Abstract:
:I describe a micro-scale method for determining lead in whole blood by utilizing a graphite furnace. Sample pretreatment consists of fivefold dilution with a dilute surfactant. The method is directly calibrated with lead standards prepared in dilute HNO3. To eliminate a small, nonspecific absorption signal from the blood matrix, simultaneous background correction is used. Interlaboratory comparison with a flame atomic absorption technique that requires extraction yielded high correlation (r equal to 0.98). Within-run precision (coefficient of variation) ranged from 2 to 4 percent. Lead in blood can be accurately measured in as little as 20 mul of blood, hence the method is suitable for routine laboratory use and for pediatric screening.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Fernandez FJsubject
Has Abstractpub_date
1975-04-01 00:00:00pages
558-61issue
4eissn
0009-9147issn
1530-8561journal_volume
21pub_type
杂志文章abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-05-01 00:00:00
abstract:BACKGROUND:Lysosomal storage disorders (LSDs) comprise more than 40 genetic diseases that result in the accumulation of products that would normally be degraded by lysosomal enzymes. A tandem mass spectrometry (MS/MS)-based method is available for newborn screening for 5 LSDs, and many laboratories are initiating pilot...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2008.111864
更新日期:2009-01-01 00:00:00
abstract::Published estimates of the imprecision characteristics of immunoassays are often based on quantities of data that seem to be inadequate. The increasing use of imprecision profiles has not necessarily improved the situation. We describe and illustrate a method of computing 95% confidence intervals for profiles estimate...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1990-07-01 00:00:00
abstract::We describe a process for preparing a cholesterol-rich lipoprotein extract from bovine serum. The material is used to enhance cholestrol concentration up to 3.5 g/liter in a clear control material from human serum. The optical clarity of the enriched serum is only slightly affected by lyophilization and reconstitution...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-08-01 00:00:00
abstract::This highly sensitive method for determination of beta 2-microglobulin (beta 2-m) in human urine or serum is based on direct agglutination by beta 2-m of latex particles on which an antibody against beta 2-m is adsorbed. The agglutination is quantified by counting the remaining unagglutinated particles, or by turbidim...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-06-01 00:00:00
abstract::The commonly used methods of assessing the precision of the automated leukocyte differential have certain drawbacks that affect the validity and comparability of results. In the present report, we introduce a procedure based on building precision profiles from a large number of within-run imprecision experiments. The ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-07-01 00:00:00
abstract:BACKGROUND:Efforts to reduce the high global prevalence of nutritional anemia require the use of both reliable laboratory assays to distinguish iron deficiency from other causes of anemia and cost-effective methods for collection of blood specimens under field conditions. The suitability of using small plasma samples s...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-10-01 00:00:00
abstract::Serum folate, pteroylglutamic acid standards, and N-5-methyltetrahydrofolate standards extract differently during sample preparation for radiometric assay. B/B0 values for each material were determined before and after an alkaline extraction procedure. Serum folate most closely resembled N-5-methyltetrahydrofolate sta...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-04-01 00:00:00
abstract::We investigated the efficiency, accuracy, and reliability of the ultrafiltration/dipstick methodology commonly used to diagnose myoglobinuria. Twenty-five myoglobin-containing urine specimens were filtered by centrifugation for 15 min at 1500g through a Centricon-30 membrane filter. Both the original specimen and filt...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract:BACKGROUND:Hyperhomocysteinemia (HHcy) has been linked to impaired left ventricular function and clinical class in patients with chronic heart failure. We hypothesized that HHcy stimulates myocardial brain natriuretic peptide (BNP) expression and induces adverse left ventricular remodeling. METHODS:We randomized 50 ra...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.077859
更新日期:2007-04-01 00:00:00
abstract:BACKGROUND:Increased cardiac troponin concentrations in acute coronary syndrome (ACS) identify patients with ongoing cardiomyocyte necrosis who are at increased risk. However, with the use of more precise assays, cardiac troponin increases are commonly noted in other cardiovascular conditions as well. This has generate...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2016.261495
更新日期:2017-01-01 00:00:00
abstract::We describe a gas-chromatographic method for measuring chlorpromazine and its metabolites chlorpromazine sulfoxide, mono-N-desmethylchlorpromazine, and di-N-desmethylchlorpromazine at therapeutic concentrations in human serum, with use of a nitrogen detector. The compounds are extracted from serum at pH 10.5 into hexa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1979-07-01 00:00:00
abstract:BACKGROUND:Detection of melanoma cells in circulation may be important in assessing tumor progression. The objective of this study was to develop a specific, reliable multimarker quantitative real-time reverse transcription-PCR (qRT) assay for detecting melanoma cells in patients' blood. METHODS:We developed qRT assay...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.045096
更新日期:2005-06-01 00:00:00
abstract::Using results from patients, we studied several methods for long-term (years) monitoring of the analytical stability of various chemistry tests. For each test, we obtained on a bimonthly basis histograms of > or = 200 to approximately 2000 data points and determined the median, mean, and mean of those data points in t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1996-06-01 00:00:00
abstract::We describe a simple, rapid fluorometric assay for separate quantitative analysis of procainamide and N-acetylprocainamide in mixtures. The effective lenear range (fluorescence vs. concentration) in serum is 0.1 to 10.0 mg/liter, regardless of the ratio (by weight) of the two drugs from 1:10 to 10:1. Analytical recove...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-12-01 00:00:00
abstract:BACKGROUND:Hemoglobin-based oxygen carriers (HBOCs) are being developed as potential substitutes for the oxygen-carrying functions of erythrocytes, but athletes may obtain and experiment with HBOCs as an illicit means of enhancing oxygen transport. An electrophoretic technique has been developed to screen for the prese...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.026591
更新日期:2004-04-01 00:00:00
abstract::We have compared the operational, medical, and fiscal consequences of performing urgent glucose testing at the bedside vs in the central laboratory. The turnaround time (TAT) with bedside testing was only 1-2 min shorter than that from the central laboratory, to which specimens are sent by pneumatic tube and from whic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1994-08-01 00:00:00
abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract::Even in the absence of detectable ethanol or visible lipemia, a large plasma osmolal gap is the usual finding in cases of diabetic ketoacidosis. This gap decreases to an insignificant value within 20 h of treatment. Detailed biochemical analysis of six cases showed that, on average, the gap could be almost wholly acco...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-05-01 00:00:00
abstract::Radioimmunoassays for haloperidol are described, involving use of tritium- or 125I-labeled drug or tritium-labeled spiroperidol, and a rabbit antiserum to a drug/bovine serum albumin conjugate. The 125I-labeled drug was prepared by the Chloramine T iodination technique. A fluoroimmunoassay for haloperidol is also desc...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-07-01 00:00:00
abstract::A potential genetic marker for hypertriglyceridemia and coronary disease, an apolipoprotein-CIII gene allele displaying a single nucleotide substitution, was found in 71% of Arabs with primary hypertriglyceridemia. Over 96% of the unrelated adults possessing this allele showed hypertriglyceridemia. The same allele was...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-02-01 00:00:00
abstract:BACKGROUND:Endothelial nitric oxide synthase (eNOS) could be a candidate gene for coronary artery disease (CAD). This study investigated the relationship of the eNOS Glu(298)-->Asp and T(786)-->C polymorphisms with the presence and severity of CAD in the Italian population. METHODS:We enrolled 415 unrelated individual...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.3.389
更新日期:2003-03-01 00:00:00
abstract:BACKGROUND:24,25-Dihydroxyvitamin D [24,25(OH)2D] in serum may be both a nuisance and nutritionally valuable. METHODS:We investigated the impact of 24,25(OH)2D3 on the performance of commercially available immunoassays for serum total 25-hydroxyvitamin D [25(OH)D] using (a) serum from a nationally representative sampl...
journal_title:Clinical chemistry
pub_type: 杂志文章,随机对照试验
doi:10.1373/clinchem.2014.234955
更新日期:2015-04-01 00:00:00
abstract::This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and rep...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-08-01 00:00:00
abstract::This article reviews key advances in ion-selective electrode technology that have made potentiometric measurements of ionized calcium (Ca2+) reliable and precise. Our use of two second-generation Ca2+ analyzers (Radiometer ICA1 and NOVA 8) made possible uninterrupted service as volume increased to 31 640 patient tests...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1986-08-01 00:00:00
abstract:BACKGROUND:B-type natriuretic peptide (BNP), which is activated in heart failure (HF), is processed to an active form by corin. The corin gene is expressed in the human heart and kidney, but corin protein expression in the heart, kidney, and circulation, along with whether proBNP is processed by circulating corin, rema...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2010.153908
更新日期:2011-01-01 00:00:00
abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.061259
更新日期:2006-03-01 00:00:00
abstract::We describe a modification of the MacGee method [Anal. Chem. 42, 421 (1970)] for rapid determination of phenytoin (diphenylhydantoin) in plasma by gas-liquid chromatography, in which an ethylaing reagent is used instead of the more common methylating reagents. With this modification, several N-methylated antiepileptic...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract::We evaluated the Hybritech Tandem-E procedure for quantifying choriogonadotropin (hCG) in human serum. In this "sandwich"-type assay, two monoclonal antibodies directed against different regions of the hCG molecule are used, one coated on a plastic bead, the second conjugated to alkaline phosphatase. The assay can det...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-03-01 00:00:00
abstract:BACKGROUND:Disease-defining chromosomal translocations are seen in various neoplasms, especially in lymphomas and leukemias. Translocation detection at the DNA level is often complicated by chromosomal breakpoints that are distributed over very large regions. We have developed a ligation-based assay [the looped ligatio...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2016.270140
更新日期:2017-07-01 00:00:00