Oxygen toxicity related to exposure to lead.

Abstract:

:We evaluated superoxide dismutase (EC 1.15.1.1) and glutathione peroxidase (EC 1.11.1.9) activities in the erythrocytes of lead-exposed and nonexposed workers from distinct industries localized in the State of São Paulo, Brazil. Concentrations of either lead or protoporphyrin IX, or both, in blood were used to indicate the extent of exposure. In all cases, values for superoxide dismutase were significantly higher in the exposed workers. The dose-response relationship between this enzyme and lead concentrations was roughly linear for the workers with greater than 40 micrograms of lead per 100 g of blood. Except for the sample from one of the industries, the corresponding glutathione peroxidase activities were also significantly higher in lead-exposed workers. These data, together with those previously found for patients with intermittent acute porphyria, suggest that in both groups the accumulation of heme precursors is connected to the exacerbated production of activated oxygen species.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Monteiro HP,Abdalla DS,Arcuri AS,Bechara EJ

subject

Has Abstract

pub_date

1985-10-01 00:00:00

pages

1673-6

issue

10

eissn

0009-9147

issn

1530-8561

journal_volume

31

pub_type

杂志文章
  • Laboratory methods and quality assurance in the Cardiovascular Health Study.

    abstract::The Cardiovascular Health Study is an observational cohort study of risk factors for cardiovascular disease in 5201 participants, ages > or = 65 years. We report the methods and quality-assurance results for blood procurement, processing, shipping, storage, and sample analysis used during the first examination period ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cushman M,Cornell ES,Howard PR,Bovill EG,Tracy RP

    更新日期:1995-02-01 00:00:00

  • Expression of prostate-specific antigen and prostate-specific membrane antigen transcripts in blood cells: implications for the detection of hematogenous prostate cells and standardization.

    abstract::Circulating prostate cells can be detected in cancer patients by using reverse transcriptase-PCR (RT-PCR) assay for prostate-specific antigen (PSA) and prostate-specific membrane antigen (PSM) mRNA. A quality-control study involving a conventional RT-PCR assay was performed and, surprisingly, detected both transcripts...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gala JL,Heusterspreute M,Loric S,Hanon F,Tombal B,Van Cangh P,De Nayer P,Philippe M

    更新日期:1998-03-01 00:00:00

  • Evaluation of the IFCC-recommended procedure for serum aspartate aminotransferase as modified for use with the centrifugal analyzer.

    abstract::The IFCC-recommended procedure for aspartate aminotransferase (EC 2.6.1.1) was adapted to the centrifugal analyzer and evaluated during five years. The main hindrance to widespread use of the recommended method is the need for pre-incubation with pyridoxal phosphate. The present method includes a 10-min pre-incubation...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bruns DE,Savory J,Titheradge AC,Cross RE,Wills MR

    更新日期:1981-01-01 00:00:00

  • Measurement of glycated protein by a rapid and specific method for absolute quantification of lysine-bound glucose.

    abstract::We modified the liquid-chromatographic assay of Schleicher and Wieland (J Clin Chem Clin Biochem 1981; 19:81-7) for measuring lysine-bound glucose in serum proteins, increasing its performance and practicality. After precipitating serum proteins from 10- to 50-microL samples with ethanol (700 mL/L) and hydrolyzing the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Drexel H,Klocker H,Patsch JR,Breier C,Braunsteiner H

    更新日期:1987-09-01 00:00:00

  • Characterization of a monoclonal antibody (HB-22) and development of an ELISA for human apolipoprotein A-I.

    abstract::We describe the production and characterization of a high-affinity monoclonal antibody, HB-22, for apolipoprotein (apo) A-I, a major protein of human high-density lipoproteins (HDL). Including Tween 20 in the reaction mixture increased the binding capacity of HB-22 to apo A-I. HB-22 showed monospecific reactivity with...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rothwell TC,Kamanna VS,Jin FY,Koren E,Foley T,Kashyap ML

    更新日期:1995-08-01 00:00:00

  • Analysis of the physicochemical state of C-reactive protein in different preparations including 2 certified reference materials.

    abstract:BACKGROUND:Standardization of clinical measurements of C-reactive protein (CRP) is based on the availability of reference materials. The serum protein reference material ERM-DA470 was used as a calibrant for various commercially available immunoassays but has now been exhausted. The recently released ERM-DA470k/IFCC wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.147124

    authors: Rzychon M,Zegers I,Schimmel H

    更新日期:2010-09-01 00:00:00

  • Automated on-line solid-phase extraction coupled with HPLC for measurement of 5-hydroxyindole-3-acetic acid in urine.

    abstract:BACKGROUND:Quantification of 5-hydroxyindole-3-acetic acid (5-HIAA) in urine is useful in diagnosing and monitoring of patients with carcinoid tumors and in the study of serotonin (5-hydroxytryptamine) metabolism in various disorders. We describe an automated method that incorporates on-line solid-phase extraction (SPE...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050062

    authors: Mulder EJ,Oosterloo-Duinkerken A,Anderson GM,De Vries EG,Minderaa RB,Kema IP

    更新日期:2005-09-01 00:00:00

  • Improved 63Ni radiochemical assay of free fatty acids in plasma.

    abstract::We have modified the 63Ni radiochemical method of Ho (Anal Biochem 1970;36:105) for determination of free fatty acids (FFA) in plasma. Extracting 1 or 0.1 mL of plasma with Dole's mixture (J Biol Chem 1960;235:2595) and washing the "heptane" layer with two volumes of isopropanol/water/dilute (0.5 mol/L) H2SO4 (25/25/1...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Barash H,Akov S

    更新日期:1987-01-01 00:00:00

  • Minimal disease detection and confirmation in hematologic malignancies: combining cell sorting with clonality profiling.

    abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061259

    authors: Zehentner BK,Fritschle W,Stelzer T,Ghirardelli KM,Hunter K,Wentzel C,Bennington R,Hansen CL,Myerson D,Kalnoski M,Wells DA,Loken MR

    更新日期:2006-03-01 00:00:00

  • Simple spectrophotometric determination of urinary albumin by dye-binding with use of bromphenol blue.

    abstract::This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schosinsky KH,Vargas M,Luz Esquivel A,Chavarria MA

    更新日期:1987-02-01 00:00:00

  • Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma.

    abstract:BACKGROUND:It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046995

    authors: Gellekink H,van Oppenraaij-Emmerzaal D,van Rooij A,Struys EA,den Heijer M,Blom HJ

    更新日期:2005-08-01 00:00:00

  • Plasma lipoprotein peroxidation potential: a test to evaluate individual susceptibility to peroxidation.

    abstract::Peroxidation of lipids is believed to play a key role in various degenerative diseases. However, few simple tests are able to detect individual susceptibility or resistance to peroxidation. Measurement of the basal concentrations of lipid peroxides in plasma is not satisfactory because they are so low. Therefore, we d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Arshad MA,Bhadra S,Cohen RM,Subbiah MT

    更新日期:1991-10-01 00:00:00

  • Plasma glucose concentrations of whole blood, as determined with a multilayer-film analytical element.

    abstract::A new type of multilayer film analytical element--consisting of a spreading layer, a blocking layer, an enzymic reagent layer, and a transparent layer--has been developed for blood glucose determination. After a spot of whole blood is dropped on the film, the plasma glucose concentration is determined in 6 min without...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ohkubo A,Kamei S,Yamanaka M,Arai F,Kitajima M,Kondo A

    更新日期:1981-07-01 00:00:00

  • An unusual case of toluene-induced metabolic acidosis.

    abstract::We used gas chromatography-mass spectrometry to analyze serum specimens from a patient whose metabolic ketoacidosis resulted from sniffing a toluene-containing substance; we also analyzed a sample of the abused substance itself and a serum specimen from a normal subject. The blood samples from the patient showed abnor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jone CM,Wu AH

    更新日期:1988-12-01 00:00:00

  • Liquid-chromatographic profiling of solutes in serum of uremic patients undergoing hemodialysis and chronic ambulatory peritoneal dialysis (CAPD); high concentrations of pseudouridine in CAPD patients.

    abstract::Using "high performance" liquid chromatography, we studied non-protein-bound fractions and total concentrations of 18 solutes accumulating in sera from a group of 12 patients who were undergoing chronic ambulatory peritoneal dialysis (CAPD) and in predialysis sera from a group of 15 hemodialysis (HD) patients. We moni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schoots AC,Gerlag PG,Mulder AW,Peeters JA,Cramers CA

    更新日期:1988-01-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • High-performance liquid-chromatographic analysis for serotonin and tryptamine excreted in urine after oral loading with L-tryptophan.

    abstract::We describe a method used for determining serotonin and tryptamine in urine after oral loading with their precursor amino acid. Several factors affecting prepurification and chromatographic separation of both indoleamines were optimized, including sample extraction and mobile-phase composition. Under optimal condition...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuchiya H,Hayashi T,Tatsumi M,Hoshino Y,Ohtani S,Takagi N

    更新日期:1989-01-01 00:00:00

  • Immunological and colorimetric determination of prostatic acid phosphatase--technical and clinical reappraisal in symptomatic patients.

    abstract::We compared a selection of quantitative immunological methods for prostatic acid phosphatase (PAP) with routine colorimetric assays for total and tartrate-labile acid phosphatase and evaluated their relative clinical merits in the differential diagnosis of prostatic carcinoma. We also assessed a wide range of commerci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gibb I,Wilson LA,Powell PH,Tarbit I,Pratt D,Hall RR

    更新日期:1986-09-01 00:00:00

  • Development of a chemiluminescence competitive PCR for the detection and quantification of parvovirus B19 DNA using a microplate luminometer.

    abstract:BACKGROUND:Quantitative PCR of viral nucleic acids can be useful clinically in diagnosis, risk assessment, and monitoring of antiviral therapy. We wished to develop a chemiluminescence competitive PCR (cPCR) for parvovirus B19. METHODS:Parvovirus DNA target sequences and competitor sequences were coamplified and direc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fini F,Gallinella G,Girotti S,Zerbini M,Musiani M

    更新日期:1999-09-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Improved estimation of fructosamine, as a measure of glycated serum protein, with the Technicon RA-1000 analyzer.

    abstract::We present an improved fructosamine assay for use with the Technicon RA-1000 analyzer. Features of this assay include: specimen throughput of 100 per hour, within-batch CV of 1.5%, between-batch CV of 2.4%, standard curve linear up to 24.9 mmol of fructosamine per liter, and good correlation (r = 0.82) with hemoglobin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: San-Gil F,Schier GM,Moses RG,Gan IE

    更新日期:1985-12-01 00:00:00

  • Role of nitric oxide in cardiovascular disease: focus on the endothelium.

    abstract::Nitric oxide is a soluble gas continuously synthesized by the endothelium. This substance has a wide range of biological properties that maintain vascular homeostasis, including modulation of vascular dilator tone, regulation of local cell growth, and protection of the vessel from injurious consequences of platelets a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Cannon RO 3rd

    更新日期:1998-08-01 00:00:00

  • Ultrasensitive measurement of delta-9-tetrahydrocannabinol with a high energy dynode detector and electron-capture negative chemical-ionization mass spectrometry.

    abstract::Plasma concentrations of delta-9-tetrahydrocannabinol, the principal psychoactive cannabinoid in marijuana, decline to values substantially less than 1 microgram/L within a few hours after a subject has smoked a marijuana cigarette. Using a single-quadrupole gas chromatograph-mass spectrometer (GC/MS) operated in the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shaw LM,Edling-Owens J,Mattes R

    更新日期:1991-12-01 00:00:00

  • High-throughput mitochondrial genome screening method for nonmelanoma skin cancer using multiplexed temperature gradient capillary electrophoresis.

    abstract:BACKGROUND:We explored the utility of multiplexed temperature gradient capillary electrophoresis (TGCE) as a screening tool for identifying genetic changes in the human mitochondrial genome. We examined changes in mitochondrial DNA (mtDNA) in nonmelanoma skin cancers (NMSCs), using TGCE to resolve genetic differences c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.040311

    authors: Girald-Rosa W,Vleugels RA,Musiek AC,Sligh JE

    更新日期:2005-02-01 00:00:00

  • Semi-automated direct colorimetric measurement of creatine kinase isoenzyme MB activity after extraction from serum by use of a CK-MB-specific monoclonal antibody.

    abstract::This semi-automated colorimetric assay for the MB isoenzyme of creatine kinase (EC 2.7.3.2) is based on a monoclonal antibody ("Conan-MB") specific for this isoenzyme and is a modification of a previously published method (Vaidya et al., Clin Chem 1986;32:657-63). A 0.64-cm bead coated with 2 to 3 micrograms of antibo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Landt Y,Vaidya HC,Porter SE,Whalen K,McClellan A,Amyx C,Parvin CA,Kessler G,Nahm MH,Dietzler DN

    更新日期:1988-03-01 00:00:00

  • Quantitative nephelometric assay for determining myoglobin evaluated.

    abstract::A recently introduced automated nephelometric immunoassay involving shell/core particles for determination of myoglobin (Behringwerke) was evaluated with the BNA Nephelometer. Method precision was good: the intra-assay CV varied between 1.5% and 6.1%; with daily calibration, the interassay CV ranged between 1.5% and 7...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delanghe JR,Chapelle JP,Vanderschueren SC

    更新日期:1990-09-01 00:00:00

  • Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone.

    abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052167

    authors: Kushnir MM,Rockwood AL,Roberts WL,Pattison EG,Bunker AM,Fitzgerald RL,Meikle AW

    更新日期:2006-01-01 00:00:00

  • A new assay for diaphorase activity in reagent formulations, based on the reduction of thiazolyl blue.

    abstract::This new assay procedure for diaphorase eliminates problems of high blank rates and nonlinear kinetics associated with other methods. The dye thiazolyl blue tetrazolium bromide is reduced in the presence of NADH and diaphorase to yield a colored formazan, which as maximum absorbance at 560 nm. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Boethling RS,Weaver TL

    更新日期:1979-12-01 00:00:00

  • RNA extraction from archival formalin-fixed paraffin-embedded tissue: a comparison of manual, semiautomated, and fully automated purification methods.

    abstract:BACKGROUND:Formalin-fixed paraffin-embedded (FFPE) tumor material represents a valuable resource for the analysis of RNA-based biomarkers, both in research laboratories and in routine clinical testing. A robust and automated RNA-extraction method with a high sample throughput is required. METHODS:We evaluated extracti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.122572

    authors: Bohmann K,Hennig G,Rogel U,Poremba C,Mueller BM,Fritz P,Stoerkel S,Schaefer KL

    更新日期:2009-09-01 00:00:00

  • MALDI-TOF MS for the diagnosis of infectious diseases.

    abstract:BACKGROUND:First introduced into clinical microbiology laboratories in Europe, MALDI-TOF MS is being rapidly embraced by laboratories around the globe. Although it has multiple applications, its widespread adoption in clinical microbiology relates to its use as an inexpensive, easy, fast, and accurate method for identi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2014.221770

    authors: Patel R

    更新日期:2015-01-01 00:00:00