Abstract:
:We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. the instrument is computer controlled. We compared it with the Technicon SMAC, SMA 12/60, and SMA 6/60. It demonstrated excellent precision, linearity, lack of interference, ease of operation, and satisfactory comparison with values obtained by the Technicon methods.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Robinson CA,Proelss H,Stabler TVsubject
Has Abstractpub_date
1982-01-01 00:00:00pages
105-9issue
1eissn
0009-9147issn
1530-8561journal_volume
28pub_type
杂志文章abstract::We describe estimation of total cortisol in serum by HPLC. Incorporation of a new technique to totally automate sample preparation decreases costs. The benefits of HPLC ensure that interferences from other steroids are avoided. The method can also be used to estimate concentrations of other glucocorticoids in serum. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-09-01 00:00:00
abstract::We describe a two-site time-resolved immunofluorometric assay for guinea pig vascular permeability factor (VPF) for quantifying VPF in different biological fluids. Antibody against the carboxy terminus (C-IgG) is immobilized on microtiter wells, and antibody against the amino terminus (N-IgG) is labeled with Eu(3+)-ch...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-01-01 00:00:00
abstract::We have developed an automated latex agglutination test for Treponema pallidum (TPLA) for measurement of the concentration of treponemal antibodies in syphilitic sera. The assay needs neither a complicated pretreatment of the sera nor special techniques. Intra- and interassay precision studies showed high reproducibil...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-08-01 00:00:00
abstract::An optimized assay for alkaline phosphatase (EC 3.1.3.1) is reported. A discrete analyzer, the DuPont Automatic Clinical Analyzer (aca), was used for this study. The assay is based on results of response-surface experimental co-optimization techniques, and response is enhanced over the present aca assay. A key feature...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-07-01 00:00:00
abstract::Two-dimensional electroimmunodiffusion is rarely used in clinical chemistry, because its potentialities are not yet widely appreciated. Studying mouse anaphylaxis, we observed with this technique certain striking short- and long-term pathologic changes in several important serum antigens, which aptly demonstrate its u...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-05-01 00:00:00
abstract::In routine analysis for immunoglobulin light chains in pediatric diagnostics, the age-related reference intervals for serum kappa (kappa) and lambda (lambda) light chains were evaluated in 1543 healthy subjects (newborns to age 16 years, including 168 premature infants). Light-chain analysis was performed by rate neph...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-04-01 00:00:00
abstract::We assessed several methods of inorganic phosphate assay for their suitability in estimating phospholipids in digested extracts of amniotic fluids. The extraction and digestion procedures used for phospholipids from amniotic fluid were also examined critically. The effect of contamination by blood or obstetric cream h...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-09-01 00:00:00
abstract::We studied the effect of lyophilization of serum pools on the determination of cholesterol with the enzymatic methods used in five automated analyzers: SMAC (Technicon), the RA-1000 (Technicon), the aca (Du Pont), the TDx (Abbott), and the Ektachem 700P (Kodak). We prepared two serum pools: pool A (2.2 g/L) and pool B...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-07-01 00:00:00
abstract::We describe a procedure based on equilibrium dialysis that allows the simultaneous determination of free testosterone and testosterone bound to non-sex-hormone-binding globulin (non-SHBG) in plasma. After saturating SHBG with 5 alpha-dihydrotestosterone (DHT) according to a technique recently described, the percentage...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-06-01 00:00:00
abstract::We describe a group of glycoproteins that are synthesized and released by human breast tumors maintained in organ culture and similar glycoproteins released by a human breast carcinoma cell line (BT-20). The electrophoretic mobility of these glycoproteins on cellulose acetate is consistent with increased glycoprotein-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-11-01 00:00:00
abstract:BACKGROUND:It is important that cardiac troponin be measured accurately with a robust method to limit false results with potentially adverse clinical outcomes. In this study, we characterized the robustness of 4 analytical platforms by measuring the outlier rate between duplicate results. METHODS:We measured cardiac t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.159830
更新日期:2011-05-01 00:00:00
abstract::We modified a one-step, two-site, double monoclonal immunoenzymometric assay (Abbott Laboratories) for serum alpha1-fetoprotein (AFP) to increase its sensitivity and improve test precision at the low end. We increased sample size, incubation interval, and reaction time and temperature, and decreased the final reaction...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-04-01 00:00:00
abstract:BACKGROUND:The 2447 A > T pathogenic variation at codon 816 of exon 17 (D816V) in the KIT gene, occurring in systemic mastocytosis (SM), leads to constitutive activation of tyrosine kinase activity and confers resistance to the tyrosine kinase inhibitor imatinib mesylate. Thus detection of this variation in SM patients...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.068205
更新日期:2006-12-01 00:00:00
abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-02-01 00:00:00
abstract:BACKGROUND:We describe a simple tetra-primer amplification refractory mutation system PCR (T-ARMS-PCR) for detecting MUTYH mutations, which are associated with colorectal adenomas and colorectal cancer. METHODS:We designed specific T-ARMS-PCR assays for 6 mutations (Y165C, G382D, 1395_7delGGA, Y90X, 1103delC, and R231...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.060137
更新日期:2006-04-01 00:00:00
abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract::A gas-chromatographic method for urinary organic acid analysis is described, designed to be used routinely for the diagnosis of organic aciduria. It involves extraction of urine with ethyl acetate, dehydration of extract residues, and trimethylsilylation. Organic acids are identified by using an extensive list of rete...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-12-01 00:00:00
abstract:BACKGROUND:Galectin-3 has emerged as a potential useful novel biomarker for heart failure and cardiovascular disease (CVD). However, it remains unclear whether galectin-3 is associated with recurrent cardiovascular events during long-term follow-up of patients with stable coronary heart disease (CHD) after adjustment f...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.257550
更新日期:2016-10-01 00:00:00
abstract::We measured the day-to-day variations in concentrations of beta-core, luteinizing hormone (LH), and alpha-subunit in urine during the menstrual cycle. The alpha-subunit concentrations showed a pattern similar to that of the LH concentrations. beta-Core-like material was increased during and up to 3 to 4 days after the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract::Detection and characterization of small IgM paraproteins by immunoelectrophoresis are often difficult because of (a) slow diffusion of the macromolecular immunoglobulin, and (b) the obscuring of the light chain, especially kappa, by the light chains of background polyclonal immunoglobulin (the "umbrella effect"). Vari...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-08-01 00:00:00
abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-08-01 00:00:00
abstract::A total of 1357 polypeptides [946 acidic (isoelectric focusing) and 411 basic (nonequilibrium pH-gradient electrophoresis)] from human HeLa cells have been separated and catalogued with use of high-resolution two-dimensional gel electrophoresis. Of these polypeptides, 1266 were detected by labeling cells with [35S]met...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract:BACKGROUND:Recent recognition of its broad pathophysiological importance has triggered an increased interest in 25-hydroxyvitamin D [25(OH)D]. By consequence, throughput in 25(OH)D testing has become an issue for clinical laboratories, and several automated assays for measurement of 25(OH)D are now available. The aim o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.176545
更新日期:2012-03-01 00:00:00
abstract:BACKGROUND:Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration wi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.282665
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Human herpesvirus 6 (HHV-6) latently infects a majority of adults. In about 1% of the population HHV-6 exists in a chromosomally integrated form (ciHHV-6) that resides in every somatic and germ cell and can be transmitted through the germ line. Patients with ciHHV-6 have been misdiagnosed and unnecessarily t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.217240
更新日期:2014-05-01 00:00:00
abstract::We describe a single-cuvette enzyme-linked immunosorbent assay (ELISA) based on enzymic rate kinetics. This kinetic assay can yield linear quantitative data on immunoglobin concentrations. Optimum assay conditions, component concentrations, reaction intervals, and pH are described. Assay linearity and sensitivity are ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-08-01 00:00:00
abstract:BACKGROUND:Reports of the use of multiplex enzyme assay screening for Pompe disease, Fabry disease, Gaucher disease, Niemann-Pick disease types A and B, and Krabbe disease have engendered interest in the use of this assay in newborn screening. We modified the assay for high-throughput use in screening laboratories. ME...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.104711
更新日期:2008-10-01 00:00:00
abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-12-01 00:00:00
abstract::To determine the molar absorptivities of beta-NADH and beta-NAD at 260 nm, we purified the reduced form of the coenzyme by repeated anion-exchange chromatography. A NADH preparation was so obtained for which the 260 nm/340 nm absorbance ratio was 2.265. When calculated with epsilon 340 beta-NADH = 6.22 times 10-3 for ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-06-01 00:00:00
abstract:BACKGROUND:A previously developed monoclonal/polyclonal ELISA (Mono/Poly) to detect plasma concentrations of osteopontin (OPN) was shown to provide prognostic information in breast, prostate, and other cancers. Here we describe the clinical validation of a new dual monoclonal (Dual Mono) assay. We compared both assays ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.117465
更新日期:2009-05-01 00:00:00