Removal of interference by erythromycin, phenazopyridine, and methenamine mandelate in the Porter-Silber reaction.

Abstract:

:Erythromycin, phenazopyridine, methenamine mandelate, acetazolamide, and ascorbic acid reportedly interfere with the Porter-Silber reaction in the determination of urinary 17-hydroxycorticosteroids. Sodium bisulfite, added to the urine after hydrolysis with glucuronidase, removed almost all nonsteroidal interferences in urine from healthy adults medicated with the first three drugs, but such studies proved that acetazolamide and ascorbic acid do not interfere with the Porter--Silber reaction, whether or not sodium bisulfite is added.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Furuya E

subject

Has Abstract

pub_date

1977-11-01 00:00:00

pages

2136-8

issue

11

eissn

0009-9147

issn

1530-8561

journal_volume

23

pub_type

杂志文章
  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • Delayed cytokine mRNA expression kinetics after T-lymphocyte costimulation: a quantitative measure of the efficacy of cyclosporin A-based immunosuppression.

    abstract:BACKGROUND:Because cyclosporin A (CsA) and glucocorticoids inhibit the production of interleukin-2 (IL-2) and other cytokines, quantitative analysis of cytokine mRNA might constitute a pharmacodynamic measure for immunosuppressive drug effects. We investigated whether immunosuppressive drugs influence cytokine mRNA exp...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Härtel C,Fricke L,Schumacher N,Kirchner H,Müller-Steinhardt M

    更新日期:2002-12-01 00:00:00

  • Analytical approaches of European Union laboratories to drugs of abuse analysis.

    abstract::We report a survey on urine drug testing within a total of 269 laboratories of the European Union. Clinical laboratories predominated over forensic laboratories (59.5% vs 28.5%). Screening without identification/quantification was the common approach used by clinical laboratories, whereas screening with identification...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Badia R,de la Torre R,Corcione S,Segura J

    更新日期:1998-04-01 00:00:00

  • Comparison of specific gravity and creatinine for normalizing urinary reproductive hormone concentrations.

    abstract:BACKGROUND:Specific gravity (SG) may perform as well as creatinine (CR) correction for adjusting urinary hormone concentrations, as well as offer some advantages. We compared the two methods and applied them to US and Bangladeshi specimens to evaluate their use in different populations. METHODS:Pearson correlations be...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.032292

    authors: Miller RC,Brindle E,Holman DJ,Shofer J,Klein NA,Soules MR,O'Connor KA

    更新日期:2004-05-01 00:00:00

  • Activity assays and immunoassays for plasma Renin and prorenin: information provided and precautions necessary for accurate measurement.

    abstract:BACKGROUND:Measurement of plasma renin is important for the clinical assessment of hypertensive patients. The most common methods for measuring plasma renin are the plasma renin activity (PRA) assay and the renin immunoassay. The clinical application of renin inhibitor therapy has thrown into focus the differences in i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2008.118000

    authors: Campbell DJ,Nussberger J,Stowasser M,Danser AH,Morganti A,Frandsen E,Ménard J

    更新日期:2009-05-01 00:00:00

  • Comparison of double- and single-isotope enzymatic derivative methods for measuring catecholamines in human plasma.

    abstract::We directly compared the reliability of a single-isotope enzymatic derivative technique for measurement of plasma catecholamines with that of the well-established double-isotope method. A significant (p less than 0.001) correlation was observed between measurements (n = 52) in the two assays, both for norepinephrine (...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Evans MI,Halter JB,Porte D Jr

    更新日期:1978-04-01 00:00:00

  • Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

    abstract:BACKGROUND:The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS:We tested 18 specimens after centrifuga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.6.935

    authors: Grenache DG,Parvin CA,Gronowski AM

    更新日期:2003-06-01 00:00:00

  • Ten electrophoretic methods compared with a selected method for quantifying lactate dehydrogenase isoenzymes in serum.

    abstract::Using the Selected Method of McKenzie and Henderson (Selected Methods Clin Chem 1983;10:59-67) as a reference method, we compared the performance of 10 commercially available methods for determination of lactate dehydrogenase (LD, EC 1.1.1.27) isoenzymes. Results were expressed as percentage of total LD activity, as d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moses GC,Ross ML,Henderson AR

    更新日期:1988-09-01 00:00:00

  • Blood loss from laboratory tests.

    abstract:BACKGROUND:Laboratory tests can be an important source of blood loss in hospitals, especially for newborns and patients in intensive care. The aim of this study was to quantify blood loss for laboratory diagnostic tests in a large number of patients in a teaching hospital. METHODS:We estimated blood loss by multiplyin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.10.1651

    authors: Wisser D,van Ackern K,Knoll E,Wisser H,Bertsch T

    更新日期:2003-10-01 00:00:00

  • Multiple-reaction monitoring-mass spectrometric assays can accurately measure the relative protein abundance in complex mixtures.

    abstract:BACKGROUND:Mass spectrometric assays could potentially replace protein immunoassays in many applications. Previous studies have demonstrated the utility of liquid chromatography-multiple-reaction monitoring-mass spectrometry (LC-MRM/MS) for the quantification of proteins in biological samples, and many examples of the ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.173856

    authors: Hoofnagle AN,Becker JO,Oda MN,Cavigiolio G,Mayer P,Vaisar T

    更新日期:2012-04-01 00:00:00

  • Specific assay of serum lactate dehydrogenase isoenzyme 1 by proteolysis with alpha-chymotrypsin and protein denaturation.

    abstract::We devised a method for assaying serum lactate dehydrogenase isoenzyme 1 (LD-1) activity specifically by preincubation with alpha-chymotrypsin and guanidine. Cleavage of phenylalanine bonds in the loop of A and B subunits of LD-3, LD-4, and LD-5 isoenzymes (residues 117-119) by incubation with alpha-chymotrypsin for a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shirahase Y,Watazu Y,Kaneda N,Uji Y,Okabe H,Karmen A

    更新日期:1992-11-01 00:00:00

  • Microsatellite instability detection by next generation sequencing.

    abstract:BACKGROUND:Microsatellite instability (MSI) is a useful phenotype in cancer diagnosis and prognosis. Nevertheless, methods to detect MSI status from next generation DNA sequencing (NGS) data are underdeveloped. METHODS:We developed an approach to detect the MSI phenotype using NGS (mSINGS). The method was used to eval...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.223677

    authors: Salipante SJ,Scroggins SM,Hampel HL,Turner EH,Pritchard CC

    更新日期:2014-09-01 00:00:00

  • Myoglobin concentration, creatine kinase activity, and creatine kinase B subunit concentrations in serum during thyroid disease.

    abstract::Changes in values for myoglobin, total creatine kinase (EC 2.7.3.2), and creatine kinase B-subunit in the serum of patients with thyroid disease are compared with values for these during the 24-h after myocardial infarction. Concentrations of all three of these muscle-derived proteins were significantly higher than no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Docherty I,Harrop JS,Hine KR,Hopton MR,Matthews HL,Taylor CJ

    更新日期:1984-01-01 00:00:00

  • Liquid-chromatographic measurement of taurine in cerebrospinal fluid of normal individuals and patients with meningitis.

    abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,White JP

    更新日期:1979-08-01 00:00:00

  • Real-time PCR assays targeting a unique chromosomal sequence of Yersinia pestis.

    abstract:BACKGROUND:Yersinia pestis, the causative agent of the zoonotic infection plague, is a major concern as a potential bioweapon. Current real-time PCR assays used for Y. pestis detection are based on plasmid targets, some of which may generate false-positive results. METHODS:Using the yp48 gene of Y. pestis, we designed...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051839

    authors: Chase CJ,Ulrich MP,Wasieloski LP Jr,Kondig JP,Garrison J,Lindler LE,Kulesh DA

    更新日期:2005-10-01 00:00:00

  • Anion-exchange chromatographic determination of bromide in serum.

    abstract::In this liquid-chromatographic method for the determination of bromide in human serum, an important and unique feature is pre-analysis ultrafiltration of the sample, which effectively removes proteins. The chromatographic system consists of an anion-exchange column (Whatman Partisil SAX 10-micron particles), an isocra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller ME,Cappon CJ

    更新日期:1984-05-01 00:00:00

  • Performance of the Hitachi 705 evaluated.

    abstract::We evaluated a new discrete analyzer, the Hitachi 705. The instrument can process sequentially as many as 19 different enzymes or other analytes, with a throughput of 180 tests per hour. We evaluated the spectrophotometer, the sample and reagent probes, and the performance for 11 assays: creatine kinase, aspartate ami...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Douville P,Forest JC

    更新日期:1983-04-01 00:00:00

  • Flow-injection analysis with chemiluminescence detection.

    abstract::In "flow-injection analysis," the sample is inserted into a stream of reagent by use of a sample-injection valve. Mixing occurs downstream from the valve in a coil of tubing. With chemiluminescence detection this coil is positioned in front of a photomultiplier. We have evaluated the system for detection of hydrogen p...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rule G,Seitz WR

    更新日期:1979-09-01 00:00:00

  • A two-step radioimmunoassay for free triiodothyronine in serum.

    abstract::Using a high-affinity solid-phase-bound antibody (Ka = 1.2 X 10(11) L/mol), we have standardized a two-step radioimmunoassay for free triiodothyronine (FT3) in serum, based on immunoextraction. The method was validated by comparison with an equilibrium-dialysis procedure (r = 0.96) involving RIA of T3 in the dialysate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rajan MG,Samuel AM

    更新日期:1987-03-01 00:00:00

  • Use of the laboratory in prediction of outcome in the high-risk newborn.

    abstract::This paper reviews our ability to predict survival and neurodevelopmental outcome in the newborn period. Traditionally, prognosis is based on individual risk factors or disease states. The laboratory plays an important role in diagnosing some of these. For example, prenatal and newborn screening are important in the d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Synnes AR

    更新日期:1997-01-01 00:00:00

  • Estimate of uncertainty of measurement from a single-laboratory validation study: application to the determination of lead in blood.

    abstract:BACKGROUND:Lead is an environmental pollutant, and human exposure is assessed by monitoring lead concentrations in blood. Because the main source of environmental exposure has been the use of leaded gasoline, its phase-out has led to decreased lead concentrations in the general population. Therefore, validated analytic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.029223

    authors: Patriarca M,Castelli M,Corsetti F,Menditto A

    更新日期:2004-08-01 00:00:00

  • Denaturing gradient-gel electrophoresis screening of familial defective apolipoprotein B-100 in a mixed Asian cohort: two cases of arginine3500-->tryptophan mutation associated with a unique haplotype.

    abstract::The Arg-to-Trp substitution at codon 3500 in the apolipoprotein (apo) B-100 gene is established as a cause of familial defective apo B-100 (FDB), a functional mutation, resulting in reduced LDL receptor binding and manifest hypercholesterolemia. In a search for similar mutations in 163 Malaysians, we screened the puta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Choong ML,Koay ES,Khoo KL,Khaw MC,Sethi SK

    更新日期:1997-06-01 00:00:00

  • Quantification of tau in cerebrospinal fluid by immunoaffinity enrichment and tandem mass spectrometry.

    abstract:BACKGROUND:Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.216515

    authors: McAvoy T,Lassman ME,Spellman DS,Ke Z,Howell BJ,Wong O,Zhu L,Tanen M,Struyk A,Laterza OF

    更新日期:2014-04-01 00:00:00

  • Stable-isotope dilution liquid chromatography-electrospray injection tandem mass spectrometry method for fast, selective measurement of S-adenosylmethionine and S-adenosylhomocysteine in plasma.

    abstract:BACKGROUND:It has been postulated that changes in S-adenosylhomocysteine (AdoHcy), a potent inhibitor of transmethylation, provide a mechanism by which increased homocysteine causes its detrimental effects. We aimed to develop a rapid and sensitive method to measure AdoHcy and its precursor S-adenosylmethionine (AdoMet...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046995

    authors: Gellekink H,van Oppenraaij-Emmerzaal D,van Rooij A,Struys EA,den Heijer M,Blom HJ

    更新日期:2005-08-01 00:00:00

  • Immunological measurement of transferrin compared with chemical measurement of total iron-binding capacity.

    abstract::Because of uncertainty as to the molecular weight of transferrin, a previous comparison [Von der Heul et al., Clin. Chim. Acta 38, 347 (1972)] between transferrin content of serum and total iron-binding capacity cannot be definitive. We found a conversion factor for expressing the maximum amount of iron bound by 1 mg ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsung SH,Rosenthal WA,Milewski KA

    更新日期:1975-07-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

  • Biochemical and genetic markers of iron status and the risk of coronary artery disease: an angiography-based study.

    abstract:BACKGROUND:Iron may promote coronary atherosclerotic disease (CAD) by increasing lipid peroxidation. Studies on biochemical or genetic markers of body iron stores as risk factors for CAD have yielded conflicting results. METHODS:We studied 849 individuals with a clear-cut definition of the CAD phenotype, i.e., with (C...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bozzini C,Girelli D,Tinazzi E,Olivieri O,Stranieri C,Bassi A,Trabetti E,Faccini G,Pignatti PF,Corrocher R

    更新日期:2002-01-01 00:00:00

  • Quality assurance, accreditation, and certification: needs and possibilities.

    abstract::Demonstrable quality of laboratory services entails two parts. First, one needs a quality policy statement, identification of user needs, choice of measurement procedures, reference measurement system to provide traceability, control materials, and proficiency testing with materials having reference-measurement-assign...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Dybkaer R

    更新日期:1994-07-01 00:00:00

  • Assessment of vitamin D status in male osteoporosis.

    abstract:BACKGROUND:Clinical assessment of vitamin D status often relies on measuring total circulating 25-hydroxyvitamin D3 (25OHD3), but much of each vitamin D metabolite is bound to plasma vitamin D-binding protein (DBP), such that the percentage of free vitamin is very low. We hypothesized that measurement of free rather th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.059568

    authors: Al-oanzi ZH,Tuck SP,Raj N,Harrop JS,Summers GD,Cook DB,Francis RM,Datta HK

    更新日期:2006-02-01 00:00:00

  • Is determination of creatine kinase-2 after electrophoretic separation accurate?

    abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Henderson AR,Stark JA,McQueen MJ,Patten RL,Krishnan S,Wood DE,Webb S

    更新日期:1994-02-01 00:00:00