Micromethod for lead determination in whole blood by atomic absorption, with use of the graphite furnace.

Abstract:

:I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the blood matrix, simultaneous background correction is used. Interlaboratory comparison with a flame atomic absorption technique that requires extraction yielded high correlation (r equal to 0.98). Within-run precision (coefficient of variation) ranged from 2 to 4 percent. Lead in blood can be accurately measured in as little as 20 mul of blood, hence the method is suitable for routine laboratory use and for pediatric screening.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Fernandez FJ

subject

Has Abstract

pub_date

1975-04-01 00:00:00

pages

558-61

issue

4

eissn

0009-9147

issn

1530-8561

journal_volume

21

pub_type

杂志文章
  • Vitamin C and glycohemoglobin.

    abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Weykamp CW,Penders TJ,Baadenhuijsen H,Muskiet FA,Martina W,van der Slik W

    更新日期:1995-05-01 00:00:00

  • Development and evaluation of quality control dried blood spot materials in newborn screening for lysosomal storage disorders.

    abstract:BACKGROUND:Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.111864

    authors: De Jesus VR,Zhang XK,Keutzer J,Bodamer OA,Mühl A,Orsini JJ,Caggana M,Vogt RF,Hannon WH

    更新日期:2009-01-01 00:00:00

  • Use and abuse of imprecision profiles: some pitfalls illustrated by computing and plotting confidence intervals.

    abstract::Published estimates of the imprecision characteristics of immunoassays are often based on quantities of data that seem to be inadequate. The increasing use of imprecision profiles has not necessarily improved the situation. We describe and illustrate a method of computing 95% confidence intervals for profiles estimate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sadler WA,Smith MH

    更新日期:1990-07-01 00:00:00

  • Use of a cholesterol-rich bovine lipoprotein to enhance cholesterol concentrations in the preparation of serum control materials.

    abstract::We describe a process for preparing a cholesterol-rich lipoprotein extract from bovine serum. The material is used to enhance cholestrol concentration up to 3.5 g/liter in a clear control material from human serum. The optical clarity of the enriched serum is only slightly affected by lyophilization and reconstitution...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Proksch GJ,Bonderman DP

    更新日期:1976-08-01 00:00:00

  • Determination of beta 2-microglobulin in human urine and serum by latex immunoassay.

    abstract::This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bernard AM,Vyskocil A,Lauwerys RR

    更新日期:1981-06-01 00:00:00

  • Use of precision profiles to evaluate precision of the automated leukocyte differential.

    abstract::The commonly used methods of assessing the precision of the automated leukocyte differential have certain drawbacks that affect the validity and comparability of results. In the present report, we introduce a procedure based on building precision profiles from a large number of within-run imprecision experiments. The ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hübl W,Tlustos L,Bayer PM

    更新日期:1996-07-01 00:00:00

  • Dried plasma spot measurements of ferritin and transferrin receptor for assessing iron status.

    abstract:BACKGROUND:Efforts to reduce the high global prevalence of nutritional anemia require the use of both reliable laboratory assays to distinguish iron deficiency from other causes of anemia and cost-effective methods for collection of blood specimens under field conditions. The suitability of using small plasma samples s...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Flowers CH,Cook JD

    更新日期:1999-10-01 00:00:00

  • Evaluation of pteroylglutamic acid and n-5-methyltetrahydrofolic acid reference standards in a new "No-Boil" radioassay for serum folate.

    abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Theobald RA,Batchelder M,Sturgeon MF

    更新日期:1981-04-01 00:00:00

  • Ultrafiltration discrepancies in recovery of myoglobin from urine.

    abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Loun B,Copeland KR,Sedor FA

    更新日期:1996-06-01 00:00:00

  • Hyperhomocysteinemia and myocardial expression of brain natriuretic peptide in rats.

    abstract:BACKGROUND:Hyperhomocysteinemia (HHcy) has been linked to impaired left ventricular function and clinical class in patients with chronic heart failure. We hypothesized that HHcy stimulates myocardial brain natriuretic peptide (BNP) expression and induces adverse left ventricular remodeling. METHODS:We randomized 50 ra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077859

    authors: Herrmann M,Taban-Shoma O,Hübner U,Pexa A,Kilter H,Umanskaya N,Straub RH,Böhm M,Herrmann W

    更新日期:2007-04-01 00:00:00

  • Application of Cardiac Troponin in Cardiovascular Diseases Other Than Acute Coronary Syndrome.

    abstract:BACKGROUND:Increased cardiac troponin concentrations in acute coronary syndrome (ACS) identify patients with ongoing cardiomyocyte necrosis who are at increased risk. However, with the use of more precise assays, cardiac troponin increases are commonly noted in other cardiovascular conditions as well. This has generate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2016.261495

    authors: Eggers KM,Lindahl B

    更新日期:2017-01-01 00:00:00

  • Gas-chromatographic analysis for chlorpromazine and some of its metabolites in human serum, with use of a nitrogen detector.

    abstract::We describe a gas-chromatographic method for measuring chlorpromazine and its metabolites chlorpromazine sulfoxide, mono-N-desmethylchlorpromazine, and di-N-desmethylchlorpromazine at therapeutic concentrations in human serum, with use of a nitrogen detector. The compounds are extracted from serum at pH 10.5 into hexa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bailey DN,Guba JJ

    更新日期:1979-07-01 00:00:00

  • Multimarker quantitative real-time PCR detection of circulating melanoma cells in peripheral blood: relation to disease stage in melanoma patients.

    abstract:BACKGROUND:Detection of melanoma cells in circulation may be important in assessing tumor progression. The objective of this study was to develop a specific, reliable multimarker quantitative real-time reverse transcription-PCR (qRT) assay for detecting melanoma cells in patients' blood. METHODS:We developed qRT assay...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.045096

    authors: Koyanagi K,Kuo C,Nakagawa T,Mori T,Ueno H,Lorico AR Jr,Wang HJ,Hseuh E,O'Day SJ,Hoon DS

    更新日期:2005-06-01 00:00:00

  • Use of medians and "average of normals" of patients' data for assessment of long-term analytical stability.

    abstract::Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lott JA,Smith DA,Mitchell LC,Moeschberger ML

    更新日期:1996-06-01 00:00:00

  • Fluorometric assay for N-acetylprocainamide.

    abstract::We describe a simple, rapid fluorometric assay for separate quantitative analysis of procainamide and N-acetylprocainamide in mixtures. The effective lenear range (fluorescence vs. concentration) in serum is 0.1 to 10.0 mg/liter, regardless of the ratio (by weight) of the two drugs from 1:10 to 10:1. Analytical recove...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Matusik E,Gibson TP

    更新日期:1975-12-01 00:00:00

  • Detection of hemoglobin-based oxygen carriers in human serum for doping analysis: confirmation by size-exclusion HPLC.

    abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.026591

    authors: Varlet-Marie E,Ashenden M,Lasne F,Sicart MT,Marion B,de Ceaurriz J,Audran M

    更新日期:2004-04-01 00:00:00

  • The fiscal consequences of central vs distributed testing of glucose.

    abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Winkelman JW,Wybenga DR,Tanasijevic MJ

    更新日期:1994-08-01 00:00:00

  • Liquid-phase reactions started by rehydrating lyophilized reagents in a centrifugal analyzer.

    abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Truchaud A,Glikmanas G,Gourmelin Y,Hersant J,Trepo D,Foray G,Collombel C

    更新日期:1985-09-01 00:00:00

  • Excess osmolal gap in diabetic ketoacidosis explained.

    abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Davidson DF

    更新日期:1992-05-01 00:00:00

  • 3H and 125I radioimmunoassays of haloperidol compared with fluoroimmunoassay involving antibody coupled to magnetizable solid phase.

    abstract::Radioimmunoassays for haloperidol are described, involving use of tritium- or 125I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also desc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rowell FJ,Hui SM,Kamel SR

    更新日期:1981-07-01 00:00:00

  • Strong association of a single nucleotide substitution in the 3'-untranslated region of the apolipoprotein-CIII gene with common hypertriglyceridemia in Arabs.

    abstract::A potential genetic marker for hypertriglyceridemia and coronary disease, an apolipoprotein-CIII gene allele displaying a single nucleotide substitution, was found in 71% of Arabs with primary hypertriglyceridemia. Over 96% of the unrelated adults possessing this allele showed hypertriglyceridemia. The same allele was...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Taş S

    更新日期:1989-02-01 00:00:00

  • Endothelial nitric oxide synthase gene polymorphisms and risk of coronary artery disease.

    abstract:BACKGROUND:Endothelial nitric oxide synthase (eNOS) could be a candidate gene for coronary artery disease (CAD). This study investigated the relationship of the eNOS Glu(298)-->Asp and T(786)-->C polymorphisms with the presence and severity of CAD in the Italian population. METHODS:We enrolled 415 unrelated individual...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.3.389

    authors: Colombo MG,Paradossi U,Andreassi MG,Botto N,Manfredi S,Masetti S,Biagini A,Clerico A

    更新日期:2003-03-01 00:00:00

  • Significance of serum 24,25-dihydroxyvitamin D in the assessment of vitamin D status: a double-edged sword?

    abstract:BACKGROUND:24,25-Dihydroxyvitamin D [24,25(OH)2D] in serum may be both a nuisance and nutritionally valuable. METHODS:We investigated the impact of 24,25(OH)2D3 on the performance of commercially available immunoassays for serum total 25-hydroxyvitamin D [25(OH)D] using (a) serum from a nationally representative sampl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,随机对照试验

    doi:10.1373/clinchem.2014.234955

    authors: Cashman KD,Hayes A,Galvin K,Merkel J,Jones G,Kaufmann M,Hoofnagle AN,Carter GD,Durazo-Arvizu RA,Sempos CT

    更新日期:2015-04-01 00:00:00

  • Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.

    abstract::This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and rep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gault MH,Longerich L,Dawe M,Vasdev SC

    更新日期:1985-08-01 00:00:00

  • Measurement of ionized calcium in serum with ion-selective electrodes: a mature technology that can meet the daily service needs.

    abstract::This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Bowers GN Jr,Brassard C,Sena SF

    更新日期:1986-08-01 00:00:00

  • Corin is present in the normal human heart, kidney, and blood, with pro-B-type natriuretic peptide processing in the circulation.

    abstract:BACKGROUND:B-type natriuretic peptide (BNP), which is activated in heart failure (HF), is processed to an active form by corin. The corin gene is expressed in the human heart and kidney, but corin protein expression in the heart, kidney, and circulation, along with whether proBNP is processed by circulating corin, rema...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.153908

    authors: Ichiki T,Huntley BK,Heublein DM,Sandberg SM,McKie PM,Martin FL,Jougasaki M,Burnett JC Jr

    更新日期:2011-01-01 00:00:00

  • Minimal disease detection and confirmation in hematologic malignancies: combining cell sorting with clonality profiling.

    abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.061259

    authors: Zehentner BK,Fritschle W,Stelzer T,Ghirardelli KM,Hunter K,Wentzel C,Bennington R,Hansen CL,Myerson D,Kalnoski M,Wells DA,Loken MR

    更新日期:2006-03-01 00:00:00

  • Flash-heater ethylation of some antiepileptic drugs.

    abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Friel P,Troupin AS

    更新日期:1975-05-01 00:00:00

  • Choriogonadotropin measured with the Tandem-E immunoenzymetric assay system.

    abstract::We evaluated the Hybritech Tandem-E procedure for quantifying choriogonadotropin (hCG) in human serum. In this "sandwich"-type assay, two monoclonal antibodies directed against different regions of the hCG molecule are used, one coated on a plastic bead, the second conjugated to alkaline phosphatase. The assay can det...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bock JL,Furgiuele J,Segen JC

    更新日期:1985-03-01 00:00:00

  • Detection of Chromosomal Translocation in Hematologic Malignancies by a Novel DNA-Based Looped Ligation Assay (LOLA).

    abstract:BACKGROUND:Disease-defining chromosomal translocations are seen in various neoplasms, especially in lymphomas and leukemias. Translocation detection at the DNA level is often complicated by chromosomal breakpoints that are distributed over very large regions. We have developed a ligation-based assay [the looped ligatio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2016.270140

    authors: Harada S,Sizzle E,Lin MT,Gocke CD