Abstract:
:We followed the "abbreviated precision protocol" of the National Committee for Clinical Laboratory Standards for the evaluation of precision, accuracy, and carryover in analyses for glucose with the "Ektachem." We analyzed 760 clinical samples by this technique, by the FDA Proposed Class Standard glucose reference method, and with the Beckman System I GLU/BUN Analyzer. Precision and accuracy were estimated for 500, 1000, 1200, 1500, and 3000 mg/L glucose concentrations in 100, 30, or 20 microL of serum or plasma. Potential interference of 19 compounds was evaluated. Random error (1.965 X SD) was 22, 30, 34, 40, and 88 mg/L. Systematic error was 8, 1.5, -2, -5, and -27 mg/L. Total analytical error was 30, 32, 36, 46, and 110 mg/L for analysis of 100 microL of serum at the above-stated glucose concentrations. The greatest interference (-39 mg/L) in the glucose (at 1200 mg/L) determination was caused by L-ascorbate (40 mg/L). Glucose concentrations as determined with the Ektachem were found to be linearly related to the expected concentration up to at least 5660 mg/L. Carryover was not statistically significant.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Bandi ZL,Fuller JB,Bee DE,James GPsubject
Has Abstractpub_date
1981-01-01 00:00:00pages
27-34issue
1eissn
0009-9147issn
1530-8561journal_volume
27pub_type
临床试验,杂志文章abstract::Mycophenolate mofetil, the prodrug form of the immunosuppressive agent mycophenolic acid (MPA), is currently in clinical trials evaluating its effectiveness in transplant recipients. In this study, we validated an ultrafiltration system for the reliable measurement of free MPA. Using this technique, we evaluated facto...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-07-01 00:00:00
abstract::We describe a high-performance liquid chromatographic method for the quantitative determination of gentamicin in serum. The antibiotic was separated from serum by passage through a silicic acid column, derivatized with o-phthalaldehyde, and eluted with ethanol. The derivatized gentamicin was then separated into all th...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-12-01 00:00:00
abstract::The cytokine rumor necrosis factor-alpha (TNF-alpha) plays a prominent role in the inflammatory response and has been quantified in several kinds of body fluids. A safe method for keeping samples under the best storage conditions for later studies is clearly needed. We estimated TNF-alpha shelf life by using an accele...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-05-01 00:00:00
abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-05-01 00:00:00
abstract:BACKGROUND:In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. MET...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.067116
更新日期:2006-09-01 00:00:00
abstract::A new instrument has been developed that is similar in design and concept to the GeMSAEC centrifugal analyzer (Oak Ridge National Laboratory) except that electrochemical detection is used rather than optical detection. The present version has eight channels, each with its own detector. Problems of speed control and sa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-09-01 00:00:00
abstract::Ion chromatography is a new analytical technique in which the ions to be analyzed are separated on a special pellicular ion-exchange column. Once separated, the effluent from the separating column passes into a second ion-exchange column, which removes the eluent or buffer ions from the moving phase without removing t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-09-01 00:00:00
abstract::We have developed a simple, specific, and sensitive reversed-phase liquid-chromatographic method for accurate and simultaneous analysis of corticosterone and cortisol in human plasma. We achieved a detection limit of 300 ng/L for both steroids by modifying the old solid-phase extraction method to make use of "Tef Elut...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:BACKGROUND:Human herpesvirus 6 (HHV-6) latently infects a majority of adults. In about 1% of the population HHV-6 exists in a chromosomally integrated form (ciHHV-6) that resides in every somatic and germ cell and can be transmitted through the germ line. Patients with ciHHV-6 have been misdiagnosed and unnecessarily t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.217240
更新日期:2014-05-01 00:00:00
abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-01-01 00:00:00
abstract:BACKGROUND:Quantitative, miniaturized nucleic acid assays and immunoassays can be developed with single microparticles, microfluorometric detection, and intrinsically fluorescent lanthanide chelates in a multiple assay format to decrease reagent consumption, cost, and assay time. We used recombinant Fab fragments to ca...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-11-01 00:00:00
abstract::We are developing a method for quantifying plasma lipoproteins by proton nuclear magnetic resonance (NMR) spectroscopy that offers advantages over existing clinical methods. We showed that the major lipoproteins have distinct NMR properties sufficient to permit their concentrations to be extracted from a computer line...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-09-01 00:00:00
abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-09-01 00:00:00
abstract:BACKGROUND:Lectin-like oxidized LDL receptor 1 (LOX-1) is implicated in atherothrombotic diseases. Activation of LOX-1 in humans can be evaluated by use of the LOX index, obtained by multiplying the circulating concentration of LOX-1 ligands containing apolipoprotein B (LAB) times that of the soluble form of LOX-1 (sLO...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.140707
更新日期:2010-04-01 00:00:00
abstract::We evaluated the dual-precipitation method for quantitative measurement of lipoproteins as described by Wilson and Spiger [J. Lab. Clin. Med. 82, 473 (1973)] for normo- and hyperlipemic sera, by comparison with the results obtained with ultracentrifugation. If serum with an above-normal triglyceride concentration is a...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-07-01 00:00:00
abstract::We have developed and validated simple, rapid immunoassays to measure concentrations of albumin in urine ranging from 5 to 200 mg/L. We use antiserum to human albumin, raised in sheep, and we separate the antibody-bound and free fractions of albumin by using a second antiserum, produced in donkeys, against the Fc frag...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-07-01 00:00:00
abstract::Circadian variations of alanine aminopeptidase (EC 3.4.11.2), gamma-glutamyltransferase (EC 2.3.2.2), and N-acetyl-beta-glucosaminidase (EC 3.2.1.30) in urine were studied in 10 healthy children, ages six to 15 years. Urine specimens were collected during 24 h, grouped into four time intervals. Enzymes were measured s...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-05-01 00:00:00
abstract::Lyophilized serum specimens were manufactured in such a way that fixed quantitative interspecimen relationships were established. The specimens were analyzed for about twenty constituents by several thousand laboratories in 1971, 1972, and 1973. Most of the consensus mean values derived from these analyses were found ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-07-01 00:00:00
abstract::This solid-phase competitive europium immunoassay of progesterone in plasma relies on antigen labeling. With this new approach, time-resolved fluoroimmunoassay can attain sensitivity and precision similar to that of conventional radioimmunoassay. The europium-labeling involves coupling diethylenetriaminepentaacetic ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-03-01 00:00:00
abstract::This new one-step chemiluminescent immunoassay of free thyroxin (FT4) involving a thyroxin-immunoglobulin conjugate labeled with acridinium ester (Magic Lite System; Ciba Corning Diagnostics Corp., Medfield, MA) is rapid (one 1-h incubation), requires two calibrators per run, and takes 10 s per sample for the quantifi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-12-01 00:00:00
abstract:BACKGROUND:Intraventricular hemorrhage (IVH) is a major cause of neurologic disabilities in preterm newborns. We evaluated the use of plasma activin A concentrations to predict the development of perinatal IVH. METHODS:We measured nucleated erythrocyte (NRBC) counts, plasma activin A, hypoxanthine (Hyp), and xanthine ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.065979
更新日期:2006-08-01 00:00:00
abstract:BACKGROUND:Diabetes mellitus has been historically divided into type 1 and type 2 diabetes, with type 1 being an autoimmune disease and type 2 being primarily a metabolic disease. CONTENT:The current diabetes classification scheme needs to be reevaluated because of the accumulating evidence of immune system involvemen...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2010.148270
更新日期:2011-02-01 00:00:00
abstract:BACKGROUND:Recent publications have explored the possibility of using fingerprints to confirm drug use, but none has yet dealt with environmental contamination from fingertips. Here we explored the possibility of establishing an environmental cutoff for drug testing from a single fingerprint. METHODS:Fingerprint sampl...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2017.281469
更新日期:2018-06-01 00:00:00
abstract::To establish optimum conditions for creatine kinase (EC 2.7.3.2) activity measurement with the creatine phosphate in equilibrium creatine reaction, we re-examined all kinetics factors relevant to an optimal and standardized enzyme assay at 30 and 25 degrees C. We determined the pH optimum in vaious buffers, considerin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-05-01 00:00:00
abstract::A method is presented for the assay of delta-aminolaevulinate dehydratase (EC 4.2.1.24) to be performed on 10 microL of whole blood. Results compare favorably with those obtained with an accepted method (J. Clin. Chem. Clin. Bio-chem. 12: 389-390, 1974) that involves use of 200 microL of blood. ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::I describe a gas-chromatographic procedure involving a nitrogen detector for "free" (or "unbound") phenytoin in the concentration range 0.2-4.0 mg/L in ultrafiltrates of plasma. The CV (n = 10) for the assay was 2.9% for a 0.49 mg/L concentration, 1.5% for 2.02 mg/L. The sensitivity was 0.05 mg/L. The ultrafiltration ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-03-01 00:00:00
abstract::We describe a case of sulfhemoglobinemia associated with toxic paint ingestion. Blood gases, oxygen content, and fractional hemoglobin derivatives were assayed with Radiometer 520 and OSM3 instruments. Although the CO-oximeters indicated the presence of sulfhemoglobin (SulfHb), the results were not quantitative. An OS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-01-01 00:00:00
abstract::3-Hydroxy-3-methylglutaric aciduria was detected in a newborn. The progress of the dietary therapy for the disorder was monitored by dual-column "high-performance" liquid chromatography with a computer-controlled photodiode array spectrophotometric detector. This procedure is a quick way to detect and monitor the prog...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-01-01 00:00:00
abstract:BACKGROUND:A previously developed monoclonal/polyclonal ELISA (Mono/Poly) to detect plasma concentrations of osteopontin (OPN) was shown to provide prognostic information in breast, prostate, and other cancers. Here we describe the clinical validation of a new dual monoclonal (Dual Mono) assay. We compared both assays ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.117465
更新日期:2009-05-01 00:00:00
abstract:BACKGROUND:Massively parallel sequencing has recently been used in noninvasive prenatal diagnosis. The current costs of this technology are still relatively expensive, however, and sample throughput is still relatively low when it is used as a molecular diagnostic tool. Rather than nonselectively sequencing the genome,...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.154336
更新日期:2011-01-01 00:00:00