Abstract:
:As the clinical utility of glycated hemoglobin (gHb) measurement increases, so does the need for standardization of values between different methods and different laboratories. Using three different methods, we examined the feasibility of interlaboratory standardization of gHb measurement. A liquid-chromatographic (HPLC) system from our research laboratory was designated the reference method. For gHb standards we used erythrocyte hemolysates prepared from blood samples from nondiabetic and diabetic subjects. Values assigned to each standard were based on the mean of multiple gHb determinations by the HPLC method. A clinical laboratory routinely prepared hemolysates and assayed gHb by commercially available ion-exchange ("mini column") and affinity chromatographic methods. For each assay a standard curve was constructed and gHb values were derived from these curves. Samples analyzed in the clinical laboratory were also analyzed in the research laboratory and the curve-derived values were compared with the HPLC-measured values, to determine the accuracy of our interlaboratory standardization procedure. Correlations were excellent (r = 0.99). The lack of significant differences between calculated and HPLC-measured values indicates that interlaboratory standardization is feasible.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Little RR,England JD,Wiedmeyer HM,McKenzie EM,Mitra R,Erhart PM,Durham JB,Goldstein DEsubject
Has Abstractpub_date
1986-02-01 00:00:00pages
358-60issue
2eissn
0009-9147issn
1530-8561journal_volume
32pub_type
杂志文章abstract::The pattern of organic acids in urine from 15 normal newborn infants was investigated by gas chromatography/mass spectrometry of trimethylsilylated derivatives. The urine contains large amounts of succinic, fumaric, 2-ketoglutaric, and 3-hydroxy-3-methylglutaric acids, which are all fairly small components of urine fr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-01-01 00:00:00
abstract::We measured certain enzyme activities (aldolase, aspartate aminotransferase, creatine kinase, and lactate dehydrogenase) and inflammation markers (alpha 1-antitrypsin, C-reactive protein, fibrinogen, and leukocytes) each day for four days in plasma of patients with severe head injury. The univariate prognostic efficie...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-11-01 00:00:00
abstract::I describe the automation/mechanization of several areas of sample processing at SmithKline Beecham Clinical Laboratories. By analyzing and implementing new systems for conveyance and sorting of incoming specimens, specimen processing, within-laboratory specimen delivery, specimen storage and retrieval, and client res...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-09-01 00:00:00
abstract::This two-site immunoradiometric assay for human parathyrin-related protein 1-86 (PTHRP1-86) in plasma uses a mouse monoclonal antibody to PTHRP1-34 coupled to cellulose particles for immunoextraction of N-terminal immunoreactivity, and a rabbit antiserum to PTHRP37-67 that is indirectly labeled with 125I-labeled PTHRP...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-05-01 00:00:00
abstract::The use of 4-chlorotestosterone acetate by farmers for cattle fattening was recently demonstrated although the use of this anabolic steroid is strictly forbidden in the European Union. We investigated the metabolism of 4-chlorotestosterone acetate in the bovine species after intramuscular and oral administration. Nine...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-05-01 00:00:00
abstract::The measurement of glycohemoglobin (GHb) by boronate affinity chromatography is useful in monitoring long-term glucose control in diabetic subjects. The inherent disadvantage of this method is the hands-on time required because the hemoglobin fractions are separated on individual disposable columns. To overcome this d...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-01-01 00:00:00
abstract:BACKGROUND:Functional antibody surfaces were prepared on ultraflat polystyrene surfaces by physical adsorption, and the uniform distribution of monoclonal antibodies against hepatitis B surface antigen (anti-HBs) on such surfaces and the presence of dense hepatitis B surface antigen (HBsAg) particles captured by immobi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-09-01 00:00:00
abstract::The S-peptide and S-protein fragments of ribonuclease S (RNase S, no EC no. assigned) have been immobilized onto separate Sepharose gels via a "leash" of polycytidylic acid substrate. Each of these gels releases its RNase fragment when treated with the complementary enzyme fragment or with RNase A (EC 3.1.27.5), and t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract::To validate azotemic markers as an index for intradialytic changes in solute concentration, we compared eight solutes (pseudouridine, xanthine, hypoxanthine, peak 4, peak 5, p-hydroxyhippuric acid, indoxyl sulfate, and hippuric acid) with five classical azotemic markers (urea, creatinine, uric acid, phosphate, and pot...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-08-01 00:00:00
abstract::This paper compares a logistic curve and a mass-action curve in their ability to represent radioimmunoassay standard curves. A data base from 10 different assays is used in this comparison. Six of the 10 assays could be modeled equally well by either the logistic or the mass-action curve. In one case the mass-action c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-10-01 00:00:00
abstract:BACKGROUND:Stability of chemical speciation during sample handling and storage is a prerequisite to obtaining reliable results of trace element speciation analysis. There is no comprehensive information on the stability of common arsenic species, such as inorganic arsenite [As(III)], arsenate [As(V)], monomethylarsonic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-11-01 00:00:00
abstract::One currently observes many healthcare institutions rushing to reengineer and install information systems with the expectation of achieving enhanced efficiency, competitiveness, and, it is hoped, higher patient satisfaction resulting from timely, high-quality care. Unfortunately, information system concepts, design, a...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1995-09-01 00:00:00
abstract::We describe an enzyme-linked immunosorbent assay for determination of light-chain ratios for IgG, IgA, and IgM in serum. A commercial serum with known overall kappa and lambda concentrations was used as standard. To capture the respective immunoglobulins, we used antibodies to gamma, lambda and mu chains coated onto m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-03-01 00:00:00
abstract::Determination of zinc in blood plasma by flameless atomic absorption spectrometry is discussed, with particular reference to the protocol required for the successful use of the Varian-Techtron Carbon Rod Atomizer. Cup aging is shown to be an important factor in limiting the precision of this analytical technique and ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-04-01 00:00:00
abstract:BACKGROUND:Bilirubin has antioxidative and cytoprotective properties. Low plasma concentrations of bilirubin are reportedly associated with the development of coronary and cerebrovascular disease, and bilirubin concentrations are strongly correlated with the enzyme activity of the hepatic uridine diphosphate glucuronos...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2007.102046
更新日期:2008-05-01 00:00:00
abstract::Major discoveries have been made in the past few years on the structure and mode of biosynthesis of serum albumin. The complete amino acid sequence of this protein has been determined, and its covalent structure shown to be a single peptide chain grouped into a series of nine disulfide-bonded loops. These loops appear...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1977-01-01 00:00:00
abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-10-01 00:00:00
abstract::We report the presence of complexes between aspartate aminotransferase (AST, EC 2.6.1.1) and immunoglobulin (Ig) in the serum of a patient suffering from lung cancer with metastasis to the liver. After fractionation of the serum by gel filtration, AST-Ig complexes (AST-IgA, AST-IgG) were demonstrated by counterimmunoe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-02-01 00:00:00
abstract::The current debate on our healthcare system has focused primarily on the cost of care. Because of drastically rising costs and their burden on our economy, government and the private sector have developed many approaches to reduce these costs. Managed care, special contracting arrangements, and government fiat have al...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1995-05-01 00:00:00
abstract::This new assay procedure for diaphorase eliminates problems of high blank rates and nonlinear kinetics associated with other methods. The dye thiazolyl blue tetrazolium bromide is reduced in the presence of NADH and diaphorase to yield a colored formazan, which as maximum absorbance at 560 nm. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-12-01 00:00:00
abstract::Investigating the interference of danazol in testosterone radioimmunoassays, we measured serum testosterone concentrations in the serum of women receiving danazol, with three testosterone radioimmunoassay kits. All of these showed positive interference by danazol or its metabolites (or both). Values for testosterone o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract:BACKGROUND:Single-nucleotide polymorphisms (SNPs) in inflammation-related genes have been linked to an increased risk of ischemic stroke. Most of these SNP results have not been replicated, however, and metaanalyses of the effects of inflammation-related genes are rare. We investigated 49 SNPs in 34 genes previously re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.112151
更新日期:2009-01-01 00:00:00
abstract::A recent study has shown that an emission-excitation matrix could be used to provide a unique fingerprint for the selective identification and characterization of certain species of Pseudomonas. This paper describes the results of a systematic study of the variables that contribute to the uniqueness of the fingerprint...
journal_title:Clinical chemistry
pub_type: 历史文章,杂志文章
doi:
更新日期:1980-09-01 00:00:00
abstract:BACKGROUND:The liver is frequently subject to insult because of viral infection, alcohol abuse, or toxic chemical exposure. Extensive research has been conducted to identify blood markers that can better discern liver damage, but little progress has been achieved in clinical practice. Recently, circulating microRNAs (m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.147850
更新日期:2010-12-01 00:00:00
abstract::Monoclonal antibody CKM-G01 inhibited greater than 99% of the activity of porcine and human creatine kinase(CK)-MM isoenzyme purified from muscle. However, it inhibited only 54% of CK-MM in human serum. Chromatofocusing of serum CK-MM showed that CKM-G01 inhibited 100% of MM3 but not isoform MM1. CKM-G01 inhibited CK-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract::I describe a simple, single-tube batch fractionation procedure for separating MM and MB isoenzymes of creatine kinase on a macroporous strong anion exchanger (AG MP-1, Bio-Rad Laboratories). The isoenzymes can be separated in less than 3 min, with a resulting dilution of the serum with no more than an equal volume of ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-01-01 00:00:00
abstract::We investigated two techniques of immunoblotting--the Western blot and the dot blot--for use in detecting prostatic acid phosphatase (PAP, EC 3.1.3.2). We used polyclonal antisera to human PAP, produced in rabbits by hyperimmunization with purified PAP, and PAP-specific monoclonal antibodies in the immunoenzymatic pro...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-10-01 00:00:00
abstract::Six alpha-amylase (EC 3.2.1.1) isoenzymes have been resolved electrophoretically on cellulose acetate membranes in a discontinuous buffer system. The fastest migrating isoenzymes are of salivary origin (S1, S2, S3), the slower ones of pancreatic origin (P1, P2, P3). We determined the amylase isoenzyme distribution in ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-01-01 00:00:00
abstract:BACKGROUND:Measurement of purine and pyrimidine metabolites presents complex problems for separations currently performed by HPLC and thin-layer chromatography in clinical practice. We developed a novel capillary electrophoresis method for this purpose. METHODS:Separations were performed in 60 mmol/L borate-2-amino-2-...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-12-01 00:00:00
abstract::A method for determining platinum in biological materials by flameless atomic absorption spectrometry has been developed for use in pharmacological studies of platinum antitumor compounds. Tissue digests are analyzed in a heated graphite atomizer, with use of background correction and ramp temperature charring. We hav...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-07-01 00:00:00