Abstract:
:Measured triglyceride concentrations were extremely low (less than 100 mg/L) in the serum of some patients who were receiving hydroxyurea for myeloproliferative diseases. The assay being used to quantify triglycerides was a "cascaded" enzymatic method involving (a) lipase, to generate glycerol from triglycerides; (b) glycerol oxidase, to convert glycerol to glyceraldehyde, with generation of hydrogen peroxide; and (c) peroxidase, which acts on the hydrogen peroxide with subsequent coupled generation of a red-violet quinone (reagent system used in the Technicon RA-1000). Hydroxyurea added to serum samples appeared to inhibit the action of glycerol oxidase, with a stoichiometric relation to the concentration of substrate (a decrease of roughly 2.4 mmol/L in measured triglyceride per 1 mmol of hydroxyurea per liter). A different enzymatic assay for triglycerides, which involves glycerol kinase (Beckman Instruments) did not show this effect of hydroxyurea.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
McPherson RA,Brown KD,Agarwal RP,Threatte GA,Jacobson RJsubject
Has Abstractpub_date
1985-08-01 00:00:00pages
1355-7issue
8eissn
0009-9147issn
1530-8561journal_volume
31pub_type
杂志文章abstract::I developed a standard procedure for assessing sensitivity, intra-assay precision, parallelism of sample dilutions, and assay drift, using a single trial assay kit. I used this to compare the performance of 10 commercial kits with an in-house radioimmunoassay for human thyrotropin. No one kit stood out as clearly supe...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-01-01 00:00:00
abstract:BACKGROUND:The American Diabetes Association task force on standardization of insulin assays in 1996 showed wide variation in assay bias. Newer assays are specific for insulin, with several now available on automated immunoassay analyzers. METHODS:In 2004, we compared 11 commercially available insulin assays by analyz...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:10.1373/clinchem.2006.077784
更新日期:2007-05-01 00:00:00
abstract::We describe a direct radioimmunoassay for serotonin (5-hydroxytryptamine) in cerebrospinal fluid, platelet-poor plasma, and serum. We raised antisera in rabbits against serotonin diazotized to a conjugate of bovine albumin and D,L-p-aminophenylalanine. Polyethylene glycol, alone or in combination with anti-rabbit immu...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1982-04-01 00:00:00
abstract::The concentrations of 25 plasma proteins were measured in 22 patients with membranous nephropathy. For some large proteins, the plasma concentrations were increased; there were also large proteins with low plasma concentrations, but small or medium-sized proteins showed uniformly lower plasma concentration than the co...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1997-07-01 00:00:00
abstract::We describe a homogeneous substrate-labeled fluorescent immunoassay for human IgM. In this competitive-binding method we use a fluorogenic substrate for Escherichia coli beta-galactosidase, N-(6-aminohexyl)-7-beta-galactosyl-coumarin-3-carboxamide, which is covalently coupled to IgM. The fluorescence emission intensit...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-05-01 00:00:00
abstract::Hepatitis A virus (HAV) infection occurs worldwide and is an important cause of acute viral hepatitis in the US. In this review, I cover the epidemiology, course of infection, clinical manifestations, serological responses, and prevention of this infection. Although most patients completely recover from this disease, ...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:
更新日期:1997-08-01 00:00:00
abstract::A reaction of urea, o-phthalaldehyde and N-(1-naphthyl)ethylenediamine is described for measurement of urea by manual, continuous-flow, and kinetic methods. The continuous-flow system requires 25 mu-l of sample; 40 samples can be analyzed per hour. The kinetic method requires no enzymes, has no lag phase, and has good...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-07-01 00:00:00
abstract::This procedure for routine quantification of albumin in urine is based on the dye-binding properties of albumin with bromphenol blue. The absorbance of 100 microL of urine mixed with 3 mL of color reagent is measured against blank reagent at 610 nm after 30 s. Results vary linearly with albumin concentration up to 6 g...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-02-01 00:00:00
abstract:BACKGROUND:Reduced renal function is an established risk factor for cardiovascular events. We compared 3 measures of renal function--serum cystatin C, serum creatinine, and calculated creatinine clearance--as predictors of subsequent cardiovascular events in a community-based population of elderly individuals. METHODS...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2009.135962
更新日期:2010-05-01 00:00:00
abstract::To determine when a change in serial measurements of prothrombin time in patients receiving oral anticoagulant therapy (ACT) is a statistically significant biological change necessitating dose adjustment, one must know the size of the "critical difference" in statistical terms (i.e., probabilities). In a cohort of 32 ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1995-03-01 00:00:00
abstract::We describe a procedure for determining thiocyanate in plasma with a Technicon AutoAnalyzer I, modified with a 50-mm tubular flow cell to increase the sensitivity of thiocyanate detection. The procedure is suitable for distinguishing cigarette smokers from non-smokers, the mean for smokers being 151 (SD 43) micromol/L...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-03-01 00:00:00
abstract::Radiometric, colorimetric, and two immunochemical methods for measuring total iron-binding capacity are compared. We evaluated the procedures on the basis of precision, applicability to a pediatric population, and accuracy as assessed by analytical recovery of purified transferrin. The immunoephelometric assay for tra...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-10-01 00:00:00
abstract::The most popular pretreatment method of plasma samples for the measurement of ascorbate (AsA) and dehydroascorbate (DHA) has been an acidic deproteinization via metaphosphoric acid or trichloroacetic acid. In general, DHA is absent in plasma samples prepared from human blood in a conventional manner. However, when the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::We describe a procedure by which surfactant/albumin ratios in bronchoalveolar fluid (BALF) may be quantified with the Abbott Laboratories TDx fluorescence polarization analyzer and fetal lung maturity reagents. Adding albumin to BALF samples shifted the surfactant/albumin ratios to within the analytical range of the m...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-07-01 00:00:00
abstract::Optimal reaction conditions for assaying human lactate dehydrogenase pyruvate-to-lactate were determined for isoenzymes 1 and 5 at 25, 30, and 37 degrees C. Three of the nine different buffers examined--imidazole, triethanolamine, and N-tris(hydroxymethyl)-methyl-2-aminoethane sulfonic acid--are satisfactory. Beta-NAD...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-02-01 00:00:00
abstract::A rapid and precise immunoassay for quantification of total homocysteine in blood samples is presented. The method avoids the use of radioisotopes and chromatographic separations and relies on enzymatic conversion of homocysteine to S-adenosyl-L-homocysteine, followed by quantification of S-adenosyl-L-homocysteine by ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1998-02-01 00:00:00
abstract::We evaluated a new, simple, enzymatic kinetic method from Wako Chemicals GmbH in comparison with a kinetic Jaffé method by using isotope dilution-mass spectrometry (ID-MS) as a reference method. An ID-MS-calibrated serum standard was used. Both the enzymatic and the Jaffé method correlated well with ID-MS, except for ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1989-05-01 00:00:00
abstract:BACKGROUND:The kidney performs a multitude of essential functions to maintain homeostasis. In clinical medicine, glomerular filtration rate (GFR) provides the best index of overall kidney function, and proteinuria adds additional information on renal and nonrenal prognosis. Several novel biomarkers of kidney injury and...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2011.167494
更新日期:2012-04-01 00:00:00
abstract::I determined the in vitro biological half-lives or decay constants for creatine kinase isoenzymes at various temperatures. Values at 37 degrees C are consistent with values reported by others in vivo, which suggests that in vivo irreversible inactivation is primarily thermal. Reversible inactivation appears to be an o...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1977-01-01 00:00:00
abstract:BACKGROUND:Vascular age is an emerging health indicator and predictor of end-organ damage to the heart, brain, and kidney. Although there have been many review publications concerning risk factors for vascular aging, most include cross-sectional epidemiological studies, limiting inferences about temporality. There is a...
journal_title:Clinical chemistry
pub_type: 杂志文章,评审
doi:10.1373/clinchem.2018.287623
更新日期:2019-01-01 00:00:00
abstract::A new computer-interfaced system of general applicability in the clinical laboratory has been built. The system is constructed around a new type multicuvette. Quantitation is currently by spectrophotometry and is on-line, with use of a mini-computer with output going to an electrostatic printer/plotter. The system can...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1975-08-01 00:00:00
abstract:BACKGROUND:The 2447 A > T pathogenic variation at codon 816 of exon 17 (D816V) in the KIT gene, occurring in systemic mastocytosis (SM), leads to constitutive activation of tyrosine kinase activity and confers resistance to the tyrosine kinase inhibitor imatinib mesylate. Thus detection of this variation in SM patients...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2006.068205
更新日期:2006-12-01 00:00:00
abstract:BACKGROUND:Cardiovascular mortality is markedly higher in Russia than in Western Europe and the US. Little is known about indicators of atherosclerotic risk in the Russian population. To our knowledge, this is the first study of apolipoprotein (apo) AI and B in Russia based on the WHO-IFCC standard. METHODS:We measure...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2003.023853
更新日期:2004-02-01 00:00:00
abstract:BACKGROUND:Cleavage of conjugates is an important step in toxicological analysis, especially of urine samples. The aim of this study was to combine the advantages and to reduce the disadvantages of acid hydrolysis and conventional enzymatic hydrolysis procedures. METHODS:beta-Glucuronidase (GRD; EC 3.2.1.31) and aryls...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1999-12-01 00:00:00
abstract::We describe a radioassay for cobalamin (vitamin B12) in human serum or plasma that requires no boiling or other pretreatment of the sample. Normal chicken serum covalently coupled to magnetizable particles is used as the binding agent. The assay is performed at pH 12.9, at which pH all cobalamin in human serum is rele...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-02-01 00:00:00
abstract:BACKGROUND:A sensitive gas chromatography-negative ion chemical ionization mass spectrometry (GC/MS-NICI) method was developed and validated for the measurement of Delta(9)-tetrahydrocannabinol (THC) in human sweat patches. METHODS:THC-d(0) and THC-d(3) were added to worn blank sweat patches (PharmChek; PharmChem Inco...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2004.034868
更新日期:2004-11-01 00:00:00
abstract::We describe a new method for quantitatively measuring substances of clinical interest by high-performance liquid affinity chromatography (HPLAC). As a model system we selected analysis for transferrin in human serum with immobilized antibodies in a high-performance liquid chromatographic system. SelectiSpher-10 Activa...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1988-10-01 00:00:00
abstract::We describe a time-resolved immunofluorometric assay (IFMA) for corticotropin in unextracted human plasma, based on the use of two monoclonal antibodies: europium-labeled antibody 1A12 and antibody 2A3 coated onto microtiter wells. We compared the results of this assay with those of an immunoradiometric assay (IRMA) p...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-10-01 00:00:00
abstract::We studied the effects on 25 analytes of duration of contact of serum with non-anticoagulated blood and of temperature. Serum was separated after blood was allowed to stand, for 0, 2, 4, 6, 8, 24, or 48 h at 4, 23, or 30 degrees C. Results obtained for bilirubin, albumin, zinc sulfate turbidity, thymol turbidity, chol...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1981-01-01 00:00:00
abstract::Urinary excretion of orally administered lactulose is used as an index of intestinal permeability. We have developed a simple thin-layer chromatographic technique for measuring lactulose in urine, using silica gel 60 plates and a propanol-borate solvent system. Lactulose concentrations as low as 62.5 mg/L can be detec...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-07-01 00:00:00