Detection of Chromosomal Translocation in Hematologic Malignancies by a Novel DNA-Based Looped Ligation Assay (LOLA).

Abstract:

BACKGROUND:Disease-defining chromosomal translocations are seen in various neoplasms, especially in lymphomas and leukemias. Translocation detection at the DNA level is often complicated by chromosomal breakpoints that are distributed over very large regions. We have developed a ligation-based assay [the looped ligation assay (LOLA)] to detect translocations from diseases with multiple widely spaced breakpoint hot spots. METHODS:Oligonucleotide sets that probe breakpoints of IGH-BCL2 (immunoglobulin heavy-apoptosis regulator) in follicular lymphoma (FL), MYC-IGH (MYC proto-oncogene, bHLH transcription factor-immunoglobulin heavy) in Burkitt lymphoma (BL) and BCR-ABL1 (RhoGEF and GTPase activating protein-ABL proto-oncogene 1, non-receptor tyrosine kinase) in chronic myelogenous leukemia (CML) were designed. DNA from cell lines with these translocations was mixed with oligonucleotides in a single-step ligation reaction followed by PCR amplification. Detection was by capillary electrophoresis. We also tested peripheral blood from 16 CML patients and frozen tissue from 17 FL cases, and the results were compared to reverse transcription (RT)-PCR (CML) or fluorescent in situ hybridization (FISH) and δ-PCR (FL). RESULTS:LOLA produced signals of the expected sizes for the cell lines. Normal control DNA yielded no signals. A dilution series yielded translocation-specific peaks at dilutions as low as 1%. Signal intensity was log linear to the DNA concentration (R2 = 0.94). Furthermore, we were able to detect a LOLA peak in DNA from 53.3% of FL patients and 87.5% of CML patients. The concordance between LOLA, FISH, and δ-PCR in FL was also excellent. CONCLUSIONS:Our results indicate that LOLA is a simple method that is useful for DNA-based detection of translocations in challenging situations, particularly where the breakpoints are not tightly clustered. The assay also has the added benefit of permitting rapid mapping of the breakpoints.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Harada S,Sizzle E,Lin MT,Gocke CD

doi

10.1373/clinchem.2016.270140

subject

Has Abstract

pub_date

2017-07-01 00:00:00

pages

1278-1287

issue

7

eissn

0009-9147

issn

1530-8561

pii

clinchem.2016.270140

journal_volume

63

pub_type

杂志文章
  • Adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood compared for clinical evaluation of patients with disorders of calcium metabolism.

    abstract::We report results for adjusted ionized calcium (at pH 7.4) and actual ionized calcium (at actual pH) in capillary blood from 183 patients with disorders of calcium metabolism (primary hyperparathyroidism, secondary hyperparathyroidism of malabsorption, primary hypoparathyroidism, Paget's disease, acromegaly, hypercalc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thode J,Holmegaard SN,Transbøl I,Fogh-Andersen N,Siggaard-Andersen O

    更新日期:1990-03-01 00:00:00

  • Rapid liquid chromatography-tandem mass spectrometry method for routine analysis of cyclosporin A over an extended concentration range.

    abstract:BACKGROUND:Cyclosporin A (CsA) is commonly measured by immunoassay techniques that have a limited analytical range. The consequence of this is that low CsA concentrations that may be clinically significant are difficult to measure and that high concentrations require sample dilution, which introduces error and increase...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Keevil BG,Tierney DP,Cooper DP,Morris MR

    更新日期:2002-01-01 00:00:00

  • Capillary gas-chromatographic determination of urinary homovanillic acid and vanillylmandelic acid.

    abstract::This relatively simple, rapid method for quantification of homovanillic acid (HVA) and vanillylmandelic acid (VMA) involves solvent extraction and capillary gas chromatography. With use of this extraction method, the overall analytical recovery from an aqueous solution is 92.5% for HVA and 79.2% for VMA. 3,4-Dihydroxy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tuchman M,Crippin PJ,Krivit W

    更新日期:1983-05-01 00:00:00

  • 99th Percentile Upper-Reference Limit of Cardiac Troponin and the Diagnosis of Acute Myocardial Infarction.

    abstract:BACKGROUND:Concerns exist regarding how the 99th percentile upper reference limit (URL) of cardiac troponin (cTn) is determined and whether it should be derived from normal healthy individuals. CONTENT:The 99th percentile URL of cTn is an important criterion to standardize the diagnosis of myocardial infarction (MI) f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa158

    authors: Sandoval Y,Apple FS,Saenger AK,Collinson PO,Wu AHB,Jaffe AS

    更新日期:2020-09-01 00:00:00

  • Immunochemical detection of group I and group II phospholipases A2 in human serum.

    abstract::Time-resolved fluoroimmunoassay was developed for the detection of synovial-type phospholipase A2 (s-PLA2) in human serum. This solid-phase, sandwich assay uses a polyclonal rabbit antibody raised against synovial-type group II PLA2 produced in Escherichia coli. No cross-reactions were detected between s-PLA2 and PLA2...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nevalainen TJ,Kortesuo PT,Rintala E,Märki F

    更新日期:1992-09-01 00:00:00

  • Clinical evaluation of the Triage analytic device for drugs-of-abuse testing.

    abstract::In the present clinical evaluation of Triage immunoassay for detection of drugs of abuse, we examined a possible connection between the laboratory skills of the personnel using it and the quality of analytical results; we also evaluated the degree of concordance between the Triage results and those obtained by an inst...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: de la Torre R,Domingo-Salvany A,Badia R,Gonzàlez G,McFarlane D,San L,Torrens M

    更新日期:1996-09-01 00:00:00

  • Measurement of glycosylated hemoglobin on cellulose acetate membranes by mobile affinity electrophoresis.

    abstract::In this method for separating glycosylated from nonglycosylated hemoglobin in blood by electrophoresis on cellulose acetate membranes, we exploit the affinity of low-molecular-mass dextran sulfate for the nonglycosylated fraction, which increases the mobility of the latter relative to that of glycosylated hemoglobin. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ambler J,Janik B,Walker G

    更新日期:1983-02-01 00:00:00

  • Limitations of Accelerated Stability Model Based on the Arrhenius Equation for Shelf Life Estimation of In Vitro Diagnostic Products.

    abstract:BACKGROUND:An accelerated stability model based on the Arrhenius Equation can be used to estimate stability of diagnostic reagents. Here we review 3 examples in which the model does not accurately predict the stability of diagnostic reagents. METHODS:We prepared several pilot lots of quality controls materials contain...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa282

    authors: Ebrahim A,DeVore K,Fischer T

    更新日期:2020-12-04 00:00:00

  • Report of the National Heart, Lung, and Blood Institute Workshop on Lipoprotein(a) and Cardiovascular Disease: recent advances and future directions.

    abstract::It has been estimated that approximately 37% of the US population judged to be at high risk for developing coronary artery disease (CAD), based on the National Cholesterol Education Program guidelines, have increased plasma lipoprotein(a) [Lp(a)], whereas Lp(a) is increased in only 14% of those judged to be at low ris...

    journal_title:Clinical chemistry

    pub_type:

    doi:10.1373/clinchem.2003.023689

    authors: Marcovina SM,Koschinsky ML,Albers JJ,Skarlatos S

    更新日期:2003-11-01 00:00:00

  • Radioimmunoassay for arylsulfatase A in urine.

    abstract::Purified arylsulfatase A (EC 3.1.6.1) from human urine was radioiodinated under conditions that caused no significant loss of antigenic activity. We used this labeled arylsulfatase A (specific radioactivity 4-7.5 Ci/g) together with nonlabeled enzyme and rabbit antiserum produced against homogeneous enzyme to develop ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Laidler PM,Ryder KW,Glick MR,Oei TO,Van Etten RL

    更新日期:1985-03-01 00:00:00

  • Autoimmune endocrinopathies: aspects of pathogenesis and the role of immune assays in investigation and management.

    abstract::It has been hypothesized over many years that the autoimmune endocrine diseases are each due to antigen-specific defects in suppressor (regulatory) T lymphocyte function. There is now increasing evidence in studies of autoimmune thyroid disease and insulin-dependent diabetes mellitus that suppressor cells are activate...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Volpé R

    更新日期:1994-11-01 00:00:00

  • Laboratory evaluation of the Boehringer Mannheim "Diagnostic M" automated discrete analyzer.

    abstract::We evaluated a new multiple-channel chemistry analyzer, the Boehringer Mannheim "Diagnostic M." This instrument can perform 25 tests at the rate of 120 1.3-mL serum samples per hour. The instrument may be run in either a profile mode or single-test mode. In the single-test mode only the necessary reagent is pumped. th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Robinson CA,Proelss H,Stabler TV

    更新日期:1982-01-01 00:00:00

  • Specific assay of serum lactate dehydrogenase isoenzyme 1 by proteolysis with alpha-chymotrypsin and protein denaturation.

    abstract::We devised a method for assaying serum lactate dehydrogenase isoenzyme 1 (LD-1) activity specifically by preincubation with alpha-chymotrypsin and guanidine. Cleavage of phenylalanine bonds in the loop of A and B subunits of LD-3, LD-4, and LD-5 isoenzymes (residues 117-119) by incubation with alpha-chymotrypsin for a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shirahase Y,Watazu Y,Kaneda N,Uji Y,Okabe H,Karmen A

    更新日期:1992-11-01 00:00:00

  • Cardiac troponin T predicts long-term outcomes in hemodialysis patients.

    abstract:BACKGROUND:Increased plasma troponin T (cTnT), but not troponin I (cTnI), is frequently observed in end-stage renal failure patients. Although generally considered spurious, we previously reported an associated increased mortality at 12 months. METHODS:We studied long-term outcomes in 244 patients on chronic hemodialy...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ooi DS,Zimmerman D,Graham J,Wells GA

    更新日期:2001-03-01 00:00:00

  • Automated creatine kinase-MB estimation by immuno-inhibition: a clinical evaluation.

    abstract::We detected the presence of creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) in serum by using an immunoinhibition technique to inactivate the creatine kinase isoenzyme of muscle origin (CK-MM). The GEMSAEC centrifugal analyzer is ideally suited for this procedure because it rapidly mixes reagents and has a throughpu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Delahunty TJ,Foreback CC

    更新日期:1980-04-01 00:00:00

  • A kinetic standard for precise calibration of spectrophotometer cell temperature.

    abstract::We describe a simple, highly reproducible kinetic technique for precisely measuring temperature in spectrophotometric systems having reaction cells that are inaccessible to conventional temperature probes. The method is based on the temperature dependence of pseudo-first-order rate constants for the acid-catalyzed hyd...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Adams PA,Berman MC

    更新日期:1981-05-01 00:00:00

  • Analytical performance of EMIT cyclosporine assay evaluated.

    abstract::We evaluated the EMIT Cyclosporine Assay (Syva Co., Palo Alto, CA), using the Cobas-Mira analyzer to assess the precision, accuracy, and analytical recovery from whole-blood samples supplemented with cyclosporine. We also performed comparative analysis of whole-blood samples containing cyclosporine from liver and kidn...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dasgupta A,Saldana S,Desai M

    更新日期:1991-12-01 00:00:00

  • An inter- and intralaboratory quality-control survey of radioimmunoassay of insulin, thyroxin, thyrotropin, cortisol, digoxin, gastrin, beta 2-microglobulin, and IgE in Japan with commercially available kits.

    abstract::We report results of a quality-control survey of radioimmunoassay (RIA) of eight analytes, participated in by 249 laboratories of various types throughout Japan. For the purpose of the external control survey, lyophilized specimens containing two different concentrations of each analyte were sent to the participating ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shishiba Y,Irie M,Yamada H,Kinoshita F

    更新日期:1983-08-01 00:00:00

  • Hyperhomocysteinemia and myocardial expression of brain natriuretic peptide in rats.

    abstract:BACKGROUND:Hyperhomocysteinemia (HHcy) has been linked to impaired left ventricular function and clinical class in patients with chronic heart failure. We hypothesized that HHcy stimulates myocardial brain natriuretic peptide (BNP) expression and induces adverse left ventricular remodeling. METHODS:We randomized 50 ra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.077859

    authors: Herrmann M,Taban-Shoma O,Hübner U,Pexa A,Kilter H,Umanskaya N,Straub RH,Böhm M,Herrmann W

    更新日期:2007-04-01 00:00:00

  • Virus-coated layer-by-layer colloids as a multiplex suspension array for the detection and quantification of virus-specific antibodies.

    abstract:BACKGROUND:Suspension array technology has surpassed ELISA for automated, simultaneous detection and quantification of soluble biomarkers such as virus-specific antibodies. We describe assays in which antigens are attached to a lipid bilayer surrounding color-coded particles. METHODS:We used layer-by-layer technology ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065789

    authors: Toellner L,Fischlechner M,Ferko B,Grabherr RM,Donath E

    更新日期:2006-08-01 00:00:00

  • Liquid-chromatographic measurement of taurine in cerebrospinal fluid of normal individuals and patients with meningitis.

    abstract::Taurine was measured in cerebrospinal fluid by reacting it with fluorescamine to form a fluorescent derivative, followed by separation on a reversed-phase column and fluorometric detection and evaluation. The assay is rapid (17 min) and sensitive to as little as 1 mumol/L. The mean value for 27 cerebrospinal fluid sam...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,White JP

    更新日期:1979-08-01 00:00:00

  • Optimized serum pancreolauryl test for differentiating patients with and without chronic pancreatitis.

    abstract::The serum pancreolauryl test has limited sensitivity for detecting mild pancreatic insufficiency. The aim of this study was to optimize the serum pancreolauryl test so as to increase the probability of positive results in patients with chronic pancreatitis. The study had three parts. First, the sampling time was optim...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Domínguez-Muñoz JE,Malfertheiner P

    更新日期:1998-04-01 00:00:00

  • Comparison of quality-control rules used in clinical chemistry laboratories.

    abstract::Numerous papers have been written to show which combinations of Shewhart-type quality-control charts are optimal for detecting systematic shifts in the mean response of a process, increases in the random error of a process, and linear drift effects in the mean response across the assay batch. One paper by Westgard et ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bishop J,Nix AB

    更新日期:1993-08-01 00:00:00

  • Fixed-time kinetic assay of plasma ammonia, with NADPH as cofactor, with a centrifugal analyzer.

    abstract::We describe a fixed-time, enzymatic, reaction-rate procedure for determining plasma ammonia with a centrifugal analyzer (Rotochem IIA/36; American Instrument Co., silver Spring, MD 20910), with NADPH as cofactor. The reaction is based on that of da Fonseca-Wollheim's modification [J. Clin. Chem. Clin. Biochem. 11, 421...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Li PK,Shull BC

    更新日期:1979-04-01 00:00:00

  • Kinetic studies of a quantitative single-tube enzyme-linked immunosorbent assay.

    abstract::We describe a single-cuvette enzyme-linked immunosorbent assay (ELISA) based on enzymic rate kinetics. This kinetic assay can yield linear quantitative data on immunoglobin concentrations. Optimum assay conditions, component concentrations, reaction intervals, and pH are described. Assay linearity and sensitivity are ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsang VC,Wilson BC,Maddison SE

    更新日期:1980-08-01 00:00:00

  • Improved measurement of acetylsalicylic acid esterase in serum.

    abstract::A fixed-time incubation method for measuring acetylsalicylic acid esterase was improved by using a higher concentration of the substrate, acetylsalicylic acid, and an activator, Ca2+. The enzymatic activity in serum was 25-fold that measured by earlier methods. Inhibition studies showed a pattern similar to that repor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sørensen S

    更新日期:1983-03-01 00:00:00

  • Decreased storage stability of creatine kinase in a cardiac reperfusion solution.

    abstract::Creatine kinase (CK; EC 2.7.3.2) has been used as an indicator of myocardial cellular damage. In this study we used a Krebs-Henseleit (KH) solution to reperfuse isolated rat hearts after 24 h of cold preservation and collected the KH reperfusate for assay of CK to assess cellular damage. We wanted to determine the sta...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dunphy G,Ely D

    更新日期:1990-05-01 00:00:00

  • Prospective Associations of Systemic and Urinary Choline Metabolites with Incident Type 2 Diabetes.

    abstract:BACKGROUND:Several compounds in the choline oxidation pathway are associated with insulin resistance and prevalent diabetes; however, prospective data are scarce.We explored the relationships between systemic and urinary choline-related metabolites and incident type 2 diabetes in an observational prospective study amon...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2015.250761

    authors: Svingen GF,Schartum-Hansen H,Pedersen ER,Ueland PM,Tell GS,Mellgren G,Njølstad PR,Seifert R,Strand E,Karlsson T,Nygård O

    更新日期:2016-05-01 00:00:00

  • Evaluation of a near-patient test for C-reactive protein used in daily routine in primary healthcare by use of difference plots.

    abstract::We have assessed the technical performance and robustness of NycoCard CRP Whole Blood, a near-patient test for C-reactive protein (CRP), when used in realistic daily routine situations in general practice clinics (GPC). Thirteen GPCs participated, five of them with technician staff. From 898 patients, split-sample mea...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dahler-Eriksen BS,Lassen JF,Petersen PH,Lund ED,Lauritzen T,Brandslund I

    更新日期:1997-11-01 00:00:00

  • Calcineurin activity assay measurement by liquid chromatography-tandem mass spectrometry in the multiple reaction monitoring mode.

    abstract:BACKGROUND:Blood concentrations of the calcineurin inhibitors (CNIs) cyclosporine and tacrolimus are currently measured to monitor immunosuppression in transplant patients. The measurement of calcineurin (CN) phosphatase activity has been proposed as a complementary pharmacodynamic approach. However, determining CN act...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.213264

    authors: Carr L,Gagez AL,Essig M,Sauvage FL,Marquet P,Gastinel LN

    更新日期:2014-02-01 00:00:00