Simple spectrophotometric determination of urinary albumin by dye-binding with use of bromphenol blue.

Abstract:

:This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g/L. The reaction is pH independent in the physiological range. It is not subject to substantial interference by uric acid, creatinine, calcium, sodium chloride, or bilirubin. The presence of globulins produces a small positive error. Within-run precision (CV) was 4.8, 1.5, and 0.9%, and day-to-day precision was 11.2, 2.0, and 1.9%, for samples containing albumin at about 0.1, 1.0, and 6.0 g/L, respectively. Results by a radial-immunodiffusion method (x) correlated well with those by the proposed method (y): r = 0.986; y = 0.98x + 0.096; n = 64. The method can also be used to detect globulins, such as Bence Jones protein, by measuring the ratio of the absorbance at 30 min to that at 30 s.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Schosinsky KH,Vargas M,Luz Esquivel A,Chavarria MA

subject

Has Abstract

pub_date

1987-02-01 00:00:00

pages

223-6

issue

2 Pt 1

eissn

0009-9147

issn

1530-8561

journal_volume

33

pub_type

杂志文章
  • Improved automated kinetic determination of uric acid in serum by use of uricase/catalase/aldehyde dehydrogenase.

    abstract::The enzymatic determination of serum uric acid by use of uricase, catalase, and aldehyde dehydrogenase according to Haeckel [J. Clin. Chem. Clin Biochem. 14, 101 (1976)] showed interferences from ethanol-converting enzymes, which are present in some patients' sera. We have identified these enzymes as alcohol dehydroge...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bartl K,Brandhuber M,Ziegenhorn J

    更新日期:1979-04-01 00:00:00

  • A semi-automated fluorometric method for total estrogens in pregnancy urine.

    abstract::We report a continuous-flow fluorometric method for total urinary estrogens that involves the Kober reaction, with extraction of the reaction product into dichloroethane containing trichloroacetic acid as described by Hahnel and Jones [Clin. Chim. Acta 16, 185 (1967)]. The dichloroethane extraction gives greater stabi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frye R,Fong PF,Johnson GF,Rock RC

    更新日期:1977-10-01 00:00:00

  • Minimal disease detection and confirmation in hematologic malignancies: combining cell sorting with clonality profiling.

    abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061259

    authors: Zehentner BK,Fritschle W,Stelzer T,Ghirardelli KM,Hunter K,Wentzel C,Bennington R,Hansen CL,Myerson D,Kalnoski M,Wells DA,Loken MR

    更新日期:2006-03-01 00:00:00

  • Sensitive and selective liquid-chromatographic assay of fluoxetine and norfluoxetine in plasma with fluorescence detection after precolumn derivatization.

    abstract::We determined fluoxetine (Prozac) and its major metabolite norfluoxetine in plasma by liquid chromatography with fluorescence detection. After liquid-liquid extraction from 1 mL of plasma, the extract was derivatized at room temperature with dansyl chloride, and the highly fluorescent derivatives were chromatographed ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Suckow RF,Zhang MF,Cooper TB

    更新日期:1992-09-01 00:00:00

  • B-type natriuretic peptide forms within the heart, coronary sinus, and peripheral circulation in humans: evidence for degradation before secretion.

    abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.210435

    authors: Mahagamasekera PG,Ruygrok PN,Palmer SC,Richards AM,Ansell GS,Nicholls MG,Pemberton CJ,Lewis LK,Yandle TG

    更新日期:2014-03-01 00:00:00

  • The tortuous road to the adoption of katal for the expression of catalytic activity by the General Conference on Weights and Measures.

    abstract:BACKGROUND:The "unit" for "enzymic activity" (U = 1 micromol/min) was recommended by the International Union of Biochemistry and Molecular Biology (IUB) in 1961 and is widely used in medical laboratory reports. The general trend in metrology, however, is toward global standardization through defining units coherent wit...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Dybkaer R

    更新日期:2002-03-01 00:00:00

  • Radiolabeled polymerase chain reaction assay for detection of ras oncogene point mutations in tumors.

    abstract::The human ras gene plays a fundamental role in the transduction of extracellular signals to the nucleus, thereby regulating cell growth and differentiation. Point mutations in the ras gene convert it into a transforming oncogene that has been found in many solid and hematologic malignancies. We describe a rapid and se...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Aoki Y,Lee JC,Pillai S,Isselbacher KJ,Rustgi AK

    更新日期:1994-05-01 00:00:00

  • Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomizer furnace.

    abstract::We compared a stabilized-temperature L'vov platform furnace containing an end-heated graphite atomizer (HGA) and transverse Zeeman background-correction system with a side-heated furnace system (transversely heated graphite atomizer; THGA) containing a longitudinal Zeeman background-correction system for the determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bradley C,Leung FY

    更新日期:1994-03-01 00:00:00

  • Changes in biliary (high-molecular-mass) and liver isoforms of alkaline phosphatase after baboon-to-human liver transplantation.

    abstract::We report a case of hyperphosphatasemia in a 35-year-old patient with hepatitis B who underwent an orthotopic xenogeneic liver transplant. Marked increases in total alkaline phosphatase (ALP; EC 3.1.3.1) activity began 5 days posttransplantation (six times human normal) and increased to approximately 17 times normal a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mercer D,Tang M,Marino IR,Demetris A,Fung J,Starzl T,Warty V

    更新日期:1994-07-01 00:00:00

  • Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

    abstract::Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garber CC

    更新日期:1981-08-01 00:00:00

  • Carboxyhemoglobin, cotinine, and thiocyanate assay compared for distinguishing smokers from non-smokers.

    abstract::We compared cotinine, carboxyhemoglobin, and thiocyanate concentrations in blood sampled from 187 cigarette smokers and 181 non-smokers. All three differed significantly between smokers and non-smokers. Cotinine performed best as a test for assessing smoking status, with a sensitivity of 98% as compared with 94% for c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pojer R,Whitfield JB,Poulos V,Eckhard IF,Richmond R,Hensley WJ

    更新日期:1984-08-01 00:00:00

  • Autoimmune endocrinopathies: aspects of pathogenesis and the role of immune assays in investigation and management.

    abstract::It has been hypothesized over many years that the autoimmune endocrine diseases are each due to antigen-specific defects in suppressor (regulatory) T lymphocyte function. There is now increasing evidence in studies of autoimmune thyroid disease and insulin-dependent diabetes mellitus that suppressor cells are activate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Volpé R

    更新日期:1994-11-01 00:00:00

  • Automated measurement of urinary iodine with use of ultraviolet irradiation.

    abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuda K,Namba H,Nomura T,Yokoyama N,Yamashita S,Izumi M,Nagataki S

    更新日期:1995-04-01 00:00:00

  • A tandem mass spectrometry triplex assay for the detection of Fabry, Pompe, and mucopolysaccharidosis-I (Hurler).

    abstract:BACKGROUND:We sought to develop a tandem mass spectrometry assay in which the enzymatic activities of 3 lysosomal enzymes (α-glucosidase, α-galactosidase A, and α-l-iduronidase) could be quantified in dried blood spots by using a single assay buffer. METHODS:A 3-mm dried blood spot punch was incubated in a single assa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.152009

    authors: Duffey TA,Bellamy G,Elliott S,Fox AC,Glass M,Turecek F,Gelb MH,Scott CR

    更新日期:2010-12-01 00:00:00

  • Comparison between immunoturbidimetry, size-exclusion chromatography, and LC-MS to quantify urinary albumin.

    abstract:BACKGROUND:The accurate and precise measurement of urinary albumin is critical, since even minor increases are diagnostically sensitive indicators of renal disease, cardiovascular events, and risk for death. To gain insights into potential measurement biases, we systematically compared urine albumin measurements perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.107508

    authors: Shaikh A,Seegmiller JC,Borland TM,Burns BE,Ladwig PM,Singh RJ,Kumar R,Larson TS,Lieske JC

    更新日期:2008-09-01 00:00:00

  • Faster determination of clottable fibrinogen in human plasma: an improved method and kinetic study.

    abstract::Clottable fibrinogen in human plasma was determined by measuring spectrophotometrically the increase in turbidity with time due to the fibrinogen-fibrin conversion with thrombin. From the maximal absorbance, Amax, at 450 nm obtained 2 min or less after thrombin as added to plasma, we estimated the fibrinogen concentra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Inada Y,Okamoto H,Kanai S,Tamaura Y

    更新日期:1978-02-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots.

    abstract::We have assessed the technical performance and robustness of NycoCard CRP Whole Blood, a near-patient test for C-reactive protein (CRP), when used in realistic daily routine situations in general practice clinics (GPC). Thirteen GPCs participated, five of them with technician staff. From 898 patients, split-sample mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dahler-Eriksen BS,Lassen JF,Petersen PH,Lund ED,Lauritzen T,Brandslund I

    更新日期:1997-11-01 00:00:00

  • Proteomic Discovery and Validation of the Confounding Effect of Heparin Administration on the Analysis of Candidate Cardiovascular Biomarkers.

    abstract:BACKGROUND:Several plasma proteins have been suggested as markers for a variety of cardiovascular conditions but fail to qualify in independent patient cohorts. This may relate to interference of medication on plasma protein concentrations. We used proteomics to identify plasma proteins that changed in concentration wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.282665

    authors: Beck HC,Jensen LO,Gils C,Ilondo AMM,Frydland M,Hassager C,Møller-Helgestad OK,Møller JE,Rasmussen LM

    更新日期:2018-10-01 00:00:00

  • Sample preparation with ion-exchange resin before liquid-chromatographic determination of plasma catecholamines.

    abstract::Estimation of plasma catecholamine concentrations by "high-performance" liquid chromatography, although increasingly used, still presents difficulties. We describe a method for clean-up of plasma samples on cation-exchange resin before they are extracted with alumina. This procedure eliminates many of the interfering ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frayn KN,Maycock PF

    更新日期:1983-07-01 00:00:00

  • Development of a marker of estrogenic exposure in human serum.

    abstract::The deleterious, disruptive effects of estrogen mimics on the endocrine system were discovered after the compounds were released into the environment. Their chemical structure does not obviously resemble that of steroid hormones; hence, their estrogenic effects were totally unexpected. In addition to occupational expo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sonnenschein C,Soto AM,Fernandez MF,Olea N,Olea-Serrano MF,Ruiz-Lopez MD

    更新日期:1995-12-01 00:00:00

  • Ligand assays: from electrophoresis to miniaturized microarrays.

    abstract::The main developments in the "ligand assay" field in which I have been involved are traced. These include the original development of "first generation" competitive assays relying on radiolabeled analyte markers; the development of the first "second generation", noncompetitive (ultrasensitive) methods, which rely on t...

    journal_title:Clinical chemistry

    pub_type: 历史文章,杂志文章

    doi:

    authors: Ekins RP

    更新日期:1998-09-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • Evaluation of a fully automated serum assay for C-terminal cross-linking telopeptide of type I collagen in osteoporosis.

    abstract:BACKGROUND:Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-da...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garnero P,Borel O,Delmas PD

    更新日期:2001-04-01 00:00:00

  • Decreasing sample volume used in the "Sequential Multichannel Analyzer Computerized" (SMAC).

    abstract::We describe modifications to two cartridges, those for alkaline phosphatase and creatinine, on an 18-channel SMAC (Sequential Multichannel Analyzer Computerized), which allow all 18 tests to be run with a commonly prediluted sample. This decreases the required sample size and eliminates the problem of fibrin clots in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stamper R,Robertshaw DM

    更新日期:1980-05-01 00:00:00

  • Determination of some L-3,4-dihydroxyphenylalanine and dopamine metabolites in urine by means of mass fragmentography.

    abstract::We describe a mass-fragmentographic method for determination in urine of the following metabolites of L-3,4-dihydroxyphenylalanine and dopamine: vanillactic acid, 3,4-dihydroxyphenylacetic acid, 3-methoxy-4-hydroxyphenylethanol, and 3,4-dihydroxyphenylethanol. Deuterated analogs were used as internal standards. The me...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Fremouw-Ottevangers DC,van der Meulen J,Wolthers BG,de Vries JA

    更新日期:1978-01-01 00:00:00

  • Pharmacogenomics of tamoxifen therapy.

    abstract:BACKGROUND:Tamoxifen is a standard endocrine therapy for the prevention and treatment of steroid hormone receptor-positive breast cancer. CONTENT:Tamoxifen requires enzymatic activation by cytochrome P450 (CYP) enzymes for the formation of active metabolites 4-hydroxytamoxifen and endoxifen. As compared with the paren...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.121756

    authors: Brauch H,Mürdter TE,Eichelbaum M,Schwab M

    更新日期:2009-10-01 00:00:00

  • Three routine methods for measuring high-density lipoprotein cholesterol compared with the Reference Method.

    abstract::We compared the performance of three methods for quantifying high-density lipoprotein cholesterol (HDL-C) with the Reference Method for HDL-C, using samples with a wide range of triglyceride (TG) concentrations (290-18000 mg/L). All three comparison assays-- utilizing a magnetic dextran sulfate precipitating reagent, ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris N,Galpchian V,Rifai N

    更新日期:1996-05-01 00:00:00

  • Capillary gas-chromatographic determination of urinary homovanillic acid and vanillylmandelic acid.

    abstract::This relatively simple, rapid method for quantification of homovanillic acid (HVA) and vanillylmandelic acid (VMA) involves solvent extraction and capillary gas chromatography. With use of this extraction method, the overall analytical recovery from an aqueous solution is 92.5% for HVA and 79.2% for VMA. 3,4-Dihydroxy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tuchman M,Crippin PJ,Krivit W

    更新日期:1983-05-01 00:00:00

  • Light-chain ratios of immunoglobulins G, A, and M determined by enzyme immunoassay.

    abstract::We describe an enzyme-linked immunosorbent assay for determination of light-chain ratios for IgG, IgA, and IgM in serum. A commercial serum with known overall kappa and lambda concentrations was used as standard. To capture the respective immunoglobulins, we used antibodies to gamma, lambda and mu chains coated onto m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chui SH,Lam CW,Lai KN

    更新日期:1990-03-01 00:00:00