MacRae AR,Jaffe AS

    更新日期:2009-10-01 00:00:00

  • Zinc in plasma, neutrophils, lymphocytes, and erythrocytes as determined by flameless atomic absorption spectrophotometry.

    abstract::Zinc is determined in neutrophils and lymphocytes (isolated from whole blood on discontinuous gradients of Ficoll-Hypaque) and in microliter quantities of plasma and erythrocytes by flameless atomic absorption spectrophotometry with greater sensitivity than with conventional flame atomic absorption spectrophotometry. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whitehouse RC,Prasad AS,Rabbani PI,Cossack ZT

    更新日期:1982-03-01 00:00:00

  • Fluorescence polarization immunoassay evaluated for screening for amphetamine and methamphetamine in urine.

    abstract::We studied the recently developed Abbott fluorescence polarization immunoassay (FPIA) for amphetamine and methamphetamine in urine and compared the results with those of the Syva enzyme-multiplied immunoassay technique (EMIT) and a gas-chromatographic assay. The FPIA method showed a limit of quantification of 0.3 mg/L...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Caplan YH,Levine B,Goldberger B

    更新日期:1987-07-01 00:00:00

  • Fully automated ultrasensitive digital immunoassay for cardiac troponin I based on single molecule array technology.

    abstract:BACKGROUND:The association between increases in cardiac troponin and adverse cardiac outcomes is well established. There is a growing interest in exploring routine cardiac troponin monitoring as a potential early indicator of adverse heart health trends. Prognostic use of cardiac troponin measurements requires an assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.242081

    authors: Jarolim P,Patel PP,Conrad MJ,Chang L,Melenovsky V,Wilson DH

    更新日期:2015-10-01 00:00:00

  • Lateral flow immunoassay using Europium (III) chelate microparticles and time-resolved fluorescence for eosinophils and neutrophils in whole blood.

    abstract:BACKGROUND:A simple point-of-care method for measuring leukocyte counts in a doctor's office or emergency room could be of great importance. We developed a protocol for measuring cell count by disrupting the cell membrane and analyzing specific proteins within the cells and used it to analyze proteins from eosinophils ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.074021

    authors: Rundström G,Jonsson A,Mårtensson O,Mendel-Hartvig I,Venge P

    更新日期:2007-02-01 00:00:00

  • Immunofluorometric demonstration and quantification of placental protein 5 in the absence of pregnancy.

    abstract::This time-resolved immunofluorometric assay (IFMA) developed for measurement of placental protein 5 (PP5) involves two antibodies: a monoclonal anti-PP5 antibody attached to a solid phase and an europium(III) chelate-labeled polyclonal anti-PP5 antibody as a tracer. The measuring range is 0.05-100 micrograms/L and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bützow R,Alfthan H,Stenman UH,Suikkari AM,Bohn H,Seppälä M

    更新日期:1988-08-01 00:00:00

  • Single-Stranded DNA Library Preparation Preferentially Enriches Short Maternal DNA in Maternal Plasma.

    abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268656

    authors: Vong JSL,Tsang JCH,Jiang P,Lee WS,Leung TY,Chan KCA,Chiu RWK,Lo YMD

    更新日期:2017-05-01 00:00:00

  • Identification of a new metabolite of astilbin, 3'-O-methylastilbin, and its immunosuppressive activity against contact dermatitis.

    abstract:BACKGROUND:Astilbin is a flavonoid isolated from the rhizome of Smilax glabra. In a previous study, we revealed its unique immunosuppressive activity, a selective inhibition against activated T lymphocytes. This characteristic of astilbin is beneficial for the treatment of human immune diseases. METHODS:We incubated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077297

    authors: Guo J,Qian F,Li J,Xu Q,Chen T

    更新日期:2007-03-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Gene amplification for c-erbB-2, c-myc, epidermal growth factor receptor, int-2, and N-myc measured by quantitative PCR with a multiple competitor template.

    abstract::We recently proposed a quantitative PCR procedure for the absolute measurement of c-erbB-2 oncogene amplification, based on the simultaneous polymerase chain reaction (PCR) amplification of the target gene and of a competitor DNA molecule acting as internal standard. To increase the number of assayable oncogenes and t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sestini R,Orlando C,Zentilin L,Lami D,Gelmini S,Pinzani P,Giacca M,Pazzagli M

    更新日期:1995-06-01 00:00:00