Lithium determinations evaluated in eight analyzers.

Abstract:

:We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by drugs (procainamide, N-acetylprocainamide, quinidine, lidocaine, carbamazepine, and valproic acid) and inorganic analytes (Na, K, Ca, Mg, and Br), and performance with sera from patients receiving lithium. Imprecision was < 5% (CV) for all analyzers except Ektachem and Beckman. Analytical recovery was 100% +/- 5% for all analyzers except Ektachem and Baxter. Some drug interference was seen with all analyzers except AVL and Corning. Calcium caused interference with AVL, Corning, and Ektachem analyzers, and sodium and potassium interfered with the Ektachem analyzer. The results with the Baxter, Beckman, and Corning analyzers were closest to those by flame atomic emission (mean differences, 0.01 to 0.02 mmol/L); the AVL and Nova analyzers gave lower results (mean differences, -0.11 to -0.13 mmol/L) and the Ektachem gave higher results (mean difference, 0.08 mmol/L).

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Sampson M,Ruddel M,Elin RJ

subject

Has Abstract

pub_date

1994-06-01 00:00:00

pages

869-72

issue

6

eissn

0009-9147

issn

1530-8561

journal_volume

40

pub_type

杂志文章
  • Reagent-free, simultaneous determination of serum cholesterol in HDL and LDL by infrared spectroscopy.

    abstract:BACKGROUND:The purpose of this study was to assess the feasibility of infrared (IR) spectroscopy for the simultaneous quantification of serum LDL-cholesterol (LDL-C) and HDL-cholesterol (HDL-C) concentrations. METHODS:Serum samples (n = 90) were obtained. Duplicate aliquots (5 microL) of the serum specimens were dried...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Liu KZ,Shaw RA,Man A,Dembinski TC,Mantsch HH

    更新日期:2002-03-01 00:00:00

  • Influence of O.C.T. embedding compound on determinations of estrogen and progestin receptors in breast cancer.

    abstract::Estrogen receptor (ER) and progestin receptor (PR) concentrations in tumor biopsies are important predictive indicators of a clinical response to endocrine therapy of breast cancer. To assess interference of O.C.T. (optimum cutting temperature) embedding compound in assays of ER and PR by radioligand binding, we deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pasic R,Djulbegovic B,Wittliff JL

    更新日期:1989-12-01 00:00:00

  • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures.

    abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.173856

    authors: Hoofnagle AN,Becker JO,Oda MN,Cavigiolio G,Mayer P,Vaisar T

    更新日期:2012-04-01 00:00:00

  • Comparison of LDL cholesterol concentrations by Friedewald calculation and direct measurement in relation to cardiovascular events in 27,331 women.

    abstract:BACKGROUND:National Cholesterol Education Program (NCEP) guidelines recommend development of direct assays for LDL cholesterol (LDL-C) measurement, but it is unclear how these assays compare with Friedewald calculation in predicting cardiovascular disease (CVD). METHODS:In a study of 27 331 healthy women with triglyce...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.117929

    authors: Mora S,Rifai N,Buring JE,Ridker PM

    更新日期:2009-05-01 00:00:00

  • Stabilized analysis of antidepressant drugs by solvent-recycled liquid chromatography: procedure and proposed resolution mechanisms for chromatography.

    abstract::In this efficient extraction and isocratic liquid-chromatographic procedure for measuring eight antidepressant drugs in serum (amoxapine, 8-hydroxyamoxapine, doxepin, desmethyldoxepin, imipramine, desipramine, amitriptyline, and nortriptyline), they are extracted from serum as a group by use of disposable solid-phase ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lensmeyer GL,Evenson MA

    更新日期:1984-11-01 00:00:00

  • Human prostate-specific glandular kallikrein is expressed as an active and an inactive protein.

    abstract::A polymorphism in the human prostate-specific glandular kallikrein (hKLK2) gene was described by direct sequencing (by PCR) of genomic DNAs isolated from prostatic cancer tissue, benign prostatic hyperplasia tissue, and blood leukocyte specimens. Results showed two forms of human prostate-specific glandular kallikrein...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herrala A,Kurkela R,Porvari K,Isomäki R,Henttu P,Vihko P

    更新日期:1997-02-01 00:00:00

  • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.

    abstract::We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bergqvist Y,Eckerbom S,Funding L

    更新日期:1984-03-01 00:00:00

  • Adaptation of a T3-uptake test and of radioimmunoassays for serum digoxin, thyroxine, and triiodothyronine to an automated radioimmunoassay system--"Centria".

    abstract::We report the adaptation of four radioassays to the prototype of an automated radioimmunoassay system ("Centria," Union Carbide). The system consists of three integrated modules: (a) an automated pipettor, which dispenses samples and reagents; (b) the key module, an incubator/separator, in which centrifugal force is u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ertingshausen G,Shapiro SI,Green G,Zborowski G

    更新日期:1975-08-01 00:00:00

  • Quantifying manganese in lymphocytes to assess manganese nutritional status.

    abstract::To clarify whether manganese nutritional status is better reflected by the manganese concentration in lymphocytes or in whole blood, we injected manganese solutions intravenously into manganese-deficient rats and determined manganese concentrations in lymphocytes, whole blood, and various tissues. The manganese concen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matsuda A,Kimura M,Kataoka M,Ohkuma S,Sato M,Itokawa Y

    更新日期:1989-09-01 00:00:00

  • Extracellular Vesicles Long RNA Sequencing Reveals Abundant mRNA, circRNA, and lncRNA in Human Blood as Potential Biomarkers for Cancer Diagnosis.

    abstract:BACKGROUND:Extracellular vesicles (EVs) contain a rich cargo of different RNA species with specialized functions and clinical applications. However, the landscape and characteristics of extracellular vesicle long RNA (exLR) in human blood remain largely unknown. METHODS:We presented an optimized strategy for exLR sequ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.301291

    authors: Li Y,Zhao J,Yu S,Wang Z,He X,Su Y,Guo T,Sheng H,Chen J,Zheng Q,Li Y,Guo W,Cai X,Shi G,Wu J,Wang L,Wang P,He X,Huang S

    更新日期:2019-06-01 00:00:00

  • Mycophenolic acid binding to human serum albumin: characterization and relation to pharmacodynamics.

    abstract::Mycophenolate mofetil, the prodrug form of the immunosuppressive agent mycophenolic acid (MPA), is currently in clinical trials evaluating its effectiveness in transplant recipients. In this study, we validated an ultrafiltration system for the reliable measurement of free MPA. Using this technique, we evaluated facto...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nowak I,Shaw LM

    更新日期:1995-07-01 00:00:00

  • Standardization of C-peptide measurements.

    abstract:BACKGROUND:C-peptide is a marker of insulin secretion in diabetic patients. We assessed within- and between-laboratory imprecision of C-peptide assays and determined whether serum calibrators with values assigned by mass spectrometry could be used to harmonize C-peptide results. METHODS:We sent 40 different serum samp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2007.101287

    authors: Little RR,Rohlfing CL,Tennill AL,Madsen RW,Polonsky KS,Myers GL,Greenbaum CJ,Palmer JP,Rogatsky E,Stein DT

    更新日期:2008-06-01 00:00:00

  • Direct determination of plasma endothelin-I by chemiluminescence enzyme immunoassay.

    abstract::A highly sensitive sandwich-type chemiluminescence enzyme immunoassay for plasma endothelin-I (ET-1), involving no extraction steps, has been developed. Two populations of polyclonal antibodies were used in the present study: One is specific to the C-terminus of the endothelin family of peptides; the other, a Fab' fra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iwata R,Hayashi T,Nakao Y,Yamaki M,Yoshimasa T,Ito H,Saito Y,Mukoyam M,Nakao K

    更新日期:1996-08-01 00:00:00

  • Role of biomarkers in identifying and understanding environmentally induced disease.

    abstract::Establishing associations between environmental agents and disease presents challenges to both epidemiologists and toxicologists, particularly in cases of complex gene-environment interactions and when there is a long latency between exposure and disease. Biologic markers, physiological signals that reflect exposure, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Silbergeld EK,Davis DL

    更新日期:1994-07-01 00:00:00

  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • Ghrelin, leptin, IGF-1, IGFBP-3, and insulin concentrations at birth: is there a relationship with fetal growth and neonatal anthropometry?

    abstract:BACKGROUND:Insulin, growth hormone (GH), and growth factors (insulin-like growth factors [IGFs] and their binding proteins [IGFBPs]) are known to influence fetal growth and also the synthesis/secretion of the recently discovered hormones leptin and ghrelin. METHODS:In 153 delivering mothers and their offspring at birt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.095299

    authors: Chiesa C,Osborn JF,Haass C,Natale F,Spinelli M,Scapillati E,Spinelli A,Pacifico L

    更新日期:2008-03-01 00:00:00

  • Relation of lipoprotein(a) in 11- to 19-year-old adolescents to parental cardiovascular heart disease.

    abstract::We studied several risk factors in relation to parental cardiovascular heart disease: total cholesterol, triglycerides, high-density lipoprotein (HDL) cholesterol, low-density lipoprotein (LDL) cholesterol, apolipoprotein (apo) A-I, apo B, and lipoprotein(a) [Lp(a)] were determined in 322 serum samples (43 from subjec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vella JC,Jover E

    更新日期:1993-03-01 00:00:00

  • How many mistakes, how to find them.

    abstract::The topic of quality control often evokes prolific discussion among those whose business is its administration. Reliable methods for identifying mistakes must be developed in both the manufacture and use of test devices. Unit test devices are uncomplicated to run and provide quick results in a world where speed and si...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Blase AB

    更新日期:1997-05-01 00:00:00

  • Improved interassay correlation of digoxin results in patients with and without renal failure by elimination of digoxin-like immunoreactive factors.

    abstract::Use of immunoassays that do not detect endogenous digoxin-like immunoreactive factors (DLIF) in serum significantly improves the between-assay correlation of digoxin results for patients. We investigated five different immunoassay methods (Abbott, Clinical Assays, Corning, Du Pont, and Syva), measuring digoxin by all ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skogen WF,Rea MR,Valdes R Jr

    更新日期:1987-06-01 00:00:00

  • Profiling plasma microRNA in nasopharyngeal carcinoma with deep sequencing.

    abstract:BACKGROUND:The goal of this study was to establish a plasma microRNA profile by use of next-generation sequencing that could aid in assessment of patient prognosis in nasopharyngeal carcinoma (NPC). METHODS:Two panels of NPC patients and healthy controls (HCs) were recruited for this study. We used deep sequencing to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.214213

    authors: Wang HY,Yan LX,Shao Q,Fu S,Zhang ZC,Ye W,Zeng YX,Shao JY

    更新日期:2014-05-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Bilirubin binding by primary sites of human serum albumin, with suppression of secondary-site interference by use of a high salt concentration.

    abstract::A high (2.0 mol/L) NaCl concentration apparently suppresses the secondary-site binding of bilirubin by human serum albumin. Thus if an excess of bilirubin is added to human serum albumin or to neonatal serum in buffer containing 0.1 mol of tris(hydroxymethyl)aminomethane and 2.0 mol of NaCl per liter (pH 7.5), and the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rutkowski RB

    更新日期:1980-01-01 00:00:00

  • "Ultrasensitive" silver stains: their use exemplified in the study of normal human cerebrospinal fluid proteins separated by two-dimensional electrophoresis.

    abstract::We have developed a series of photochemical silver stains that are more than 100 times as sensitive as the Coomassie Blue stains. These stains facilitate the quantitative estimation of proteins in two-dimensional gel patterns. Recently, we discovered that by using light (photodevelopment) to catalyze the reduction of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Merril CR,Harrington MG

    更新日期:1984-12-01 00:00:00

  • Evaluation of the IFCC-recommended procedure for serum aspartate aminotransferase as modified for use with the centrifugal analyzer.

    abstract::The IFCC-recommended procedure for aspartate aminotransferase (EC 2.6.1.1) was adapted to the centrifugal analyzer and evaluated during five years. The main hindrance to widespread use of the recommended method is the need for pre-incubation with pyridoxal phosphate. The present method includes a 10-min pre-incubation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Savory J,Titheradge AC,Cross RE,Wills MR

    更新日期:1981-01-01 00:00:00

  • Optimized liquid-chromatographic method for fluorometric determination of urinary delta-aminolevulinic acid in workers exposed to lead.

    abstract::We developed a fluorometric method for determining delta-aminolevulinic acid (ALA) in urine of lead workers. A high-performance liquid chromatograph (HPLC) equipped with a fluorescence HPLC monitor is used. The detection limit for aqueous ALA is 20 micrograms/L (15 pmol of ALA in the 100-microL sample). The working li...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tomokuni K,Ichiba M,Hirai Y,Hasegawa T

    更新日期:1987-09-01 00:00:00

  • Kinetics of the reactions of unconjugated and conjugated bilirubins with p-diazobenzenesulfonic acid.

    abstract::We report the kinetics of the reactions of unconjugated bilirubin and conjugated bilirubin with p-diazobenzene sulfonic acid in aqueous media. Our studies confirm that each reaction proceeds in two steps and that the second step is catalyzed by sulfanilic acid. In the presence of an excess of p-diazobenzenesulfonic ac...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Landis JB,Pardue HL

    更新日期:1978-10-01 00:00:00

  • Cardiac troponin-I is not expressed in fetal and healthy or diseased adult human skeletal muscle tissue.

    abstract::Cardiac troponin-I (cTnI) is not found in sera of patients with skeletal muscle disease in the absence of myocardial injury. It is not known, however, whether trace amounts of cTnI are expressed in regenerating human skeletal muscle, as has been observed with creatine kinase MB. Using immunohistochemical and biochemic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bodor GS,Porterfield D,Voss EM,Smith S,Apple FS

    更新日期:1995-12-01 00:00:00

  • Gas-chromatographic determination of 5-fluorocytosine in human serum.

    abstract::We describe a sensitive and precise gas-chromatographic method, in which cytosine is used as the internal standard, for determination of an antifungal agent, 5-fluorocytosine, in serum. The trimethylsilyl derivative of this drug is well separated from the internal standard and from normal serum constituents. Amphoteri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harding SA,Johnson GF,Solomon HM

    更新日期:1976-06-01 00:00:00

  • Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

    abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garber CC

    更新日期:1981-08-01 00:00:00

  • A parallel revolution: payment for new in vitro diagnostic technologies.

    abstract::To secure a successful product in today's era of cost containment, manufacturers and developers of new in vitro diagnostic technologies must consider payment issues--coverage and reimbursement by healthcare insurers--as critical market forces that must be addressed in the business plan. Similar to the regulatory hurdl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ivor LP

    更新日期:1996-09-01 00:00:00