Evaluation of a radioimmunoassay of urinary cortisol without extraction.

Abstract:

:We evaluated the Kallestad "Quanticoat" cortisol RIA for direct (no extraction) measurement of urinary free cortisol, which requires no solvent extraction. An analytical-recovery study showed a linear regression of y (measured) = 0.65x (added) + 37.5 micrograms/L (Sy.x = 21.4 micrograms/L, r = 0.978, n = 48). Recovery appeared to vary with the urine used and with the concentrations of cortisol added. Within- and between-run CVs were less than or equal to 4.1% and less than or equal to 3.8%, respectively. Cross reactivities were low, except for prednisolone (20.5%). This no-extraction method gave higher values for urinary free cortisol than did either an RIA method involving extraction or an HPLC method. A comparison study with the HPLC (x) and with the method involving extraction (x') gave the following Deming-debiased regression equations: y = 1.60x + 68.8 (Sy.x = 34.4, n = 29) and y = 1.33x' + 0.69 (Sy.x = 40.3, n = 66), respectively. We conclude that the no-extraction method may give misleading results for patients' diagnosis or management if this cross reactivity is not taken into account.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Huang CM,Zweig M

subject

Has Abstract

pub_date

1989-01-01 00:00:00

pages

125-6

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

35

pub_type

杂志文章
  • Blood loss from laboratory tests.

    abstract:BACKGROUND:Laboratory tests can be an important source of blood loss in hospitals, especially for newborns and patients in intensive care. The aim of this study was to quantify blood loss for laboratory diagnostic tests in a large number of patients in a teaching hospital. METHODS:We estimated blood loss by multiplyin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.10.1651

    authors: Wisser D,van Ackern K,Knoll E,Wisser H,Bertsch T

    更新日期:2003-10-01 00:00:00

  • Radioimmunoassay of creatine kinase isoenzymes in human serum: isoenzyme MM.

    abstract::Measurement of the mass concentration of serum enzymes by radioimmunoassay provides direct quantitation of specific isoenzymes and may be less subject to some of the limitations of traditional assay procedures for enzymes. We describe the development of a sensitive and specific radioimmunoassay for the muscle isoenzym...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Steirteghem AC,Zweig MH,Schechter AN

    更新日期:1978-03-01 00:00:00

  • Sensitive, direct colorimetric assay for copper in serum.

    abstract::We have developed a sensitive procedure for determination of serum copper by use of the color reagent 4-(3,5-dibromo-2-pyridylazo)-N-ethyl-N-sulfopropylaniline. After mixing serum sample and reagent, and incubating at 37 degrees C for 5 min, we measure the absorbance of the resulting chelate complex at 580 nm (molar a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Abe A,Yamashita S,Noma A

    更新日期:1989-04-01 00:00:00

  • Separation of bound and free ligand by ethacridine (Rivanol) in thyroxin radioimmunoassay.

    abstract::In this simple and low-cost radioimmunoassay (RIA) procedure for thyroxin (T4), ethacridine (6,9-diamino-2-ethoxyacridine lactate; Rivanol) is used to separate antibody-bound ligand and free ligand. This acridine dye precipitates free T4 not bound to antibody. At pH 8.6, it precipitates more than 90% of 125I-labeled T...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bhupal V,Mani RS

    更新日期:1983-11-01 00:00:00

  • Gas-chromatographic determination of mephenytoin and desmethylmephenytoin, after off-column alkylation.

    abstract::We describe a gas-liquid chromatographic method for determining mephenytoin and its active metabolite, desmethylmephenytoin, in human serum. 5-Methyl-5-phenylhydantoin is used as the internal standard. The method involves extraction of the drugs by adsorption onto charcoal and off-column derivatization to their pentyl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raisys VA,Zebelman AM,MacMillan SF

    更新日期:1979-01-01 00:00:00

  • Rapid capillary zone electrophoresis in isoelectric histidine buffer: high resolution of the poly-T tract allelic variants in intron 8 of the CFTR gene.

    abstract::The poly-T tract in intron 8 of the cystic fibrosis conductance transmembrane regulator (CFTR) gene exists in three variants, 5T, 7T, and 9T. The 7T and 9T variants generate a predominantly normal transcript, whereas the 5T variant engenders an anomalous product. The analysis of the poly-T tract is assuming increasing...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gelfi C,Perego M,Righetti PG,Cainarca S,Firpo S,Ferrari M,Cremonesi L

    更新日期:1998-05-01 00:00:00

  • Cholesterol screening: comparative evaluation of on-site and laboratory-based measurements.

    abstract::We measured cholesterol in capillary blood samples from 9683 volunteers over a four-day on-site community screening program, using the "Reflotron" desk-top analyzer (Boehringer-Mannheim Diagnostics, Indianapolis, IN). We also measured cholesterol in venous blood samples from 3% of those screened (a) with the Reflotron...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bachorik PS,Rock R,Cloey T,Treciak E,Becker D,Sigmund W

    更新日期:1990-02-01 00:00:00

  • Anaphylaxis in the mouse--a model for using two-dimensional electroimmunodiffusion to study pathological changes in multiple serum proteins simultaneously.

    abstract::Two-dimensional electroimmunodiffusion is rarely used in clinical chemistry, because its potentialities are not yet widely appreciated. Studying mouse anaphylaxis, we observed with this technique certain striking short- and long-term pathologic changes in several important serum antigens, which aptly demonstrate its u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quintero S,Crowle AJ

    更新日期:1979-05-01 00:00:00

  • Comparison of quality-control rules used in clinical chemistry laboratories.

    abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bishop J,Nix AB

    更新日期:1993-08-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Relationship between cortisol increment and basal cortisol: implications for the low-dose short adrenocorticotropic hormone stimulation test.

    abstract:BACKGROUND:We analyzed the low-dose (1 microg) rapid adrenocorticotropic hormone test (LDST) in 17 patients with a normal hypothalamic-pituitary-adrenal axis to determine reference intervals for the LDST on the basis of poststimulation cortisol increments. METHODS:We analyzed test results for 17 patients (14 females a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061267

    authors: Doi SA,Lasheen I,Al-Humood K,Al-Shoumer KA

    更新日期:2006-04-01 00:00:00

  • Production and certification of an enzyme reference material for gamma-glutamyltransferase (CRM 319). Part 2: Certification campaign.

    abstract::We describe the process of certification for a gamma-glutamyltransferase reference material (CRM no. 319). Fifteen laboratories participated to this interlaboratory evaluation. All steps of the measurements were controlled in an effort to locate potential sources of variations. In particular, the exclusion of some dat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schiele F,Muller J,Colinet E,Siest G

    更新日期:1987-11-01 00:00:00

  • Clinical Correlations of Programmed Cell Death Ligand 1 Status in Liquid and Standard Biopsies in Breast Cancer.

    abstract:BACKGROUND:Data regarding the prognostic value of programmed cell death ligand 1 (PD-L1) expression on circulating tumor cells (CTCs) are lacking. However, CTCs could represent an alternative approach to serial biopsies, allowing real-time monitoring of cancer phenotype. METHODS:We evaluated, in a dedicated prospectiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa121

    authors: Jacot W,Mazel M,Mollevi C,Pouderoux S,D'Hondt V,Cayrefourcq L,Bourgier C,Boissiere-Michot F,Berrabah F,Lopez-Crapez E,Bidard FC,Viala M,Maudelonde T,Guiu S,Alix-Panabières C

    更新日期:2020-08-01 00:00:00

  • Validation and application of a liquid-chromatographic/enzymatic assay for individual bile acids in the serum of rats.

    abstract::A liquid-chromatographic technique with a post-column enzymatic reaction and fluorescence detection was validated for analysis of individual bile acids in the serum of rats. Extraction recoveries averaged 91.1% (SD 6.9%) for all bile acids. The assay was sensitive (minimum detection of 16.8 pmol per 100-microL injecti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson MB,Blair PC,Morris RW,Neptun DA,Deyo DF,Popp JA

    更新日期:1987-10-01 00:00:00

  • P-selectin- and CD63-exposing platelet microparticles reflect platelet activation in peripheral arterial disease and myocardial infarction.

    abstract:BACKGROUND:Platelet-derived microparticles (PMPs) are generally considered a marker of platelet activation in cardiovascular disease. We studied the extent to which PMP subpopulations parallel platelet activation in vitro and in vivo. METHODS:Using flow cytometry, we analyzed PMP subpopulations from resting and activa...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.057414

    authors: van der Zee PM,Biró E,Ko Y,de Winter RJ,Hack CE,Sturk A,Nieuwland R

    更新日期:2006-04-01 00:00:00

  • Serum erythropoietin concentrations and iron status in patients on chronic hemodialysis.

    abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Seguchi C,Shima T,Misaki M,Takarada Y,Okazaki T

    更新日期:1992-02-01 00:00:00

  • Medicare's demonstration of competitive bidding for clinical laboratory services: what it means for clinical laboratories.

    abstract::The purpose of Medicare's Demonstration of Competitive Bidding for Clinical Laboratory Services is to determine whether competitive bidding can be used to provide quality laboratory services at prices below current Medicare reimbursement rates. Here, we present key features of the preliminary design for the demonstrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hoerger TJ,Lindrooth RC,Eggleston JL

    更新日期:1998-08-01 00:00:00

  • Liquid Chromatography-Tandem Mass Spectrometry Assay of Leukocyte Acid α-Glucosidase for Post-Newborn Screening Evaluation of Pompe Disease.

    abstract:BACKGROUND:Pompe disease (PD) is the first lysosomal storage disorder to be added to the Recommended Uniform Screening Panel for newborn screening. This condition has a broad phenotypic spectrum, ranging from an infantile form (IOPD), with severe morbidity and mortality in infancy, to a late-onset form (LOPD) with vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.259036

    authors: Lin N,Huang J,Violante S,Orsini JJ,Caggana M,Hughes EE,Stevens C,DiAntonio L,Chieh Liao H,Hong X,Ghomashchi F,Babu Kumar A,Zhou H,Kornreich R,Wasserstein M,Gelb MH,Yu C

    更新日期:2017-04-01 00:00:00

  • Determination of beta 2-microglobulin in human urine and serum by latex immunoassay.

    abstract::This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bernard AM,Vyskocil A,Lauwerys RR

    更新日期:1981-06-01 00:00:00

  • Detection of biological threat agents by real-time PCR: comparison of assay performance on the R.A.P.I.D., the LightCycler, and the Smart Cycler platforms.

    abstract:BACKGROUND:Rapid detection of biological threat agents is critical for timely therapeutic administration. Fluorogenic PCR provides a rapid, sensitive, and specific tool for molecular identification of these agents. We compared the performance of assays for 7 biological threat agents on the Idaho Technology, Inc. R.A.P....

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052522

    authors: Christensen DR,Hartman LJ,Loveless BM,Frye MS,Shipley MA,Bridge DL,Richards MJ,Kaplan RS,Garrison J,Baldwin CD,Kulesh DA,Norwood DA

    更新日期:2006-01-01 00:00:00

  • Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    abstract::Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shepherd J,Packard CJ,Dryburgh FJ,Third JL

    更新日期:1975-12-01 00:00:00

  • Three commercial polyclonal immunoassays for cyclosporine in whole blood compared: 1. Results with patients' specimens.

    abstract::We assessed the performance of three commercially available polyclonal immunoassays for apparent cyclosporine in 120 whole-blood specimens collected from transplant recipients just before their next dose of cyclosporine (CsA). The assays were (a) Abbott's TDx fluorescent polarization immunoassay for CsA and its metabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Strassman MJ,Lensmeyer GL,Wiebe DA,Carlson IH

    更新日期:1990-01-01 00:00:00

  • Lipoprotein lipids in women with androgen excess: independent associations with increased insulin and androgen.

    abstract::Concentrations of triglycerides are increased and concentrations of high-density lipoprotein (HDL) cholesterol are low in women with hyperandrogenism. These alterations could be related to excessive androgen or estrogen, to hyperinsulinism, or to a combination of these abnormalities. We examined their independent infl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wild RA,Applebaum-Bowden D,Demers LM,Bartholomew M,Landis JR,Hazzard WR,Santen RJ

    更新日期:1990-02-01 00:00:00

  • Measurement of thyroglobulin by liquid chromatography-tandem mass spectrometry in serum and plasma in the presence of antithyroglobulin autoantibodies.

    abstract:BACKGROUND:Measurement of serum thyroglobulin (Tg) is used to monitor patients after treatment for differentiated thyroid carcinoma (TC). Difficulty in using Tg as a biomarker of the recurrence of TC in many patients stems from the presence of endogenous anti-Tg autoantibodies (Tg-AAbs), which can interfere with immuno...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.195594

    authors: Kushnir MM,Rockwood AL,Roberts WL,Abraham D,Hoofnagle AN,Meikle AW

    更新日期:2013-06-01 00:00:00

  • Gas-chromatographic assay of free phenytoin in ultrafiltrates of plasma: test of a new filtration apparatus and specimen stability.

    abstract::I describe a gas-chromatographic procedure involving a nitrogen detector for "free" (or "unbound") phenytoin in the concentration range 0.2-4.0 mg/L in ultrafiltrates of plasma. The CV (n = 10) for the assay was 2.9% for a 0.49 mg/L concentration, 1.5% for 2.02 mg/L. The sensitivity was 0.05 mg/L. The ultrafiltration ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Joern WA

    更新日期:1981-03-01 00:00:00

  • Microtiter format for simultaneous multianalyte detection and development of a PCR-chemiluminescent enzyme immunoassay for typing human papillomavirus DNAs.

    abstract:BACKGROUND:To allow multianalyte binding assays, we have developed a novel polystyrene microtiter plate containing 24 main wells, each divided into 7 subwells. We explored its clinical potential by developing a PCR-chemiluminescent immunoassay (PCR-CLEIA) for simultaneous detection and typing of seven high oncogenic ri...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Roda A,Mirasoli M,Venturoli S,Cricca M,Bonvicini F,Baraldini M,Pasini P,Zerbini M,Musiani M

    更新日期:2002-10-01 00:00:00

  • Use of values for calcium and protein in serum, and of a derived index obtained from a probability population sample.

    abstract::We measured serum protein and calcium concentrations in 2340 individuals between 10 and 96 years of age from 900 families chosen by probability methods to give a representative population. These values were used to calculate an index, based on a regression analysis of serum protein on calcium, which was then treated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kelly A,Munan L,PetitClerc C,Ho KP,Billon B

    更新日期:1976-10-01 00:00:00

  • Electrophoretic patterns for serum glycoproteins reflect the presence of human breast cancer.

    abstract::We describe a group of glycoproteins that are synthesized and released by human breast tumors maintained in organ culture and similar glycoproteins released by a human breast carcinoma cell line (BT-20). The electrophoretic mobility of these glycoproteins on cellulose acetate is consistent with increased glycoprotein-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Tökes ZA

    更新日期:1977-11-01 00:00:00

  • Serum creatine kinase isoenzyme BB is a poor index to the size of various brain lesions.

    abstract::We divided patients with brain lesions into three groups: (a) patients with primary or metastatic brain cancer, (b) brain infarctions, and (c) brain contusion(s). We analyzed each patient's sera for creatine kinase isoenzyme BB (CK-BB), using a monoclonal antibody kit (Impres-BB; International Immunoassay Laboratories...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz JG,Bazan C 3rd,Gage CL,Prihoda TJ,Gillham SL

    更新日期:1989-04-01 00:00:00

  • Evidence that the amino-terminal composition of non-(1-84) parathyroid hormone fragments starts before position 19.

    abstract:BACKGROUND:Non-(1-84) parathyroid hormone (PTH) fragments are large C-terminal fragments of PTH with a partially preserved N-terminal structure. They differ from other C-terminal PTH fragments, which do not have an N-terminal structure and do not react in intact PTH assays. We aimed to identify the minimal N-terminal s...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.040485

    authors: D'Amour P,Brossard JH,Räkel A,Rousseau L,Albert C,Cantor T

    更新日期:2005-01-01 00:00:00