Gas-chromatographic determination of mephenytoin and desmethylmephenytoin, after off-column alkylation.

Abstract:

:We describe a gas-liquid chromatographic method for determining mephenytoin and its active metabolite, desmethylmephenytoin, in human serum. 5-Methyl-5-phenylhydantoin is used as the internal standard. The method involves extraction of the drugs by adsorption onto charcoal and off-column derivatization to their pentyl derivatives. Peak height and concentration are linearly related and the day-to-day CV for therapeutic concentration is about 2 to 6%. No interferences by endogenous compounds or drugs commonly used for seizure control have been encountered.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Raisys VA,Zebelman AM,MacMillan SF

subject

Has Abstract

pub_date

1979-01-01 00:00:00

pages

172-5

issue

1

eissn

0009-9147

issn

1530-8561

journal_volume

25

pub_type

杂志文章
  • Studies of the reliability of constituent target values established in a large inter-laboratory survey.

    abstract::Lyophilized serum specimens were manufactured in such a way that fixed quantitative interspecimen relationships were established. The specimens were analyzed for about twenty constituents by several thousand laboratories in 1971, 1972, and 1973. Most of the consensus mean values derived from these analyses were found ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Grannis GF

    更新日期:1976-07-01 00:00:00

  • Homogeneous apoenzyme reactivation immunoassay for thyroxin-binding globulin in serum.

    abstract::In this automated apoenzyme reactivation immunoassay system (Ames Optimate) for thyroxin-binding globulin (TBG), the sample and N6-aminohexylflavin adenine dinucleotide-labeled TBG react sequentially with antiserum. Then apoglucose oxidase is added to combine with the free fraction and generate glucose oxidase activit...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schroeder HR,Johnson PK,Dean CL,Morris DL,Smith D,Refetoff S

    更新日期:1986-05-01 00:00:00

  • Cross reactivity of digitoxin and spironolactone in two radioimmunoassays for serum digoxin.

    abstract::We measured the cross reactivity of two medications--digitoxin and spironolactone--in two digoxin radioimmunoassay (liquid and solid-phase) kit procedures. Both tests showed similar average percentages of cross reactivity with digitoxin (7.2 and 8.9% for intravenous, and 11.9 and 10.9% for oral administration), but no...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Müller H,Bräuer H,Resch B

    更新日期:1978-04-01 00:00:00

  • Tumor necrosis factor-alpha -308G>A allelic variant modulates iron accumulation in patients with hereditary hemochromatosis.

    abstract:BACKGROUND:In vitro and animal studies suggest that tumor necrosis factor alpha (TNF-alpha) modulates intestinal iron transport. We hypothesized that the effect of TNF-alpha might be particularly relevant if iron absorption is not effectively controlled by the HFE gene. METHODS:In patients with homozygous C282Y hemoch...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065417

    authors: Krayenbuehl PA,Maly FE,Hersberger M,Wiesli P,Himmelmann A,Eid K,Greminger P,Vetter W,Schulthess G

    更新日期:2006-08-01 00:00:00

  • Nitromethane interferes in assay of creatinine by the Jaffé reaction.

    abstract::A patient who ingested a methanol/nitromethane mixture (model airplane fuel) showed an apparent plasma creatinine concentration of 8.0 mmol/L by the Jaffé reaction when the actual creatinine concentration, as measured by a specific enzymatic method, was 0.09 mmol/L. This effect was due to nitromethane in the plasma. I...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: De Leacy EA,Brown NN,Clague AE

    更新日期:1989-08-01 00:00:00

  • Enzyme-linked immunosorbent assay of retinol-binding protein in serum and urine.

    abstract::This highly sensitive method for determining retinol-binding protein in human serum and urine is based on a double-antibody "sandwich"-type enzyme-linked immunosorbent assay. The assayable concentration range is 0.8-48 micrograms/L, the detection limit 0.2 micrograms/L. Within-assay coefficients of variation for 10 de...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lucertini S,Valcavi P,Mutti A,Franchini I

    更新日期:1984-01-01 00:00:00

  • Performance of a single assay for both type III and type VI TMPRSS2:ERG fusions in noninvasive prediction of prostate biopsy outcome.

    abstract:BACKGROUND:TMPRSS2:ERG fusions are promising prostate cancer biomarkers. Because they can occur in multiple forms in a single cancer specimen, we developed a quantitative PCR test that detects both type III and type VI TMPRSS2:ERG fusions. The assay is quantified from a standard curve determined with a plasmid-cloned t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.108845

    authors: Clark JP,Munson KW,Gu JW,Lamparska-Kupsik K,Chan KG,Yoshida JS,Kawachi MH,Crocitto LE,Wilson TG,Feng Z,Smith SS

    更新日期:2008-12-01 00:00:00

  • Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.

    abstract::We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Christenson RH,Clemmensen P,Ohman EM,Toffaletti J,Silverman LM,Grande P,Vollmer RT,Wagner GS

    更新日期:1990-08-01 00:00:00

  • Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomizer furnace.

    abstract::We compared a stabilized-temperature L'vov platform furnace containing an end-heated graphite atomizer (HGA) and transverse Zeeman background-correction system with a side-heated furnace system (transversely heated graphite atomizer; THGA) containing a longitudinal Zeeman background-correction system for the determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bradley C,Leung FY

    更新日期:1994-03-01 00:00:00

  • Ferritin concentrations in plasma from capillary (finger prick) blood and venous blood compared.

    abstract::Investigating the feasibility and validity of determining plasma ferritin concentration in blood obtained by finger prick, we studied 29 adults (ages 21-49 years) and 35 children (ages 14-66 months). Blood was sampled simultaneously in the same subject from both the antecubital vein (venous blood) and by finger pricki...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mejía LA,Viteri FE

    更新日期:1983-05-01 00:00:00

  • Determination of erythrocyte folate by competitive protein binding assay preceded by extraction.

    abstract::Determination of the concentration of erythrocyte folate by means of competitive protein binding assay critically depends on the extraction procedure applied. Results will be influenced by variable factors such as the in vitro age of the blood samples, the degree of hemolysis, the presence of ascorbic acid, and the pH...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mortensen E

    更新日期:1976-07-01 00:00:00

  • Evaluation of some critical factors affecting determination of aluminum in blood, plasma, or serum by electrothermal atomic absorption spectroscopy.

    abstract::A digestion procedure involving nitric acid is described for determination of aluminum in blood, serum, and plasma by graphite-furnace atomic absorption spectroscopy. Contamination was not a severe problem if all operations were performed in a dust-free atmosphere. Conditions for such determination of aluminum in bloo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frech W,Cedergren A,Cederberg C,Vessman J

    更新日期:1982-11-01 00:00:00

  • Oxygen toxicity related to exposure to lead.

    abstract::We evaluated superoxide dismutase (EC 1.15.1.1) and glutathione peroxidase (EC 1.11.1.9) activities in the erythrocytes of lead-exposed and nonexposed workers from distinct industries localized in the State of São Paulo, Brazil. Concentrations of either lead or protoporphyrin IX, or both, in blood were used to indicat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Monteiro HP,Abdalla DS,Arcuri AS,Bechara EJ

    更新日期:1985-10-01 00:00:00

  • Diagnostic accuracy of pancreatic enzymes evaluated by use of multivariate data analysis.

    abstract::We analyzed pancreatic enzyme data from 508 patients with suspected pancreatitis by neural network analysis, by an Expert multirule generation protocol, and by receiver-operator characteristic (ROC) curve analysis of a single test result. Neural network analysis showed that use of lipase provided the best means for di...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazmierczak SC,Catrou PG,Van Lente F

    更新日期:1993-09-01 00:00:00

  • Reflectance digital matrix photometry.

    abstract::We have designed and constructed a digital matrix photometer for quantitative measurement of reflected light of small chromophoric areas or colored spots. The areas are divided conceptually into small subunits in which the reflected light is measured. This is done through stepwise scanning with a photodiode array. The...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-06-01 00:00:00

  • Population-based study of repeat laboratory testing.

    abstract:BACKGROUND:Test repetition could be a readily modifiable component of laboratory utilization. Laboratory test repetition has not been rigorously studied at a population-based level. Our objective was to determine the prevalence of, and charges associated with, repetition of eight common laboratory tests. METHODS:We pe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.021220

    authors: van Walraven C,Raymond M

    更新日期:2003-12-01 00:00:00

  • Changes in concentrations of C-reactive protein in serum after kidney or heart transplantation.

    abstract::C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly dep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Castellani W,Abbott LB

    更新日期:1986-04-01 00:00:00

  • Discontinuation of the bleeding time test without detectable adverse clinical impact.

    abstract:BACKGROUND:The bleeding time (BT) test predicts a higher bleeding complication rate in populations at risk for inherited or acquired platelet dysfunction, but it is of limited assistance in evaluating individual patients. There are no reports of clinical outcomes after discontinuation of the BT test. METHODS:Interview...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lehman CM,Blaylock RC,Alexander DP,Rodgers GM

    更新日期:2001-01-01 00:00:00

  • Mycophenolic acid binding to human serum albumin: characterization and relation to pharmacodynamics.

    abstract::Mycophenolate mofetil, the prodrug form of the immunosuppressive agent mycophenolic acid (MPA), is currently in clinical trials evaluating its effectiveness in transplant recipients. In this study, we validated an ultrafiltration system for the reliable measurement of free MPA. Using this technique, we evaluated facto...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nowak I,Shaw LM

    更新日期:1995-07-01 00:00:00

  • Do enzymatic analyses of serum triglycerides really need blanking for free glycerol?

    abstract::Distributions of concentrations of free glycerol in clinical plasma obtained for triglyceride assay were compiled to determine the frequency with which increased concentrations of free glycerol posed a potential problem for clinical interpretation of triglyceride results. Clinical histories were studied in patients wi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jessen RH,Dass CJ,Eckfeldt JH

    更新日期:1990-07-01 00:00:00

  • Laboratory evaluation of the Greiner G-400 discrete selective multichannel analyzer.

    abstract::We evaluated the new Greiner G-400 selective multichannel analyzer. Thirty different tests can be run in combination profile and single-test mode at a rate between 150 and 300 tests per hour. The new photometer allows kinetic and equilibrium (endpoint) measurements. The G-400 analyzer demonstrated excellent precision,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Degiampietro P,Peheim E,Colombo JP

    更新日期:1985-02-01 00:00:00

  • Multicenter evaluation of [-2]proprostate-specific antigen and the prostate health index for detecting prostate cancer.

    abstract:BACKGROUND:Total prostate-specific antigen (tPSA) is flawed for prostate cancer (PCa) detection. [-2]proprostate-specific antigen (p2PSA), a molecular isoform of free PSA (fPSA), shows higher specificity compared with tPSA or percentage of free PSA (%fPSA). The prostate health index (Phi), a measure based on p2PSA and ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:10.1373/clinchem.2012.195784

    authors: Stephan C,Vincendeau S,Houlgatte A,Cammann H,Jung K,Semjonow A

    更新日期:2013-01-01 00:00:00

  • Automated measurement of urinary iodine with use of ultraviolet irradiation.

    abstract::We have modified an automated measurement system of urinary iodine (UI) and established a sensitive UI assay system by using ultraviolet (UV) digestion. The automated system is sensitive enough to detect concentrations of UI < 0.78 mumol/L (< 10 micrograms/dL) in a small volume of urine (500 microL). Sample throughput...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tsuda K,Namba H,Nomura T,Yokoyama N,Yamashita S,Izumi M,Nagataki S

    更新日期:1995-04-01 00:00:00

  • Is determination of creatine kinase-2 after electrophoretic separation accurate?

    abstract::Since 1991, the Ontario Laboratory Proficiency Testing Program has assessed the analytical performance of creatine kinase (CK; EC 2.7.3.2) isoenzyme-2, using fresh human serum supplemented with purified human CK isoenzymes. In Ontario, the 142 laboratories licensed to analyze CK-2 use a variety of methods: electrophor...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Henderson AR,Stark JA,McQueen MJ,Patten RL,Krishnan S,Wood DE,Webb S

    更新日期:1994-02-01 00:00:00

  • Improved thin-layer chromatographic determination of phospholipids in gastric aspirate from newborns, for assessment of lung maturity.

    abstract::This one-dimensional thin-layer chromatographic method is used for assay of phospholipids in the gastric aspirate of newborns. The solvent mixture (chloroform/hexane/methanol/glacial acetic acid/water, 12/7/4/3/0.3 by vol) completely resolves lecithin, sphingomyelin, phosphatidylinositol, phosphatidylserine, phosphati...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Serrano de la Cruz D,Santillana E,Mingo A,Fuenmayor G,Pantoja A,Fernández E

    更新日期:1988-04-01 00:00:00

  • Thyroxine-binding globulin capacity and concentration evaluated from blood spots on filter-paper in a screening program for neonatal hypothyroidism.

    abstract::We describe a simple method for evaluating thyroxine-binding globulin capacity and concentration from a single 1-cm blood spot on filter-paper used in a screening program for neonatal hypothyroidism. This method permits prompt diagnosis of about 90% of the infants with thyroxine-binding globulin deficiency in our abno...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Dussault JH,Morissette J,Letarte J,Guyda H,Laberge C

    更新日期:1980-03-01 00:00:00

  • Comparison of a logistic and a mass-action curve for radioimmunoassay data.

    abstract::This paper compares a logistic curve and a mass-action curve in their ability to represent radioimmunoassay standard curves. A data base from 10 different assays is used in this comparison. Six of the 10 assays could be modeled equally well by either the logistic or the mass-action curve. In one case the mass-action c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Raab GM

    更新日期:1983-10-01 00:00:00

  • Alternatives to radioimmunoassay: labels and methods.

    abstract::We review the following labels used as substitutes for radioisotopes in immunoassay systems: bacteriophages, chemiluminescence precursors, fluorochromes, fluorogens, fluorescence quenchers, enzymes, coenzymes, inhibitors, substrates, various particulates, metal atoms, and stable free radicals. New methods for performi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Schall RF Jr,Tenoso HJ

    更新日期:1981-07-01 00:00:00

  • Diagnosis of hemolytic disease by electrophoresis of erythrocyte lactate dehydrogenase isoenzymes on cellulose acetate or Agarose.

    abstract::We determined the LD-1/LD-2 isoenzyme ratio in hemolysates of erythrocytes by electrophoresis on cellulose acetate and on agarose. A ratio exceeding 1.0 was found with the former but not the latter. Results were similar for in vitro models of hemolytic disorders. Using cellulose acetate electrophoresis, we determined ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Marchand A,Galen RS

    更新日期:1981-08-01 00:00:00

  • Measurement of thyroglobulin by liquid chromatography-tandem mass spectrometry in serum and plasma in the presence of antithyroglobulin autoantibodies.

    abstract:BACKGROUND:Measurement of serum thyroglobulin (Tg) is used to monitor patients after treatment for differentiated thyroid carcinoma (TC). Difficulty in using Tg as a biomarker of the recurrence of TC in many patients stems from the presence of endogenous anti-Tg autoantibodies (Tg-AAbs), which can interfere with immuno...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2012.195594

    authors: Kushnir MM,Rockwood AL,Roberts WL,Abraham D,Hoofnagle AN,Meikle AW

    更新日期:2013-06-01 00:00:00