Myoglobin concentration, creatine kinase activity, and creatine kinase B subunit concentrations in serum during thyroid disease.

Abstract:

:Changes in values for myoglobin, total creatine kinase (EC 2.7.3.2), and creatine kinase B-subunit in the serum of patients with thyroid disease are compared with values for these during the 24-h after myocardial infarction. Concentrations of all three of these muscle-derived proteins were significantly higher than normal in patients with primary hypothyroidism, and declined with treatment. Values for total creatine kinase activity were below-normal in hyperthyroid patients, but increased after treatment. Values for total creatine kinase and, to a lesser extent, myoglobin in hypothyroidism extend into the range of values observed after myocardial infarction. The mechanism of the changes in these analytes in hypothyroidism may be related to increased leakage from skeletal-muscle cells or diminished clearance from the circulation, or both.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Docherty I,Harrop JS,Hine KR,Hopton MR,Matthews HL,Taylor CJ

subject

Has Abstract

pub_date

1984-01-01 00:00:00

pages

42-5

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

30

pub_type

杂志文章
  • Ultracentrifugation in swinging-bucket and fixed-angle rotors evaluated for isolation and determination of high-density lipoprotein subfractions HDL2 and HDL3.

    abstract::We evaluated the density-gradient ultracentrifugation method in a swinging-bucket rotor (Anal Biochem 111, 149-157, 1981) in a slightly modified version for isolation and determination of high-density lipoprotein (HDL) subfractions. We prestained the serum with Coomassie Brilliant Blue R, which did not change the hydr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Demacker PN,van Sommeren-Zondag DF,Stalenhoef AF,Stuyt PM,van't Laar A

    更新日期:1983-04-01 00:00:00

  • Thyroid function during pregnancy.

    abstract:BACKGROUND:This Case Conference reviews the normal changes in thyroid activity that occur during pregnancy and the proper use of laboratory tests for the diagnosis of thyroid dysfunction in the pregnant patient. CASE:A woman in the 18th week of pregnancy presented with tachycardia, increased blood pressure, severe vom...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Fantz CR,Dagogo-Jack S,Ladenson JH,Gronowski AM

    更新日期:1999-12-01 00:00:00

  • Analytical goals developed from the inherent error of medical tests.

    abstract::Biological variation is inherent in all medical tests and is a major source of error in clinical test interpretation. We use inherent test error due to biological variability as the touchstone by which to validate the clinical acceptability of analytical goals. Analytical goals should consist of sets of complementary ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ross JW,Fraser MD

    更新日期:1993-07-01 00:00:00

  • Affinity binding assay of glycohemoglobin by two-dimensional centrifugation referenced to hemoglobin A1c.

    abstract::We describe an automated assay of glycohemoglobin performed with the Abbott Vision analyzer. The assay is based on batch affinity-extraction with 3-aminophenylboronic acid-derivatized agarose beads. Reagents are packaged in a disposable test pack. Whole-blood specimens are hemolyzed with saponin within a glass capilla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fiechtner M,Ramp J,England B,Knudson MA,Little RR,England JD,Goldstein DE,Wynn A

    更新日期:1992-12-01 00:00:00

  • Alternatives to radioimmunoassay: labels and methods.

    abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Schall RF Jr,Tenoso HJ

    更新日期:1981-07-01 00:00:00

  • The role of precision in determining the performance of a thyrotropin assay in diagnosing hyperthyroidism.

    abstract::We examined the relationship between analytical sensitivity, precision at the lower limit of the reference interval, and diagnostic performance in hyperthyroidism for one radioimmunoassay and five immunometric assay kits for thyrotropin. The analytical sensitivity of these kits extended from 0.05 to 1.56 milli-int. un...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilke TJ,Utley DJ

    更新日期:1988-07-01 00:00:00

  • Steroid characteristics of mineralocorticoid adrenocortical hypertension.

    abstract::Adrenocortical causes of hypertension are established by examining the mineralocorticoid hormones produced in the zona glomerulosa and zona fasciculata. In the zona glomerulosa, aldosterone excess leads to hypertension, hypokalemia, and suppressed plasma renin activity, with increased concentrations of urinary aldoste...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Biglieri EG,Kater CE

    更新日期:1991-10-01 00:00:00

  • Laboratory computing--process and information management supporting high-quality, cost-effective healthcare.

    abstract::One currently observes many healthcare institutions rushing to reengineer and install information systems with the expectation of achieving enhanced efficiency, competitiveness, and, it is hoped, higher patient satisfaction resulting from timely, high-quality care. Unfortunately, information system concepts, design, a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Buffone GJ,Moreau DR

    更新日期:1995-09-01 00:00:00

  • Thin film biosensor for rapid visual detection of nucleic acid targets.

    abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ostroff RM,Hopkins D,Haeberli AB,Baouchi W,Polisky B

    更新日期:1999-09-01 00:00:00

  • Interlaboratory proficiency survey of cholesterol and high-density lipoprotein cholesterol measurement.

    abstract::We conducted a proficiency survey of cholesterol and high-density lipoprotein (HDL) cholesterol analysis in local clinical laboratories to determine whether increased national emphasis on cholesterol measurement had resulted in changes in performance from previous surveys. Sets of frozen aliquots of plasma and HDL sup...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McMillan TA,Warnick GR

    更新日期:1988-08-01 00:00:00

  • Effect of renal function on serum nitrogen oxide concentrations.

    abstract::Nitric oxide is too short-lived to measure in vivo, but its production can be estimated by measuring its stable oxidation products, nitrites and nitrates, in serum. Renal elimination of these ions has been demonstrated, but the effect of renal function on their concentrations in serum is currently unknown. We evaluate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mackenzie IM,Ekangaki A,Young JD,Garrard CS

    更新日期:1996-03-01 00:00:00

  • Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure.

    abstract:BACKGROUND:Consideration of circulating biomarkers for risk stratification in heart failure (HF) is recommended, but the influence of atrial fibrillation (AF) on prognostic performance of many markers is unclear. We investigated the influence of AF on the prognostic performance of circulating biomarkers in HF. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa287

    authors: Tan ESJ,Chan SP,Liew OW,Chong JPC,Leong GKT,Yeo DPS,Ong HY,Jaufeerally F,Yap J,Sim D,Ng TP,Ling LH,Lam CSP,Richards AM

    更新日期:2021-01-08 00:00:00

  • Determination of serum bilirubin concentration during phototherapy of newborns and in vitro: results compared by the direct spectrometric method and the diazo method.

    abstract::During direct illumination of a serum bilirubin solution the bilirubin concentration decreased markedly, both as determined by the direct spectrometric method and (even more so) by the diazo method. In contrast, I found the same values for serum bilirubin concentrations as determined by these two methods for serum fro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ebbesen F

    更新日期:1977-01-01 00:00:00

  • Evaluation of a radioimmunoassay of urinary cortisol without extraction.

    abstract::We evaluated the Kallestad "Quanticoat" cortisol RIA for direct (no extraction) measurement of urinary free cortisol, which requires no solvent extraction. An analytical-recovery study showed a linear regression of y (measured) = 0.65x (added) + 37.5 micrograms/L (Sy.x = 21.4 micrograms/L, r = 0.978, n = 48). Recovery...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huang CM,Zweig M

    更新日期:1989-01-01 00:00:00

  • Minimal disease detection and confirmation in hematologic malignancies: combining cell sorting with clonality profiling.

    abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061259

    authors: Zehentner BK,Fritschle W,Stelzer T,Ghirardelli KM,Hunter K,Wentzel C,Bennington R,Hansen CL,Myerson D,Kalnoski M,Wells DA,Loken MR

    更新日期:2006-03-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • Radioimmunoassay of metanephrine and normetanephrine for diagnosis of pheochromocytoma.

    abstract::Sensitive and specific radioimmunoassays of metanephrine and normetanephrine were developed by use of 125I-labeled synephrine and specific metanephrine antibody, and 125I-labeled octopamine and specific normetanephrine antibody. Specific antibody for both metanephrine and normetanephrine was raised in rabbits by immun...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iinuma K,Ikeda I,Ogihara T,Hashizume K,Kurata K,Kumahara Y

    更新日期:1986-10-01 00:00:00

  • Use of leuco-dyes in the quantitative colorimetric microdetermination of hemoglobin and other heme compounds.

    abstract::Sensitivity, stability, and specificity of the color-producing reaction of hydrogen peroxide with bezidine, leuco-malachite green, or o-dianisidine were tested in numerous systems containing hemoglobin and other hemoproteins. Use of urea or low temperature (to minus 12 degrees C), or both, was highly beneficial, espec...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ahlquist DA,Schwartz S

    更新日期:1975-03-01 00:00:00

  • Two-dimensional electrophoretic patterns of proteins of normal mucosa, polyps, and carcinomas of the large intestine.

    abstract::Two-dimensional protein maps of biopsies from normal mucosa, tubular adenomas (polyps), and colonic carcinomas in humans have been studied in order to obtain information on the possible precancerous role of intestinal polyps. The maps are complex and several hundred protein spots are seen after staining with Coomassie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thorsrud AK,Vatn MH,Jellum E

    更新日期:1982-04-01 00:00:00

  • International normalized ratio for prothrombin times in patients taking oral anticoagulants: critical difference and probability of significant change in consecutive measurements.

    abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lassen JF,Brandslund I,Antonsen S

    更新日期:1995-03-01 00:00:00

  • Ten electrophoretic methods compared with a selected method for quantifying lactate dehydrogenase isoenzymes in serum.

    abstract::Using the Selected Method of McKenzie and Henderson (Selected Methods Clin Chem 1983;10:59-67) as a reference method, we compared the performance of 10 commercially available methods for determination of lactate dehydrogenase (LD, EC 1.1.1.27) isoenzymes. Results were expressed as percentage of total LD activity, as d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moses GC,Ross ML,Henderson AR

    更新日期:1988-09-01 00:00:00

  • Consensus document: Hawk's Cay meeting on therapeutic drug monitoring of cyclosporine.

    abstract::The optimal measurement method and clinical application of the therapeutic drug monitoring of cyclosporine remain uncertain. At a workshop held at Hawk's Cay, FL, from January 14 to January 17, 1990, 57 scientists presented their latest research findings, either in formal papers or as discussants. Lively debate and di...

    journal_title:Clinical chemistry

    pub_type: 共识发展会议,杂志文章,评审

    doi:

    authors: Kahan BD,Shaw LM,Holt D,Grevel J,Johnston A

    更新日期:1990-08-01 00:00:00

  • Serum alkaline phosphatase: normal values by sex and age.

    abstract::We report here the normal range of serum alkaline phophatase activity as measured by the method proposed by Hausamen et al. [Clin. Chim. Acta 15, 241 (1967)] with a much larger sample size than used in previous investigations. In the statistical analysis the sample population is subdivided by sex and age, two variable...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eastman JR,Bixler D

    更新日期:1977-09-01 00:00:00

  • Liquid-chromatographic separation of urinary 5-hydroxy-3-indoleacetic acid, with measurement at 254 nm.

    abstract::A "high-performance" liquid-chromatographic procedure for 5-hydroxy-3-indoleacetic acid is described and compared with a colorimetric method in which 1-nitroso-2-naphthol is used. The analyte and an internal standard, p-nitrobenzoic acid, were extracted into diethyl ether from urine at pH 4.0 (acidified with HCl) to w...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Draganac PS,Steindel SJ,Trawick WG

    更新日期:1980-06-01 00:00:00

  • Development of a homogeneous assay for measurement of small dense LDL cholesterol.

    abstract:BACKGROUND:Plasma concentrations of small dense (sd)-LDL are associated with the prevalence of cardiovascular events. However, the special equipment and long assay times required for sd-LDL measurement have hindered its clinical application. Herein, we report development of a simple homogeneous assay for sd-LDL-cholest...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.149559

    authors: Ito Y,Fujimura M,Ohta M,Hirano T

    更新日期:2011-01-01 00:00:00

  • Gas-chromatographic profiling of urinary acidic and alcoholic catecholamine metabolites.

    abstract::Urinary acidic and alcoholic catecholamine metabolites were isolated separately from 24-h urines by simple extraction procedures. After derivatization, extracts were analyzed by means of simultaneous gas chromatography on two different stationary phases. The quality of the assay was checked by running "normal" and enr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Muskiet FA,Fremouw-Ottevangers DC,Wolthers BG,Vries JA

    更新日期:1977-05-01 00:00:00

  • HemoCue beta-glucose photometer evaluated for use in a neonatal intensive care unit.

    abstract::We evaluated the HemoCue beta-Glucose Photometer system for use in our neonatal intensive care unit by assaying 178 heparinized whole-blood samples obtained by heel stick. The required sample size is 5 microL. Plasma glucose was analysed by a glucose oxidase/oxygen electrode methodology. Across the glucose range of 1....

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Vadasdi E,Jacobs E

    更新日期:1993-11-01 00:00:00

  • Cyclosporin whole blood immunoassays (AxSYM, CEDIA, and Emit): a critical overview of performance characteristics and comparison with HPLC.

    abstract::Assays with different specificity are used for cyclosporin monitoring in clinical transplantation. A recent survey of 35 centers showed that 86% used immunoassays for cyclosporin A (CsA). In consensus documents the following performance criteria were recommended: (a) imprecision < or = 10% at 50 microg/L and < or = 5%...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schütz E,Svinarov D,Shipkova M,Niedmann PD,Armstrong VW,Wieland E,Oellerich M

    更新日期:1998-10-01 00:00:00

  • Radioimmunoassay for detecting hepatitis B core antigen in serum from patients with chronic hepatitis B infection.

    abstract::The core antigen component of hepatitis B virus (HBV), HBcAg, may be used as a marker of viral replication. We describe a radioimmunoassay for HBcAg in serum, and compare results with those by other similar methods. Samples are centrifuged over a sucrose gradient containing 2-mercaptoethanol, and the resulting pellets...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quiroga JA,González O,Carreño V,Mora I,Porres JC,Gutiez J,Hernández-Guío C

    更新日期:1985-06-01 00:00:00

  • Kinetic measurement of total amylase and isoamylase activities with a centrifugal analyzer.

    abstract::We evaluated a new kinetic assay for alpha-amylase (Phadebas IsoAmylase Test), using modified starch as the substrate and a CentrifiChem 400 centrifugal analyzer system. We determined isoamylase activities by using a selective inhibitor. Results were compared with those obtained with the chromogenic Phadebas dyed-star...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de Rijke D,Kreutzer HJ

    更新日期:1983-06-01 00:00:00