Gas-chromatographic method of analysis for urinary organic acids. II. Description of the procedure, and its application to diagnosis of patients with organic acidurias.

Abstract:

:A gas-chromatographic method for urinary organic acid analysis is described, designed to be used routinely for the diagnosis of organic aciduria. It involves extraction of urine with ethyl acetate, dehydration of extract residues, and trimethylsilylation. Organic acids are identified by using an extensive list of retention indices published in the accompanying paper (this issue). Quantitative values are given for organic acids in urines from 50 ostensibly normal subjects. Typical chromatograms of urinary organic acids from patients with eight well-established organic acidurias are also shown.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Tanaka K,West-Dull A,Hine DG,Lynn TB,Lowe T

subject

Has Abstract

pub_date

1980-12-01 00:00:00

pages

1847-53

issue

13

eissn

0009-9147

issn

1530-8561

journal_volume

26

pub_type

杂志文章
  • Apolipoprotein B and A-I values in 147576 Swedish males and females, standardized according to the World Health Organization-International Federation of Clinical Chemistry First International Reference Materials.

    abstract::Serum concentrations of apolipoprotein (apo) B and apo A-I were measured from 1985-1996 in a Swedish population sample of 83 112 males and 64 464 females, ages <20 to >80 years, using an automated immunoturbidimetric method calibrated against fresh pools of human serum and commercial calibrators. All values were recal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jungner I,Marcovina SM,Walldius G,Holme I,Kolar W,Steiner E

    更新日期:1998-08-01 00:00:00

  • Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM.

    abstract::Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzym...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Steirteghem AC,Zweig MH,Schechter AN

    更新日期:1978-03-01 00:00:00

  • Automated measurement of alpha-amylase isoenzymes with 6(3)-deoxymaltotriose as selective amylase inhibitor.

    abstract::We developed an automated method for measurement of alpha-amylase isoenzymes in serum by a single kinetic assay (SKA) and a double kinetic assay (DKA) with 2-chloro-4-nitrophenyl-6(5)-azido-6(5)-deoxy-beta-maltopentaoside as a substrate and 6(3)-deoxymaltotriose (DOG3) as a novel selective amylase inhibitor. DOG3 show...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Uchida R,Tokutake S,Motoyama Y,Hosoi K,Yamaji N

    更新日期:1995-04-01 00:00:00

  • Photodiode array detection for liquid chromatographic profiling of carboxylic acids in physiological fluids: 3-hydroxy-3-methylglutaric aciduria.

    abstract::3-Hydroxy-3-methylglutaric aciduria was detected in a newborn. The progress of the dietary therapy for the disorder was monitored by dual-column "high-performance" liquid chromatography with a computer-controlled photodiode array spectrophotometric detector. This procedure is a quick way to detect and monitor the prog...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Buchanan DN,Thoene JG

    更新日期:1986-01-01 00:00:00

  • Glucocorticoid receptors in normal leukocytes: effects of age, gender, season, and plasma cortisol concentrations.

    abstract::We measured glucocorticoid receptors (GR) in mononuclear leukocytes (MNL) isolated from peripheral blood of 145 apparently healthy volunteers (86 men and 59 women). An age-related decrease in the number of GR was suggested between subjects younger than 20 years and elderly subjects; there was no apparent seasonal vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka H,Akama H,Ichikawa Y,Homma M,Oshima H

    更新日期:1991-10-01 00:00:00

  • Differential reactivity of two homogeneous LDL-cholesterol methods to LDL and VLDL subfractions, as demonstrated by ultracentrifugation and HPLC.

    abstract:BACKGROUND:The analytical and clinical performance of homogeneous LDL-cholesterol assays has been reported, but their reactions with subfractions of LDL and VLDL have not been described in detail. METHODS:We evaluated reaction selectivity of two homogeneous LDL-cholesterol assays, LDLk (Kyowa Medex) and LDLd (Daiichi ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Usui S,Kakuuchi H,Okamoto M,Mizukami Y,Okazaki M

    更新日期:2002-11-01 00:00:00

  • Clinical Correlations of Programmed Cell Death Ligand 1 Status in Liquid and Standard Biopsies in Breast Cancer.

    abstract:BACKGROUND:Data regarding the prognostic value of programmed cell death ligand 1 (PD-L1) expression on circulating tumor cells (CTCs) are lacking. However, CTCs could represent an alternative approach to serial biopsies, allowing real-time monitoring of cancer phenotype. METHODS:We evaluated, in a dedicated prospectiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa121

    authors: Jacot W,Mazel M,Mollevi C,Pouderoux S,D'Hondt V,Cayrefourcq L,Bourgier C,Boissiere-Michot F,Berrabah F,Lopez-Crapez E,Bidard FC,Viala M,Maudelonde T,Guiu S,Alix-Panabières C

    更新日期:2020-08-01 00:00:00

  • Five creatine kinase isoenzymes in serum of a patient with severe heart disease.

    abstract::Abnormal creatine kinase (CK) isoenzyme patterns were observed in the serum of a 64-year-old woman with severe heart disease. Agarose electrophoresis revealed the presence of all the usual CK isoenzymes (MM, MB, and BB) plus an extra band between MM and MB. Total serum CK activity was within the normal range. Within 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Csako G,Papadopoulos NM,Jett GK,McIntosh CL

    更新日期:1982-10-01 00:00:00

  • Determination of total cholesterol in serum by liquid chromatography-isotope dilution mass spectrometry.

    abstract::We have developed a liquid chromatography-isotope dilution mass spectrometry procedure to quantify total cholesterol in serum. A particle-beam interface was used for coupling the liquid chromatograph and the mass spectrometer. After electron impact ionization the ions m/z = 386 and m/z = 389 were used for selective io...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kock R,Delvoux B,Greiling H

    更新日期:1997-10-01 00:00:00

  • Applications of MALDI Mass Spectrometry in Clinical Chemistry.

    abstract:BACKGROUND:MALDI-TOF mass spectrometry (MS) is set to make inroads into clinical chemistry because it offers advantages over other analytical platforms. These advantages include low acquisition and operating costs, ease of use, ruggedness, and high throughput. When coupled with innovative front-end strategies and appli...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239491

    authors: Duncan MW,Nedelkov D,Walsh R,Hattan SJ

    更新日期:2016-01-01 00:00:00

  • Accuracy and comparability of long-term measurements of cholesterol.

    abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hainline A Jr,Karon JM,Winn CL,Gill JB

    更新日期:1986-04-01 00:00:00

  • Combi scheme: new combined internal/external quality-assessment scheme in The Netherlands.

    abstract::The Dutch Foundation for Quality Assessment in Clinical Chemistry (SKZL) is the professional organization that conducts external quality-assessment schemes in The Netherlands. However, such schemes in fact assess the performance of the internal quality-control systems of the participating laboratories. In this paper w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Steigstra H,Jansen RT,Baadenhuijsen H

    更新日期:1991-07-01 00:00:00

  • Biological variation of blood acid-base status: consequences for analytical goal-setting and interpretation of results.

    abstract::Analytical, intra-individual, and interindividual components of variation have been determined for pH, pCO2, bicarbonate, base excess, and total CO2 in capillary specimens of whole blood from a cohort of 14 healthy subjects. Calculated analytical goals (SD) are pH less than or equal to 0.008, pCO2 less than or equal t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harding PJ,Fraser CG

    更新日期:1987-08-01 00:00:00

  • Multi-wavelength analyses of second-derivative spectra for rapid determination of acetaminophen in serum.

    abstract::Measurement of acetaminophen by analysis of the second derivative of its spectrum is specific and sensitive. The method of extraction and the use of just one phosphate buffer as reagent makes this method very convenient. Readings are reliable from 10 to 1500 mg/L. A turnaround time of 20 min makes this method well sui...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dingeon B,Charvin MA,Quenard MT,Thome H

    更新日期:1988-06-01 00:00:00

  • Interlaboratory standardization of glycated hemoglobin determinations.

    abstract::As the clinical utility of glycated hemoglobin (gHb) measurement increases, so does the need for standardization of values between different methods and different laboratories. Using three different methods, we examined the feasibility of interlaboratory standardization of gHb measurement. A liquid-chromatographic (HP...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Little RR,England JD,Wiedmeyer HM,McKenzie EM,Mitra R,Erhart PM,Durham JB,Goldstein DE

    更新日期:1986-02-01 00:00:00

  • Monoclonal antibody inhibiting creatine kinase MM3 but not isoform MM1.

    abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suzuki T,Shiraishi T,Tomita K,Totani M,Murachi T

    更新日期:1990-01-01 00:00:00

  • Lp-PLA2: a new kid on the block.

    abstract:BACKGROUND:Atherosclerosis is a systemic disease with focal rupture of vulnerable plaque responsible for major clinical events. Several population-based studies indicate an association between lipoprotein-associated phospholipase A2 (Lp-PLA2) and cardiovascular events. Lp-PLA2 is emerging as a biomarker that may be a p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.070672

    authors: Zalewski A,Nelson JJ,Hegg L,Macphee C

    更新日期:2006-09-01 00:00:00

  • SELDI-TOF MS whole serum proteomic profiling with IMAC surface does not reliably detect prostate cancer.

    abstract:BACKGROUND:The analysis of bodily fluids using SELDI-TOF MS has been reported to identify signatures of spectral peaks that can be used to differentiate patients with a specific disease from normal or control patients. This report is the 2nd of 2 companion articles describing a validation study of a SELDI-TOF MS approa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2007.091496

    authors: McLerran D,Grizzle WE,Feng Z,Thompson IM,Bigbee WL,Cazares LH,Chan DW,Dahlgren J,Diaz J,Kagan J,Lin DW,Malik G,Oelschlager D,Partin A,Randolph TW,Sokoll L,Srivastava S,Srivastava S,Thornquist M,Troyer D,Wright GL

    更新日期:2008-01-01 00:00:00

  • Effect of stripping thyroxin from thyroxin-binding globulin on the measurement of free thyroxin in serum by equilibrium dialysis and by radioimmunoassay.

    abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakagawa T,Matsumura K,Takeda K,Shinoda N,Matsuda A,Matsushita T,Tagami T

    更新日期:1990-02-01 00:00:00

  • Evaluating the impact of exposure to environmental contaminants on human health.

    abstract::Humans are exposed daily to low concentrations of many different chemical substances, natural and some man-made. Although many of these substances can be toxic at high levels, typical exposures are far below the effect levels. The responses produced by man-made aromatic hydrocarbon receptor agonists, such as dioxins, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Silkworth JB,Brown JF Jr

    更新日期:1996-08-01 00:00:00

  • The haptoglobin 2-2 phenotype affects serum markers of iron status in healthy males.

    abstract:BACKGROUND:Human iron status is influenced by environmental and genetic factors. We hypothesized that the genetic polymorphism of haptoglobin (Hp), a hemoglobin-binding plasma protein, could affect iron status. METHODS:Reference values of serum iron status markers were compared according to Hp phenotypes (Hp 1-1, Hp 2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Langlois MR,Martin ME,Boelaert JR,Beaumont C,Taes YE,De Buyzere ML,Bernard DR,Neels HM,Delanghe JR

    更新日期:2000-10-01 00:00:00

  • Micro-scale method for theophylline in body fluids by reversed-phase, high-pressure liquid chromatography.

    abstract::We describe a micro-scale method for determining serum theophylline. The chromatography system includes a muBondapack C18 column and acetonitrile, 70 ml/liter of sodium acetate buffer (10 mmol/liter, ph 4.0) as the mobile phase. Test serum or plasma, 30 mul, is mixed with an equal quantity of a solution containing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Orcutt JJ,Kozak PP Jr,Gillman SA,Cummins LH

    更新日期:1977-03-01 00:00:00

  • Corin is present in the normal human heart, kidney, and blood, with pro-B-type natriuretic peptide processing in the circulation.

    abstract:BACKGROUND:B-type natriuretic peptide (BNP), which is activated in heart failure (HF), is processed to an active form by corin. The corin gene is expressed in the human heart and kidney, but corin protein expression in the heart, kidney, and circulation, along with whether proBNP is processed by circulating corin, rema...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.153908

    authors: Ichiki T,Huntley BK,Heublein DM,Sandberg SM,McKie PM,Martin FL,Jougasaki M,Burnett JC Jr

    更新日期:2011-01-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ

    更新日期:1994-06-01 00:00:00

  • Faster determination of clottable fibrinogen in human plasma: an improved method and kinetic study.

    abstract::Clottable fibrinogen in human plasma was determined by measuring spectrophotometrically the increase in turbidity with time due to the fibrinogen-fibrin conversion with thrombin. From the maximal absorbance, Amax, at 450 nm obtained 2 min or less after thrombin as added to plasma, we estimated the fibrinogen concentra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Inada Y,Okamoto H,Kanai S,Tamaura Y

    更新日期:1978-02-01 00:00:00

  • Analyzing quality-control trends with moving slope charts.

    abstract::We have developed and evaluated a new procedure for detecting trends in quality-control measurements and applied it to laboratory data. The method requires the use of sequential or "moving" slope estimates to identify trends. Formulae are derived to estimate the regression error for the moving slope directly from the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Smith SJ,Myers GL

    更新日期:1991-03-01 00:00:00

  • Highly specific radioimmunoassay for human insulin based on immune exclusion of all insulin precursors.

    abstract::We describe a rapid and simple insulin RIA in which proinsulin and conversion intermediates do not interfere. Three monoclonal antibodies (S1, S2, and S53) were selected for their specificity (directed, respectively, against the B10 region, the junction between A chain and C-peptide, and the junction between B chain a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Deberg M,Houssa P,Frank BH,Sodoyez-Goffaux F,Sodoyez JC

    更新日期:1998-07-01 00:00:00

  • Identification of Males with Cryptic Fragile X Alleles by Methylation-Specific Quantitative Melt Analysis.

    abstract:BACKGROUND:FMR1 full mutations (FMs) (CGG expansion >200) in males mosaic for a normal (<45 CGG) or gray-zone (GZ) (45-54 CGG) allele can be missed with the standard 2-step fragile X syndrome (FXS) testing protocols, largely because the first-line PCR tests showing a normal or GZ allele are not reflexed to the second-l...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.244681

    authors: Aliaga SM,Slater HR,Francis D,Du Sart D,Li X,Amor DJ,Alliende AM,Santa Maria L,Faundes V,Morales P,Trigo C,Salas I,Curotto B,Godler DE

    更新日期:2016-02-01 00:00:00

  • Serum concentrations of cross-linked N-telopeptides of type I collagen: new marker for bone resorption in hemodialysis patients.

    abstract:BACKGROUND:Urinary cross-linked N-telopeptide of type I collagen (NTX) is a reliable bone resorption marker in patients with metabolic bone disease. We assessed a clinically available serum NTX assay suitable for anuric patients on hemodialysis (HD). METHODS:Serum concentrations of NTX, C-terminal telopeptide of type ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051524

    authors: Maeno Y,Inaba M,Okuno S,Yamakawa T,Ishimura E,Nishizawa Y

    更新日期:2005-12-01 00:00:00

  • Single-strand conformation polymorphism analysis to detect p53 mutations: characterization and development of controls.

    abstract::Single-strand conformation polymorphism (SSCP) analysis is widely used to prescreen mutations in p53 gene. However, standardization of SSCP to detect p53 mutations has rarely been pursued so far. We have developed complete conditions for a temperature-controlled nonradioactive SSCP for mutation detection in amplified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Welsh JA,Castrén K,Vähäkangas KH

    更新日期:1997-12-01 00:00:00