Reagent-free, simultaneous determination of serum cholesterol in HDL and LDL by infrared spectroscopy.

Abstract:

BACKGROUND:The purpose of this study was to assess the feasibility of infrared (IR) spectroscopy for the simultaneous quantification of serum LDL-cholesterol (LDL-C) and HDL-cholesterol (HDL-C) concentrations. METHODS:Serum samples (n = 90) were obtained. Duplicate aliquots (5 microL) of the serum specimens were dried onto IR-transparent barium fluoride substrates, and transmission IR spectra were measured for the dry films. In parallel, the HDL-C and LDL-C concentrations were determined separately for each specimen by standard methods (the Friedewald formula for LDL-C and an automated homogeneous HDL-C assay). The proposed IR method was then developed with a partial least-squares (PLS) regression analysis to quantitatively correlate IR spectral features with the clinical analytical results for 60 randomly chosen specimens. The resulting quantification methods were then validated with the remaining 30 specimens. The PLS model for LDL-C used two spectral ranges (1700-1800 and 2800-3000 cm(-1)) and eight PLS factors, whereas the PLS model for HDL-C used three spectral ranges (800-1500, 1700-1800, and 2800-3500 cm(-1)) with six factors. RESULTS:For the 60 specimens used to train the IR-based method, the SE between IR-predicted values and the clinical laboratory assays was 0.22 mmol/L for LDL-C and 0.15 mmol/L for HDL-C (r = 0.98 for LDL-C; r = 0.91 for HDL-C). The corresponding SEs for the test spectra were 0.34 mmol/L (r = 0.96) and 0.26 mmol/L (r = 0.82) for LDL-C and HDL-C, respectively. The precision for the IR-based assays was estimated by the SD of duplicate measurements to be 0.11 mmol/L (LDL-C) and 0.09 mmol/L (HDL-C). CONCLUSIONS:IR spectroscopy has the potential to become the clinical method of choice for quick and simultaneous determinations of LDL-C and HDL-C.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Liu KZ,Shaw RA,Man A,Dembinski TC,Mantsch HH

subject

Has Abstract

pub_date

2002-03-01 00:00:00

pages

499-506

issue

3

eissn

0009-9147

issn

1530-8561

journal_volume

48

pub_type

杂志文章
  • Identification of alpha(1)-antitrypsin variants in plasma with the use of proteomic technology.

    abstract:BACKGROUND:Proteomic technology permits the investigation of genetic metabolic diseases at the level of protein expression. Changes in the expression, polypeptide structure, and posttranslational modification of individual proteins can be detected in complex mixtures of proteins. METHODS:We used high-resolution two-di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mills K,Mills PB,Clayton PT,Johnson AW,Whitehouse DB,Winchester BG

    更新日期:2001-11-01 00:00:00

  • Human urinary arsenic excretion after one-time ingestion of seaweed, crab, and shrimp.

    abstract::We studied chemical speciation of arsenic compounds in urine samples by using HPLC with inductively coupled plasma mass spectrometry detection. We examined urinary arsenic excretion patterns and the arsenic species excreted from nine human subjects who ingested seaweed products and crab (or shrimp). Fast urinary excre...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Le XC,Cullen WR,Reimer KJ

    更新日期:1994-04-01 00:00:00

  • Effect of weight loss on serum lipoprotein(a) concentrations in an obese population.

    abstract::To assess the distribution of serum concentrations of the atherogenic lipoprotein(a) [Lp(a)] in an obese population and the possible effects of weight reduction, we determined Lp(a) in 52 white, moderately obese subjects (16 men and 36 women). The subjects were participating in a weight-reduction program of diet, exer...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Corsetti JP,Sterry JA,Sparks JD,Sparks CE,Weintraub M

    更新日期:1991-07-01 00:00:00

  • Newborn screening for cystic fibrosis by use of a multiplex immunoassay.

    abstract:BACKGROUND:Since its beginnings, newborn screening for cystic fibrosis (CF) using an assay for immunoreactive trypsinogen (IRT) has been plagued by a high rate of false-positive results (screen positive, diagnosis negative), despite attempts to reduce this rate by use of altered cutoffs and second-tier DNA testing. IRT...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.132480

    authors: Lindau-Shepard BA,Pass KA

    更新日期:2010-03-01 00:00:00

  • Interference in a chromogenic alpha-amylase assay caused by dye-labeled oligosaccharide-induced precipitation of lipoprotein.

    abstract::We examined the mechanism by which hypertriglyceridemia interferes with the Roche Diagnostics "Amylochrome" procedure for measurement of amylase in lactescent samples with normal and above-normal amylase activity. The serum blank recommended in the Amylochrome protocol to compensate for lactescence remains inappropria...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wickus GG,Dukerschein RO,Pierce JR,Davis KD

    更新日期:1982-10-01 00:00:00

  • Changes in concentrations of C-reactive protein in serum after kidney or heart transplantation.

    abstract::C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly dep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Castellani W,Abbott LB

    更新日期:1986-04-01 00:00:00

  • Calorimetry of cholinesterase activity in serum.

    abstract::Cholinesterase activity in human serum was measured calorimetrically and compared to values obtained with the spectrophotometric method of Rappaport et al. [Clin. Chim. Acta 4, 227 (1959)]. The response of the calorimeter upon mixing serum with acetylcholine corresponded to the cholinesterase activity of the serum, th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: O'Farrell HK,Chattopadhyay SK,Brown HD

    更新日期:1977-10-01 00:00:00

  • P-selectin- and CD63-exposing platelet microparticles reflect platelet activation in peripheral arterial disease and myocardial infarction.

    abstract:BACKGROUND:Platelet-derived microparticles (PMPs) are generally considered a marker of platelet activation in cardiovascular disease. We studied the extent to which PMP subpopulations parallel platelet activation in vitro and in vivo. METHODS:Using flow cytometry, we analyzed PMP subpopulations from resting and activa...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.057414

    authors: van der Zee PM,Biró E,Ko Y,de Winter RJ,Hack CE,Sturk A,Nieuwland R

    更新日期:2006-04-01 00:00:00

  • Two-site immunoenzymometric assay for thyrotropin in dried blood samples on filter paper.

    abstract::We describe a sensitive, simple, and rapid two-site immunoenzymometric assay for thyrotropin in dried blood samples on filter paper, for use in screening for neonatal primary hypothyroidism. In this method, two dried-blood spots of 3 mm diameter (equivalent to about 5.4 microliter of blood) are incubated overnight wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miyai K,Ishibashi K,Kawashima M

    更新日期:1981-08-01 00:00:00

  • Evaluation and comparison of immunoinhibition and immunoprecipitation methods for differentiating MB and BB from macro forms of creatine kinase isoenzymes in patients and healthy individuals.

    abstract::We compared results for measurements of creatine kinase isoenzyme MB (CK-MB) by immunoinhibition vs immunoprecipitation, using sera from 53 normal healthy individuals, 55 patients with increased CK-MB associated with acute myocardial infarction, and 42 patients whose blood exhibited one or more abnormal forms of CK by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu AH,Bowers GN Jr

    更新日期:1982-10-01 00:00:00

  • Extended clinical trial and evaluation of glucose determination with the Eastman Kodak Ektachem GLU/BUN Analyzer.

    abstract::We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by this technique, by the FDA Proposed Class Standard glucose reference met...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Bandi ZL,Fuller JB,Bee DE,James GP

    更新日期:1981-01-01 00:00:00

  • Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

    abstract::Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore FM,Simpson D

    更新日期:1989-08-01 00:00:00

  • Evaluation of preanalytical variables associated with measurement of prothrombin fragment 1.2.

    abstract::We have used a monoclonal antibody-based ELISA for plasma prothrombin fragment 1.2 (F1.2) to establish appropriate sample collection and storage conditions for this biomarker of thrombin generation. F1.2 concentrations were not altered by exogenous factor Xa, thrombin, or thromboplastin if blood was collected by routi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Greenberg CS,Hursting MJ,Macik BG,Ortel TL,Kane WH,Moore BM

    更新日期:1994-10-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • Serum reference intervals and diagnostic ranges for free kappa and free lambda immunoglobulin light chains: relative sensitivity for detection of monoclonal light chains.

    abstract:BACKGROUND:The detection of monoclonal free light chains (FLCs) is an important diagnostic aid for a variety of monoclonal gammopathies and is especially important in light-chain diseases, such as light-chain myeloma, primary systemic amyloidosis, and light-chain-deposition disease. These diseases are more prevalent in...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Katzmann JA,Clark RJ,Abraham RS,Bryant S,Lymp JF,Bradwell AR,Kyle RA

    更新日期:2002-09-01 00:00:00

  • Plasma selenium concentrations in patients with euthyroid sick syndrome.

    abstract::We evaluated plasma selenium concentrations in patients with euthyroid sick syndrome express by low serum triiodothyronine (T3) concentrations. Selenium status in these patients was compared with that found in patients with both untreated and treated hypothyroidism. Selenium concentrations in plasma were significantly...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Daher R

    更新日期:1992-09-01 00:00:00

  • Associations between serum gamma-glutamyltransferase and apolipoproteins: relationships with hepatobiliary diseases.

    abstract::We studied the association between gamma-glutamyltransferase (GGT) and apolipoproteins A or B in serum of 42 patients with various hepatobiliary diseases. Binding of the enzyme to apolipoprotein A is not related to a clearly defined disease, but appears to be mainly influenced by the ratio of total cholesterol to GGT ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Artur Y,Wellman-Bednawska M,Jacquier A,Siest G

    更新日期:1984-08-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Overtraining in neural networks that interpret clinical data.

    abstract::Backpropagation neural networks are a computer-based pattern-recognition method that has been applied to the interpretation of clinical data. Unlike rule-based pattern recognition, backpropagation networks learn by being repetitively trained with examples of the patterns to be differentiated. We describe and analyze t...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:

    authors: Astion ML,Wener MH,Thomas RG,Hunder GG,Bloch DA

    更新日期:1993-09-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Theoretical aspects of one-point calibration: causes and effects of some potential errors, and their dependence on concentration.

    abstract::The potential errors of the one-point calibration technique are described mathematically. I examine the theoretical causes and effects of analytical errors in absorbance and of errors in determining calibration concentration, and discuss techniques for minimizing their impact. The dependence of these errors on the cal...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kemp GJ

    更新日期:1984-07-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

    abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cohen A,Hertz HS,Mandel J,Paule RC,Schaffer R,Sniegoski LT,Sun T,Welch MJ,White E 5th

    更新日期:1980-06-01 00:00:00

  • New enzymatic assay for glycohemoglobin.

    abstract:BACKGROUND:Previous methods to measure glycohemoglobin (GHb) have been time-consuming or imprecise; we therefore developed a new enzymatic assay for GHb. METHODS:Blood cells were first hemolyzed, and hemoglobin was digested with protease to yield fructosyl amino acid. Fructosyl amino acid oxidase acts on the fructosyl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.2.269

    authors: Sakurabayashi I,Watano T,Yonehara S,Ishimaru K,Hirai K,Komori T,Yagi M

    更新日期:2003-02-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Relationship of lipoprotein-associated phospholipase A₂ mass and activity with incident vascular events among primary prevention patients allocated to placebo or to statin therapy: an analysis from the JUPITER trial.

    abstract:BACKGROUND:Although lipoprotein-associated phospholipase A(2) (Lp-PLA(2)) levels are associated with cardiovascular events, Lp-PLA(2) is physically linked to LDL cholesterol (LDL-C). Whether measures of Lp-PLA(2) mass or activity continue to predict risk after LDL-C reduction by statin therapy is uncertain. METHODS:Lp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.180281

    authors: Ridker PM,MacFadyen JG,Wolfert RL,Koenig W

    更新日期:2012-05-01 00:00:00

  • Hemoglobin Görwihl [alpha2beta(2)5(A2)Pro-->Ala], an electrophoretically silent variant with impaired glycation.

    abstract:BACKGROUND:Some of the genetic variants of hemoglobin (Hb) and their chemically modified species are known to affect the measurement of Hb A(1c). The purpose of this study was to characterize Hb species in the blood sample of a 74-year-old German male with an exceptionally low Hb A(1c) value. METHODS:Hemolysates from ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.1.137

    authors: Bissé E,Schauber C,Zorn N,Epting T,Eigel A,Van Dorsselaer A,Wieland H,Kister J,Kiger L

    更新日期:2003-01-01 00:00:00

  • Radioimmunoassay of beta-endorphin in ventricular and lumbar cerebrospinal fluid.

    abstract::We describe a sensitive beta-endorphin (beta-EP) radioimmunoassay specific for beta-EP 1-31 applied to human ventricular and lumbar cerebrospinal fluid (CSF). Specificity was documented by reversed-phase HPLC of CSF pools. Simultaneous ventricular and lumbar CSF samples from 13 patients suspected of having normal-pres...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bach FW,Schmidt JF,Faber T

    更新日期:1992-06-01 00:00:00

  • Continuous-flow determination of dialyzable calcium in serum.

    abstract::We describe a procedure for measuring dialyzable calcium in 60 sera per hour with use of AutoAnalyzer (Technicon) modules. The serum is buffered, then dialyzed in a regular 6-inch (15-cm) dialysis block. A constant proportion of the dialyzable calcium is fluorometrically measured. Analysis of samples containing protei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Savory J,Gitelman HJ

    更新日期:1977-07-01 00:00:00

  • Size separation of circulatory DNA in maternal plasma permits ready detection of fetal DNA polymorphisms.

    abstract:BACKGROUND:Analysis of fetal DNA in maternal plasma has recently been introduced as a new method for noninvasive prenatal diagnosis, particularly for the analysis of fetal genetic traits, which are absent from the maternal genome, e.g., RHD or Y-chromosome-specific sequences. To date, the analysis of other fetal geneti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.029835

    authors: Li Y,Zimmermann B,Rusterholz C,Kang A,Holzgreve W,Hahn S

    更新日期:2004-06-01 00:00:00