Abstract:
:Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dynamics Inc.) could differentiate between 0.3 g/L (upper limit of normal) and 0.6 g/L urine glucose concentrations. "Tes-Tape" (Lilly) and "Diastix" (Ames) gave positive readings at 0.3 g/L; "Clinitest" (Ames) detected glucose only over 1 g/L. Analytical recovery of glucose was best, for all four products, between 1 and 2.5 g/L; Chemstrip uG was the most nearly accurate among the four. Between 5 and 20 g/L glucose concentrations, Tes-Tape, Diastix, and Clinitest tended to give falsely low results; the use of Chemstrip uG resulted in overestimates of concentration at 20 g of glucose per liter. Only Chemistrip uG and Clinitest (two-drop method) had linear ranges extending to 50 g/L; Chemstrip uG had better precision and accuracy at this concentration. Of the four products, Chemstrip uG had the lowest within-technologist and technologist-to-technologist random analytical errors. In method comparison on patients' samples, Chemstrip uG was significantly stronger in its association with the quantitative hexokinase method than was Diastix, Clinitest, or Tes-Tape.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Bandi ZL,Myers JL,Bee DE,James GPsubject
Has Abstractpub_date
1982-10-01 00:00:00pages
2110-5issue
10eissn
0009-9147issn
1530-8561journal_volume
28pub_type
杂志文章abstract:BACKGROUND:24,25-Dihydroxyvitamin D [24,25(OH)2D] in serum may be both a nuisance and nutritionally valuable. METHODS:We investigated the impact of 24,25(OH)2D3 on the performance of commercially available immunoassays for serum total 25-hydroxyvitamin D [25(OH)D] using (a) serum from a nationally representative sampl...
journal_title:Clinical chemistry
pub_type: 杂志文章,随机对照试验
doi:10.1373/clinchem.2014.234955
更新日期:2015-04-01 00:00:00
abstract::We have developed two methods for determining serum concentrations of felbamate, a new anticonvulsant drug. The first method is based on protein precipitation with acetonitrile, followed by HPLC. The between-run CV for this method is 5.7% (mean 55 mg/L), and the linearity extends from 5 to 175 mg/L. Results by this me...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-10-01 00:00:00
abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.052167
更新日期:2006-01-01 00:00:00
abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-04-01 00:00:00
abstract::We evaluated the enzymic mechanism by which 3-keto butylidene-beta-2-chloro-4-nitrophenyl maltopentaoside (3KB-G5-CNP) serves as a substrate for serum pancreatic (p-) and salivary (s-) amylases. In aliquots of the reaction mixture, three kinds of beta-2-chloro-4-nitrophenyl oligosaccharides (glucose, maltoside, and ma...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-08-01 00:00:00
abstract::6-thioguanine (6-TGN) and methyl 6-mercaptopurine nucleotides (Me6-MPNs) are the two major metabolites found in erythrocytes after administration of azathioprine. In an attempt to understand the role of these metabolites in the pharmacologic and toxic activity of thiopurines, we have developed a HPLC method for the si...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-03-01 00:00:00
abstract::This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other metho...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-02-01 00:00:00
abstract::We evaluated a new agarose-gel-electrophoretic procedure (Corning) (I) for separating and quantitating of high-density lipoprotein cholesterol (HDLC), comparing it with the modified Lipid Research Clinics (LRC) procedure (heparin 183 kilounits/L, MnCl2 92 mmol/L) (II). Method I was insensitive to an HDLC concentration...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-11-01 00:00:00
abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract::We examined the mechanism by which hypertriglyceridemia interferes with the Roche Diagnostics "Amylochrome" procedure for measurement of amylase in lactescent samples with normal and above-normal amylase activity. The serum blank recommended in the Amylochrome protocol to compensate for lactescence remains inappropria...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-10-01 00:00:00
abstract::We report microchromatographic measurement of fetal hemoglobin (HbF) proportions in a 36-year-old African-American multigravida woman. At 34 weeks she delivered a 630-g male infant who subsequently did well. Hemoglobin electrophoresis of the hemolysate revealed nearly 100% HbF without HbA, an extremely unusual natural...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-11-01 00:00:00
abstract::We determined the LD-1/LD-2 isoenzyme ratio in hemolysates of erythrocytes by electrophoresis on cellulose acetate and on agarose. A ratio exceeding 1.0 was found with the former but not the latter. Results were similar for in vitro models of hemolytic disorders. Using cellulose acetate electrophoresis, we determined ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-08-01 00:00:00
abstract::We evaluated a new discrete analyzer, the Hitachi 705. The instrument can process sequentially as many as 19 different enzymes or other analytes, with a throughput of 180 tests per hour. We evaluated the spectrophotometer, the sample and reagent probes, and the performance for 11 assays: creatine kinase, aspartate ami...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-04-01 00:00:00
abstract::We describe a process for preparing a cholesterol-rich lipoprotein extract from bovine serum. The material is used to enhance cholestrol concentration up to 3.5 g/liter in a clear control material from human serum. The optical clarity of the enriched serum is only slightly affected by lyophilization and reconstitution...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-08-01 00:00:00
abstract:BACKGROUND:Noninvasive prenatal diagnosis of monogenic disorders using maternal plasma and targeted massively parallel sequencing is being investigated actively. We previously demonstrated that comprehensive genetic diagnosis of a Duchenne muscular dystrophy (DMD) patient is feasible using a single targeted sequencing ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2014.236380
更新日期:2015-06-01 00:00:00
abstract:BACKGROUND:The next-generation, high-sensitivity cardiac troponin assays can measure quantifiable concentrations of cTn in a majority of individuals, but there are few studies assessing these assays for risk stratification. The present study was undertaken to determine if a research hs-cTnI assay can be useful for pred...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.127241
更新日期:2009-10-01 00:00:00
abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-05-01 00:00:00
abstract::We have developed a succinyldicholine-based assay for serum cholinesterase (EC 3.1.1.8) to help establish whether patients with suspected sensitivity to drugs of this type have enzyme abnormalities that cannot be detected by conventional laboratory techniques. Although the method discriminates between cholinesterase a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-08-01 00:00:00
abstract::We examined the relationship in a large-living population between the concentration of triglycerides in plasma from fasting persons and the concentration of very-low-density lipoprotein cholesterol (VLDL-C) as determined after preparative ultracentrifugation. Data from individuals in the Framingham Heart Study who wer...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-12-01 00:00:00
abstract::An oligonucleotide "melting" procedure was developed whereby we can monitor for a sequence heterogeneity in the gene for apolipoprotein E production. Two oligonucleotides were synthesized, one recognizing the common epsilon 3 allele but not the common epsilon 2 allele, the other recognizing the epsilon 2 allele but no...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-07-01 00:00:00
abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:BACKGROUND:Although numerous lateral flow immunoassays (LFIAs) have been developed and widely used, inadequate analytical sensitivity and the lack of multiple protein detection applications have limited their clinical utility. We developed a new LFIA device for the simultaneous detection of high-sensitivity cardiac tro...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.171694
更新日期:2011-12-01 00:00:00
abstract::We have improved the protocol for RNA quantification by using RNase protection. Instead of precipitation and extraction with phenol and chloroform, we use a faster and more reliable precipitation based on guanidinium thiocyanate (GdSCN). The internal standard is produced by in vitro transcription of a DNA template con...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-11-01 00:00:00
abstract::We measured immunoglobulins in the sera of 33 patients on days 1, 3, 6, 10, and 17 and three to four weeks after surgical operations (mostly hysterectomy or appendectomy) or (six patients) after spinal injury. In the absence of infection or blood transfusion, IgG usually decreased slightly and transiently after hyster...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2011.173856
更新日期:2012-04-01 00:00:00
abstract::To establish optimum conditions for creatine kinase (EC 2.7.3.2) activity measurement with the creatine phosphate in equilibrium creatine reaction, we re-examined all kinetics factors relevant to an optimal and standardized enzyme assay at 30 and 25 degrees C. We determined the pH optimum in vaious buffers, considerin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-05-01 00:00:00
abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.268656
更新日期:2017-05-01 00:00:00
abstract::We evaluated the analytical performance of new estradiol and progesterone assays performed on the Bayer Immuno 1 system. Within-run and between-day CVs for estradiol at concentrations of 116.8-6645.8 pmol/L were < or = 6.4% and for 5.54-103.95 nmol/L progesterone were < or = 7.7%, thus meeting published analytical goa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-09-01 00:00:00
abstract::This one-dimensional thin-layer chromatographic method is used for assay of phospholipids in the gastric aspirate of newborns. The solvent mixture (chloroform/hexane/methanol/glacial acetic acid/water, 12/7/4/3/0.3 by vol) completely resolves lecithin, sphingomyelin, phosphatidylinositol, phosphatidylserine, phosphati...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-04-01 00:00:00
abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00