Are laboratories reporting serum quantitative hCG results correctly?

Abstract:

BACKGROUND:Human chorionic gonadotropin (hCG) is a heterodimeric glycoprotein hormone that exists in multiple forms. Immunoassays commonly used in clinical laboratories measure intact hCG, total beta hCG (intact hCG + hCG free beta-subunit), and/or hCG free beta-subunit. Measurement of serum concentrations of hCG is useful for confirmation and monitoring of pregnancy, diagnosis of trophoblastic diseases and monitoring of the efficacy of treatment, and prenatal screening. Correctly reporting results for the various forms of hCG is clinically important. METHOD:We prepared samples by addition of intact hCG and hCG free beta-subunit to an essentially hCG-free human serum matrix. The samples were analyzed by participant laboratories using various immunoassay methods. RESULTS:We identified errors in participant reporting of intact hCG results as total beta hCG (9.3%; 22 of 235 laboratories) and total beta hCG as intact hCG (13.1%; 8 of 61 laboratories). CONCLUSIONS:Many factors contribute to the erroneous reporting of hCG results, including (a) the complexity of hCG molecule and confusion of nomenclature on the various forms of hCG; (b) laboratory personnel's lack of awareness of the distinctions of the forms of hCG and failure to recognize the specificity of assays for their measurement; (c) lack of clarity and uniformity in manufacturers' reagent labeling; and (d) most product inserts' lack of information on the specificity of each method to the various forms of hCG.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Cao ZT,Rej R

doi

10.1373/clinchem.2007.098822

subject

Has Abstract

pub_date

2008-04-01 00:00:00

pages

761-4

issue

4

eissn

0009-9147

issn

1530-8561

pii

clinchem.2007.098822

journal_volume

54

pub_type

杂志文章
  • Enzyme conversion immunoassay for determining total homocysteine in plasma or serum.

    abstract::A rapid and precise immunoassay for quantification of total homocysteine in blood samples is presented. The method avoids the use of radioisotopes and chromatographic separations and relies on enzymatic conversion of homocysteine to S-adenosyl-L-homocysteine, followed by quantification of S-adenosyl-L-homocysteine by ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frantzen F,Faaren AL,Alfheim I,Nordhei AK

    更新日期:1998-02-01 00:00:00

  • Serum lipoperoxidation products in an infant with hemolytic-uremic syndrome.

    abstract::We detected increased concentrations of lipoperoxidation products, as malondialdehyde, in the serum of an infant with classic hemolytic-uremic syndrome. The concentrations declined when peritoneal dialysis was initiated and eventually returned to normal after clinical recovery. Our observation adds to the existing bod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Brown RE,Alade SL,Knight JA,Evans BJ

    更新日期:1988-11-01 00:00:00

  • Two-site enzyme immunoassay of CD4 and CD8 molecules on the surface of T lymphocytes from healthy subjects and HIV-1-infected patients.

    abstract::A highly sensitive two-site enzyme immunoassay (Capcellia) was developed to determine the concentration of CD4 and CD8 molecules expressed on the surface of human T lymphocytes. This assay, performed in one step (20 min), involves the specific immunocapture of T lymphocytes and reaction of the CD4 or CD8 molecules wit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Carriere D,Fontaine C,Berthier AM,Rouquette AM,Carayon P,Laprode M,Juillard R,Jansen A,Paoli P,Paolucci F

    更新日期:1994-01-01 00:00:00

  • Clinical evaluation of serial blood processing at point of care.

    abstract::The Axial Separation Module (ASM), which separates whole-blood specimens serially in Axial Process Containers (APC), was evaluated for clinical performance at the University of Virginia Health Sciences Center (UVA HSC) in a community-based outpatient laboratory (North Ridge Clinic). We hypothesized that moving the tas...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Estey CA,Felder RA

    更新日期:1997-02-01 00:00:00

  • Influence of O.C.T. embedding compound on determinations of estrogen and progestin receptors in breast cancer.

    abstract::Estrogen receptor (ER) and progestin receptor (PR) concentrations in tumor biopsies are important predictive indicators of a clinical response to endocrine therapy of breast cancer. To assess interference of O.C.T. (optimum cutting temperature) embedding compound in assays of ER and PR by radioligand binding, we deter...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pasic R,Djulbegovic B,Wittliff JL

    更新日期:1989-12-01 00:00:00

  • Fluorometric method for phenylalanine microplate assay adapted for phenylketonuria screening.

    abstract::We adapted the method of McCaman and Robins for fluorometry of phenylalanine to a microplate assay for routine phenylketonuria screening. Sensitivity is 15 mumol/L for the plasma assay and 30 mumol/L for the dried blood-spot assay, with CV less than 10% for both assays. Results for human plasma by microplate assay cor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gerasimova NS,Steklova IV,Tuuminen T

    更新日期:1989-10-01 00:00:00

  • Radioimmunometric assay for a monoclonal antibody-defined tumor marker, CA 19-9.

    abstract::We describe a solid-phase radioimmunometric sandwich assay for a new tumor marker defined by a monoclonal antibody (19-9). This antibody reacts with a carbohydrate antigenic determinant (CA 19-9) found at low concentrations in sera from healthy individuals but frequently increased in sera from patients with adenocarci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Del Villano BC,Brennan S,Brock P,Bucher C,Liu V,McClure M,Rake B,Space S,Westrick B,Schoemaker H,Zurawski VR Jr

    更新日期:1983-03-01 00:00:00

  • Variability in the relationship between mean plasma glucose and HbA1c: implications for the assessment of glycemic control.

    abstract:BACKGROUND:Previous studies have shown a single linear relationship between mean plasma glucose (MPG) and hemoglobin A(1c) (HbA(1c)). We examined the relationship in different treatment groups of patients with type 1 diabetes participating in the Diabetes Control and Complications Trial (DCCT). METHODS:Seven-point glu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2006.079756

    authors: Kilpatrick ES,Rigby AS,Atkin SL

    更新日期:2007-05-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • Evaluation of homogeneous enzyme immunoassay of serum thyroxine with use of bichromatic analysis.

    abstract::We evaluated the homogeneous enzyme immunoassay ("EMIT") of serum thyroxine with use of an ABA- 100 Bichromatic Analyzer, modified with an auxiliary dispenser syringe and a dual probe assembly. The modification allows two reagents to be dispensed at one time. The sera must be pre-treated with 0.1 mol/liter NaOH. The p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Williams RJ

    更新日期:1978-01-01 00:00:00

  • Single-reagent polarization fluoroimmunoassay for amphetamine in urine.

    abstract::This simple polarization fluoroimmunoassay for detection of amphetamine in urine involves the use of a single reagent: suitably diluted antiserum plus fluorescein-labeled amphetamine as tracer. To this, one adds 10 microL of urine, incubates for a few minutes at room temperature, and measures the fluorescence polariza...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Colbert DL,Gallacher G,Mainwaring-Burton RW

    更新日期:1985-07-01 00:00:00

  • Catalytic concentrations of amylase isoenzymes: an assay with wheat-germ inhibitor and 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate.

    abstract::We coupled a kinetic procedure to a selective inhibiting method for determining amylase isoenzymes in biological samples, using 4-nitrophenylmaltopentaoside plus 4-nitrophenylmaltohexaoside as substrate and a wheat-germ selective inhibitor with the Gilford S-III spectrophotometer. On plotting remaining amylase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jiménez A,Arenas J,Santos I,Martínez A

    更新日期:1986-08-01 00:00:00

  • Clinical and genetic correlates of growth differentiation factor 15 in the community.

    abstract:BACKGROUND:Growth differentiation factor 15 (GDF15), a stress-responsive cytokine produced in cardiovascular cells under conditions of inflammation and oxidative stress, is emerging as an important prognostic marker in individuals with and without existing cardiovascular disease (CVD). We therefore examined the clinica...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2012.190322

    authors: Ho JE,Mahajan A,Chen MH,Larson MG,McCabe EL,Ghorbani A,Cheng S,Johnson AD,Lindgren CM,Kempf T,Lind L,Ingelsson E,Vasan RS,Januzzi J,Wollert KC,Morris AP,Wang TJ

    更新日期:2012-11-01 00:00:00

  • Lateral flow immunoassay using Europium (III) chelate microparticles and time-resolved fluorescence for eosinophils and neutrophils in whole blood.

    abstract:BACKGROUND:A simple point-of-care method for measuring leukocyte counts in a doctor's office or emergency room could be of great importance. We developed a protocol for measuring cell count by disrupting the cell membrane and analyzing specific proteins within the cells and used it to analyze proteins from eosinophils ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.074021

    authors: Rundström G,Jonsson A,Mårtensson O,Mendel-Hartvig I,Venge P

    更新日期:2007-02-01 00:00:00

  • Molar absorptivities of beta-NADH and beta-NAD at 260 nm.

    abstract::To determine the molar absorptivities of beta-NADH and beta-NAD at 260 nm, we purified the reduced form of the coenzyme by repeated anion-exchange chromatography. A NADH preparation was so obtained for which the 260 nm/340 nm absorbance ratio was 2.265. When calculated with epsilon 340 beta-NADH = 6.22 times 10-3 for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Haid E,Lehmann P,Ziegenhorn J

    更新日期:1975-06-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • Accuracy and precision of breath-alcohol measurements for a random subject in the postabsorptive state.

    abstract::The accuracy of estimates of blood-alcohol concentration based on measurements of breath-alcohol concentration in a randomly selected subject by a random quantitative evidential breath-alcohol analyzer is evaluated with respect to the breath analyzer itself, its calibration, and the biological variables of the subject...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simpson G

    更新日期:1987-02-01 00:00:00

  • Increased fetal DNA concentrations in the plasma of pregnant women carrying fetuses with trisomy 21.

    abstract:BACKGROUND:The recent discovery of the presence of circulating cell-free fetal DNA in maternal plasma opens up new prenatal diagnostic applications and provides new avenues for clinical investigation. It is of research and potential diagnostic interest to determine whether fetal trisomy 21 may be associated with quanti...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章,多中心研究

    doi:

    authors: Lo YM,Lau TK,Zhang J,Leung TN,Chang AM,Hjelm NM,Elmes RS,Bianchi DW

    更新日期:1999-10-01 00:00:00

  • Established and emerging markers of kidney function.

    abstract:BACKGROUND:The kidney performs a multitude of essential functions to maintain homeostasis. In clinical medicine, glomerular filtration rate (GFR) provides the best index of overall kidney function, and proteinuria adds additional information on renal and nonrenal prognosis. Several novel biomarkers of kidney injury and...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2011.167494

    authors: Ferguson MA,Waikar SS

    更新日期:2012-04-01 00:00:00

  • Oligosaccharide analysis in urine by maldi-tof mass spectrometry for the diagnosis of lysosomal storage diseases.

    abstract:BACKGROUND:There are 45 known genetic diseases that impair the lysosomal degradation of macromolecules. The loss of a single lysosomal hydrolase leads to the accumulation of its undegraded substrates in tissues and increases of related glycoconjugates in urine, some of which can be detected by screening of free oligosa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.201053

    authors: Xia B,Asif G,Arthur L,Pervaiz MA,Li X,Liu R,Cummings RD,He M

    更新日期:2013-09-01 00:00:00

  • Bioinformatics for clinical next generation sequencing.

    abstract:BACKGROUND:Next generation sequencing (NGS)-based assays continue to redefine the field of genetic testing. Owing to the complexity of the data, bioinformatics has become a necessary component in any laboratory implementing a clinical NGS test. CONTENT:The computational components of an NGS-based work flow can be conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2014.224360

    authors: Oliver GR,Hart SN,Klee EW

    更新日期:2015-01-01 00:00:00

  • Multi-channel, probe colorimeter for use with the micr-ELISA test, which makes use of disposable flat-bottom microhemagglutination plates.

    abstract::We describe a multiprobe colorimeter that permits the reading of enzyme-linked immunosorbent assays (ELISA) in situ, by use of microhemagglutination plates. The use of dipping probes eliminates interference from meniscus effects and air-bubble entrapment. Detailed validation tests have been done and potential sources ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McMurray CH,Blanchflower WJ

    更新日期:1979-04-01 00:00:00

  • Evaluation of the Beckman creatinine analyzer.

    abstract::We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hicks JM,Iosefsohn M,Lewis SA

    更新日期:1979-06-01 00:00:00

  • Meconium nicotine and metabolites by liquid chromatography-tandem mass spectrometry: differentiation of passive and nonexposure and correlation with neonatal outcome measures.

    abstract:BACKGROUND:Meconium analysis is a diagnostically sensitive and objective alternative to maternal self-report for detecting prenatal tobacco exposure. Nicotine and metabolite disposition in meconium is poorly characterized, and correlation of analytes' concentrations with neonatal outcomes is unexplored. Our objectives ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.109173

    authors: Gray TR,Magri R,Shakleya DM,Huestis MA

    更新日期:2008-12-01 00:00:00

  • Development of a homogeneous assay for measurement of small dense LDL cholesterol.

    abstract:BACKGROUND:Plasma concentrations of small dense (sd)-LDL are associated with the prevalence of cardiovascular events. However, the special equipment and long assay times required for sd-LDL measurement have hindered its clinical application. Herein, we report development of a simple homogeneous assay for sd-LDL-cholest...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.149559

    authors: Ito Y,Fujimura M,Ohta M,Hirano T

    更新日期:2011-01-01 00:00:00

  • Induced gene transcription: implications for biomarkers.

    abstract::Numerous xenobiotics regulate cellular functions by altering transcription of target genes. Use of sensitive and specific biomarkers based on gene transcript levels may help clarify the shape of the dose-response curve in the low-dose region associated with human exposures to environmental concentrations of chemicals....

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Sewall CH,Bell DA,Clark GC,Tritscher AM,Tully DB,Vanden Heuvel J,Lucier GW

    更新日期:1995-12-01 00:00:00

  • Plasma protein abnormalities in nephrotic syndrome: effect on plasma colloid osmotic pressure and viscosity.

    abstract::The concentrations of 25 plasma proteins were measured in 22 patients with membranous nephropathy. For some large proteins, the plasma concentrations were increased; there were also large proteins with low plasma concentrations, but small or medium-sized proteins showed uniformly lower plasma concentration than the co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Joven J,Clivillé X,Camps J,Espinel E,Simó J,Vilella E,Oliver A

    更新日期:1997-07-01 00:00:00

  • Assays for thyrotropin-receptor binding and thyroid-stimulating antibodies in sera from patients with Graves' disease.

    abstract::We compared the activities of thyroid-stimulating antibodies (TSAb) measured in cultures of human thyrocytes and the values for thyrotropin-receptor antibodies (TRAb) as measured with a commercial kit based on use of radiolabeled receptors. Sera were obtained from patients with Graves' disease before, during, and afte...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Massart C,Hody B,Mouchel L,Edan G,Nicol M

    更新日期:1986-07-01 00:00:00

  • Modification of intra-erythrocytic homeostasis in uremic patients, as studied with 31P nuclear magnetic resonance.

    abstract::Intra-erythrocytic pH, ATP concentrations, and 2,3-diphosphoglycerate relaxation times were studied in living erythrocytes by "high-resolution" 31P NMR spectroscopy to assess homeostasis within the cells. In uremic patients, intra-erythrocytic pH is significantly decreased before hemodialysis, but is corrected equally...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Monti JP,Gallice P,Baas M,Murisasco A,Crevat A

    更新日期:1987-01-01 00:00:00