Mitochondrial aspartate aminotransferase determined by "Fast Protein Liquid Chromatography".

Abstract:

:We describe an improved separation of the isoenzymes of aspartate aminotransferase (EC 2.6.1.1), based on ion-exchange chromatography. Involving the "Fast Protein Liquid Chromatography" system (Pharmacia) with a MonoQ column, this rapid, reproducible method for quantifying the mitochondrial enzyme shows good resolution and sensitivity, and results correlate well with those by an established immunochemical method.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Grøstad M,Rej R,Huseby NE

subject

Has Abstract

pub_date

1990-02-01 00:00:00

pages

348-50

issue

2

eissn

0009-9147

issn

1530-8561

journal_volume

36

pub_type

杂志文章
  • Multicenter harmonization of common enzyme results by fresh patient-pool sera.

    abstract::A region consisting of 19 clinical laboratories harmonized their calibration of seven common enzymes by using fresh patient-pool sera. One of the laboratories was chosen to act as Regional Reference Laboratory (RRL). This laboratory used internationally accepted (mostly IFCC) methods at 37 degrees C, with an intralabo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Franck PF,Steen G,Lombarts AJ,Souverijn JH,van Wermeskerken RK

    更新日期:1998-03-01 00:00:00

  • Determination of beta-choriogonadotropin in human plasma; evaluation and comparison of five "kit" methods.

    abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Knox BS,McKee JW,Hair PI,France JT

    更新日期:1980-12-01 00:00:00

  • Tartrate-resistant acid phosphatase isoform 5b as serum marker for osteoclastic activity.

    abstract:BACKGROUND:Tartrate-resistant acid phosphatase (AcP) 5b is a marker of osteoclastic activity and bone resorption. Immunoassays for serum TRAcP may lack sensitivity and specificity because of the presence of non-bone isoform 5a. The purpose of this study was to isolate the serum isoforms, quantify their disease-related ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Janckila AJ,Takahashi K,Sun SZ,Yam LT

    更新日期:2001-01-01 00:00:00

  • Iron stores, blood donation, and insulin sensitivity and secretion.

    abstract:BACKGROUND:Epidemiologists have observed that blood donation is associated with decreased risk of type 2 diabetes and cardiovascular disease. METHODS:We investigated the relationship between iron stores and insulin sensitivity, after controlling for known confounding factors, and compared insulin sensitivity between b...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.046847

    authors: Fernández-Real JM,López-Bermejo A,Ricart W

    更新日期:2005-07-01 00:00:00

  • Comprehensive one-step molecular analyses of mitochondrial genome by massively parallel sequencing.

    abstract:BACKGROUND:Mitochondrial diseases are clinically and genetically heterogeneous, with variable penetrance, expressivity, and differing age of onset. Disease-causing point mutations and large deletions in the mitochondrial genome often exist in a heteroplasmic state. Current molecular analyses require multiple different ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2011.181438

    authors: Zhang W,Cui H,Wong LJ

    更新日期:2012-09-01 00:00:00

  • IgG heavy-chain subclass typing of myeloma paraproteins by isoelectric focusing immunoblot analysis.

    abstract::The objective of this study was to develop a clinical laboratory method for subclass typing of human immunoglobulin G (IgG) paraproteins. Serum proteins were isoelectrically focused (IEF) in a mini-gel and passively blotted by capillary diffusion onto untreated nitrocellulose. Unreacted sites on the nitrocellulose wer...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fasullo FJ Jr,Fritsche HA Jr,Liu FJ,Hamilton RG

    更新日期:1989-03-01 00:00:00

  • Detection of benzodiazepine intake in therapeutic doses by immunoanalysis of urine: two techniques evaluated and modified for improved performance.

    abstract::We evaluated the EMIT (enzyme-multiplied immuno technique) and FPIA (fluorescence polarization immunoassay) urine screening systems for detection of benzodiazepine intake. Healthy male volunteers were given single oral therapeutic doses of alprazolam (2 mg), chlordiazepoxide (25 mg), flunitrazepam (1 mg), lorazepam (3...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Beck O,Lafolie P,Hjemdahl P,Borg S,Odelius G,Wirbing P

    更新日期:1992-02-01 00:00:00

  • Coagulation and bleeding disorders: review and update.

    abstract::Hemostasis is initiated by injury to the vascular wall, leading to the deposition of platelets adhering to components of the subendothelium. Platelet adhesion requires the presence of von Willebrand factor and platelet receptors (IIb/IIIa and Ib/IX). Additional platelets are recruited to the site of injury by release ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Triplett DA

    更新日期:2000-08-01 00:00:00

  • Hydroxyurea interferes negatively with triglyceride measurement by a glycerol oxidase method.

    abstract::Measured triglyceride concentrations were extremely low (less than 100 mg/L) in the serum of some patients who were receiving hydroxyurea for myeloproliferative diseases. The assay being used to quantify triglycerides was a "cascaded" enzymatic method involving (a) lipase, to generate glycerol from triglycerides; (b) ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McPherson RA,Brown KD,Agarwal RP,Threatte GA,Jacobson RJ

    更新日期:1985-08-01 00:00:00

  • Manual fluorometry of phenylalanine from blood specimens collected on filter paper: a modified procedure.

    abstract::In this manual fluorometric method, blood samples are used that have been impregnated on the filter paper, a convenient collection technique that is widely used to screen newborns for phenylketonuria. The modified procedure, based on the method of McCaman and Robins [J. Lab Clin. Med. 59, 885 (1962)], includes elution...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu JT,Wu LH,Ziter FA,Ash KO

    更新日期:1979-03-01 00:00:00

  • Total serum cholesterol by isotope dilution/mass spectrometry: a candidate definitive method.

    abstract::We describe a highly accurate and precise method for determination of total cholesterol in serum by isotope dilution/mass spectrometry. The method was developed for a Study Group of the Committee on Standards of the American Association for Clinical Chemistry, for use in establishing the accuracy of a candidate refere...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Cohen A,Hertz HS,Mandel J,Paule RC,Schaffer R,Sniegoski LT,Sun T,Welch MJ,White E 5th

    更新日期:1980-06-01 00:00:00

  • Evaluation of a fully automated serum assay for C-terminal cross-linking telopeptide of type I collagen in osteoporosis.

    abstract:BACKGROUND:Biochemical markers of bone turnover can provide prognostic information about the risk of osteoporotic fracture and are useful tools for monitoring efficacy of antiresorptive therapy. A serum-based automated assay may be of better clinical value than urinary markers because of lower imprecision and day-to-da...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garnero P,Borel O,Delmas PD

    更新日期:2001-04-01 00:00:00

  • Use of a reference standard to improve the accuracy and precision of seven kits for determination of ferritin in serum.

    abstract::We assessed the accuracy and precision of seven commercial kits for serum ferritin. The concentration of ferritin as determined by these assays for a liver ferritin reference standard, a human heart ferritin standard, and normal sera correlated highly, but the absolute values varied widely. Use of an international ref...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Iacobello C,Ghielmi S,Belloli S,Arosio P,Albertini A

    更新日期:1984-02-01 00:00:00

  • Evaluation of two homogeneous methods for measuring high-density lipoprotein cholesterol.

    abstract::We evaluated the performance of two homogeneous assays for quantifying HDL cholesterol (HDL-C) and compared them with the phosphotungstic acid (PTA)/ MgCl2 assay. Both homogeneous HDL-C assays were precise, having a within-run CV of < 1.20% and a between-run CV of < 4.07%. The HDL-C values (y) measured by the two homo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Huang YC,Kao JT,Tsai KS

    更新日期:1997-06-01 00:00:00

  • Enzyme immunoassays with the miniature centrifugal fast analyzer.

    abstract::We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lasky FD,Ahuja KK,Karmen A

    更新日期:1977-08-01 00:00:00

  • Results of a nine-laboratory survey of forensic toxicology proficiency.

    abstract::Toxicological determinations are crucial to coroners' or medical examiners' judgments that drugs are significantly involved in a death. However, differences in laboratory procedures, thoroughness of screening, and limits of detection may result in artifactual differences in the toxicological results and the subsequent...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dinovo EC,Gottschalk LA

    更新日期:1976-06-01 00:00:00

  • Automated measurement of urinary iodine with use of ultraviolet irradiation.

    abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuda K,Namba H,Nomura T,Yokoyama N,Yamashita S,Izumi M,Nagataki S

    更新日期:1995-04-01 00:00:00

  • Improved RNase protection assay for quantifying LDL-receptor mRNA; estimation of analytical imprecision and biological variance in peripheral blood mononuclear cells.

    abstract::We have improved the protocol for RNA quantification by using RNase protection. Instead of precipitation and extraction with phenol and chloroform, we use a faster and more reliable precipitation based on guanidinium thiocyanate (GdSCN). The internal standard is produced by in vitro transcription of a DNA template con...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Petersen NE,Larsen LK,Nissen H,Jensen LG,Jensen A,Hyltoft Petersen P,Hørder,Gregersen N,Kristiansen K

    更新日期:1995-11-01 00:00:00

  • A step forward in enzymatic measurement of creatinine.

    abstract::We describe an improved enzymatic ultraviolet absorbance method for assaying creatinine in serum, plasma, and urine. Creatinine is hydrolyzed by creatinine iminohydrolase (EC 3.5.4.21) to ammonia and N-methylhydantoin. The ammonia produced combines with 2-oxoglutarate and NADPH in the presence of glutamate dehydrogena...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fossati P,Ponti M,Passoni G,Tarenghi G,Melzi d'Eril GV,Prencipe L

    更新日期:1994-01-01 00:00:00

  • N-acetyl-beta-glucosaminidase isoenzymes in serum and urine of patients with diabetes mellitus.

    abstract::The isoenzyme pattern of N-acetyl-beta-glucosaminidase (NAG) in serum and urine was studied in two groups of patients with diabetes mellitus and in 30 control subjects. Total NAG activity was significantly (P less than 0.001) increased in the serum and urine of the 20 diabetics with vascular complications, but was ins...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Severini G,Aliberti LM,Di Girolamo M

    更新日期:1988-12-01 00:00:00

  • Multicenter evaluation of human placental alkaline phosphatase as a possible tumor-associated antigen in serum.

    abstract::Using a solid-phase monoclonal antibody enzyme immuno-assay, we evaluated in a multicenter study (18 laboratories) the utility of evaluating catalytic activity of human placental alkaline phosphatase (hPLAP, EC 3.1.3.1) in serum as a potential tumor marker. We determined hPLAP in serum samples from 130 patients with o...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: De Broe ME,Pollet DE

    更新日期:1988-10-01 00:00:00

  • Medicare's demonstration of competitive bidding for clinical laboratory services: what it means for clinical laboratories.

    abstract::The purpose of Medicare's Demonstration of Competitive Bidding for Clinical Laboratory Services is to determine whether competitive bidding can be used to provide quality laboratory services at prices below current Medicare reimbursement rates. Here, we present key features of the preliminary design for the demonstrat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hoerger TJ,Lindrooth RC,Eggleston JL

    更新日期:1998-08-01 00:00:00

  • Vitamin C and glycohemoglobin.

    abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Weykamp CW,Penders TJ,Baadenhuijsen H,Muskiet FA,Martina W,van der Slik W

    更新日期:1995-05-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Expression of prostate-specific antigen and prostate-specific membrane antigen transcripts in blood cells: implications for the detection of hematogenous prostate cells and standardization.

    abstract::Circulating prostate cells can be detected in cancer patients by using reverse transcriptase-PCR (RT-PCR) assay for prostate-specific antigen (PSA) and prostate-specific membrane antigen (PSM) mRNA. A quality-control study involving a conventional RT-PCR assay was performed and, surprisingly, detected both transcripts...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Gala JL,Heusterspreute M,Loric S,Hanon F,Tombal B,Van Cangh P,De Nayer P,Philippe M

    更新日期:1998-03-01 00:00:00

  • Quality-control (QC) performance measures and the QC planning process.

    abstract::Numerous outcome measures can be used to characterize and compare the performance of alternative quality-control (QC) strategies. The performance measure traditionally used in the QC planning process is the probability of rejecting an analytical run when a critical out-of-control error condition exists. Another perfor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Parvin CA

    更新日期:1997-04-01 00:00:00

  • Measuring alveolar lavage fluid surfactant by fluorescence polarization.

    abstract::We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: McCarroll NA,Van Lente F

    更新日期:1993-07-01 00:00:00

  • Rate of decrease in serum ethchlorvynol concentrations after extreme overdosage-a case study.

    abstract::Ethchlorvynol is a commonly abused sedative hypnotic. I report here a seven-day study of serum ethchlorvynol concentrations in a patient who had received an extreme overdose. These concentrations were correlated with the patient's response to stimuli. Serum ethchlorvynol concentrations were logarithmically related to ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Pochopien DJ

    更新日期:1975-06-01 00:00:00

  • Comparison of enzyme immunoassay and gas chromatography for determination of carbamazepine and ethosuximide in human serum.

    abstract::Patients' sera were analyzed for carbamazepine and ethosuximide by enzyme immunoassay (x) and gas chromatography (y), and the results were compared. The correlation coefficients were: for carbamazepine, x vs. y 0.94 (n = 93); for ethosuximide, x vs. y 0.99 (n = 30). These results suggest that the two methods could be ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Sun L,Szafir I

    更新日期:1977-09-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00