Immunoassays for low concentrations of albumin in urine.

Abstract:

:We have developed and validated simple, rapid immunoassays to measure concentrations of albumin in urine ranging from 5 to 200 mg/L. We use antiserum to human albumin, raised in sheep, and we separate the antibody-bound and free fractions of albumin by using a second antiserum, produced in donkeys, against the Fc fragment of sheep IgG. These two antisera can be mixed and added to assay tubes as a single reagent without inhibiting antigen binding. Samples or standards are incubated for at least 30 min with fluorescein-labeled albumin and the premixed antiserum reagent. After brief centrifugation, the supernate is discarded and the precipitate containing the bound fraction is dissolved and its fluorescence measured. Alternatively, 125I-labeled albumin can be used as tracer with all other reagents unchanged; in this case one simply counts the radioactivity of the bound fraction. A reference interval of less than 0.2-2.8 mg/mmol of creatinine was obtained for untimed, daytime, midstream urine specimens from 80 healthy subjects.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Silver A,Dawnay A,Landon J,Cattell WR

subject

Has Abstract

pub_date

1986-07-01 00:00:00

pages

1303-6

issue

7

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

杂志文章
  • Intra- and interindividual biological variation of five analytes used in assessing thyroid function: implications for necessary standards of performance and the interpretation of results.

    abstract::Intra- and interindividual components of biological variation have been determined for total thyroxin (TT4), free thyroxin (FT4), total triiodothyronine (TT3), free triiodothyronine (FT3), and thyrotropin (TSH). Calculated analytical goals (CV, %) for the precision required for optimal patient care are: TT4 less than ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Browning MC,Ford RP,Callaghan SJ,Fraser CG

    更新日期:1986-06-01 00:00:00

  • Central role of zinc protoporphyrin in staging iron deficiency.

    abstract::In iron deficiency, zinc protoporphyrin (ZPP) is produced instead of heme, and the ZPP concentration in erythrocytes is increased (normal < or = 40 mumol/mol heme). We investigated the relevance of ZPP for staging iron deficiency. ZPP was determined by hematofluorometry in samples from 103 patients. Nineteen patients ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hastka J,Lasserre JJ,Schwarzbeck A,Hehlmann R

    更新日期:1994-05-01 00:00:00

  • IgG heavy-chain subclass typing of myeloma paraproteins by isoelectric focusing immunoblot analysis.

    abstract::The objective of this study was to develop a clinical laboratory method for subclass typing of human immunoglobulin G (IgG) paraproteins. Serum proteins were isoelectrically focused (IEF) in a mini-gel and passively blotted by capillary diffusion onto untreated nitrocellulose. Unreacted sites on the nitrocellulose wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fasullo FJ Jr,Fritsche HA Jr,Liu FJ,Hamilton RG

    更新日期:1989-03-01 00:00:00

  • Evaluation of "HemoCue," a new device for determining hemoglobin.

    abstract::Hemoglobinometry according to the International Committee of Standardization in Hematology (ICSH) suffers from imprecision related to high sample dilution and from potential errors owing to sample turbidity. We have evaluated a new instrument, "HemoCue," that measures hemoglobin at two wavelengths as azide methemoglob...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Schenck H,Falkensson M,Lundberg B

    更新日期:1986-03-01 00:00:00

  • Clinical evaluation of the Elecsys beta-CrossLaps serum assay, a new assay for degradation products of type I collagen C-tlopeptides.

    abstract:BACKGROUND:The Elecsys beta-CrossLaps serum assay measures type I collagen degradation fragments (beta-CTx) that contain the beta-isomerized octapeptide EKAHD-beta-GGR. We investigated the analytical performance of the assay and changes in beta-CrossLaps in patients with metabolic bone diseases. METHODS:The electroche...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Okabe R,Nakatsuka K,Inaba M,Miki T,Naka H,Masaki H,Moriguchi A,Nishizawa Y

    更新日期:2001-08-01 00:00:00

  • Measurement and characterization of angiotensin peptides in plasma.

    abstract::We report a method for the extraction of angiotensin peptides from plasma with a mixture of acetone, 1 mol/L HCl, and water (40/1/5 by vol). The method is highly reproducible for the measurement of angiotensin I and angiotensin II in small sample volumes, with analytical recoveries of about 80% for both peptides. We i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hermann K,Ganten D,Unger T,Bayer C,Lang RE

    更新日期:1988-06-01 00:00:00

  • Serum thyrotropin as measured with a one-step monoclonal-antibody radioimmunometric assay compared with two commercial radioimmunoassay kits.

    abstract::We compared results obtained with a commercial immunoradiometric assay kit for human thyrotropin in which monoclonal antibodies are used (Tandem -R TSH (ONE STEP) ImmunoRadioMetricAssay; Hybritech Inc.) with those obtained with two commercial radioimmunoassay methods: GAMMA-DAB [125I]HS-hTSH RIA (Clinical Assays) and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pekary AE,Hershman JM

    更新日期:1986-06-01 00:00:00

  • Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

    abstract::With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Voelter W,Bauer H

    更新日期:1975-12-01 00:00:00

  • Validation of RNA arbitrarily primed PCR probes hybridized to glass cDNA microarrays: application to the analysis of limited samples.

    abstract:BACKGROUND:The applicability of microarray-based transcriptome massive analysis is often limited by the need for large amounts of high-quality RNA. RNA arbitrarily primed PCR (RAP-PCR) is an unbiased fingerprinting PCR technique that reduces both the amount of initial material needed and the complexity of the transcrip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.036236

    authors: Grau M,Solé X,Obrador A,Tarafa G,Vendrell E,Valls J,Moreno V,Peinado MA,Capellá G

    更新日期:2005-01-01 00:00:00

  • Carcinoembryonic antigen as a marker for colorectal cancer: is it clinically useful?

    abstract:BACKGROUND:Carcinoembryonic antigen (CEA) is one of the most widely used tumor markers worldwide. Its main application is mostly in gastrointestinal cancers, especially in colorectal malignancy. Although in use for almost 30 years, the clinical value of CEA in colorectal cancer is still not clear. METHODS:The literatu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Duffy MJ

    更新日期:2001-04-01 00:00:00

  • Bioinformatics for clinical next generation sequencing.

    abstract:BACKGROUND:Next generation sequencing (NGS)-based assays continue to redefine the field of genetic testing. Owing to the complexity of the data, bioinformatics has become a necessary component in any laboratory implementing a clinical NGS test. CONTENT:The computational components of an NGS-based work flow can be conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2014.224360

    authors: Oliver GR,Hart SN,Klee EW

    更新日期:2015-01-01 00:00:00

  • Real-time PCR technology for cancer diagnostics.

    abstract:BACKGROUND:Advances in the biological sciences and technology are providing molecular targets for diagnosing and treating cancer. Current classifications in surgical pathology for staging malignancies are based primarily on anatomic features (e.g., tumor-node-metastasis) and histopathology (e.g., grade). Microarrays to...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bernard PS,Wittwer CT

    更新日期:2002-08-01 00:00:00

  • Direct multiplex assay of lysosomal enzymes in dried blood spots for newborn screening.

    abstract:BACKGROUND:Newborn screening for deficiency in the lysosomal enzymes that cause Fabry, Gaucher, Krabbe, Niemann-Pick A/B, and Pompe diseases is warranted because treatment for these syndromes is now available or anticipated in the near feature. We describe a multiplex screening method for all five lysosomal enzymes tha...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.035907

    authors: Li Y,Scott CR,Chamoles NA,Ghavami A,Pinto BM,Turecek F,Gelb MH

    更新日期:2004-10-01 00:00:00

  • Collection of blood on filter paper for measurement of glycated hemoglobin by affinity chromatography.

    abstract::We present data on a filter-paper collection and assay method for measurement of glycated hemoglobin (gHb). Onto filter paper dipped into a solution of glucose oxidase (EC 1.1.3.4) and allowed to dry, approximately 20 microL of capillary blood was spotted. For analysis, we eluted the dried blood spot from the paper by...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Little RR,McKenzie EM,Wiedmeyer HM,England JD,Goldstein DE

    更新日期:1986-05-01 00:00:00

  • Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range.

    abstract:BACKGROUND:Cyclosporin A (CsA) is commonly measured by immunoassay techniques that have a limited analytical range. The consequence of this is that low CsA concentrations that may be clinically significant are difficult to measure and that high concentrations require sample dilution, which introduces error and increase...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Keevil BG,Tierney DP,Cooper DP,Morris MR

    更新日期:2002-01-01 00:00:00

  • Cortisol production rate determined by radio gas-chromatography.

    abstract::We describe a ratio gas-chromatographic method for determination of cortisol production rate by measuring the isotope dilution of urinary cortisol metabolites. The method was calibrated by analyzing [3H]tetrahydrocortisol and [3H]tetrahydrocortisone of known specific activities. Results are reasonably well reproducibl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Derks HJ,Muskiet FA,Wolthers BG,Thijssen JH,Drayer NM

    更新日期:1977-03-01 00:00:00

  • Lp-PLA2: a new kid on the block.

    abstract:BACKGROUND:Atherosclerosis is a systemic disease with focal rupture of vulnerable plaque responsible for major clinical events. Several population-based studies indicate an association between lipoprotein-associated phospholipase A2 (Lp-PLA2) and cardiovascular events. Lp-PLA2 is emerging as a biomarker that may be a p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2006.070672

    authors: Zalewski A,Nelson JJ,Hegg L,Macphee C

    更新日期:2006-09-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ

    更新日期:1994-06-01 00:00:00

  • Continuous-flow determination of dialyzable calcium in serum.

    abstract::We describe a procedure for measuring dialyzable calcium in 60 sera per hour with use of AutoAnalyzer (Technicon) modules. The serum is buffered, then dialyzed in a regular 6-inch (15-cm) dialysis block. A constant proportion of the dialyzable calcium is fluorometrically measured. Analysis of samples containing protei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Savory J,Gitelman HJ

    更新日期:1977-07-01 00:00:00

  • Clinical pharmacology of anti-epileptic drugs: a summary of current information.

    abstract::This compendium represents what we believe to be the most current and reliable pharmacological data on anticonvulsant drugs. The information presented is derived from determinations of the drugs in plasma or serum by gas--liquid chromatography in studies of the efficacy of anti-epileptic agents. We present information...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Leal KW,Troupin AS

    更新日期:1977-11-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • Single-Stranded DNA Library Preparation Preferentially Enriches Short Maternal DNA in Maternal Plasma.

    abstract:BACKGROUND:Recent studies have suggested that single-stranded DNA (ssDNA) library preparation can enrich short DNA species from the plasma of healthy individuals, cancer patients, and transplant recipients. Based on previous observations that fetal DNA molecules in the maternal plasma are shorter than maternal DNA mole...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.268656

    authors: Vong JSL,Tsang JCH,Jiang P,Lee WS,Leung TY,Chan KCA,Chiu RWK,Lo YMD

    更新日期:2017-05-01 00:00:00

  • Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

    abstract::We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Li PK,Shull BC

    更新日期:1979-04-01 00:00:00

  • Concentrations of morphine and codeine in serum and urine after ingestion of poppy seeds.

    abstract::We measured morphine and codeine in commercially available poppy seeds and in serum and urine samples from healthy adults who had ingested these poppy seeds. Four brands of black poppy seeds, examined by gas chromatography-mass spectroscopy (GC-MS) with deuterated internal standards, contained from 17 to 294 microgram...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hayes LW,Krasselt WG,Mueggler PA

    更新日期:1987-06-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00

  • Creatine kinase BB: a new tumor-associated marker.

    abstract::Creatine kinase isoenzyme BB (CK-BB) is found in the serum of patients with various types of cancer. Using both radioimmunoassay and agarose electrophoresis, we found abnormal amounts of this isoenzyme in the serum of 15 of 17 patients with untreated prostatic carcinoma. Among patients with other types of adenocarcino...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Zweig MH,Van Steirteghem AC,Tökés ZA

    更新日期:1979-08-01 00:00:00

  • Use of the laboratory in prediction of outcome in the high-risk newborn.

    abstract::This paper reviews our ability to predict survival and neurodevelopmental outcome in the newborn period. Traditionally, prognosis is based on individual risk factors or disease states. The laboratory plays an important role in diagnosing some of these. For example, prenatal and newborn screening are important in the d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Synnes AR

    更新日期:1997-01-01 00:00:00

  • Associations between serum gamma-glutamyltransferase and apolipoproteins: relationships with hepatobiliary diseases.

    abstract::We studied the association between gamma-glutamyltransferase (GGT) and apolipoproteins A or B in serum of 42 patients with various hepatobiliary diseases. Binding of the enzyme to apolipoprotein A is not related to a clearly defined disease, but appears to be mainly influenced by the ratio of total cholesterol to GGT ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Artur Y,Wellman-Bednawska M,Jacquier A,Siest G

    更新日期:1984-08-01 00:00:00

  • A candidate reference method for uric acid in serum. II. Interlaboratory testing.

    abstract::We describe the interlaboratory testing of a candidate Reference Method (Part I) for uric acid in serum. The method is based on the ultrasound spectrophotometric quantitation of uric acid before and after incubation with uricase. A comprehensive investigation involving 12 laboratories was organized to document the tra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Duncan P,Gochman N,Bayse D,Burnett R,Carey N,Carter R,Fellows WD,Garber C,Kessler G,McComb R,Miller W,Nast P,Ryan W,Schaffer R,Tejeda B,Vanderlinde R,Widdowson G

    更新日期:1982-02-01 00:00:00