Ferritin concentrations in plasma from capillary (finger prick) blood and venous blood compared.

Abstract:

:Investigating the feasibility and validity of determining plasma ferritin concentration in blood obtained by finger prick, we studied 29 adults (ages 21-49 years) and 35 children (ages 14-66 months). Blood was sampled simultaneously in the same subject from both the antecubital vein (venous blood) and by finger pricking (capillary blood). The plasma was obtained by centrifugation. Ferritin concentration was determined by immunoradiometric analysis. Ferritin concentration in plasma from capillary blood was significantly higher than in venous plasma (p less than 0.01). This difference was more marked in children. The correlation between ferritin from the two blood sources was highly significant (r2 = 0.945 and 0.994 for samples from adults and children, respectively), and the slopes of the respective regression lines in both children and adults were significantly different from 1 (p less than 0.0001). We conclude that, despite the close association between the two procedures, the determination of ferritin concentration in capillary blood plasma overestimates the concentration of ferritin in venous blood plasma.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Mejía LA,Viteri FE

subject

Has Abstract

pub_date

1983-05-01 00:00:00

pages

871-3

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

29

pub_type

杂志文章
  • Inhibition of Na,K-ATPase by oleandrin and oleandrigenin, and their detection by digoxin immunoassays.

    abstract::Ingestion of oleander plant, containing the cardiac glycoside oleandrin, has been reported to induce fatal poisonings. Derivatives of oleandrin are structurally similar to digoxin. We investigated the cross-reactivities of oleandrin and its aglycone metabolite, oleandrigenin, in several commercially available digoxin ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Jortani SA,Helm RA,Valdes R Jr

    更新日期:1996-10-01 00:00:00

  • Sensitive time-resolved fluoroimmunoassay of salmon calcitonin.

    abstract::A two-site assay was developed by use of the "dissociation and enhancement lanthanide fluoroimmunoassay" (DELFIA) technique for determination of salmon calcitonin (SCT) in serum after administration to osteoporotic patients. Polyclonal antibodies were produced in rabbits immunized with SCT coupled to ovalbumin. After ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rong H,Tørring O,Sääf M,Sjöstedt U,Sjöberg HE,Bucht E

    更新日期:1994-09-01 00:00:00

  • Ion chromatography: a new technique for clinical chemistry.

    abstract::Ion chromatography is a new analytical technique in which the ions to be analyzed are separated on a special pellicular ion-exchange column. Once separated, the effluent from the separating column passes into a second ion-exchange column, which removes the eluent or buffer ions from the moving phase without removing t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anderson C

    更新日期:1976-09-01 00:00:00

  • New enzyme-linked immunosorbent assay for glycocalicin in plasma.

    abstract::A new sandwich-type enzyme-linked immunosorbent assay for quantifying glycocalicin, a proteolytic fragment of platelet membrane glycoprotein Ib, is described. The assay is based on the use of two monoclonal antibodies raised against glycoprotein Ib and involves the avidin-biotin technique. The detection limit is 7 mic...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kunishima S,Hayashi K,Kobayashi S,Naoe T,Ohno R

    更新日期:1991-02-01 00:00:00

  • Glucocorticoid receptors in normal leukocytes: effects of age, gender, season, and plasma cortisol concentrations.

    abstract::We measured glucocorticoid receptors (GR) in mononuclear leukocytes (MNL) isolated from peripheral blood of 145 apparently healthy volunteers (86 men and 59 women). An age-related decrease in the number of GR was suggested between subjects younger than 20 years and elderly subjects; there was no apparent seasonal vari...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Tanaka H,Akama H,Ichikawa Y,Homma M,Oshima H

    更新日期:1991-10-01 00:00:00

  • Validation of RNA arbitrarily primed PCR probes hybridized to glass cDNA microarrays: application to the analysis of limited samples.

    abstract:BACKGROUND:The applicability of microarray-based transcriptome massive analysis is often limited by the need for large amounts of high-quality RNA. RNA arbitrarily primed PCR (RAP-PCR) is an unbiased fingerprinting PCR technique that reduces both the amount of initial material needed and the complexity of the transcrip...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.036236

    authors: Grau M,Solé X,Obrador A,Tarafa G,Vendrell E,Valls J,Moreno V,Peinado MA,Capellá G

    更新日期:2005-01-01 00:00:00

  • 4-Chlorotestosterone acetate metabolites in cattle after intramuscular and oral administrations.

    abstract::The use of 4-chlorotestosterone acetate by farmers for cattle fattening was recently demonstrated although the use of this anabolic steroid is strictly forbidden in the European Union. We investigated the metabolism of 4-chlorotestosterone acetate in the bovine species after intramuscular and oral administration. Nine...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Le Bizec B,Montrade MP,Monteau F,Gaudin I,Andre F

    更新日期:1998-05-01 00:00:00

  • Determination of vanillylmandelic acid with ion-pair chromatography and fluorescence detection.

    abstract::We describe a chromatographic procedure for sensitive (2.0 mumol/L), specific quantification of vanillylmandelic acid (VMA) in urine with iso-VMA as an internal standard. After rapid extraction from urine, the VMA is determined by isocratic reversed-phase ion-pair chromatography on a bonded C8 column and detection of ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lindgren K,Rodopoulos N

    更新日期:1986-04-01 00:00:00

  • Use of values for calcium and protein in serum, and of a derived index obtained from a probability population sample.

    abstract::We measured serum protein and calcium concentrations in 2340 individuals between 10 and 96 years of age from 900 families chosen by probability methods to give a representative population. These values were used to calculate an index, based on a regression analysis of serum protein on calcium, which was then treated a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kelly A,Munan L,PetitClerc C,Ho KP,Billon B

    更新日期:1976-10-01 00:00:00

  • Effect of stripping thyroxin from thyroxin-binding globulin on the measurement of free thyroxin in serum by equilibrium dialysis and by radioimmunoassay.

    abstract::In considering factors that might influence measurement of free thyroxin (T4), we evaluated the proportion (%) of T4 that could be stripped from thyroxin-binding globulin (TBG). The percentage of free T4 was measured in serially diluted sera from four normal subjects, four patients with hyperthyroidism or hypothyroidi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Nakagawa T,Matsumura K,Takeda K,Shinoda N,Matsuda A,Matsushita T,Tagami T

    更新日期:1990-02-01 00:00:00

  • Immunochemical determination of human immunoglobulins: use of kinetic turbidimetry and a 36-place centrifugal analyzer.

    abstract::We describe the measurement of human immunoglobulins IgG, IgA, and IgM in diluted sera, with diluted commercial monospecific antisera, with use of a 36-place centrifugal analyzer (RotoChem IIa; American Instrument Co., Silver Spring, MD 20920). The assay involves a two-point kinetic turbidimetric technique. The change...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Finley PR,Williams RJ,Lichti DA,Griffith F,Thies AC

    更新日期:1979-04-01 00:00:00

  • Changes in concentrations of C-reactive protein in serum after kidney or heart transplantation.

    abstract::C-reactive protein (CRP) concentrations were serially determined in serum after kidney or heart transplantation. The initial postsurgical CRP response in these patients was compared with that of control patients undergoing related procedures but not subjected to immunosuppressive therapy. Immunosuppression clearly dep...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Van Lente F,Castellani W,Abbott LB

    更新日期:1986-04-01 00:00:00

  • Diagnosis of type III hyperlipoproteinemia by chromatography of plasma lipoproteins on columns containing agarose.

    abstract::Agarose column chromatography has been used to separate plasma lipoproteins into very-low-density lipoproteins (VLDL), low-density lipoproteins (LDL) and high-density lipoproteins (HDL). Applied to the diagnosis of primary type III hyperlipoproteinemia, the procedure is capable of demonstrating three characteristic an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shepherd J,Packard CJ,Dryburgh FJ,Third JL

    更新日期:1975-12-01 00:00:00

  • Plasma F2-isoprostanes and coronary artery calcification: the CARDIA Study.

    abstract:BACKGROUND:Oxidation of lipids in lipoproteins and cells may initiate and enhance the early development of cardiovascular disease. METHOD AND RESULTS:We assayed F(2)-isoprostanes, oxidation products of arachidonic acid, by gas chromatography-mass spectrometry in a biracial cohort of 2850 young healthy adult men and wo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2004.037630

    authors: Gross M,Steffes M,Jacobs DR Jr,Yu X,Lewis L,Lewis CE,Loria CM

    更新日期:2005-01-01 00:00:00

  • 99th Percentile Upper-Reference Limit of Cardiac Troponin and the Diagnosis of Acute Myocardial Infarction.

    abstract:BACKGROUND:Concerns exist regarding how the 99th percentile upper reference limit (URL) of cardiac troponin (cTn) is determined and whether it should be derived from normal healthy individuals. CONTENT:The 99th percentile URL of cTn is an important criterion to standardize the diagnosis of myocardial infarction (MI) f...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1093/clinchem/hvaa158

    authors: Sandoval Y,Apple FS,Saenger AK,Collinson PO,Wu AHB,Jaffe AS

    更新日期:2020-09-01 00:00:00

  • Comparing multivariate and univariate subject-specific reference regions for blood constituents in healthy persons.

    abstract::We examined the comparative behavior of subject-specific multivariate and univariate reference regions, using both computer-generated data and serial (semi-annual) measurements of selected analytes in subjects from a large health-maintenance program. Univariate studies under both homeostatic and random-walk time-serie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Harris EK,Yasaka T,Horton MR,Shakarji G

    更新日期:1982-03-01 00:00:00

  • Two-dimensional electrophoretic patterns of proteins of normal mucosa, polyps, and carcinomas of the large intestine.

    abstract::Two-dimensional protein maps of biopsies from normal mucosa, tubular adenomas (polyps), and colonic carcinomas in humans have been studied in order to obtain information on the possible precancerous role of intestinal polyps. The maps are complex and several hundred protein spots are seen after staining with Coomassie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thorsrud AK,Vatn MH,Jellum E

    更新日期:1982-04-01 00:00:00

  • Reduced Testicular Steroidogenesis and Increased Semen Oxidative Stress in Male Partners as Novel Markers of Recurrent Miscarriage.

    abstract:BACKGROUND:Recurrent pregnancy loss, (RPL) affecting 1%-2% of couples, is defined as ≥3 consecutive pregnancy losses before 20-week' gestation. Women with RPL are routinely screened for etiological factors, but routine screening of male partners is not currently recommended. Recently it has been suggested that sperm qu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.289348

    authors: Jayasena CN,Radia UK,Figueiredo M,Revill LF,Dimakopoulou A,Osagie M,Vessey W,Regan L,Rai R,Dhillo WS

    更新日期:2019-01-01 00:00:00

  • Separation of synthetic mixtures of sugars and of sugars in body fluids with a high-resolution carbohydrate analyzer.

    abstract::With use of a specially designed gradient-generating system, of anion-exchange resins of 10-20 mum particle diameter, and of an orcinol solution in concentrated sulfuric acid (1 g/liter) as detection reagent, a mixture of 16 carbohydrates can be separated in less than 4 h. The limit of detection for most sugars is in ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Voelter W,Bauer H

    更新日期:1975-12-01 00:00:00

  • Improved determination of aluminum in serum by electrothermal atomic absorption spectrophotometry.

    abstract::This method for determining aluminum in human serum involves electrothermal atomic absorption spectrophotometry. A longer drying time allows less pre-dilution of the sample, and the method also includes a flush cycle after atomization. Standard-addition methodology is used to eliminate matrix effects and the need for ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bertholf RL,Brown S,Renoe BW,Wills MR,Savory J

    更新日期:1983-06-01 00:00:00

  • Thin film biosensor for rapid visual detection of nucleic acid targets.

    abstract:BACKGROUND:We have developed a silicon-based biosensor that generates a visual signal in response to nucleic acid targets. METHODS:In this system, capture oligonucleotide probes are immobilized on the surface of the biosensor. Interaction of the capture probes with a complementary target and a biotinylated detector ol...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ostroff RM,Hopkins D,Haeberli AB,Baouchi W,Polisky B

    更新日期:1999-09-01 00:00:00

  • Evaluation of nicked human chorionic gonadotropin content in clinical specimens by a specific immunometric assay.

    abstract::We report the development and characterization of an IRMA for the direct measurement of nicked human chorionic gonadotropin (hCGn) in blood and urine. hCGn derived from a reference preparation of hCG used as an immunogen elicits monoclonal antibodies (mAbs) with enhanced recognition of human luteinizing hormone epitop...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kovalevskaya G,Birken S,Kakuma T,Schlatterer J,O'Connor JF

    更新日期:1999-01-01 00:00:00

  • Serum creatine kinase isoenzyme BB is a poor index to the size of various brain lesions.

    abstract::We divided patients with brain lesions into three groups: (a) patients with primary or metastatic brain cancer, (b) brain infarctions, and (c) brain contusion(s). We analyzed each patient's sera for creatine kinase isoenzyme BB (CK-BB), using a monoclonal antibody kit (Impres-BB; International Immunoassay Laboratories...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Schwartz JG,Bazan C 3rd,Gage CL,Prihoda TJ,Gillham SL

    更新日期:1989-04-01 00:00:00

  • Automated enzymic measurement of total cholesterol in serum.

    abstract::We describe a completely automated enzymic system for measuring total cholesterol in serum. All reagents are contained in an analytical test pack and the test is performed on Du Pont's Automatic Clinical Analyzer (aca), which mixes the sample (20 microliter) and reagents and performs the necessary absorbance measureme...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Rautela GS,Liedtke RJ

    更新日期:1978-01-01 00:00:00

  • Contribution of CYP3A5 to the in vitro hepatic clearance of tacrolimus.

    abstract:BACKGROUND:Tacrolimus is metabolized predominantly to 13-O-demethyltacrolimus in the liver and intestine by cytochrome P450 3A (CYP3A). Patients with high concentrations of CYP3A5, a CYP3A isoenzyme polymorphically produced in these organs, require higher doses of tacrolimus, but the exact mechanism of this association...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.050047

    authors: Kamdem LK,Streit F,Zanger UM,Brockmöller J,Oellerich M,Armstrong VW,Wojnowski L

    更新日期:2005-08-01 00:00:00

  • High-density lipoprotein subfractions measured in stored serum.

    abstract::We compared the effects of freezing serum on the determination of high-density lipoprotein (HDL) subfractions by two dual-precipitation methods, heparin and manganese chloride/dextran sulfate (HM/DS) (Gidez et al., J Lipid Res 1982;23:1206-23) and DS/DS (Warnick et al., Clin Chem 1982;28:1574), and by ultracentrifugat...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bausserman LL,Saritelli AL,Milosavljevic D

    更新日期:1994-09-01 00:00:00

  • Fully automated assay of glycohemoglobin with the Abbott IMx analyzer: novel approaches for separation and detection.

    abstract::We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuri...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wilson DH,Bogacz JP,Forsythe CM,Turk PJ,Lane TL,Gates RC,Brandt DR

    更新日期:1993-10-01 00:00:00

  • Replacing creatinine measurements with specific gravity values to adjust urine cotinine concentrations.

    abstract::Creatinine and specific gravity (relative density) measurements both allow differences in urine concentration to be taken into account in determining urine cotinine concentrations. In this study we demonstrate that the variance of urine cotinine measurements is reduced comparably when either creatinine or specific gra...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Haddow JE,Knight GJ,Palomaki GE,Neveux LM,Chilmonczyk BA

    更新日期:1994-04-01 00:00:00

  • Low bias in assayed values of lipoprotein antigens--lipoprotein(a) and apolipoproteins A-I and B--in midday postprandial blood specimens compared with morning fasting specimens.

    abstract::Two-hour postprandial specimens have a -14% proportional bias for lipoprotein(a) [Lp(a)], a -0.035 g/L systematic bias for apolipoprotein (apo) A-I, and a -9% proportional bias for apo B, compared with values in 12-h fasting specimens. Although a physiological hemodilution appears to account for a portion of these bia...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Emancipator K

    更新日期:1992-03-01 00:00:00

  • Measurement of prostate-specific antigen by radioimmunoassay.

    abstract::We describe the performance of an RIA for the measurement of prostate-specific antigen (PA). Between-assay precision (CV) for control sera with various analyte concentrations was as follows: mean = 1.67 micrograms/L, CV = 7.1%; mean = 4.47 micrograms/L, CV = 5.6%; mean = 7.15 micrograms/L, CV = 5.5% (n = 19 each). Ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Liedtke RJ,Batjer JD

    更新日期:1984-05-01 00:00:00