Jendrassik--Grof analysis for total and direct bilirubin in serum with a centrifugal analyzer.

Abstract:

:Total bilirubin is determined here with a multipoint calibration approach and with use of Standard Reference Material No. 916 bilirubin from the National Bureau of Standards. The bilirubin calibration solutions prepared in solutions of Cohn Fraction V human albumin were stable for at least one year when stored at -80 degrees C. Studies for direct bilirubin analysis show that the serum sample should be preincubated with the HCI reagent before the diazo reagent is added to minimize the false reaction with unconjugated bilirubin. With a preincubation of 15 min and a reaction interval of 15 min a 250 mg/L unconjugated bilirubin standard gave only 1 mg of apparent conjugated bilirubin per liter. Day-to-day precision studies gave CVs of 3.3% at 12.4 mg/l, 2.1% at 41.2 mg/l, and 1.0% at 197.4 mg/L for total bilirubin and 1.6% at 61.2 mg/L for direct bilirubin, the latter based on a serum pool stored at -80 degrees C. Lipemic sera caused negligible errors. Hemolysis caused slightly larger errors for total bilirubin but much smaller errors for direct bilirubin when measured at 600 nm rather than 550 nm. Comparison of results with the Rotochem (y) to those with a manual Jendrassik--Grof method (x) for total bilirubin gave y = 0.9009x - 0.04 mg/L, Sy/x = 1.3 mg/L, r = 0.9987 when different calibrators were used for each method and y = 0.9813x - 2.9 mg/L, Sy/x = 1.5 mg/L, r = 0.9997 when the same calibrators were used. For direct-bilirubin comparisons, y = 1.2762x + 0.2 mg/L, Sy/x = 1.3 mg/L, r = 0.9926.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Garber CC

subject

Has Abstract

pub_date

1981-08-01 00:00:00

pages

1410-6

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

27

pub_type

杂志文章
  • Liquid-phase reactions started by rehydrating lyophilized reagents in a centrifugal analyzer.

    abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Truchaud A,Glikmanas G,Gourmelin Y,Hersant J,Trepo D,Foray G,Collombel C

    更新日期:1985-09-01 00:00:00

  • Gas-chromatographic determination of cholesterol sulfate in plasma and erythrocytes, for the diagnosis of recessive X-linked ichthyosis.

    abstract::We describe a rapid method for determining cholesterol sulfate in plasma and erythrocytes. After its single-step isolation by means of anion-exchange chromatography cholesterol sulfate is hydrolyzed, trimethylsilylated, and determined by gas chromatography with flame ionization detection. 5 beta-Cholestan-3 alpha-ol s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Jansen G,Wolthers BG,Marinkovic-Ilsen A,van Voorst Vader PC

    更新日期:1983-07-01 00:00:00

  • Prostate-specific antigen: a cancer fighter and a valuable messenger?

    abstract:BACKGROUND:Prostate-specific antigen (PSA) is a valuable prostatic cancer biomarker that is now widely used for population screening, diagnosis, and monitoring of patients with prostate cancer. Despite the voluminous literature on this biomarker, relatively few reports have addressed the issue of its physiological func...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Diamandis EP

    更新日期:2000-07-01 00:00:00

  • Radioimmunoassay of metanephrine and normetanephrine for diagnosis of pheochromocytoma.

    abstract::Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immun...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iinuma K,Ikeda I,Ogihara T,Hashizume K,Kurata K,Kumahara Y

    更新日期:1986-10-01 00:00:00

  • Enzyme immunoassay of thyroxin-binding globulin.

    abstract::We describe a new double-antibody enzyme radioimmunoassay for thyroxin-binding globulin (TBG) in serum. A TBG-beta-D-galactosidase complex was prepared with m-maleimidobenzoyl N-hydroxysuccinimide ester. The mean analytical recovery of TBG added to serum was 99%, sample volume and TBG value were linearly related, and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miyai K,Ito M,Hata N

    更新日期:1982-12-01 00:00:00

  • A homogeneous fluorescent immunoassay for human immunoglobulin M.

    abstract::We describe a homogeneous substrate-labeled fluorescent immunoassay for human IgM. In this competitive-binding method we use a fluorogenic substrate for Escherichia coli beta-galactosidase, N-(6-aminohexyl)-7-beta-galactosyl-coumarin-3-carboxamide, which is covalently coupled to IgM. The fluorescence emission intensit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Worah D,Yeung KK,Ward FE,Carrico RJ

    更新日期:1981-05-01 00:00:00

  • Serum gentamicin assay by high-performance liquid chromatography.

    abstract::We describe a high-performance liquid chromatographic method for the quantitative determination of gentamicin in serum. The antibiotic was separated from serum by passage through a silicic acid column, derivatized with o-phthalaldehyde, and eluted with ethanol. The derivatized gentamicin was then separated into all th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maitra SK,Yoshikawa TT,Hansen JL,Nilsson-Ehle I,Palin WJ,Schotz MC,Guze LB

    更新日期:1977-12-01 00:00:00

  • Serum prostate-specific acid phosphatase: development and validation of a specific radioimmunoassay.

    abstract::We describe radioimmunoassay for human prostatic acid phosphatase [orthophosphoric-monoester phospho-hydrolase (acid optimum), EC 3.1.3.2] in serum, with use of monospecific antisera raised in rabbits against highly purified acid phosphatase from human prostates. The antiserum did not cross react with partly purified ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vihko P,Sajanti E,Jänne O,Peltonen L,Vihko R

    更新日期:1978-11-01 00:00:00

  • Reappraisal of the uroporphyrinogen I synthase assay, and a proposed modified method.

    abstract::Problems encountered in the uroporphyrinogen I synthase assay were found to be due to the Triton reagent, slit-width and excitation wavelength settings of the spectrophotofluorometer, and leg-phase in the enzyme reaction. Of Triton X-100 from four suppliers, only three were found suitable. Differences in enzyme activi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Chamberlain BR,Buttery JE

    更新日期:1980-08-01 00:00:00

  • Correlation between estrogen receptor protein and carcinoembryonic antigen in normal and carcinomatous human breast tissue.

    abstract::We determined estrogen receptor protein and carcinoembryonic antigen in cytosols prepared from 189 human breast carcinoma tissues, 85 benign or normal breast biopsies, and 101 tissue specimens metastatic from breast carcinoma. Carcinoembryonic antigen was observed in 70% of the primary carcinomatous tissues, 15% of th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Menendez-Botet CJ,Nisselbaum JS,Fleisher M,Rosen PP,Fracchia A,Robbins G,Urban JA,Schwartz MK

    更新日期:1976-08-01 00:00:00

  • Evaluation of two digoxin radioimmunoassay procedures in which 125I-labeled digoxin is used.

    abstract::We present a comparative evaluation of two commercial kits, the "Quantitope" and "GammaCoat," for radioimmunoassay of digoxin in serum. These kits, in which iodine-125 is used as a label, proved to suitable for digoxin assay as determined by their reproducibility, sensitivity, precision, and a regression analysis. Hem...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kuczala ZJ,Ahluwalia GS

    更新日期:1976-02-01 00:00:00

  • SELDI-TOF MS whole serum proteomic profiling with IMAC surface does not reliably detect prostate cancer.

    abstract:BACKGROUND:The analysis of bodily fluids using SELDI-TOF MS has been reported to identify signatures of spectral peaks that can be used to differentiate patients with a specific disease from normal or control patients. This report is the 2nd of 2 companion articles describing a validation study of a SELDI-TOF MS approa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2007.091496

    authors: McLerran D,Grizzle WE,Feng Z,Thompson IM,Bigbee WL,Cazares LH,Chan DW,Dahlgren J,Diaz J,Kagan J,Lin DW,Malik G,Oelschlager D,Partin A,Randolph TW,Sokoll L,Srivastava S,Srivastava S,Thornquist M,Troyer D,Wright GL

    更新日期:2008-01-01 00:00:00

  • Angiotensin-converting enzyme determination in plasma during therapy with converting enzyme inhibitor: two methods compared.

    abstract::For normal and above-normal concentrations of angiotensin-converting enzyme (ACE; EC 3.4.15.1) activity in plasma, results of a manual fluorometric method [with hippuryl-histidyl-leucine (HHL), 5 mmol/L, as substrate] correlated well with those of an automated spectrophotometric method [with 3-(2-furylacryloyl)-L-phen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gorski TP,Campbell DJ

    更新日期:1991-08-01 00:00:00

  • Lithium determinations evaluated in eight analyzers.

    abstract::We compared five ion-selective electrodes (ISEs; AVL 985S, Baxter Lytening 2Z, Beckman EL-ISE, Ciba-Corning 654 Na/K/Li, and Nova CRT 11) and a colorimetric method (Ektachem) for determination of lithium with flame atomic absorption and atomic emission spectroscopy. We evaluated precision, recovery, interference by dr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sampson M,Ruddel M,Elin RJ

    更新日期:1994-06-01 00:00:00

  • Assay of an antitumor protein, neocarzinostatin, and its antibody by fluorescence polarization.

    abstract::I evaluated use of the fluorescence polarization technique to measure neocarzinostatin, a proteinaceous antitumor antibiotic, and its antibody, in serum. The antigen (neocarzinostatin), labeled with fluorescein isothiocyanate, was allowed to interact with its antibody in a cuvet, in the instrument, yielding an increas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Maeda H

    更新日期:1978-12-01 00:00:00

  • Laboratory diagnosis of specific antibody deficiency to pneumococcal capsular polysaccharide antigens.

    abstract:BACKGROUND:Measurement of postimmunization antibody response to pneumococcal capsular polysaccharide (caps-PS) is the standard method to identify deficiency of antipolysaccharide antibody production. However, no standardized criteria have been defined for classification of patients into responders or nonresponders to c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.080051

    authors: Jeurissen A,Moens L,Raes M,Wuyts G,Willebrords L,Sauer K,Proesmans M,Ceuppens JL,De Boeck K,Bossuyt X

    更新日期:2007-03-01 00:00:00

  • Are laboratories reporting serum quantitative hCG results correctly?

    abstract:BACKGROUND:Human chorionic gonadotropin (hCG) is a heterodimeric glycoprotein hormone that exists in multiple forms. Immunoassays commonly used in clinical laboratories measure intact hCG, total beta hCG (intact hCG + hCG free beta-subunit), and/or hCG free beta-subunit. Measurement of serum concentrations of hCG is us...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.098822

    authors: Cao ZT,Rej R

    更新日期:2008-04-01 00:00:00

  • Urinary excretion of some proteins and enzymes during normal pregnancy.

    abstract::Total protein (TP), albumin (Alb), transferrin (TRF), retinol-binding protein (RPB), N-acetyl-beta-glucosaminidase (NAG), alanine aminopeptidase (AAP), gamma-glutamyltransferase (GGT), and creatinine (Cr) were measured in random (untimed) urine samples from 29 nonpregnant women and from pregnant subjects (11 in the fi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cheung CK,Lao T,Swaminathan R

    更新日期:1989-09-01 00:00:00

  • Highly sensitive cholesterol assay with enzymatic cycling applied to measurement of remnant lipoprotein-cholesterol in serum.

    abstract:BACKGROUND:Remnant lipoprotein-cholesterol (RLP-C) concentrations in sera of healthy individuals are very low (0.080-0.437 mmol/L), making conventional cholesterol methods poorly suited to this purpose. We have developed a highly sensitive cholesterol assay (CD method) and applied it to the RLP-C assay. METHODS:The CD...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kishi K,Ochiai K,Ohta Y,Uemura Y,Kanatani K,Nakajima K,Nakamura M

    更新日期:2002-05-01 00:00:00

  • Biological variation of blood acid-base status: consequences for analytical goal-setting and interpretation of results.

    abstract::Analytical, intra-individual, and interindividual components of variation have been determined for pH, pCO2, bicarbonate, base excess, and total CO2 in capillary specimens of whole blood from a cohort of 14 healthy subjects. Calculated analytical goals (SD) are pH less than or equal to 0.008, pCO2 less than or equal t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harding PJ,Fraser CG

    更新日期:1987-08-01 00:00:00

  • Estimation of highly increased concentrations of fetal hemoglobin in Fanconi's anemia.

    abstract::We report a case of Fanconi's anemia with an extremely high proportion of fetal hemoglobin (Hb F). A three-year-old girl with multiple birth defects, mental retardation, and aplastic anemia consistent with Fanconi's anemia showed Hb AF by electrophoresis; the Kleihauer smear showed Hb F in 70% of her erythrocytes. Tot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Krauss JS,Hahn DA,Jonah MH,Trinh M

    更新日期:1985-10-01 00:00:00

  • Radioimmunoassay for detecting hepatitis B core antigen in serum from patients with chronic hepatitis B infection.

    abstract::The core antigen component of hepatitis B virus (HBV), HBcAg, may be used as a marker of viral replication. We describe a radioimmunoassay for HBcAg in serum, and compare results with those by other similar methods. Samples are centrifuged over a sucrose gradient containing 2-mercaptoethanol, and the resulting pellets...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quiroga JA,González O,Carreño V,Mora I,Porres JC,Gutiez J,Hernández-Guío C

    更新日期:1985-06-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Traceability in laboratory medicine.

    abstract:BACKGROUND:In patient and population samples, generation of analytical results that are comparable and independent of the measurement system, time, and location is essential for the utility of laboratory information supplied in healthcare. Obtaining analytical measurement results with such characteristics is the aim of...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.107052

    authors: Vesper HW,Thienpont LM

    更新日期:2009-06-01 00:00:00

  • Interlaboratory comparison of results of erythrocyte protoporphyrin analysis.

    abstract::Each of 65 laboratories analyzed 10 whole-blood samples for erythrocyte protoporphyrin by one or more of several analytical procedures. These procedures were of two types: (a) extraction of protoporphyrin from the erythrocytes into ethyl acetate/acetic acid, re-extraction into hydrochloric acid, and fluorometric measu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jackson KW

    更新日期:1978-12-01 00:00:00

  • Thin-layer chromatographic determination of urinary excretion of lactulose, simplified and applied to cystic fibrosis patients.

    abstract::Urinary excretion of orally administered lactulose is used as an index of intestinal permeability. We have developed a simple thin-layer chromatographic technique for measuring lactulose in urine, using silica gel 60 plates and a propanol-borate solvent system. Lactulose concentrations as low as 62.5 mg/L can be detec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Flick JA,Schnaar RL,Perman JA

    更新日期:1987-07-01 00:00:00

  • Comparing multivariate and univariate subject-specific reference regions for blood constituents in healthy persons.

    abstract::We examined the comparative behavior of subject-specific multivariate and univariate reference regions, using both computer-generated data and serial (semi-annual) measurements of selected analytes in subjects from a large health-maintenance program. Univariate studies under both homeostatic and random-walk time-serie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris EK,Yasaka T,Horton MR,Shakarji G

    更新日期:1982-03-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Effect of use of gel-barrier sampling tubes on determination of some antiepileptic drugs in serum.

    abstract::We evaluated the effect on drug concentration of the duration of sample storage in three different tubes for blood collection: SST (Becton Dickinson), AutoSep (Terumo), and Microvette (Sarstedt), all of which contain an inert barrier (e.g., gel) for cleaner separation of serum from coagulum during centrifugation. With...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bergqvist Y,Eckerbom S,Funding L

    更新日期:1984-03-01 00:00:00

  • Detection and characterization of blocking-type anti-acetylcholine receptor antibodies in sera from patients with myasthenia gravis.

    abstract::We developed a highly sensitive, convenient assay for measuring blocking-type anti-acetylcholine receptor antibodies, which inhibit the binding of 125I-labeled alpha-bungarotoxin (alpha-BuTx) to the acetylcholine receptor (AChR). This procedure detected inhibitory activities in sera from 76% of patients with myastheni...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hara H,Hayashi K,Ohta K,Itoh N,Nishitani H,Ohta M

    更新日期:1993-10-01 00:00:00