Abstract:
BACKGROUND:Meconium analysis is a diagnostically sensitive and objective alternative to maternal self-report for detecting prenatal tobacco exposure. Nicotine and metabolite disposition in meconium is poorly characterized, and correlation of analytes' concentrations with neonatal outcomes is unexplored. Our objectives were to quantify nicotine, cotinine, trans-3'-hydroxycotinine (OH-cotinine), nornicotine, norcotinine, and glucuronide concentrations in meconium, identify the best biomarkers of in utero tobacco exposure, compare meconium concentrations of tobacco-exposed and nonexposed neonates, and investigate concentration-outcome relationships. METHODS:We quantified concentrations of nicotine and 4 metabolites with and without hydrolysis simultaneously in meconium from tobacco-exposed and nonexposed neonates by liquid chromatography-tandem mass spectrometry. We compared meconium concentrations to birth weight, length, head circumference, gestational age, and 1- and 5-min Apgar scores. RESULTS:Nicotine, cotinine, and OH-cotinine were the most prevalent and abundant meconium tobacco biomarkers and were found in higher concentrations in tobacco-exposed neonates. Whereas cotinine and OH-cotinine are glucuronide bound, performing the lengthy and costly enzymatic hydrolysis identified only 1 additional positive specimen. Unconjugated nicotine, cotinine, or OH-cotinine meconium concentration >10 ng/g most accurately discriminated active from passive and nonexposed neonates. There was no significant correlation between quantitative nicotine and metabolite meconium results and neonatal outcomes, although presence of a nicotine biomarker predicted decreased head circumference. CONCLUSIONS:Unconjugated nicotine, cotinine, and OH-cotinine should be analyzed in meconium to detect in utero tobacco exposure, as approximately 25% of positive specimens did not contain cotinine. Immunoassay testing monitoring cotinine only would underestimate the prevalence of prenatal tobacco exposure.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Gray TR,Magri R,Shakleya DM,Huestis MAdoi
10.1373/clinchem.2008.109173subject
Has Abstractpub_date
2008-12-01 00:00:00pages
2018-27issue
12eissn
0009-9147issn
1530-8561pii
clinchem.2008.109173journal_volume
54pub_type
杂志文章abstract:BACKGROUND:Late enhancement MRI (LE-MRI) and cardiac troponin I (cTnI) are sensitive methods to detect subclinical myocardial injury. We sought to investigate the relation between plasma concentrations of cTnI measured with a high-sensitivity assay (hs-cTnI) and the development of unrecognized myocardial infarctions (U...
journal_title:Clinical chemistry
pub_type: 杂志文章,随机对照试验
doi:10.1373/clinchem.2014.222430
更新日期:2014-10-01 00:00:00
abstract:BACKGROUND:Published literature was systematically reviewed to determine the diagnostic accuracy of new protein markers of acute coronary syndromes (ACS) in symptomatic outpatients at low risk of ACS and related complications comparable to patients evaluated in emergency department chest pain units. METHODS:Studies we...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2005.052456
更新日期:2005-11-01 00:00:00
abstract::Medium-chain acyl-CoA dehydrogenase (MCAD) deficiency is a recessively inherited defect in the mitochondrial beta-oxidation of fatty acids. A single nucleotide change, the A985 --> G transition, in the MCAD gene accounts for approximately 90% of all the disease-causing mutations in the patients. We have used PCR to am...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-01-01 00:00:00
abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-07-01 00:00:00
abstract::Clinicians experience difficulty in correctly interpreting the results of in vitro thyroid function tests in the presence of abnormalities of thyrobinding proteins or when results are borderline. This difficulty has been largely resolved in our laboratory by three innovations. First, the borderline areas for each of t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract:BACKGROUND:A unique requirement for the molecular diagnosis of mitochondrial DNA (mtDNA) disorders is the ability to detect heteroplasmic mtDNA mutations and to distinguish them from homoplasmic sequence variations before further testing (e.g., sequencing) is performed. We evaluated the potential utility of temporal te...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-08-01 00:00:00
abstract::For normal and above-normal concentrations of angiotensin-converting enzyme (ACE; EC 3.4.15.1) activity in plasma, results of a manual fluorometric method [with hippuryl-histidyl-leucine (HHL), 5 mmol/L, as substrate] correlated well with those of an automated spectrophotometric method [with 3-(2-furylacryloyl)-L-phen...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1991-08-01 00:00:00
abstract:BACKGROUND:Associations between dairy intake and body composition and cardiometabolic traits have been inconsistently observed in epidemiological studies, and the causal relationship remains ill-defined. METHODS:We performed Mendelian randomization analysis using an established genetic variant located upstream of the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2018.300335
更新日期:2019-06-01 00:00:00
abstract::We have reported (Clin Chem 29: 42-44, 1983) that prestaining with Remazol Brilliant Blue permits direct visualization of serum components on disc electrophoresis, and apparently purifies the proteins well. Here we have cut out the bands corresponding to the prestained albumin and transferrin after disc electrophoresi...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1984-07-01 00:00:00
abstract:BACKGROUND:Little is known about lipoprotein(a) [Lp(a)] as a predictor of vascular events among ethnic Chinese. We prospectively investigated the association of Lp(a) with cardiovascular disease and all-cause death in a community-based cohort. METHODS:We conducted a community-based prospective cohort study of 3484 par...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.090969
更新日期:2008-02-01 00:00:00
abstract::A sensitive method, inductively coupled plasma atomic emission spectroscopy, is used to measure desferrioxamine in blood plasma. The desferrioxamine is transformed into its iron chelate, ferrioxamine, which is extracted into benzyl alcohol, then re-extracted into HCl (0.5 mol/L), which is used as the sample for the sp...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-01-01 00:00:00
abstract::We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-star...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-06-01 00:00:00
abstract::To determine the molar absorptivities of beta-NADH and beta-NAD at 260 nm, we purified the reduced form of the coenzyme by repeated anion-exchange chromatography. A NADH preparation was so obtained for which the 260 nm/340 nm absorbance ratio was 2.265. When calculated with epsilon 340 beta-NADH = 6.22 times 10-3 for ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-06-01 00:00:00
abstract::Phenobarbital and phenytoin are extracted and concentrated in a single step, without solvent evaporation, followed by on-column methylation and gas-chromatographic quanitation. A similar extraction step for the assay of theophylline by high-pressure liquid chromatography is described. The extraction step can be comple...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-09-01 00:00:00
abstract::Four commercial products for urine glucose determination were evaluated and compared with a quantitative hexokinase procedure. We examined precision, sensitivity, and analytical recovery of glucose from glucose-supplemented urine samples and comparison of methods, using patients' samples. Only "Chemstrip uG" (Bio-Dyna...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-10-01 00:00:00
abstract:BACKGROUND:Rapid intraoperative parathyroid hormone (PTH) measurements are an important prerequisite for minimally invasive parathyroidectomy, serving as a feasible marker for "cure" because of the short half-life of PTH. Because automated analysis may facilitate monitoring, two automated PTH assays were compared with ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2002-10-01 00:00:00
abstract::Methods are described for detection of lactate dehydrogenase (LDH) inhibitors in preparations of reduced nicotinamide adenine dinucleotide. They are (a) comparison of values by kinetic methods with those measured for highly purified NADH and (b) examination of Lineweaver-Burk plots. Chromatographic inhomogeneities are...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-10-01 00:00:00
abstract::Highly purified human lactate dehydrogenase 1 has been used in an interlaboratory evaluation and improvement progran in clinical chemistry in New York State since 1971. Although there are difficulties in determining and assigning the most nearly accurate values for test samples in the absence of a reference method and...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-06-01 00:00:00
abstract::We describe a new, specific, quantitative method for fecal blood, based on conversion of nonfluorescing heme to fluorescing porphyrins, that obviates serious deficiencies inherent in currently used tests. A two-reagent system is used to determine the two hemoglobin-related fractions that are found in feces. The hot ci...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-12-01 00:00:00
abstract::We studied the specificity of kinetic methods of analysis, with emphasis on creatinine determination. The error contributed by an interferent that reacts with the analytical reagent and absorbs at the wavelength of analysis is shown to be related to the ratio of the equilibrium absorbances of the analyte and interfere...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-04-01 00:00:00
abstract::Nitric oxide is too short-lived to measure in vivo, but its production can be estimated by measuring its stable oxidation products, nitrites and nitrates, in serum. Renal elimination of these ions has been demonstrated, but the effect of renal function on their concentrations in serum is currently unknown. We evaluate...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-03-01 00:00:00
abstract::C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly dep...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-04-01 00:00:00
abstract::We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single c...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-08-01 00:00:00
abstract::We recently proposed a quantitative PCR procedure for the absolute measurement of c-erbB-2 oncogene amplification, based on the simultaneous polymerase chain reaction (PCR) amplification of the target gene and of a competitor DNA molecule acting as internal standard. To increase the number of assayable oncogenes and t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-06-01 00:00:00
abstract::We developed an enzyme-linked immunosorbent assay (ELISA) system for antibodies to the hepatitis C virus (HCV), using two new recombinant antigens (c11 and c7) derived from the HCV genome. The performance of this ELISA system (Imucheck HCV Ab) was examined. The CV values for both intra-assay precision and reproducibil...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-12-01 00:00:00
abstract::An electrospray ionization-mass spectrometric procedure has been developed for determining glycohemoglobin. Whole-blood samples from 78 diabetic and 50 nondiabetic subjects (glycation range 3-15%, as determined by electrospray mass spectrometry) were diluted 500-fold in an acidic denaturing solvent and introduced dire...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-05-01 00:00:00
abstract:BACKGROUND:Kallikrein-related peptidase 6 (KLK6), a member of the serine protease family of kallikrein (KLK) genes, is dysregulated in ovarian carcinomas (OCa) and its overexpression is associated with poor prognosis. Regulation of its expression is poorly understood and is likely to be influenced by multiple mechanism...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2012.193060
更新日期:2013-01-01 00:00:00
abstract::Erythromycin, phenazopyridine, methenamine mandelate, acetazolamide, and ascorbic acid reportedly interfere with the Porter-Silber reaction in the determination of urinary 17-hydroxycorticosteroids. Sodium bisulfite, added to the urine after hydrolysis with glucuronidase, removed almost all nonsteroidal interferences ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-11-01 00:00:00
abstract:BACKGROUND:The alteration of the bone microenvironment as a consequence of skeletal metastases is poorly understood. The aim of this study was to search for patterns of bone markers in relation to primary tumor type, bone pain, and number of sites involved in patients with bone metastases. METHODS:We studied 323 patie...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-08-01 00:00:00
abstract::The commonly used methods of assessing the precision of the automated leukocyte differential have certain drawbacks that affect the validity and comparability of results. In the present report, we introduce a procedure based on building precision profiles from a large number of within-run imprecision experiments. The ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-07-01 00:00:00