Changes in concentrations of C-reactive protein in serum after kidney or heart transplantation.

Abstract:

:C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly depressed the postsurgical CRP response in transplant recipients. The effect is greatest with the administration of cyclosporine. In addition, we found serial CRP determinations to be a sensitive indicator of renal but not cardiac allograft rejection. The specificity of CRP as such a predictor was affected by non-rejection-based inflammation. We conclude that serial determination of CRP, interpreted by the extent by which its concentration increases between sequential samples, may be a useful adjunct to biochemical monitoring of renal transplants, but a similar approach to monitoring heart transplants is not possible.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Van Lente F,Castellani W,Abbott LB

subject

Has Abstract

pub_date

1986-04-01 00:00:00

pages

633-6

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

32

pub_type

杂志文章
  • Plasma F2-isoprostanes and coronary artery calcification: the CARDIA Study.

    abstract:BACKGROUND:Oxidation of lipids in lipoproteins and cells may initiate and enhance the early development of cardiovascular disease. METHOD AND RESULTS:We assayed F(2)-isoprostanes, oxidation products of arachidonic acid, by gas chromatography-mass spectrometry in a biracial cohort of 2850 young healthy adult men and wo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.037630

    authors: Gross M,Steffes M,Jacobs DR Jr,Yu X,Lewis L,Lewis CE,Loria CM

    更新日期:2005-01-01 00:00:00

  • Simultaneous determination of free testosterone and testosterone bound to non-sex-hormone-binding globulin by equilibrium dialysis.

    abstract::We describe a procedure based on equilibrium dialysis that allows the simultaneous determination of free testosterone and testosterone bound to non-sex-hormone-binding globulin (non-SHBG) in plasma. After saturating SHBG with 5 alpha-dihydrotestosterone (DHT) according to a technique recently described, the percentage...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Barini A,Liberale I,Menini E

    更新日期:1993-06-01 00:00:00

  • Computerized multicuvette system for single substance and group analysis and for the chromatographic isolation and quantitation of compounds in complex mixtures.

    abstract::A new computer-interfaced system of general applicability in the clinical laboratory has been built. The system is constructed around a new type multicuvette. Quantitation is currently by spectrophotometry and is on-line, with use of a mini-computer with output going to an electrostatic printer/plotter. The system can...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vestergaard P,Bachman A

    更新日期:1975-08-01 00:00:00

  • Quinidine-induced decrease of intracellular esterase activity in a hepatoma cell line.

    abstract::Using image-analyzing equipment, we measured the effect of quinidine on the activity of naphthol AS-D chloroacetate esterase, alpha-naphthyl butyrate esterase, alpha-naphthyl acetate esterase, and acid phosphatase in individual cells of a human Hep G2 hepatoma cell line. The impact of the drug on the morphology of the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Markovic OT,Young DS,Markovic NS

    更新日期:1988-03-01 00:00:00

  • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC.

    abstract::Assays with different specificity are used for cyclosporin monitoring in clinical transplantation. A recent survey of 35 centers showed that 86% used immunoassays for cyclosporin A (CsA). In consensus documents the following performance criteria were recommended: (a) imprecision < or = 10% at 50 microg/L and < or = 5%...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schütz E,Svinarov D,Shipkova M,Niedmann PD,Armstrong VW,Wieland E,Oellerich M

    更新日期:1998-10-01 00:00:00

  • Microassay for nuclear binding of steroid receptors with use of intact cells from small samples of avian and human tissue.

    abstract::A micro version of a nuclear binding assay to assess the biological activity of receptors for steroid hormones was developed for application to small (needle) biopsies of human tumors for the purpose of predicting responses to steroid therapy. This easier assay requires 10-fold less tissue than the original nuclear bi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colvard DS,Jankus WR,Berg NJ,Graham ML 2nd,Jiang NS,Ingle JN,Spelsberg TC

    更新日期:1988-02-01 00:00:00

  • Strong association of a single nucleotide substitution in the 3'-untranslated region of the apolipoprotein-CIII gene with common hypertriglyceridemia in Arabs.

    abstract::A potential genetic marker for hypertriglyceridemia and coronary disease, an apolipoprotein-CIII gene allele displaying a single nucleotide substitution, was found in 71% of Arabs with primary hypertriglyceridemia. Over 96% of the unrelated adults possessing this allele showed hypertriglyceridemia. The same allele was...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taş S

    更新日期:1989-02-01 00:00:00

  • Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.

    abstract::Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and H...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: März W,Siekmeier R,Scharnagl H,Seiffert UB,Gross W

    更新日期:1993-11-01 00:00:00

  • Abbott TDx monoclonal antibody assay evaluated for measuring cyclosporine in whole blood.

    abstract::We report here the evaluation of the Abbott TDx assay with a monoclonal antibody for selectively quantifying cyclosporine (CsA) in whole blood. Over the clinically relevant concentration ranges, results with this assay demonstrated within- and between-run CVs of less than 2.5% and 5%, respectively; sensitivity of 25 m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yatscoff RW,Copeland KR,Faraci CJ

    更新日期:1990-11-01 00:00:00

  • A method of assessing serum triiodothyronine concentrations that is independent of subject's age and variations in concentrations of binding proteins in serum.

    abstract::Pairs of values for serum triiodothyronine and serum triiodothyronine binding capacity were represented as maps of points for euthyroid populations (including subjects who were pregnant or were receiving estrogens) in the age groups 18-50, 51-64, 65-79, and greater than 80 years (504 subjects) and thyrotoxic populatio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mardell R,Gerson M

    更新日期:1978-10-01 00:00:00

  • Clinical and genetic correlates of growth differentiation factor 15 in the community.

    abstract:BACKGROUND:Growth differentiation factor 15 (GDF15), a stress-responsive cytokine produced in cardiovascular cells under conditions of inflammation and oxidative stress, is emerging as an important prognostic marker in individuals with and without existing cardiovascular disease (CVD). We therefore examined the clinica...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2012.190322

    authors: Ho JE,Mahajan A,Chen MH,Larson MG,McCabe EL,Ghorbani A,Cheng S,Johnson AD,Lindgren CM,Kempf T,Lind L,Ingelsson E,Vasan RS,Januzzi J,Wollert KC,Morris AP,Wang TJ

    更新日期:2012-11-01 00:00:00

  • Measurement of free and free-plus-peptide hydroxyproline fractions in plasma.

    abstract::Plasma hydroxyproline fractions--free-plus-peptide and free--were determined by a method involving centrifugal ultrafiltration and the procedure of Kivirikko et al. [Anal. Biochem. 19, 249 (1967)]. Within- and between-day precision (CV) for the combined fractions was 4--5% and 2.8--6%, respectively. Mean analytical re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Husdan H,Leung M,Oreopoulos D,Rapoport A

    更新日期:1978-02-01 00:00:00

  • Subclass typing of IgG paraproteins by immunofixation electrophoresis.

    abstract::We present a simple method for subclass typing of IgG paraproteins, with which we have demonstrated a large number of paraproteins that were undetected by conventional immunofixation techniques. The types and distribution of IgG subclass paraproteins were analyzed in 92 human sera in which IgG paraproteins had been de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Klouche M,Bradwell AR,Wilhelm D,Kirchner H

    更新日期:1995-10-01 00:00:00

  • New Colorimetric reaction for end-point, continuous-flow, and kinetic measurement of urea.

    abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jung D,Biggs H,Erikson J,Ledyard PU

    更新日期:1975-07-01 00:00:00

  • Highly sensitive cholesterol assay with enzymatic cycling applied to measurement of remnant lipoprotein-cholesterol in serum.

    abstract:BACKGROUND:Remnant lipoprotein-cholesterol (RLP-C) concentrations in sera of healthy individuals are very low (0.080-0.437 mmol/L), making conventional cholesterol methods poorly suited to this purpose. We have developed a highly sensitive cholesterol assay (CD method) and applied it to the RLP-C assay. METHODS:The CD...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kishi K,Ochiai K,Ohta Y,Uemura Y,Kanatani K,Nakajima K,Nakamura M

    更新日期:2002-05-01 00:00:00

  • Sensitivity and specificity of single-nucleotide polymorphism scanning by high-resolution melting analysis.

    abstract:BACKGROUND:Screening for heterozygous sequence changes in PCR products, also known as "mutation scanning", is an important tool for genetic research and clinical applications. Conventional methods require a separation step. METHODS:We evaluated the sensitivity and specificity of homogeneous scanning, using a saturatin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.029751

    authors: Reed GH,Wittwer CT

    更新日期:2004-10-01 00:00:00

  • Oxygen toxicity related to exposure to lead.

    abstract::We evaluated superoxide dismutase (EC 1.15.1.1) and glutathione peroxidase (EC 1.11.1.9) activities in the erythrocytes of lead-exposed and nonexposed workers from distinct industries localized in the State of São Paulo, Brazil. Concentrations of either lead or protoporphyrin IX, or both, in blood were used to indicat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Monteiro HP,Abdalla DS,Arcuri AS,Bechara EJ

    更新日期:1985-10-01 00:00:00

  • Improved column method for separating lactate dehydrogenase isoenzymes 1 and 2.

    abstract::Lactate dehydrogenase (LD) isoenzymes 1 and 2 in human serum were separated on a column of diethylaminoethyl-Sephadex. Samples layered on mini-columns were eluted with buffered sodium chloride (100, 150, and 200 mmol/liter). Lactate dehydrogenase activity in column effluents was measured by the Wacker method, and thei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mercer DW

    更新日期:1978-03-01 00:00:00

  • Human kallikrein gene 5 (KLK5) expression by quantitative PCR: an independent indicator of poor prognosis in breast cancer.

    abstract:BACKGROUND:KLK5 is a newly discovered human kallikrein gene. Many kallikrein genes have been found to be differentially expressed in various malignancies, and prostate-specific antigen (PSA; encoded by the KLK3 gene) is the best tumor marker for prostate cancer. Like the genes that encode PSA and other kallikreins, the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yousef GM,Scorilas A,Kyriakopoulou LG,Rendl L,Diamandis M,Ponzone R,Biglia N,Giai M,Roagna R,Sismondi P,Diamandis EP

    更新日期:2002-08-01 00:00:00

  • Rapid diagnosis of phenylketonuria by quantitative analysis for phenylalanine and tyrosine in neonatal blood spots by tandem mass spectrometry.

    abstract::A new method for quantifying specific amino acids in small volumes of plasma and whole blood has been developed. Based on isotope-dilution tandem mass spectrometry, the method takes only a few minutes to perform and requires minimal sample preparation. The accurate assay of both phenylalanine and tyrosine in dried blo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chace DH,Millington DS,Terada N,Kahler SG,Roe CR,Hofman LF

    更新日期:1993-01-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • The National Glycohemoglobin Standardization Program: Over 20 Years of Improving Hemoglobin A1c Measurement.

    abstract:BACKGROUND:Measurement of hemoglobin A1c (HbA1c) in the blood is integral to and essential for the treatment of patients with diabetes mellitus. HbA1c reflects the mean blood glucose concentration over the preceding 8 to 12 weeks. Although the clinical value of HbA1c was initially limited by large differences in result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.296962

    authors: Little RR,Rohlfing C,Sacks DB

    更新日期:2019-07-01 00:00:00

  • Automated analysis for plasma epinephrine and norepinephrine by liquid chromatography, including a sample cleanup procedure.

    abstract::We describe a fully automated method of analysis for plasma epinephrine and norepinephrine by use of a two-column system of "high-performance" liquid chromatography. Catecholamines in deproteinized plasma are purified on the first (preparation) column, then transferred automatically to the second (analytical) column i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Yamatodani A,Wada H

    更新日期:1981-12-01 00:00:00

  • Automated enhanced latex agglutination assay for rheumatoid factors in serum.

    abstract::This improved assay of rheumatoid factors in serum, described here for use with the Baker "Encore" centrifugal analyzer, is efficient, with 250-sample throughput per hour; reproducible, with between-batch CV = 5% and within-batch CV = 2% (mid-assay range); and results correlate well (r = 0.9) with those by other metho...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkles JW,Lunec J,Gray L

    更新日期:1989-02-01 00:00:00

  • Modifying an enzyme immunoassay of immunoreactive trypsinogen to use time-resolved fluorescence.

    abstract::A coated microtiter-well, enzyme-linked immunometric assay for quantifying immunoreactive trypsinogen in dried blood spots was modified to use time-resolved fluorescence of europium in place of end-point enzymatic color development as the quantification step. The streptavidin-horseradish peroxidase and color developme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ryall RG,Gjerde EM,Gerace RL,Ranieri E

    更新日期:1993-02-01 00:00:00

  • Radioimmunoassay for detecting hepatitis B core antigen in serum from patients with chronic hepatitis B infection.

    abstract::The core antigen component of hepatitis B virus (HBV), HBcAg, may be used as a marker of viral replication. We describe a radioimmunoassay for HBcAg in serum, and compare results with those by other similar methods. Samples are centrifuged over a sucrose gradient containing 2-mercaptoethanol, and the resulting pellets...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quiroga JA,González O,Carreño V,Mora I,Porres JC,Gutiez J,Hernández-Guío C

    更新日期:1985-06-01 00:00:00

  • Relationship of lipoprotein-associated phospholipase A₂ mass and activity with incident vascular events among primary prevention patients allocated to placebo or to statin therapy: an analysis from the JUPITER trial.

    abstract:BACKGROUND:Although lipoprotein-associated phospholipase A(2) (Lp-PLA(2)) levels are associated with cardiovascular events, Lp-PLA(2) is physically linked to LDL cholesterol (LDL-C). Whether measures of Lp-PLA(2) mass or activity continue to predict risk after LDL-C reduction by statin therapy is uncertain. METHODS:Lp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.180281

    authors: Ridker PM,MacFadyen JG,Wolfert RL,Koenig W

    更新日期:2012-05-01 00:00:00

  • Avidin-biotin enzyme immunoassay of osteocalcin in serum or plasma.

    abstract::We describe a competitive enzyme immunoassay, the ExtrAvidin-biotin system, for determining osteocalcin in human serum or plasma. Antibodies were raised against bovine osteocalcin. Binding of the antibodies to osteocalcin was calcium-dependent. Limit of detection is 0.07 nmol/L (0.4 microgram/L). The standard curve fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jaouhari J,Schiele F,Dragacci S,Tarallo P,Siest JP,Henny J,Siest G

    更新日期:1992-10-01 00:00:00

  • Robotic chromatography: development and evaluation of automated instrumentation for assay of glycohemoglobin.

    abstract::The measurement of glycohemoglobin (GHb) by boronate affinity chromatography is useful in monitoring long-term glucose control in diabetic subjects. The inherent disadvantage of this method is the hands-on time required because the hemoglobin fractions are separated on individual disposable columns. To overcome this d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Herold CD,Andree K,Herold DA,Felder RA

    更新日期:1993-01-01 00:00:00

  • Acyclic adenine nucleoside phosphonates in plasma determined by high-performance liquid chromatography with fluorescence detection.

    abstract::9-(2-Phosphonylmethoxyethyl)adenine (PMEA), (S)-9-(3-hydroxy-2-phosphonylmethoxypropyl)adenine (HPMPA), and (R,S)-9-(3-fluoro-2-phosphonylmethoxypropyl)adenine (FPMPA) are selective antiviral agents with activity against a broad spectrum of DNA viruses and retroviruses. A highly sensitive method has been developed to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Naesens L,Balzarini J,De Clercq E

    更新日期:1992-04-01 00:00:00