Combined liquid chromatography/radioimmunoassay with improved specificity for serum digoxin.

Abstract:

:This method for assaying digoxin in serum with improved specificity combines small-column extraction of serum, "high-performance" liquid chromatography, and RIA of the eluted fractions. Analytical recoveries of 1.0, 0.5, and 0.1 microgram/L standards were 95%, 93%, and 84%, respectively. The CVs for duplicates and replicates of sera with values of 0.5 to 1 microgram/L were 4 to 6%. Fifty-nine sera from 50 patients receiving digoxin were so studied. All digoxin metabolites appear to cross react with antibody to digoxin to various degrees. The most polar metabolites were quantitatively the most important, their average cross reactivity being 33%. For eight patients the value for digoxin by the present method was less than 60% of the RIA value. Sera from nine patients not taking digoxin but with falsely high digoxin values were also studied by the present method. The digoxin peak was well resolved from those for (a) digoxin metabolites (except dihydrodigoxin), (b) digitalis-like factors in neonates and in patients with renal failure or combined hepatic and renal failure, and (c) two cross reacting drugs and their metabolites.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Gault MH,Longerich L,Dawe M,Vasdev SC

subject

Has Abstract

pub_date

1985-08-01 00:00:00

pages

1272-7

issue

8

eissn

0009-9147

issn

1530-8561

journal_volume

31

pub_type

杂志文章
  • Homogeneous apoenzyme reactivation immunoassay for thyroxin-binding globulin in serum.

    abstract::In this automated apoenzyme reactivation immunoassay system (Ames Optimate) for thyroxin-binding globulin (TBG), the sample and N6-aminohexylflavin adenine dinucleotide-labeled TBG react sequentially with antiserum. Then apoglucose oxidase is added to combine with the free fraction and generate glucose oxidase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schroeder HR,Johnson PK,Dean CL,Morris DL,Smith D,Refetoff S

    更新日期:1986-05-01 00:00:00

  • Radioimmunoassay for amatoxins by use of a rapid, 125I-tracer-based system.

    abstract::In this new radioimmunoassay system for determination of amatoxins in urine and plasma, a novel chemical approach is used for antigen and 125I-tracer production, based on a detoxified alpha-amanitin derivative (aldoamanitin). Total assay time, including data processing, is less than 100 min. The lowest detectable conc...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Andres RY,Frei W,Gautschi K,Vonderschmitt DJ

    更新日期:1986-09-01 00:00:00

  • Human pharmacokinetics of L-3,4-dihydroxyphenylalanine studied with microdialysis.

    abstract:BACKGROUND:Intravenous and subcutaneous microdialysis was performed to compare the free concentrations and pharmacokinetics of L-3, 4-dihyroxyphenylalanine (L-dopa) in blood and tissue in healthy subjects and in patients with Parkinson disease. METHODS:Nine healthy volunteers and 10 patients with Parkinson disease, st...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:

    authors: Dizdar N,Kullman A,Norlander B,Olsson JE,Kagedal B

    更新日期:1999-10-01 00:00:00

  • HPLC for simultaneous quantification of total ceramide, glucosylceramide, and ceramide trihexoside concentrations in plasma.

    abstract:BACKGROUND:Simple, reproducible assays are needed for the quantification of sphingolipids, ceramide (Cer), and sphingoid bases. We developed an HPLC method for simultaneous quantification of total plasma concentrations of Cer, glucosylceramide (GlcCer), and ceramide trihexoside (CTH). METHODS:After addition of sphinga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.079012

    authors: Groener JE,Poorthuis BJ,Kuiper S,Helmond MT,Hollak CE,Aerts JM

    更新日期:2007-04-01 00:00:00

  • New noncompetitive immunoassays of small analytes.

    abstract::We developed a novel noncompetitive immunoassay format for monoepitopic analytes and describe here a model assay for triiodothyronine (T3), performed on Ciba Corning's ACS:180 analyzer. Acridinium ester (AE)-labeled bivalent anti-T3 was incubated with the sample, producing AE-anti-T3/T3 complexes and unreacted AE-anti...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Piran U,Riordan WJ,Livshin LA

    更新日期:1995-07-01 00:00:00

  • Fast lipoprotein chromatography: new method of analysis for plasma lipoproteins.

    abstract::Fast lipoprotein chromatography (FLPC) is a novel method for quantifying lipoproteins. Plasma proteins are separated by fast-flow gel filtration. Lipoproteins are detected by post-column derivatization with an enzymatic cholesterol reagent. FLPC resolves very-low-, low-, and high-density lipoproteins (VLDL, LDL, and H...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: März W,Siekmeier R,Scharnagl H,Seiffert UB,Gross W

    更新日期:1993-11-01 00:00:00

  • Specific 125I-radioimmunoassay for cholyglycine, a bile acid, in serum.

    abstract::The concentration of the conjugated bile acid, cholylglycine, in serum is a sensitive and specific indicator of hepatic function. We describe a convenient, specific, and precise radioimmunoassay for cholylglycine, in which 125I-labeled cholylglycyltyrosine is used as tracer. In addition, a blocking agent in the buffer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Miller P,Weiss S,Cornell M,Dockery J

    更新日期:1981-10-01 00:00:00

  • Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

    abstract:BACKGROUND:The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS:We tested 18 specimens after centrifuga...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.6.935

    authors: Grenache DG,Parvin CA,Gronowski AM

    更新日期:2003-06-01 00:00:00

  • Clinical sensitivity and specificity of meconium fatty acid ethyl ester, ethyl glucuronide, and ethyl sulfate for detecting maternal drinking during pregnancy.

    abstract:BACKGROUND:We investigated agreement between self-reported prenatal alcohol exposure (PAE) and objective meconium alcohol markers to determine the optimal meconium marker and threshold for identifying PAE. METHODS:Meconium fatty acid ethyl esters (FAEE), ethyl glucuronide (EtG), and ethyl sulfate (EtS) were quantified...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2014.233718

    authors: Himes SK,Dukes KA,Tripp T,Petersen JM,Raffo C,Burd L,Odendaal H,Elliott AJ,Hereld D,Signore C,Willinger M,Huestis MA,Prenatal Alcohol in SIDS and Stillbirth (PASS) Network.

    更新日期:2015-03-01 00:00:00

  • Liquid-phase reactions started by rehydrating lyophilized reagents in a centrifugal analyzer.

    abstract::In the disposable rotor of the SAM microcentrifugal analyzer, various lyophilized reagents are predistributed in 24 33-microL cuvets, for determination of multiple analytes in one specimen (e.g., for patient profiles). We evaluated a prototype of this system, which can be used at 25, 30, or 37 degrees C; absorbance re...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Truchaud A,Glikmanas G,Gourmelin Y,Hersant J,Trepo D,Foray G,Collombel C

    更新日期:1985-09-01 00:00:00

  • Stabilized analysis of antidepressant drugs by solvent-recycled liquid chromatography: procedure and proposed resolution mechanisms for chromatography.

    abstract::In this efficient extraction and isocratic liquid-chromatographic procedure for measuring eight antidepressant drugs in serum (amoxapine, 8-hydroxyamoxapine, doxepin, desmethyldoxepin, imipramine, desipramine, amitriptyline, and nortriptyline), they are extracted from serum as a group by use of disposable solid-phase ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lensmeyer GL,Evenson MA

    更新日期:1984-11-01 00:00:00

  • Serum free light chain ratio, total kappa/lambda ratio, and immunofixation results are not prognostic factors after stem cell transplantation for newly diagnosed multiple myeloma.

    abstract:BACKGROUND:The prognostic value of changes in paraprotein markers after stem cell transplantation is unknown. We evaluated disease response using serum immunofixation (s-IFIX), total kappa and lambda ratio (KLR), and free light chain (FLC) ratio in myeloma patients who underwent autologous or autologous plus allogeneic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.124370

    authors: Giarin MM,Giaccone L,Sorasio R,Sfiligoi C,Amoroso B,Cavallo F,Cipriani A,Palumbo A,Boccadoro M

    更新日期:2009-08-01 00:00:00

  • Induction of O-deethylase activity as an index to exposure to coal-derived products and trace environmental pollutants.

    abstract::The metabolism of the synthetic substrate 7-ethoxyresorufin is a selective measure of the activity of cytochrome P-448 monooxygenase, the subset of cytochrome P-450-mediated enzymes preferentially induced by polycyclic aromatic hydrocarbons and related compounds. 7-Ethoxycoumarin metabolism, on the other hand, reflect...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bostick WD,Kao J,Holland JM,Mrochek JE

    更新日期:1981-09-01 00:00:00

  • Felbamate measured in serum by two methods: HPLC and capillary electrophoresis.

    abstract::We have developed two methods for determining serum concentrations of felbamate, a new anticonvulsant drug. The first method is based on protein precipitation with acetonitrile, followed by HPLC. The between-run CV for this method is 5.7% (mean 55 mg/L), and the linearity extends from 5 to 175 mg/L. Results by this me...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shihabi ZK,Oles KS

    更新日期:1994-10-01 00:00:00

  • A computerized classification technique for screening for the presence of breath biomarkers in lung cancer.

    abstract::A simple computer-based screening technique has been developed for classifying human expired air components into 16 chemical classes, based on empirical formulas. The sort procedure was developed to simplify the screening of the composition of expired air samples by sorting all components into chemical classes and cla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: O'Neill HJ,Gordon SM,O'Neill MH,Gibbons RD,Szidon JP

    更新日期:1988-08-01 00:00:00

  • A monoclonal-antibody-based radioimmunoassay for measurement of protein C in plasma.

    abstract::A monoclonal-antibody-based competitive radioimmunoassay for measuring human protein C is reported. With use of a purified protein C standard, the solid-phase assay was sensitive to less than 80 micrograms of protein C per liter. Intraassay CVs ranged from 5% to 8%; the inter-assay CV was 5.4%. Analytical recovery ave...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Howard PR,Bovill EG,Mann KG,Tracy RP

    更新日期:1988-02-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Estimating glomerular filtration rate in kidney transplantation: is the new chronic kidney disease epidemiology collaboration equation any better?

    abstract:BACKGROUND:The new Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation was developed to address the systematic underestimation of the glomerular filtration rate (GFR) by the Modification of Diet in Renal Disease (MDRD) Study equation in patients with a relatively well-preserved kidney function. The per...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.135111

    authors: White CA,Akbari A,Doucette S,Fergusson D,Knoll GA

    更新日期:2010-03-01 00:00:00

  • Biological and clinical significance of haptoglobin polymorphism in humans.

    abstract::Haptoglobin is a hemoglobin-binding protein expressed by a genetic polymorphism as three major phenotypes: 1-1, 2-1, and 2-2. Most attention has been paid to determining haptoglobin phenotype as a genetic fingerprint used in forensic medicine. More recently, several functional differences between haptoglobin phenotype...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Langlois MR,Delanghe JR

    更新日期:1996-10-01 00:00:00

  • Development of a multichannel electrochemical centrifugal analyzer.

    abstract::A new instrument has been developed that is similar in design and concept to the GeMSAEC centrifugal analyzer (Oak Ridge National Laboratory) except that electrochemical detection is used rather than optical detection. The present version has eight channels, each with its own detector. Problems of speed control and sa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cho HK,Lee YH,Couch RA,Jagadeesh JM,Olson CL

    更新日期:1982-09-01 00:00:00

  • Is succinyldicholine the substrate of choice for the measurement of cholinesterase activity?

    abstract::We have developed a succinyldicholine-based assay for serum cholinesterase (EC 3.1.1.8) to help establish whether patients with suspected sensitivity to drugs of this type have enzyme abnormalities that cannot be detected by conventional laboratory techniques. Although the method discriminates between cholinesterase a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Faye S,Evans RT

    更新日期:1986-08-01 00:00:00

  • Improved biuret procedure for routine determination of urinary total proteins in clinical proteinuria.

    abstract::This communication describes and evaluates an improved routine methodology for quantitating clinical proteinuria. Based on investigations of Piscator and of Savory et al., a modified Tsuchiya's reagent (ethanolic HCI-phosphotungstic acid) is used to precipitate proteins at 56 degrees C, followed by biuret spectrophoto...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rice EW

    更新日期:1975-03-01 00:00:00

  • Continuous-flow determination of dialyzable calcium in serum.

    abstract::We describe a procedure for measuring dialyzable calcium in 60 sera per hour with use of AutoAnalyzer (Technicon) modules. The serum is buffered, then dialyzed in a regular 6-inch (15-cm) dialysis block. A constant proportion of the dialyzable calcium is fluorometrically measured. Analysis of samples containing protei...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Toffaletti J,Savory J,Gitelman HJ

    更新日期:1977-07-01 00:00:00

  • Unpredictable fluctuations in transcutaneous pCO2 from capillary blood gas determinations.

    abstract::Transcutaneous pCO2 electrode response time was optimized by use of a new electrode filling solution composed of NaCl/NaHCO3 electrolyte buffer (100 and 20 mmol/L, respectively) in an equivolume mixture of glycerol and water. The 95% response time to a step change in pCO2 was 49.9 +/- 2.8 s (mean +/- SD) when there wa...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kost GJ,Chow JL,Kenny M

    更新日期:1982-07-01 00:00:00

  • Mitochondrial aspartate aminotransferase determined by "Fast Protein Liquid Chromatography".

    abstract::We describe an improved separation of the isoenzymes of aspartate aminotransferase (EC 2.6.1.1), based on ion-exchange chromatography. Involving the "Fast Protein Liquid Chromatography" system (Pharmacia) with a MonoQ column, this rapid, reproducible method for quantifying the mitochondrial enzyme shows good resolutio...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Grøstad M,Rej R,Huseby NE

    更新日期:1990-02-01 00:00:00

  • Liquid-chromatographic determination of guanidino compounds in plasma and erythrocyte of normal persons and uremic patients.

    abstract::We describe a method for determination of guanidino compounds in plasma and erythrocytes. The compounds are separated by liquid chromatography, the concentrations in the effluent being estimated fluorometrically (Trans. Am. Soc. Artif. Intern. Organs 24: 61, 1978). Guanidinoacetic acid, guanidinosuccinic acid, guanidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kikuchi T,Orita Y,Ando A,Mikami H,Fujii M,Okada A,Abe H

    更新日期:1981-11-01 00:00:00

  • Diagnostic and prognostic value of laboratory tests assessed in a follow-up study of 200 patients with liver disease.

    abstract::Two hundred patients with liver disease were re-studied after six to eight years. The initial routine diagnosis (mainly based on morphological criteria) was confirmed in almost 80% of cases of chronic liver disease. In chronic active hepatitis, agreement was found in 86%. An alternative classification based on cluster...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Skrede S,Solberg HE,Ritland S,Blomhoff JP,Schrumpf E,Elgjo K,Gjone E

    更新日期:1982-05-01 00:00:00

  • Serum-constituents analyses: effect of duration and temperature of storage of clotted blood.

    abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ono T,Kitaguchi K,Takehara M,Shiiba M,Hayami K

    更新日期:1981-01-01 00:00:00

  • Direct solid-phase time-resolved immunofluorometric assay of cortisol in serum.

    abstract::A dissociation-enhanced lanthanide fluoroimmunoassay of serum cortisol based on time-resolved fluorescence is described. The assay is a direct assay, where cortisol immobilized on the wall of a microtiter-strip well competes with cortisol in the sample for the europium-labeled polyclonal antibody. The amount of bound ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Eskola JU,Näntö V,Meurling L,Lövgren TN

    更新日期:1985-10-01 00:00:00

  • Response-surface-optimized, zinc-enhanced assay for serum alkaline phosphatase.

    abstract::An optimized assay for alkaline phosphatase (EC 3.1.3.1) is reported. A discrete analyzer, the DuPont Automatic Clinical Analyzer (aca), was used for this study. The assay is based on results of response-surface experimental co-optimization techniques, and response is enhanced over the present aca assay. A key feature...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thompson JC,Hodges CT,Dobler GL,Williamson JA Jr

    更新日期:1981-07-01 00:00:00