Abstract:
:We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fraction whose properties, as determined by chromatography, electrophoresis, and two-dimensional maps of its tryptic peptides, were typical of a hemoglobin S tetramer with blocked N-terminal residues of the beta subunits. The colorimetric test indicated this to be a glycosylated hemoglobin. This procedure is notably improved over previous chromatographic techniques for isolating glycosylated hemoglobin S. Moreover, it can be easily used in any laboratories where Trivelli's method is routinely in use.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Cirotto C,Allegrucci M,Cartechini MG,Compagnucci P,Santeusanio F,Bolli Gsubject
Has Abstractpub_date
1985-04-01 00:00:00pages
631-3issue
4eissn
0009-9147issn
1530-8561journal_volume
31pub_type
杂志文章abstract::The reaction of 5,5'-dithiobis(2-nitrobenzoic acid) (DTNB, Ellman's reagent) with thiols is sensitive to daylight, in particular to ultraviolet radiation at wavelengths around 325 nm. Exposure to light at the absorbance maximum of the yellow product (the thionitrobenzoate ion) at 410 nm had no effect on the reaction. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-10-01 00:00:00
abstract::We have developed a fully enzymatic method to measure 1,5 anhydro-D-glucitol (1,5-AG) in serum through use of pyranose oxidase (PROD: EC 1.1.3.10), glucokinase (EC 2.7.1.2), and an ATP-regenerating system. In a previous report (Clin Chem 1989;35:2039-43) the glucose interfering with the measurement of 1,5-AG was remov...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-11-01 00:00:00
abstract::Alanine aminotransferase activity in serum increases significantly when serum is incubated with pyridoxal phosphate. The increase depends on the L-alanine concentration in the final assay mixture, being greatest at 800 mmol/liter. Preincubation of 22 normal sera, in a 10:1 ratio with an 8.09 mmol/liter pyridoxal phosp...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-02-01 00:00:00
abstract:BACKGROUND:In the workup of patients with suspected hereditary nonpolyposis colorectal cancer (HNPCC), detection of loss of heterozygosity (LOH) could help pinpoint the mismatch-repair (MMR) gene carrying the germline mutation, but analysis of microsatellite markers has proved unreliable for this purpose. We developed ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.108902
更新日期:2008-11-01 00:00:00
abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2005.052456
更新日期:2005-11-01 00:00:00
abstract:BACKGROUND:External quality assurance (EQA) programs for diagnostic tests based on nucleic acid amplification have not been widely implemented in clinical laboratories and remain limited to few tests. Development of specific EQA programs based on application-based proficiency testing for any diagnostic molecular target...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.5.782
更新日期:2003-05-01 00:00:00
abstract::Currently, we can make the following generalizations about the major long-term complications of diabetes. First, they occur commonly after 10 to 15 years of diabetes. Second, the complications of renal and retinal disease, but not of atherogenic and neurological disease, appear to be related to the severity of hypergl...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,评审
doi:
更新日期:1986-10-01 00:00:00
abstract::We describe a convenient, economical procedure for measuring uroporphyrinogen I synthase (EC 4.3 1.8) activity in erythrocytes, the results of which can be used to diagnose acute intermittent porphyria, in either its latent or acute stage. By limiting the test reaction sequence to the conversion of porphobilinogen to ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-07-01 00:00:00
abstract::A modified pentamer formation assay (PFA) for quantification of tacrolimus and active metabolites after extraction from whole blood is described. The lower limit of detection was 2 microg/L. Intraassay precision (CV) was 5.7-13.7%, and the interassay CV was 6. 1-14.9%. Tacrolimus trough concentrations in 104 whole blo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-12-01 00:00:00
abstract::We describe specifications for high-purity 4-nitrophenol, which is suitable for spectrophotometric standardization. Such a reference material is needed in clinical enzymology to establish the proper molar absorptivity of 4-nitrophenol under final reaction conditions, particularly for measuring alkaline phosphatase act...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-05-01 00:00:00
abstract:BACKGROUND:Gradient gel electrophoresis (GGE) and nuclear magnetic resonance (NMR) spectroscopy are both widely accepted methods for measuring LDL and HDL particle size. However, whether or not GGE- or NMR-measured LDL or HDL particle size predicts coronary heart disease (CHD) risk to a similar extent is currently unkn...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.140939
更新日期:2010-05-01 00:00:00
abstract::A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-09-01 00:00:00
abstract:BACKGROUND:Genotyping methods that reveal single-nucleotide differences are useful for a wide range of applications. We used digestion of 3-way DNA junctions in a novel technology, OneCutEventAmplificatioN (OCEAN) that allows sequence-specific signal generation and amplification. We combined OCEAN with peptide-nucleic-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.068817
更新日期:2006-10-01 00:00:00
abstract:BACKGROUND:FMR1 full mutations (FMs) (CGG expansion >200) in males mosaic for a normal (<45 CGG) or gray-zone (GZ) (45-54 CGG) allele can be missed with the standard 2-step fragile X syndrome (FXS) testing protocols, largely because the first-line PCR tests showing a normal or GZ allele are not reflexed to the second-l...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2015.244681
更新日期:2016-02-01 00:00:00
abstract::Hemoglobinometry according to the International Committee of Standardization in Hematology (ICSH) suffers from imprecision related to high sample dilution and from potential errors owing to sample turbidity. We have evaluated a new instrument, "HemoCue," that measures hemoglobin at two wavelengths as azide methemoglob...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-03-01 00:00:00
abstract::The Arg-to-Trp substitution at codon 3500 in the apolipoprotein (apo) B-100 gene is established as a cause of familial defective apo B-100 (FDB), a functional mutation, resulting in reduced LDL receptor binding and manifest hypercholesterolemia. In a search for similar mutations in 163 Malaysians, we screened the puta...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-06-01 00:00:00
abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.026591
更新日期:2004-04-01 00:00:00
abstract:BACKGROUND:Although cardiac troponin (cTn) is a cornerstone marker in the assessment and management of patients with acute coronary syndrome (ACS) and heart failure (HF), cTn is not diagnostically specific for any single myocardial disease process. This narrative review discusses increases in cTn that result from acute...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2009.130799
更新日期:2009-12-01 00:00:00
abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-10-01 00:00:00
abstract::A new, highly sensitive immunoradiometric thyrotropin (TSH) assay involving solid-phase-coupled monoclonal antibodies (Boots-Celltech Sucrosep IRMA-TSH) has been evaluated in a wide variety of patients with thyroidal and nonthyroidal illnesses and the results compared with those obtained by conventional diagnostic TSH...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-03-01 00:00:00
abstract:BACKGROUND:Optimal cutoff values for tests results involving continuous variables are often derived in a data-driven way. This approach, however, may lead to overly optimistic measures of diagnostic accuracy. We evaluated the magnitude of the bias in sensitivity and specificity associated with data-driven selection of ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.096032
更新日期:2008-04-01 00:00:00
abstract::A modified agarose electrophoretic system for the separation of alkaline phosphatase (ALP, EC 3.1.3.1) isoenzymes is described. Bone, liver, high-molecular-mass, and intestinal ALP are separated with high reproducibility. The sensitivity of the agarose system is superior to cellulose acetate in detecting high-Mr ALP. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-09-01 00:00:00
abstract::Cerebrospinal fluid (CSF) from uninfected patients and from patients with bacterial and viral meningitis was analyzed by gas-liquid chromatography, with use of a flame ionization detector, and by gas chromatography-mass spectrometry. The resulting profiles were consistent and reproducible. Hydroxy acids were the compo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-07-01 00:00:00
abstract:BACKGROUND:Formation of deposits of the insoluble amyloid beta-peptide is believed to be causally related with neurodegeneration in Alzheimer disease (AD). The beta-peptide originates from a larger amyloid precursor protein (APP) by the action of proteolytic enzymes. The first proteolytic event leading to amyloid forma...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.066720
更新日期:2006-06-01 00:00:00
abstract::Single-spin density-gradient ultracentrifugation (DUC) has proven to be a reproducible method for detection of low-density-lipoprotein (LDL) heterogeneity. Recently another method has been described for this: gradient gel electrophoresis (GGE) of serum, a method that might be more suitable for screening. To gain insig...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-06-01 00:00:00
abstract::Macromolecular aspartate aminotransferase was found in the serum of an apparently healthy patient. This complex was composed of aspartate aminotransferase (AST; EC 2.6.1.1) and immunoglobulin. Electrophoresis of the patient's serum showed an abnormal band migrating between mitochondrial (m) and cytosolic (s) AST. The ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-07-01 00:00:00
abstract::Throughout the 1970s, controversy centered both on immunoassay "sensitivity" per se and on the relative sensitivities of labeled antibody (Ab) and labeled analyte methods. Our theoretical studies revealed that RIA sensitivities could be surpassed only by the use of very high-specificity nonisotopic labels in "noncompe...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1991-11-01 00:00:00
abstract:BACKGROUND:The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. METHODS:In 2004, we compared 11 commercially available insulin assays by analyz...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2006.077784
更新日期:2007-05-01 00:00:00
abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-09-01 00:00:00
abstract::Methods are described for detection of lactate dehydrogenase (LDH) inhibitors in preparations of reduced nicotinamide adenine dinucleotide. They are (a) comparison of values by kinetic methods with those measured for highly purified NADH and (b) examination of Lineweaver-Burk plots. Chromatographic inhomogeneities are...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00