Determination of beta 2-microglobulin in human urine and serum by latex immunoassay.

Abstract:

:This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidimetry. A novel aspect of this method is the capability to prevent nonspecific agglutination of the antibody-coated particles by diluting them with an albumin solution of well-defined characteristics (pH, freshness, concentration) just before the assay. The assayable concentration range is 1--32 micrograms/L, the detection limit 0.5 micrograms/L. Within-assay CV, based on 10 determinations of beta 2-m in urine and serum at two different dilutions, ranged from 4.6 to 8.7%. Between-assay CV, calculated from 10 determinations of beta 2-m in urine and serum, was 10 and 8.4%, respectively. Analytical recovery of beta 2-m in urine averaged 97% and in serum 104% (n = 10). No component of urine or serum interfered. Coefficients of correlation for beta 2-m in urine or serum as measured by radioimmunoassay and latex immunoassay were 0.97 and 0.93, respectively. Concentrations of beta 2-m in serum and urine from 33 healthy men (ages 20 to 67 years) averaged 1.5 mg/l and 54 micrograms/g of creatine, respectively.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Bernard AM,Vyskocil A,Lauwerys RR

subject

Has Abstract

pub_date

1981-06-01 00:00:00

pages

832-7

issue

6

eissn

0009-9147

issn

1530-8561

journal_volume

27

pub_type

杂志文章
  • Use and abuse of imprecision profiles: some pitfalls illustrated by computing and plotting confidence intervals.

    abstract::Published estimates of the imprecision characteristics of immunoassays are often based on quantities of data that seem to be inadequate. The increasing use of imprecision profiles has not necessarily improved the situation. We describe and illustrate a method of computing 95% confidence intervals for profiles estimate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sadler WA,Smith MH

    更新日期:1990-07-01 00:00:00

  • Novel technique for scanning of codon 634 of the RET protooncogene with fluorescence resonance energy transfer and real-time PCR in patients with medullary thyroid carcinoma.

    abstract:BACKGROUND:The multiple endocrine neoplasia 2 (MEN 2) syndromes [MEN 2A, MEN 2B, and familial medullary thyroid carcinoma (FMTC)] are caused by germline mutations of the RET protooncogene. Because 85% of MEN 2A patients and 30% of FMTC patients have mutations at codon 634, the recommended molecular analyses begin at ex...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ruiz A,Antiñolo G,Marcos I,Borrego S

    更新日期:2001-11-01 00:00:00

  • Monomeric calgranulins measured by SELDI-TOF mass spectrometry and calprotectin measured by ELISA as biomarkers in arthritis.

    abstract:BACKGROUND:SELDI-TOF mass spectrometry (MS) is a high-throughput proteomic approach with potential for identifying novel forms of serum biomarkers of arthritis. METHODS:We used SELDI-TOF MS to analyze serum samples from patients with various forms of inflammatory arthritis. Several protein profiles were collected on d...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.099549

    authors: de Seny D,Fillet M,Ribbens C,Marée R,Meuwis MA,Lutteri L,Chapelle JP,Wehenkel L,Louis E,Merville MP,Malaise M

    更新日期:2008-06-01 00:00:00

  • Evaluation of the Beckman creatinine analyzer.

    abstract::We compared results obtained with the Beckman Creatinine Analyzer (Beckman Instruments, Inc.) to those with the GEMSAEC Centrifugal Analyzer (Electro-Nucleonics, Inc.) and with a manual method for determination of creatinine in serum and urine. Linearity, stability, recovery, and precision were evaluated. Interference...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hicks JM,Iosefsohn M,Lewis SA

    更新日期:1979-06-01 00:00:00

  • Serum erythropoietin concentrations and iron status in patients on chronic hemodialysis.

    abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Seguchi C,Shima T,Misaki M,Takarada Y,Okazaki T

    更新日期:1992-02-01 00:00:00

  • A 125I-radioimmunoassay for measuring androstenedione in serum and in blood-spot samples from neonates.

    abstract::We developed a radioimmunoassay with a gamma-emitting radioligand to measure androstenedione in human serum and in dried blood-spot samples from newborns. Antisera were raised in rabbits against androstenedione linked to bovine serum albumin at positions 3, 6, or 11 on the steroid nucleus. Radioligands were prepared b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thomson S,Wallace AM,Cook B

    更新日期:1989-08-01 00:00:00

  • Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots.

    abstract::We have assessed the technical performance and robustness of NycoCard CRP Whole Blood, a near-patient test for C-reactive protein (CRP), when used in realistic daily routine situations in general practice clinics (GPC). Thirteen GPCs participated, five of them with technician staff. From 898 patients, split-sample mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dahler-Eriksen BS,Lassen JF,Petersen PH,Lund ED,Lauritzen T,Brandslund I

    更新日期:1997-11-01 00:00:00

  • Bias in sensitivity and specificity caused by data-driven selection of optimal cutoff values: mechanisms, magnitude, and solutions.

    abstract:BACKGROUND:Optimal cutoff values for tests results involving continuous variables are often derived in a data-driven way. This approach, however, may lead to overly optimistic measures of diagnostic accuracy. We evaluated the magnitude of the bias in sensitivity and specificity associated with data-driven selection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.096032

    authors: Leeflang MM,Moons KG,Reitsma JB,Zwinderman AH

    更新日期:2008-04-01 00:00:00

  • Rapid Zeeman atomic absorption determination of copper in serum and urine.

    abstract::In this simple, quick procedure for determining copper in human serum and urine, the serum and urine specimens were analyzed directly after dilution with a solution of HNO3 and Triton X-100, 1 mL/L each. We calibrated with aqueous standards for quantitation in Zeeman background atomic absorption spectrometry. By modif...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wang ST,Demshar HP

    更新日期:1993-09-01 00:00:00

  • Improved liquid chromatographic/immunoassay of digoxin in serum.

    abstract::This HPLC/immunoassay procedure measures digoxin in serum with no interference from digoxin metabolites or digoxin-like factors. We used solid-phase (C18 and Diol) extraction, a C18 column with a tetrahydrofuran/water mobile phase, and final quantification by fluorescence polarization immunoassay. Deslanoside and gito...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stone JA,Soldin SJ

    更新日期:1988-12-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • Angiotensin-converting enzyme determination in plasma during therapy with converting enzyme inhibitor: two methods compared.

    abstract::For normal and above-normal concentrations of angiotensin-converting enzyme (ACE; EC 3.4.15.1) activity in plasma, results of a manual fluorometric method [with hippuryl-histidyl-leucine (HHL), 5 mmol/L, as substrate] correlated well with those of an automated spectrophotometric method [with 3-(2-furylacryloyl)-L-phen...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gorski TP,Campbell DJ

    更新日期:1991-08-01 00:00:00

  • Immunological assays of apolipoproteins in plasma: methods and instrumentation.

    abstract::A number of immunological techniques--radioimmunoassay, enzyme-linked immunosorbent assay (ELISA), electroimmunoassay, radial immunodiffusion, and a variety of immunoprecipitin assays--have been used to quantify apolipoproteins in plasma. This paper outlines their technical details and discusses their major advantages...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Labeur C,Shepherd J,Rosseneu M

    更新日期:1990-04-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Improved 63Ni radiochemical assay of free fatty acids in plasma.

    abstract::We have modified the 63Ni radiochemical method of Ho (Anal Biochem 1970;36:105) for determination of free fatty acids (FFA) in plasma. Extracting 1 or 0.1 mL of plasma with Dole's mixture (J Biol Chem 1960;235:2595) and washing the "heptane" layer with two volumes of isopropanol/water/dilute (0.5 mol/L) H2SO4 (25/25/1...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Barash H,Akov S

    更新日期:1987-01-01 00:00:00

  • Comparability of results by simplified methods for measuring serum lipoprotein cholesterol in a pediatric population.

    abstract::We compared serum lipoprotein cholesterol concentrations in a randomly selected subsample (n = 406) population of children (ages 5 to 17 years), as measured by the heparin-Ca2+ and the heparin-Mn2+ precipitation methods. Statistical analysis showed significant differences between results by these methods, especially i...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Srinivasan SR,Foster TA,Berenson GS

    更新日期:1980-10-01 00:00:00

  • Applications of MALDI Mass Spectrometry in Clinical Chemistry.

    abstract:BACKGROUND:MALDI-TOF mass spectrometry (MS) is set to make inroads into clinical chemistry because it offers advantages over other analytical platforms. These advantages include low acquisition and operating costs, ease of use, ruggedness, and high throughput. When coupled with innovative front-end strategies and appli...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239491

    authors: Duncan MW,Nedelkov D,Walsh R,Hattan SJ

    更新日期:2016-01-01 00:00:00

  • Electrophoretic patterns for serum glycoproteins reflect the presence of human breast cancer.

    abstract::We describe a group of glycoproteins that are synthesized and released by human breast tumors maintained in organ culture and similar glycoproteins released by a human breast carcinoma cell line (BT-20). The electrophoretic mobility of these glycoproteins on cellulose acetate is consistent with increased glycoprotein-...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Silverman LM,Dermer GB,Tökes ZA

    更新日期:1977-11-01 00:00:00

  • Urinary protein as measured with a pyrogallol red-molybdate complex, manually and in a Hitachi 726 automated analyzer.

    abstract::In this new method for determining urinary protein, the reaction is complete within 10 min at 37 degrees C. This method is applicable to automated as well as manual measurements. Protein concentration and absorbance at 600 nm are linearly related throughout a wide range of concentrations, 10 to 16 000 mg/L. However, t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Watanabe N,Kamei S,Ohkubo A,Yamanaka M,Ohsawa S,Makino K,Tokuda K

    更新日期:1986-08-01 00:00:00

  • Improved agarose electrophoretic method for separating alkaline phosphatase isoenzymes in serum.

    abstract::A modified agarose electrophoretic system for the separation of alkaline phosphatase (ALP, EC 3.1.3.1) isoenzymes is described. Bone, liver, high-molecular-mass, and intestinal ALP are separated with high reproducibility. The sensitivity of the agarose system is superior to cellulose acetate in detecting high-Mr ALP. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Hoof VO,Lepoutre LG,Hoylaerts MF,Chevigné R,De Broe ME

    更新日期:1988-09-01 00:00:00

  • Gene amplification for c-erbB-2, c-myc, epidermal growth factor receptor, int-2, and N-myc measured by quantitative PCR with a multiple competitor template.

    abstract::We recently proposed a quantitative PCR procedure for the absolute measurement of c-erbB-2 oncogene amplification, based on the simultaneous polymerase chain reaction (PCR) amplification of the target gene and of a competitor DNA molecule acting as internal standard. To increase the number of assayable oncogenes and t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sestini R,Orlando C,Zentilin L,Lami D,Gelmini S,Pinzani P,Giacca M,Pazzagli M

    更新日期:1995-06-01 00:00:00

  • RNA extraction from archival formalin-fixed paraffin-embedded tissue: a comparison of manual, semiautomated, and fully automated purification methods.

    abstract:BACKGROUND:Formalin-fixed paraffin-embedded (FFPE) tumor material represents a valuable resource for the analysis of RNA-based biomarkers, both in research laboratories and in routine clinical testing. A robust and automated RNA-extraction method with a high sample throughput is required. METHODS:We evaluated extracti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.122572

    authors: Bohmann K,Hennig G,Rogel U,Poremba C,Mueller BM,Fritz P,Stoerkel S,Schaefer KL

    更新日期:2009-09-01 00:00:00

  • Detection of alpha 1-antitrypsin Z and S mutations by polymerase chain reaction-mediated site-directed mutagenesis.

    abstract::alpha 1-Antitrypsin (A1AT) deficiency is a relatively common autosomal recessive disease, resulting most often from a single base pair (1 bp) substitution called the Z mutation. Previous genetic tests for carriers and affected patients have relied on quantitative binding of radioactive probes to an amplified gene prod...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tazelaar JP,Friedman KJ,Kline RS,Guthrie ML,Farber RA

    更新日期:1992-08-01 00:00:00

  • A more sensitive automated method for determination of ornithine carbamoyltransferase activity in human serum.

    abstract::Ornithine carbamoyltransferase (EC 2.1.3.3) activity is a sensitive, specific indicator of hepatocellular injury. This paper describes development of an improved automated procedure for measurement of this activity. Triethanolamine-ethylenediaminetetraacetate is used as a buffer, and activity is determined by measurin...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Clayson KJ,Fine JS,Strandjord PE

    更新日期:1975-05-01 00:00:00

  • Two-dimensional gel electrophoresis of serum specimens from patients with monoclonal gammopathies.

    abstract::We modified the ISO-DALT two-dimensional gel electrophoresis system to allow the routine examination of serum specimens from patients with monoclonal gammopathies. This system, MC-Iso 1, is characterized by a broad pH gradient for resolving the basic immunoglobulin heavy and light chains. The increased resolution of b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tracy RP,Currie RM,Kyle RA,Young DS

    更新日期:1982-04-01 00:00:00

  • Cardiac troponin I associated with the development of unrecognized myocardial infarctions detected with MRI.

    abstract:BACKGROUND:Late enhancement MRI (LE-MRI) and cardiac troponin I (cTnI) are sensitive methods to detect subclinical myocardial injury. We sought to investigate the relation between plasma concentrations of cTnI measured with a high-sensitivity assay (hs-cTnI) and the development of unrecognized myocardial infarctions (U...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2014.222430

    authors: Barbier CE,Themudo R,Bjerner T,Johansson L,Lindahl B,Venge P,Lind L,Ahlström H

    更新日期:2014-10-01 00:00:00

  • Micromethod for lead determination in whole blood by atomic absorption, with use of the graphite furnace.

    abstract::I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fernandez FJ

    更新日期:1975-04-01 00:00:00

  • Immunoradiometric serum ferritin concentration compared with stainable bone-marrow iron as indices to iron stores.

    abstract::Immunoradiometric analysis has made it possible to measure ferritin reliably in serum. The determination is a sensitive means of assessing body iron because concentrations of ferritin closely parallel the body's reticuloendothelial iron stores. The information provided is similar to that obtained from bone-marrow aspi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Forman DT,Vye MV

    更新日期:1980-01-01 00:00:00

  • Clinical and laboratory studies of a new immunoradiometric assay of parathyroid hormone-related protein.

    abstract::Parathyroid hormone-related protein (PTHrP) was measured in plasma by a new immunoradiometric assay (IRMA) from Nichols Institute. The assay is specific for PTHrP and shows excellent parallelism when measuring keratinocyte fluid, samples with high PTHrP content, and PTHrP-supplemented plasma. A precision profile estab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fraser WD,Robinson J,Lawton R,Durham B,Gallacher SJ,Boyle IT,Beastall GH,Logue FC

    更新日期:1993-03-01 00:00:00

  • Cost-effective assays for use in monitoring carbamazepine, phenobarbital, and phenytoin in serum.

    abstract::Using Syva "EMIT" reagents and the Cobas Bio centrifugal analyzer, we have developed cost-effective assays for therapeutic drug monitoring of carbamazepine, phenobarbital, and phenytoin. With these optimized methods one can assay up to 2470 samples with a single 100-test EMIT kit with good precision and accuracy. Betw...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Moore FM,Simpson D

    更新日期:1989-08-01 00:00:00