Abstract:
:We describe a novel assay for measuring glycohemoglobin directly from anticoagulated whole blood with the Abbott IMx analyzer. The glycohemoglobin is labeled with a soluble polyanionic affinity reagent and the anionic complex is then captured with a cationic solid-phase matrix. Glycohemoglobin is quantified by measuring the quenching by heme of the static fluorescence from an added fluorophore. The assay is standardized to report both percent total glycohemoglobin (%GHb) and percent hemoglobin A1c (%HbA1c). Glucose, bilirubin, triglycerides, labile fraction, and hemoglobin variants do not interfere in the assay. Within- and between-run CVs are approximately 4-5%, with total CVs of approximately 6.5%. Highly significant linear correlations (r > 0.97) were obtained in comparison studies with two major assay methodologies. The time to obtain one result is approximately 10 min (including assay of a control), 56 min for 22 results. We describe the development, standardization, and validation of this new method.
journal_name
Clin Chemjournal_title
Clinical chemistryauthors
Wilson DH,Bogacz JP,Forsythe CM,Turk PJ,Lane TL,Gates RC,Brandt DRsubject
Has Abstractpub_date
1993-10-01 00:00:00pages
2090-7issue
10eissn
0009-9147issn
1530-8561journal_volume
39pub_type
杂志文章abstract::Currently, we can make the following generalizations about the major long-term complications of diabetes. First, they occur commonly after 10 to 15 years of diabetes. Second, the complications of renal and retinal disease, but not of atherogenic and neurological disease, appear to be related to the severity of hypergl...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,评审
doi:
更新日期:1986-10-01 00:00:00
abstract:BACKGROUND:Mutations in the retina-specific ABC transporter (ABCA4) gene have been associated with several forms of macular degenerations. Because the high complexity of the molecular genotype makes scanning of the ABCA4 gene cumbersome, we describe here the first use of denaturing HPLC (DHPLC) to screen for ABCA4 muta...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.033241
更新日期:2004-08-01 00:00:00
abstract:BACKGROUND:Multiplexed amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, asymmetric PCR, or allele-specific PCR; however, correct differentiation of homozygous mutant and wild-type samples by melting temperature (T(m)) analysis requires high-resolution melting ana...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2007.097121
更新日期:2008-01-01 00:00:00
abstract::We evaluated five quantitative, commercially available radioimmunoassay methods (Beta-Tec, BIO-RIA, Cambridge Nuclear, Mallinckrodt, and Serono) for rapid determination of the beta-subunit of human choriogonadotropin in serum or plasma. Only three of the kits (Beta-Tec, Mallinckrodt, and Serono) were found suitable fo...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-12-01 00:00:00
abstract:BACKGROUND:An accurate determination of the major HFE mutation (C282Y), which is associated with hereditary hemochromatosis, is important in diagnosis and risk assessment for this disease. We report a single-tube high-throughput PCR method for the detection of C282Y. METHODS:We combined three previously described prin...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2000-10-01 00:00:00
abstract::We studied the relationship between serum erythropoietin (EPO) concentration and iron status in 67 patients undergoing chronic hemodialysis. Serum concentrations of EPO were measured by RIA with recombinant human EPO. The geometric mean of the serum EPO concentration was 10.9 int. units/L (mean +/- SD range = 7.8 - 15...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1992-02-01 00:00:00
abstract::We developed a fluorometric method for determining delta-aminolevulinic acid (ALA) in urine of lead workers. A high-performance liquid chromatograph (HPLC) equipped with a fluorescence HPLC monitor is used. The detection limit for aqueous ALA is 20 micrograms/L (15 pmol of ALA in the 100-microL sample). The working li...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-09-01 00:00:00
abstract:BACKGROUND:In this study we demonstrate the technical application of flow cytometry and cell sorting combined with gene-rearrangement clonality profiling to detect and confirm minimal disease in 2 leukemia and 2 lymphoma cases. METHODS:Specimens with low percentages (0.05%-5%) of abnormal lymphoid populations were ide...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.061259
更新日期:2006-03-01 00:00:00
abstract:BACKGROUND:The majority of patients with chronic kidney disease are diagnosed and monitored in primary care. Glomerular filtration rate (GFR) is a key marker of renal function, but direct measurement is invasive; in routine practice, equations are used for estimated GFR (eGFR) from serum creatinine. We systematically a...
journal_title:Clinical chemistry
pub_type: 杂志文章,meta分析
doi:10.1373/clinchem.2017.276683
更新日期:2018-03-01 00:00:00
abstract::We have separated serum proteins in only 15 min by high-performance liquid chromatography. The identification of several peaks in the chromatographic profile was greatly aided by the use of multiple-wavelength detection. We have found a good correlation between retention times and electrophoretic mobilities. Serum sam...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1980-09-01 00:00:00
abstract:BACKGROUND:The B-type natriuretic peptides (BNP and N-terminal pro-BNP) are secreted by the heart and, in the case of BNP, serve to maintain circulatory homeostasis through renal and vascular actions and oppose many effects of the renin-angiotensin system. Recent evidence suggests that in patients with severe heart fai...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2013.210435
更新日期:2014-03-01 00:00:00
abstract:BACKGROUND:Little is known about trace metal alterations in the bones of dialysis patients or whether particular types of renal osteodystrophy are associated with either increased or decreased skeletal concentrations of trace elements. Because these patients are at risk for alterations of trace elements as well as for ...
journal_title:Clinical chemistry
pub_type: 杂志文章,多中心研究
doi:
更新日期:1999-09-01 00:00:00
abstract:BACKGROUND:Cardiac troponins are specific biochemical markers of myocardial injury used in the diagnosis of acute myocardial disease and cardiac risk stratification. To avoid misclassification of patients, troponin assays must demonstrate precision at the low end of the measuring range. We report our evaluation of the ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2005.057216
更新日期:2006-02-01 00:00:00
abstract:BACKGROUND:Paraoxonase may protect lipoproteins and cell membranes from peroxidation, and alterations in the activity of this enzyme have been associated with some chronic diseases. Serum paraoxonase appears to be mainly under genetic control, but some studies suggest that environmental factors may also modulate its ac...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/49.9.1491
更新日期:2003-09-01 00:00:00
abstract:BACKGROUND:The recent discovery of the presence of circulating cell-free fetal DNA in maternal plasma opens up new prenatal diagnostic applications and provides new avenues for clinical investigation. It is of research and potential diagnostic interest to determine whether fetal trisomy 21 may be associated with quanti...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,多中心研究
doi:
更新日期:1999-10-01 00:00:00
abstract::We investigated glycosylated hemoglobin S by means of chromatography on Bio-Rex 70. The selected elution conditions were similar to those described by Trivelli et al. (N Engl J Med 284: 353-357, 1971), except for modified ionic strength and accurate temperature control. This enabled us to isolate a minor hemoglobin fr...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1985-04-01 00:00:00
abstract:BACKGROUND:C-Reactive protein (CRP) has been shown to be a strong predictor of coronary heart disease (CHD) and is being considered in cardiovascular disease risk assessment. The number of normolipidemic individuals who are eligible for evaluation of CRP in overall CHD risk assessment is not known. METHODS:We analyzed...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:10.1373/clinchem.2004.036004
更新日期:2004-09-01 00:00:00
abstract::Genetic engineering of beta-galactosidase (EC 3.2.1.23) has led to the development of a new homogeneous assay system, CEDIA. The Z gene of the lac operon of Escherichia coli encodes a large enzymatically inactive polypeptide that spontaneously aggregates and folds to form active beta-galactosidase. Using recombinant D...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract:BACKGROUND:Thrombopoietin (TPO), the major hormone controlling platelet production, has been measured in thrombocytopenias with discordant results. The aim of our work was to assess the value of the TPO assay for differential diagnosis of thrombocytopenias in a large cohort of patients classified according to the resul...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:2001-09-01 00:00:00
abstract::The serum pancreolauryl test has limited sensitivity for detecting mild pancreatic insufficiency. The aim of this study was to optimize the serum pancreolauryl test so as to increase the probability of positive results in patients with chronic pancreatitis. The study had three parts. First, the sampling time was optim...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1998-04-01 00:00:00
abstract::We modified the liquid-chromatographic assay of Schleicher and Wieland (J Clin Chem Clin Biochem 1981; 19:81-7) for measuring lysine-bound glucose in serum proteins, increasing its performance and practicality. After precipitating serum proteins from 10- to 50-microL samples with ethanol (700 mL/L) and hydrolyzing the...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1987-09-01 00:00:00
abstract:BACKGROUND:Nandrolone is one of the most abused anabolic steroids, and its use in doping is increasing, as revealed by numerous positive cases during recent years in various sports. Different authors have reported the possible natural production of nandrolone metabolites in humans, and some of these authors argued that...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:10.1373/clinchem.2003.022848
更新日期:2004-02-01 00:00:00
abstract:BACKGROUND:Increased plasma lipoprotein(a) [Lp(a)] concentrations have been reported to be an independent risk factor for coronary heart disease (CHD) in some prospective studies, but not in others. These inconsistencies may relate to a lack of standardization and the failure of some immunoassays to measure all apolipo...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章
doi:
更新日期:1999-07-01 00:00:00
abstract:BACKGROUND:Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS:Blood samples were collected with and withou...
journal_title:Clinical chemistry
pub_type: 临床试验,杂志文章,多中心研究
doi:
更新日期:2000-06-01 00:00:00
abstract::The S-peptide and S-protein fragments of ribonuclease S (RNase S, no EC no. assigned) have been immobilized onto separate Sepharose gels via a "leash" of polycytidylic acid substrate. Each of these gels releases its RNase fragment when treated with the complementary enzyme fragment or with RNase A (EC 3.1.27.5), and t...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract::We used enzyme immunoassay to measure apolipoprotein B concentration in human plasma. Pure lipoprotein B was isolated from serum samples of fasting normolipidemic subjects by sequential preparative ultracentrifugation and coated to a polystyrene tube surface by adsorption. Human serum samples and rabbit antiserum to h...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1978-03-01 00:00:00
abstract::We have developed an automated latex agglutination test for Treponema pallidum (TPLA) for measurement of the concentration of treponemal antibodies in syphilitic sera. The assay needs neither a complicated pretreatment of the sera nor special techniques. Intra- and interassay precision studies showed high reproducibil...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1993-08-01 00:00:00
abstract::We describe a rapid, reliable radioimmunoassay for unconjugated estriol in plasma. Polyethylene glycol (Carbowax 6000) is used to separate antibody-bound and free steroid. The assay is sensitive (25 pg for standards), precise, and accurate. At high and low concentrations of estriol, intra-assay coefficients of variati...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1976-03-01 00:00:00
abstract::To obtain the best estimates of the average intraindividual biological variability (CVb) in the concentrations of total cholesterol (TC), low-density lipoprotein cholesterol (LDLC), high-density lipoprotein cholesterol (HDLC), and triglyceride serum lipids in a person's blood, we evaluated results from 30 studies publ...
journal_title:Clinical chemistry
pub_type: 杂志文章,meta分析
doi:
更新日期:1993-06-01 00:00:00
abstract::We describe an automated (ABA-100) enzymic method for determination of urinary oxalate by use of oxalate oxidase (EC 1.2.3.4) isolated from beet stems. The H2O2 produced by the oxidation of oxalate by oxalate oxidase is measured by coupling with oxidation and conjugation of 3-methyl-3-benzothiazolinone hydrazone with ...
journal_title:Clinical chemistry
pub_type: 杂志文章
doi:
更新日期:1983-10-01 00:00:00