Overview of the complications of diabetes.

Abstract:

:Currently, we can make the following generalizations about the major long-term complications of diabetes. First, they occur commonly after 10 to 15 years of diabetes. Second, the complications of renal and retinal disease, but not of atherogenic and neurological disease, appear to be related to the severity of hyperglycemia. Third, some complications do not seem to be readily reversible by decreasing blood glucose for one to three years. Fourth, whether retinal and renal disease can be prevented or reduced by an early intervention is not yet known but is under intensive study. Fifth, the risks of some forms of intensive therapy include hypoglycemia, ketoacidosis, skin infection, weight gain, and poor adherence to arduous regimens. Finally, an analysis of the relationship of benefits to risk in intensive therapy is not yet possible and must await further study. Meanwhile, the diabetes research community will need to evaluate whether alternative procedures, e.g., aldose reductase inhibitors or islet transplants, might not be more reasonable than currently available modes of intensive therapy for reducing the long-term complications of diabetes.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Santiago JV

subject

Has Abstract

pub_date

1986-10-01 00:00:00

pages

B48-53

issue

10 Suppl

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

临床试验,杂志文章,评审
  • Disease-related metabolites in culture medium of fibroblasts from patients with D-2-hydroxyglutaric aciduria, L-2-hydroxyglutaric aciduria, and combined D/L-2-hydroxyglutaric aciduria.

    abstract:BACKGROUND:D-2-Hydroxyglutaric aciduria (D-2-HGA), L-2-hydroxyglutaric aciduria (L-2-HGA), and the combined D/L-2-hydroxyglutaric aciduria (D/L-2-HGA) are poorly understood organic acidurias. To investigate the usefulness of cultured human skin fibroblasts for both diagnostic and research purposes, we measured disease-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.7.1133

    authors: Struys EA,Verhoeven NM,Roos B,Jakobs C

    更新日期:2003-07-01 00:00:00

  • A model for medical decision making and problem solving.

    abstract::Clinicians confront the classical problem of decision making under uncertainty, but a universal procedure by which they deal with this situation, both in diagnosis and therapy, can be defined. This consists in the choice of a specific course of action from available alternatives so as to reduce uncertainty. Formal ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Werner M

    更新日期:1995-08-01 00:00:00

  • The National Glycohemoglobin Standardization Program: Over 20 Years of Improving Hemoglobin A1c Measurement.

    abstract:BACKGROUND:Measurement of hemoglobin A1c (HbA1c) in the blood is integral to and essential for the treatment of patients with diabetes mellitus. HbA1c reflects the mean blood glucose concentration over the preceding 8 to 12 weeks. Although the clinical value of HbA1c was initially limited by large differences in result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.296962

    authors: Little RR,Rohlfing C,Sacks DB

    更新日期:2019-07-01 00:00:00

  • Commutability of a Whole-Blood External Quality Assessment Material for Point-of-Care C-Reactive Protein, Glucose, and Hemoglobin Testing.

    abstract:BACKGROUND:The optimal situation in external quality assessment (EQA) is to use commutable materials. No previous study has examined the commutability of a whole-blood material for point-of-care (POC) testing. The aim of this study was to determine the commutability of the Norwegian Quality Improvement of Laboratory Ex...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.300202

    authors: Bukve T,Sandberg S,Vie WS,Sølvik U,Christensen NG,Stavelin A

    更新日期:2019-06-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • A comprehensive assay for CFTR mutational analysis using next-generation sequencing.

    abstract:BACKGROUND:Cystic fibrosis is a life-threatening genetic disorder that has been associated with mutations in the CFTR [cystic fibrosis transmembrane conductance regulator (ATP-binding cassette sub-family C, member 7)] gene. Hundreds of CFTR mutations have been detected to date. Current CFTR genotyping assays target a s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.206466

    authors: Abou Tayoun AN,Tunkey CD,Pugh TJ,Ross T,Shah M,Lee CC,Harkins TT,Wells WA,Tafe LJ,Amos CI,Tsongalis GJ

    更新日期:2013-10-01 00:00:00

  • Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.

    abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ohkubo A,Kamei S,Yamanaka M,Arai F,Kitajima M,Kondo A

    更新日期:1981-07-01 00:00:00

  • Effect of dimethyl sulfoxide on serum osmolality.

    abstract::Consecutive values for serum osmolality measured in a patient exceeded (548 mOsm) the previously reported pathological range and, indeed, exceeded that generally considered compatible with life. The patient was receiving large amounts of intravenous dimethyl sulfoxide as part of an experimental protocol to control int...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Runckel DN,Swanson JR

    更新日期:1980-11-01 00:00:00

  • Rate of decrease in serum ethchlorvynol concentrations after extreme overdosage-a case study.

    abstract::Ethchlorvynol is a commonly abused sedative hypnotic. I report here a seven-day study of serum ethchlorvynol concentrations in a patient who had received an extreme overdose. These concentrations were correlated with the patient's response to stimuli. Serum ethchlorvynol concentrations were logarithmically related to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pochopien DJ

    更新日期:1975-06-01 00:00:00

  • Polyacrylamide gel electrophoresis in quantification of high-density lipoprotein cholesterol.

    abstract::We evaluated a method for quantifying high-density lipoprotein cholesterol in plasma, based on electrophoretic migration of the prestained (with Sudan Black III) sample through a discontinuous polyacrylamide++ gel and densitometric integration of the stain associated with each class of lipoprotein. With this method, o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Roche D,Atger V,Le Quang NT,Girard A,Ekindjian OG

    更新日期:1985-11-01 00:00:00

  • Prostate-specific antigen: a cancer fighter and a valuable messenger?

    abstract:BACKGROUND:Prostate-specific antigen (PSA) is a valuable prostatic cancer biomarker that is now widely used for population screening, diagnosis, and monitoring of patients with prostate cancer. Despite the voluminous literature on this biomarker, relatively few reports have addressed the issue of its physiological func...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Diamandis EP

    更新日期:2000-07-01 00:00:00

  • C-reactive protein and coronary heart disease: predictive test or therapeutic target?

    abstract:BACKGROUND:The hepatocyte-derived acute-phase reactant C-reactive protein (CRP) has been the subject of intense research over the last 2 decades for its possible role in the pathogenesis of cardiovascular diseases. This research has spawned interest in the use of the blood concentration of CRP for predicting a first co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.115923

    authors: Hingorani AD,Shah T,Casas JP,Humphries SE,Talmud PJ

    更新日期:2009-02-01 00:00:00

  • Intra- and interindividual biological variation of five analytes used in assessing thyroid function: implications for necessary standards of performance and the interpretation of results.

    abstract::Intra- and interindividual components of biological variation have been determined for total thyroxin (TT4), free thyroxin (FT4), total triiodothyronine (TT3), free triiodothyronine (FT3), and thyrotropin (TSH). Calculated analytical goals (CV, %) for the precision required for optimal patient care are: TT4 less than ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Browning MC,Ford RP,Callaghan SJ,Fraser CG

    更新日期:1986-06-01 00:00:00

  • Multi-channel, probe colorimeter for use with the micr-ELISA test, which makes use of disposable flat-bottom microhemagglutination plates.

    abstract::We describe a multiprobe colorimeter that permits the reading of enzyme-linked immunosorbent assays (ELISA) in situ, by use of microhemagglutination plates. The use of dipping probes eliminates interference from meniscus effects and air-bubble entrapment. Detailed validation tests have been done and potential sources ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McMurray CH,Blanchflower WJ

    更新日期:1979-04-01 00:00:00

  • Low proportions of glycosylated hemoglobin associated with hemoglobin S and hemoglobin C.

    abstract::Using a cation-exchange chromatographic method, we found normal or subnormal values for glycosylated hemoglobin in a few diabetic patients with persistent hyperglycemia. Subsequent investigations revealed that these unexpected results had originated from black patients with diabetes. In view of common occurrence of ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aleyassine H

    更新日期:1979-08-01 00:00:00

  • Applications of recombinant DNA to pathologic diagnosis.

    abstract::Recombinant DNA techniques are contributing to the understanding of the pathogeneses of genetic, neoplastic, and viral diseases, and are used in the diagnosis of certain genetic and viral diseases. Such techniques will have wider application in the future and will play an increasing role in the clinical laboratory. Th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sauls CD,Caskey CT

    更新日期:1985-06-01 00:00:00

  • Kinetic studies of a quantitative single-tube enzyme-linked immunosorbent assay.

    abstract::We describe a single-cuvette enzyme-linked immunosorbent assay (ELISA) based on enzymic rate kinetics. This kinetic assay can yield linear quantitative data on immunoglobin concentrations. Optimum assay conditions, component concentrations, reaction intervals, and pH are described. Assay linearity and sensitivity are ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsang VC,Wilson BC,Maddison SE

    更新日期:1980-08-01 00:00:00

  • Prevention through health risk management.

    abstract::Risk can lead to catastrophe. Risk-management systems are highly effective in preventing the catastrophes of fire, earthquakes, and work-site injuries. No such effective systems are present to prevent health and social problems. A practical, cost-effective system to manage risk in children is being developed by the no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friedman GM

    更新日期:1992-08-01 00:00:00

  • Assessing the quality of glucose monitor studies: a critical evaluation of published reports.

    abstract:BACKGROUND:In recent years, a large number of studies have been published on the performance of glucose monitors. The quality of these reports is not known. METHODS:We searched the PubMed database for performance evaluations of handheld glucose monitors published from August 2002 to November 2006. Relevant articles we...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.083493

    authors: Mahoney J,Ellison J

    更新日期:2007-06-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00

  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • A more sensitive automated method for determination of ornithine carbamoyltransferase activity in human serum.

    abstract::Ornithine carbamoyltransferase (EC 2.1.3.3) activity is a sensitive, specific indicator of hepatocellular injury. This paper describes development of an improved automated procedure for measurement of this activity. Triethanolamine-ethylenediaminetetraacetate is used as a buffer, and activity is determined by measurin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Clayson KJ,Fine JS,Strandjord PE

    更新日期:1975-05-01 00:00:00

  • Direct solid-phase time-resolved immunofluorometric assay of cortisol in serum.

    abstract::A dissociation-enhanced lanthanide fluoroimmunoassay of serum cortisol based on time-resolved fluorescence is described. The assay is a direct assay, where cortisol immobilized on the wall of a microtiter-strip well competes with cortisol in the sample for the europium-labeled polyclonal antibody. The amount of bound ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eskola JU,Näntö V,Meurling L,Lövgren TN

    更新日期:1985-10-01 00:00:00

  • A modified radioimmunoassay for 1,25-dihydroxycholecalciferol.

    abstract::A radioimmunoassay for 1,25-dihydroxycholecalciferol which did not cross react with 1,25-dihydroxyergocalciferol is described. IgG fractions were prepared from the serum of rabbits that had been immunized with 1,25-dihydroxycholecalciferol-3-hemisuccinate coupled to bovine albumin. Radioligand binding by the IgG fract...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gray TK,McAdoo T,Pool D,Lester GE,Williams ME,Jones G

    更新日期:1981-03-01 00:00:00

  • Serum prostate-specific acid phosphatase: development and validation of a specific radioimmunoassay.

    abstract::We describe radioimmunoassay for human prostatic acid phosphatase [orthophosphoric-monoester phospho-hydrolase (acid optimum), EC 3.1.3.2] in serum, with use of monospecific antisera raised in rabbits against highly purified acid phosphatase from human prostates. The antiserum did not cross react with partly purified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vihko P,Sajanti E,Jänne O,Peltonen L,Vihko R

    更新日期:1978-11-01 00:00:00

  • Ten electrophoretic methods compared with a selected method for quantifying lactate dehydrogenase isoenzymes in serum.

    abstract::Using the Selected Method of McKenzie and Henderson (Selected Methods Clin Chem 1983;10:59-67) as a reference method, we compared the performance of 10 commercially available methods for determination of lactate dehydrogenase (LD, EC 1.1.1.27) isoenzymes. Results were expressed as percentage of total LD activity, as d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moses GC,Ross ML,Henderson AR

    更新日期:1988-09-01 00:00:00

  • Role of biomarkers in identifying and understanding environmentally induced disease.

    abstract::Establishing associations between environmental agents and disease presents challenges to both epidemiologists and toxicologists, particularly in cases of complex gene-environment interactions and when there is a long latency between exposure and disease. Biologic markers, physiological signals that reflect exposure, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Silbergeld EK,Davis DL

    更新日期:1994-07-01 00:00:00

  • Chemical and immunochemical measurement of total iron-binding capacity compared.

    abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buffone GJ,Lewis SA,Iosefsohn M,Hicks JM

    更新日期:1978-10-01 00:00:00

  • Correlation between estrogen receptor protein and carcinoembryonic antigen in normal and carcinomatous human breast tissue.

    abstract::We determined estrogen receptor protein and carcinoembryonic antigen in cytosols prepared from 189 human breast carcinoma tissues, 85 benign or normal breast biopsies, and 101 tissue specimens metastatic from breast carcinoma. Carcinoembryonic antigen was observed in 70% of the primary carcinomatous tissues, 15% of th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Menendez-Botet CJ,Nisselbaum JS,Fleisher M,Rosen PP,Fracchia A,Robbins G,Urban JA,Schwartz MK

    更新日期:1976-08-01 00:00:00